# NVIDIA Base Command Manager Auto Scaler

## 8.1  Introduction

NVIDIA Base Command Manager Auto Scaler can be used by an administrator to reduce the energy costs, and the costs associated with (cloud) storage, by compute nodes. This can be done by changing their power state, or their existence state, according to workload demands. The idea behind Auto Scaler is that it automatically scales a cluster up or down, on-demand, by powering up physical nodes or cloud nodes.

On the cluster itself, Auto Scaler is implemented by the `cm-scale` service. The scaling is carried out according to settings in the `ScaleServer` role which set the nodes that are to use the `cm-scale` service.

The `cm-scale` service runs as a daemon. It collects information about workloads from different workload engines, and it uses knowledge of the nodes in the cluster. In the case of HPC jobs, the daemon also gathers knowledge of the queues that the jobs are to be assigned to, and also gathers knowledge on which of the HPC jobs are requesting exclusive node access.

**NOTE:** HPC GE jobs have no queue assignment by default, and are therefore ignored by default. Adding a line such as:\
`-q all.q`\
to the `var/` \<*instance name*>`/common/sge_request` file, under `/cm/shared/apps/uge/`, assigns GE jobs to the `all.q` queue by default, so that `cm-scale` considers them.

Based on the workload engine information and queues knowledge, the `cm-scale` service can clone and start compute nodes when the workloads are ready to start. The service also stops or terminates compute nodes, when no queued or running workloads remain on the managed nodes.

### 8.1.1  Use Cases

The `cm-scale` service can be considered as a basis for the construction of different kinds of dynamic data centers. Within such centers, nodes can be automatically re-purposed from one workload engine setup to another, or they can be powered on and off based on the current workload demand.

A few use cases are discussed next, to show how this basis can be built upon:

1. An organization wants to run PBS Professional and Slurm on the same cluster, but how much one workload engine is used relative to the other varies over time. For this case, nodes can be placed in the same pool and shared. When a node finishes an existing job, the `cm-scale` service can then re-purpose that node from one node category to another if needed, pretty much immediately. The re-purposing decision for the node is based on the jobs situation in the PBS Professional and Slurm queues.

2. An organization would like to use their cluster for both Kubernetes and for Slurm jobs. For this case, the admin adds Kubernetes- and Slurm-related settings to the `ScaleServer` role. Using these settings, the `cm-scale` service then switches nodes from one configuration overlay to another. For example, if Slurm jobs are pending and there is a free Kubernetes node, then the node is turned into a Slurm node pretty much immediately. A configuration example for this case is given in section [8.4.9](#849-auto-scaling-a-job-on-premises-to-a-workload-manager-and-kubernetes).

3. An organization has a small cluster with Slurm installed on it, and would like to be able to run more jobs on it. This can be carried out using BCM’s Cluster Extension cloudbursting capability ([Chapter 3 of the *Cloudbursting Manual*](/cloudbursting/cexcloud)) to extend the cluster when there are too many jobs for the local cluster. The extension to the cluster is made to a public cloud provider, such as AWS or Azure. For this case, the users can use the `cmjob` utility ([section 4.7 of the *User Manual*](/user/workloadmanagement#47-running-jobs-in-cluster-extension-cloud-nodes-using-cmjob), and [section 4.3 of the *Cloudbursting Manual*](/cloudbursting/clicloud#43-submitting-jobs-with-cmjob-and-cloud-storage-nodes-for-cluster-extension-clusters)) to submit their cloud jobs, and Slurm `sbatch` for their regular jobs. The `cm-scale` service then tracks the Slurm queues, and decides whether or not new cloud nodes should be added from the cloud as extensions to the local network and queues. When the jobs are finished, then the cloud nodes are terminated automatically. Cluster extension typically takes several minutes from prepared images, and longer if starting up from scratch, but in any case this change takes longer than simple re-purposing does.

4. An organization runs PBS Professional only and would like to power down free, local, physical nodes automatically, and start up such nodes when new jobs come in, if needed. In this case, `cm-scale` follows the queues and decides to stop or to start the nodes automatically depending on workload demand. Nodes typically power up in several minutes, so this change takes longer than simple re-purposing does.

### 8.1.2  Resource Constraints

1. Two workload manager engines of the same kind cannot be served by `cm-scale` on the same cluster. For example, two Slurm instances cannot be managed, but Slurm and LSF can. Two different Kubernetes instances count as two engines of a different kind.

2. When the service considers whether or not the node is suited for the workload, it considers the following requested resources:

   1. the number of CPU cores;

   2. the number and type of GPUs;

   3. the amount of memory.

3. and, for Kubernetes, the following additional resources:

   1. pods;

   2. ephemeral storage;

   3. extended resources.

   Other types of resources are not considered.

   An extended resource is considered by `cm-scale` if the administrator adds it to the `KUBE_EXTENDED_RESOURCES` list in `config.py`. For example:

   **Example**

   ```bash
   opts: dict[str, Any] = {
     ...
     KUBE_EXTENDED_RESOURCES": ["fpga"],
   }
   ```

   For HPC workload engines that are unsupported by `cm-scale`, the resources validation is carried out by the HPC engine. If a resource that is requested by the workload cannot be provided by the node, then the HPC engine specifies a pending reason. The pending reason is used by `cm-scale` to decide on node operations.

   For Kubernetes, all the used resources must explicitly be specified as extended resources.

   When the Kubernetes engine is configured, then `cm-scale` uses the `maxPods` value from the kubelet role as a maximum for the available pod slots per node.

   The `parallelism` parameter in the job definition YAML sets the number of pod copies to start. If a Kubernetes job sets the `parallelism` parameter, then `cm-scale` tries to find nodes to satisfy the number of pod copies for the job. The metric `kube_job_spec_parallelism` ([here](/admin/metricshealthchecksactions#g114-kubernetes-metrics)) tracks the `parallelism` value for a job.

In `cmsh`, the `wlmresources` command displays the resources that Auto Scaler considers.

**Example**

```bash
[root@basecm10 ~]# cmsh
[basecm10]% device
[basecm10->device]% wlmresources
WLM      Name              Amount         Nodes
-------- ----------------- -------------- ----------------
pbspro   cpu_total         32             node001..node006
pbspro   gpu_free          1              node005
pbspro   gpu_free          2              node001..node00+
pbspro   mem_free          8,108,032,000  node004,node005
pbspro   mem_free          948,224,000    node006
slurm    cpu_alloc         2              node001..node006
slurm    cpu_total         16             node006
slurm    cpu_total         8              node001..node005
slurm    gpu_free          1              node005
slurm    gpu_free          2              node001..node004
slurm    mem_free          1,000,000,000  node006
slurm    mem_free          380,000,000    node004
slurm    mem_free          6,778,000,000  node005
slurm    mem_free          7,257,000,000  node001..node003
uge      cpu_total         32             node001..node00+
uge      gpu_free          1              node005
uge      gpu_free          2              node001..node00+
uge      mem_free          0              node001..node003
uge      mem_free          1,396,000,000  node004
uge      mem_free          7,456,000,000  node005
uge      mem_free          990,900,000    node006
uge      mem_free_per_cpu  1,396,000,000  node004
uge      mem_free_per_cpu  990,900,000    node006
[basecm10->device]%
```

These resources are taken from the workload managers, and are not necessarily equal to the available physical resources on the nodes.

#### 8.1.2.1  Number Of CPU Cores Calculation

The `cm-scale` service uses the number of CPU cores on a node in order to decide on whether a workload should run on the node. The calculation of this number is optimized for many node scenarios.

For each node, at the beginning of each `cm-scale` iteration, the following procedure is followed step-by-step to determine the CPU cores number. The procedure for the current iteration stops when a step yields a non-zero value, otherwise the next step is tried.

1. If the engine is a workload manager, then the workload manager client role is considered and its slots parameter is used. In the very unusual case of several workload manager roles assigned to the node at the same time, then the minimum number of slots is calculated.

2. If the node is a cloud node, then its flavor `Type` parameter in the case of EC2, or `VMSize` in case of Azure, is used. These parameters are accessible via `cmsh`, within `device` mode for the cloud node, within the `cloudsettings` submode. For EC2 nodes the flavor value (`Type`) can be set to a long statement such as: "62 EC2 Compute Units (16 virtual cores with 3.00 EC2 Compute Units each)", and for this statement 16 is used as the number of CPU cores. If the flavor is not defined on the node, then its cloud provider is considered.

3. If a template node ([here](#8222-dynamic-node-provider)) is defined in the dynamic node provider, and it is a cloud node, then the template node flavor is used for the CPU core number in the same way as shown in the preceding step.

4. If the `Default Resources` parameter (in a resource provider) contains `cpus=N`, where `N` is a number of CPU cores, then `N` is used.

5. If the node exists at this moment (for example, it is not just cloned in BCM), then the CPU cores number is requested from CMDaemon, which collects nodes system information. This is used as one of the last methods because it is slow.

6. If the node is defined in the `ScaleServer` role via the dynamic resource provider, then the CPU cores number is retrieved from its template node. This method is as slow as the preceding method. It is therefore not recommended when many nodes are managed by `cm-scale`, otherwise the iteration can take several minutes. In such a case, setting the slots parameter manually is typically wiser, so that step 1 is the step that decides the CPU cores number.

If `cm-scale` does not manage to find a value for the node, then it prints a warning in the log file and does not make use of the node during the iteration. It is usually wise for the administrator to set the slots parameter manually for nodes that otherwise persistently stay unused, so that resources are not wasted.

#### 8.1.2.2  Requested GPUs

When a user of a workload manager requests a number of GPUs for the job that is to be run, then `Auto Scaler` presents nodes that have enough available GPUs for this job. For Slurm, in addition to the number of GPUs, Auto Scaler recognizes the GPU type if the user specifies it. For other workload managers only the number of GPUs is counted.

Auto Scaler knows from CMDaemon via the workload manager what GPUs and what types are available for that workload manager. Auto Scalar tracks the number of GPUs in use, or whether the administrator has configured fewer GPUs than the node actually has. Auto Scaler is therefore aware of what GPUs the workload managers can use during their job scheduling.

If debug messages are enabled in `ScaleServer` role. then the number and type of requested GPUs, as well as the number and types of available GPUs, can be found in the log file at `/var/log/cm-scale.log`

#### 8.1.2.3  Requested Memory

A memory request is considered by Auto Scaler if a user specifies this request when the job is submitted.

For Kubernetes, if a job or a pod defines a limit, then `cm-scale` uses that limit. If a limit is not set, then Kubernetes limits are followed.

For Slurm, if no memory requirement is specified by the job, then Slurm often sets its own defaults, and `cm-scale` then uses those implicit values.

GE does not provide the amount of memory requested by a user per node, but allocates memory per CPU core. Thus, Auto Scaler by default operates with a memory amount per CPU core, which can also be seen in the logs.

#### 8.1.2.4  Default Resources Specification

Sometimes the available consumable resources must be defined explicitly by the administrator. This is needed in the case of LSF, because when a node is down, LSF does not provide the available consumable resources configured for the node. Therefore in this case Auto Scaler does not know if the node actually has any of the resources known to LSF. The mechanism used for defining explicitly can also be used for other workload managers, for testing purposes.

For now, only the following types of consumable resources can be specified as default resources to the `Default Resources` setting, under the `Resource Provider` parameter. The setting is a list of strings, where each string specifies one of the following resources:

1. `cpus`: the number of CPU cores that will be used, if other sources for this information do not provide a value (the calculation for the number of CPU cores is described [here](#8121-number-of-cpu-cores-calculation))

2. `mem_free`: the amount of available memory. If no units are specified, then bytes are assumed. It is also possible to append one of the following units:

   * KB or K (kilobytes), KiB (kibibytes)

   * MB or M (megabytes), MiB (mebibytes)

   * GB or G (gigabytes), GiB (gigibytes)

   * TB or T (terabytes), TiB (tebibytes)

   * PB or P (petabytes), PiB (pebibytes)

   The format of the memory specification is the following:

   `mem_free:` \<*engine*>`=<`*amount*>

   where \<*engine*> is the name of the workload engine which "provides" this value, and \<*amount*> is the amount of memory.

   **Example**

   `mem_free:lsf1=32GB`

3. `gpu_free`: the number of available GPUs. The format of the GPUs specification is:

   `gpu_free[:` \<*type*>`]:<`*engine*>= \<*number*>

   where \<*`type`*> is a string that specifies the GPUs type (available only for Slurm). Only a single GPU type per node is currently supported. \<*number*> is a number of GPUs, and \<*engine*> is the name of the workload engine which "provides" this value.

   **Example**

   `gpu_free:a100:slr=8`

   or

   `gpu_free:lsf=1`

### 8.1.3  Setup

In order to set up Auto Scaler the administrator can run the `cm-auto-scaler-setup` script. The setup allows one of the three base scenarios to be configured. This is possible in express mode as well as in step-by-step mode. When the setup is complete, the administrator can further tune the behaviour of Auto Scaler within the `ScaleServer` role. The `Scaleserver` role is always assigned to the head nodes, via a new configuration overlay named `autoscaler`.

The setup tool assigns the role. The role, in turn, starts the `cm-scale` system service (Auto Scaler). Auto Scaler can be disabled by running `cm-auto-scaler-setup` again, and selecting the menu item `Disable`. When Auto Scaler is disabled, the configuration overlay is removed.

The service writes logs to `/var/log/cm-scale.log`. Running the `cm-scale` daemon in the foreground for debugging or demonstration purposes is also possible, using the `-f` option. Other additional options that may be used, including at the same time, are:

* `-d`: debug logs

* `-i <N>`: number (`<N>`) of iterations

The logs are then duplicated to STDOUT:

**Example**

```bash
root@basecm10$ module load cm-scale
root@basecm10$ cm-scale -f
[...]
```

When `cm-auto-scaler-setup` is started the administrator can select from one of the following setup operations (figure [8.1](#fig-auto-scaler-setup-operations)):

* express setup,

* step-by-step setup,

* disable.

![Auto Scaler Setup Operations](/base-command-manager/product-manuals/_fern-img/441e91ab513c4853cda4218f080f9d12faa96b6ea47bd4c3a95aca6d9175dcdd.webp)

*Figure 8.1: Auto Scaler Setup Operations*

* Express setup allows an initial setup to be carried out, without many questions being asked. It applies default values whereever possible. Some inputs that do not have default values are still needed. Express setup is a good start for the administrators who have never used Auto Scaler before.

* Step-by-step setup allows an initial setup to be carried out too, but with some more questions to help tune the cluster to the needs of the administrator. This is more suitable for administrators with some experience in Auto Scaler configuration.

After the wizard has carried out the deployment, both the express and the step-by-step configuration can have their configurations tuned further via `cmsh`, within the `scaleserver` role.

Express setup and step-by-step setup both allow one of the 4 pre-defined use case scenarios to be selected (figure [8.2](#fig-auto-scaler-setup-express-scenarios)):

![Auto Scaler Setup Scenario Selection](/base-command-manager/product-manuals/_fern-img/f49788775f308c184c6df6821992e18c776c102bb00ec63cbb5b3f6bad05ace9.webp)

*Figure 8.2: Auto Scaler Setup Scenario Selection*

These use cases are:

1. **Workload Manager (On-premises)**: Auto Scaler tracks selected workload manager queues, and starts or stops specified on-premises nodes on demand. A static node provider is automatically added to the role for this scenario.

2. **Workload Manager (Cluster Extension)**: Auto Scaler dynamically clones nodes from a cloud template node, on demand. The nodes can be terminated or stopped when idle. This scenario is used when cloudbursting is set up, and there is a cloud director. A dynamic node provider is added automatically to the role for this scenario.

3. **Workload Manager (Cluster in Cloud)**: As in the preceding use case, Auto Scaler dynamically clones nodes from a cloud template node, on demand. In this scenario, there is no cloud director, and the entire cluster must reside in the cloud.

4. **Kubernetes (On-premises)**: Auto Scaler tracks Kubernetes jobs or individual pods, and starts or stops the nodes on demand. A static node provider is automatically added to the role for this scenario.

Static nodes and dynamic nodes providers are discussed in section [8.2.2](#822-resource-providers).

In step-by-step mode, for the next step, the dialog suggests specifying Auto Scaler base options (figure [8.3](#fig-auto-scaler-setup-base-options)):

![Auto Scaler Setup Base Options](/base-command-manager/product-manuals/_fern-img/c7a7d4211b957e7dd6a669a86050243dca8d56c43c23b2c9391acb970dc22ad1.webp)

*Figure 8.3: Auto Scaler Setup Base Options*

The Auto Scaler base options are:

* `Enable debug messages`: Auto Scaler adds debug messages to its log file (default: `/var/log/cm-scale`).

* `Dry run mode`: Disables actual execution of any operation on the cluster. Auto Scaler decisions are still all written to the log file.

* `Run interval`: Number of seconds that Auto Scaler waits before making new decisions regarding cluster auto scaling.

#### 8.1.3.1  Use Case: Workload Manager (On-premises)

When this scenario is selected, then the next step is to configure the static nodes provider. First, categories and individual nodes to be managed by Auto Scaler are selected. The nodes of a selected category, or individual nodes, are added to the node provider (figures [8.4](#fig-auto-scaler-setup-static-categories) and [8.5](#fig-auto-scaler-setup-static-nodes)):

![Auto Scaler Setup Categories Selection For Static Node Provider](/base-command-manager/product-manuals/_fern-img/4f329bc4dae3a92e263e87a4e4df86ea7170839ffbb0a61bc577fdb7ba867304.webp)

*Figure 8.4: Auto Scaler Setup Categories Selection For Static Node Provider*

![Auto Scaler Setup Individual Nodes Selection For Static Node Provider](/base-command-manager/product-manuals/_fern-img/ef2ee409817a4be9f13d6132098909b711b9bb793ee5fb8a185ffec3c8aa2439.webp)

*Figure 8.5: Auto Scaler Setup Individual Nodes Selection For Static Node Provider*

The next step is to pick the workload manager cluster (figure [8.6](#fig-auto-scaler-setup-static-wlm)):

![Auto Scaler Setup Workload Manager Selection](/base-command-manager/product-manuals/_fern-img/dc27937e660421820eb13ba9b9c1c497597992ec052b0b81a2854f4df25071af.webp)

*Figure 8.6: Auto Scaler Setup Workload Manager Selection*

If only one workload manager instance exists, then the screen is skipped. The screen provides a list of workload manager names that `cm-wlm-setup` has set up. The `cm-auto-scaler-setup` wizard only configures one workload manager cluster, but others can be added later as separate workload engines with the `ScaleServer` role.

If running express mode, then the summary screen is displayed. The summary screen includes options to just show the configuration file, or to save the configuration and deploy the setup (figure [8.7](#fig-auto-scaler-setup-summary)):

![Auto Scaler Setup Summary](/base-command-manager/product-manuals/_fern-img/bfd5dea1a07b762a6698b7c8f607dd30a725d1f123ef387417d0c867f61e2cec.webp)

*Figure 8.7: Auto Scaler Setup Summary*

If running step-by-step mode for the workload manager, then there are some additional tune up screens:

Values can be set for resources in the default node resources screen (figure [8.8](#fig-auto-scaler-setup-default-resources)):

![Auto Scaler Setup Default Resources](/base-command-manager/product-manuals/_fern-img/25418fc737f33ed76dd6360be315f62ea04caa2cc30eef7c9ff9d70c5f7180d8.webp)

*Figure 8.8: Auto Scaler Setup Default Resources*

Resources that can be set are:

1. number of CPU cores per node. Format: \<*number*>

2. number (and optionally, type) of GPUs per node. Format: `[` \<*type*>`]:<`*number*>

3. available memory for jobs per node. Units can be specified as: KB, K, KiB, MB, M, MiB, GB, G, GiB, TB, T, TiB, PB, P, PiB. Format: \<*amount*>`[<`*unit*>]. If no units are specified, then bytes are assumed.

When Auto Scaler considers whether or not the node is suited for the workload, it considers the following requested resources:

In `cmsh`, the `wlmresources` command, executed in `devices` mode, displays the resources that Auto Scaler considers. These resources are taken from the corresponding workload manager, and are not necessarily equal to the available physical resources on the nodes. Sometimes the available consumable resources must be defined explicitly by the administrator. This is needed if the node never started, or if the WLM (such as in the case of LSF) does not provide node resource information when the node is down. It is recommended that these values are always defined. If nodes vary in their resource requirements, then, after setup, an administrator can add new resource providers (within the `ScaleServer` role) and set the various default resources for the various groups of nodes.

In the next screen the administrator can specify some WLM engine settings (figure [8.9](#fig-auto-scaler-setup-engine-settings)):

![Auto Scaler Setup Engine Settings](/base-command-manager/product-manuals/_fern-img/79a843189e5c2c85e1069979c221bc66e24a06b67e564ae9aa242aadc9f8ab4d.webp)

*Figure 8.9: Auto Scaler Setup Engine Settings*

The settings are:

* `Engine Priority`: The workload engine priority. This value is used when the final (global) workload priority is calculated by Auto Scaler. If `0`, then this priority is not taken into account.

* `Workloads Per Node`: The maximum number of WLM jobs that can be started on a node.

Auto Scaler fetches the workload priority values from the settings specified in the next screen (figure [8.10](#fig-auto-scaler-setup-workload-prio)):

![Auto Scaler Setup Workload Priorities Source Selection](/base-command-manager/product-manuals/_fern-img/d637fdbc70cd6d87eb344d8146d1b8e9d2ba9188a1a78d1379f86fb73d4392ce.webp)

*Figure 8.10: Auto Scaler Setup Workload Priorities Source Selection*

The settings are:

* `Fetched`: Priorities are fetched from workload engine. Age and engine priorities are ignored. This option sets the age factor to `0.0`, and engine priority to `0`

* `Calculated`: Priorities are calculated from the workload age and engine priority. Both can be tuned by the administrator in `ScaleServer` role. This option sets the age factor to `1.0`, and the external priority factor to `0.0`

Workload trackers settings can be set in the next screen (figure [8.11](#fig-auto-scaler-setup-tracker-settings)):

![Auto Scaler Setup Tracker Settings](/base-command-manager/product-manuals/_fern-img/55b26d2124c43c34074f1010dc8627105ab36294f5d97f580b073d11f0cb45af.webp)

*Figure 8.11: Auto Scaler Setup Tracker Settings*

The settings are:

* `Queue Length Threshold`: Number of pending workloads. If this number is reached, then nodes are triggered to start up.

* `Age Threshold`: Workload pending time threshold, in seconds. If a workload reaches this age while pending, then nodes are triggerd to start up for that workload.

* `Workloads Per Node`: The maximum number of WLM jobs that can be started on a node for that tracker. A value of `0` means no limit is set.

The settings are applied to all configuring queue trackers. The values can be tuned further afterwards in the `ScaleServer` role.

#### 8.1.3.2  Use Case: Workload Manager (Cluster Extension)

In the case of workload manager cluster extension scenario, a dynamic node provider with a template node is configured. In this scenario the administrator should expect cloud nodes to be triggered, which run in a previously configured and deployed cluster extension.

Cluster extension configuration and deployment in BCM is described in [Chapter 3 of the *Cloudbursting Manual*](/cloudbursting/cexcloud), and can be carried out, for example, for a particular cloud provider. For command line deployment, the `cm-cluster-extension` setup script can be run.

Cloud nodes are thus cluster nodes that extend into a cloud provider, and which are cloned and terminated depending on workload demand.

To configure a cluster extension with Auto Scaler, the administrator is asked to pick a cloud provider (figure [8.12](#fig-auto-scaler-setup-cloud-provider)):

![Auto Scaler Setup Cloud Provider](/base-command-manager/product-manuals/_fern-img/ef3075c42931212d0599abe7aba001afbb60b12e6baa329e7c5524062cb49a61.webp)

*Figure 8.12: Auto Scaler Setup Cloud Provider*

With the express setup, the next screen asks for workload manager selection (figure [8.6](#fig-auto-scaler-setup-static-wlm)).

With the step-by-step setup, however, some additional screens are presented before getting to the workload manager selection screen. These extra screens are described next.

The Auto Scaler template node selection screen (figure [8.13](#fig-auto-scaler-setup-template-node)) prompts for the selection of a template node that is to be used for cloud node cloning.

![Auto Scaler Setup Template Node](/base-command-manager/product-manuals/_fern-files/nvidia-bcm-manuals.docs.buildwithfern.com/5f700065cd6e656e8dfe59cab822c90e56e011d2d199e653a83ca492c2f9c2e4/_dot_dot_/_dot_dot_/_dot_dot_/_dot_dot_/_dot_dot_/_dot_dot_/tmp/tmp-465-AR0SE6FbhiT1/latextofern/fern/assets/v10/figures/auto-scaler-setup-template-node.png)

*Figure 8.13: Auto Scaler Setup Template Node*

The selected template node is then set in the dynamic node provider.

The Auto Scaler incrementing network interface screen (figure [8.14](#fig-auto-scaler-setup-net-interface)) prompts the administrator to select the network interface on the template node that is automatically incremented when the node is cloned.

![Auto Scaler Setup Incremented Network Interface Selection](/base-command-manager/product-manuals/_fern-img/d6b0de1dbfd078339e8608a394c164f76a7942d3d8b969d5d2ce69aee4335509.webp)

*Figure 8.14: Auto Scaler Setup Incremented Network Interface Selection*

The Auto Scaler node range specification screen (figure [8.15](#fig-auto-scaler-setup-node-range)) prompts the administrator to specify a node range. Range format can be used. Nodes are automatically created by Auto Scaler on demand in the cloud according to the range specified.

![Auto Scaler Setup Node Range](/base-command-manager/product-manuals/_fern-img/ca9f22c31fc360b1171730468de43edd451ea6855dfc600b72020ac161fb5ffe.webp)

*Figure 8.15: Auto Scaler Setup Node Range*

The remaining screens in this use case have been covered in the earlier section (**Use Case: Workload Manager (On-premises)**, [here](#8131-use-case-workload-manager-on-premises)) , and are:

* default node resources (figure [8.8](#fig-auto-scaler-setup-default-resources)),

* engine settings (figure [8.9](#fig-auto-scaler-setup-engine-settings)),

* workload priorities (figure [8.10](#fig-auto-scaler-setup-workload-prio)),

* tracker settings (figure [8.11](#fig-auto-scaler-setup-tracker-settings)).

#### 8.1.3.3  Use Case: Workload Manager (Cluster in Cloud)

If a workload manager (Cluster in Cloud) option is chosen from figure [8.2](#fig-auto-scaler-setup-express-scenarios), then the screens that are displayed next follow the same steps as in the preceding case of a workload manager (Cluster Extension) (starting at [here](#8132-use-case-workload-manager-cluster-extension)).

#### 8.1.3.4  Use Case: Kubernetes (On-premises)

If a Kubernetes (On-premises) scenario is chosen from figure [8.2](#fig-auto-scaler-setup-express-scenarios), and if Kubernetes has been set up ([Chapter 4 of the *Containerization Manual*](/containerization/kubernetes)) then the screens that are displayed next are related to Kubernetes and Auto Scaler integration. Auto Scaler tracks Kubernetes jobs or individual pods, and can start or stop the on-premises nodes on demand.

The first screen displayed after the scenario is selected, is a screen that asks for node categories and individual nodes that are to be configured in the static resource provider. Such nodes are the only ones to be managed by Auto Scaler. Category and node selection screens are then displayed as in the earlier sections (figures [8.4](#fig-auto-scaler-setup-static-categories) and [8.5](#fig-auto-scaler-setup-static-nodes)).

The administrator is then prompted to select a Kubernetes cluster (figure [8.16](#fig-auto-scaler-setup-kube)).

![Auto Scaler Setup Kubernetes Cluster Selection](/base-command-manager/product-manuals/_fern-img/4c6e62fc45fc73b256df67b6a10e437bc9f5e87afdb172f62d2e93adfd7dcd27.webp)

*Figure 8.16: Auto Scaler Setup Kubernetes Cluster Selection*

If there is only one Kubernetes cluster, then this screen is skipped, and the Kubernetes configuration is used for the integration with Auto Scaler.

The next screen prompts for the Kubernetes engine settings (figure [8.17](#fig-auto-scaler-setup-kube-settings)):

* `Engine Priority`: A workload engine priority. This value is used when the final (global) workload priority is calculated by Auto Scaler. If `0`, then this priority is not taken into account.

* `Workloads Per Node`: The maximum number of Kubernetes jobs, or individual Kubernetes pods without a controller, that can be started on a node.

* `CPU Busy Threshold`: The CPU load % that defines if node is too busy for new pods.

* `Memory Busy Threshold`: The Memory load % that defines if node is too busy for new pods.

![Auto Scaler Setup Kubernetes Engine Settings](/base-command-manager/product-manuals/_fern-img/c30b07bfb6b0ff412da00341edff036f4891fe087bc3f567ef0a93bd18aaed4c.webp)

*Figure 8.17: Auto Scaler Setup Kubernetes Engine Settings*

The administrator is then prompted to pick the Kubernetes namespace that will be tracked by Auto Scaler (figure [8.18](#fig-auto-scaler-setup-kube-namespace)):

![Auto Scaler Setup Kubernetes Namespace Selection](/base-command-manager/product-manuals/_fern-img/87ff58573d40ea29e050e510eb5eb78dd4519d8d36b01e6bace2a59a473bdc60.webp)

*Figure 8.18: Auto Scaler Setup Kubernetes Namespace Selection*

In step-by-step mode, the namespace tracker settings are then displayed (figure [8.18](#fig-auto-scaler-setup-kube-namespace)):

![Auto Scaler Setup Kubernetes Namespace Tracker Settings](/base-command-manager/product-manuals/_fern-img/62ae516d31456d2408863bf7279e21d31fa07308f442ff6d87b2f87ce2df0b95.webp)

*Figure 8.19: Auto Scaler Setup Kubernetes Namespace Tracker Settings*

The settings are:

* `Queue Length Threshold`: If this number of pending workloads is exceeded, then that triggers nodes starting up.

* `Age Threshold`: Workload pending time threshold, in seconds. If the age of the workload is greater than this, then nodes are triggered to start for this workload.

* `Workloads Per Node`: The maximum number of Kubernetes jobs, or individual Kubernetes pods without a controller, that can be started on a node for that namespace tracker. A value of `0` means no limit is set.

The settings are applied to all configuring namespace trackers. The values can be tuned further afterwards within the `ScaleServer` role.

The summary screen is displayed next (figure [8.7](#fig-auto-scaler-setup-summary)). Selecting `Save config & deploy` saves the configuration and starts the setup procedure.

### 8.1.4  Workload Roles Assignment Limitations Per Node With `cm-scale`

The `cm-scale` service allows multiple workload managers to be considered on the same cluster, and besides supporting HPC workload managers, also supports Kubernetes as a type of workload engine.

However, more than one engine role should not be assigned to a node at one time. Thus, for example, assigning a Slurm role and a PBS role at the same time to a node should not be done. Nor, for example, should there be a Kubernetes role and a workload management role assigned at the same time to a node.

## 8.2  Configuration

### 8.2.1  The ScaleServer Role

To configure `cm-scale`, the cluster administrator configures the `ScaleServer` role. The role is typically assigned to head nodes:

**Example**

```bash
[basecm10]% device use master
[basecm10->device[basecm10]]% roles
[basecm10->device[basecm10]->roles]% assign scaleserver
```

The role is configured by setting values to its settings. There are some advanced settings for less common options:

```bash
[basecm10->device*[basecm10*]->roles*[scaleserver*]]% show
Parameter                        Value
-------------------------------- ------------------------------------------------
Name                             scaleserver
Revision
Type                             ScaleServerRole
Add services                     yes
Engines                          <0 in submode>
Resource Providers               <0 in submode>
Dry Run                          no
Debug                            no
Run Interval                     120
Advanced Settings                <submode>
[basecm10->device*[basecm10*]->roles*[scaleserver*]]% advancedsettings
[basecm10->device*[basecm10*]->roles*[scaleserver*]->advancedsettings*]% show
Parameter                        Value
-------------------------------- ------------------------------------------------
Debug2                           no
Max Threads                      16
Power Operation Timeout          30
Connection Retry Interval        5
Log File                         /var/log/cm-scale.log
Pin Queues                       no
Mix Locations                    yes
Failed Node Is Healthy           no
Azure Disk Image Name            images
Azure Disk Container Name        vhds
Azure Disk Account Prefix
Node Selection                   Alphabetically
Node Selection Uptime Period     2w
```

The advanced settings are:

* `Debug2`: Enable printing very low level debug messages in the log file. This setting must be used with caution because it leads to a rapid increase in the log file size.

* `Max Threads`: Maximum number of threads for sequential RPCs to CMDaemon.

* `Power Operation Timeout`: Power operation RPC timeout, in seconds.

* `Connection Retry Interval`: Connection to CMDaemon retry interval, in seconds.

* `Log File`: Path to the log file (Default `/var/log/cm-scale.log`).

* `Pin Queues`: Pin workloads to their queue nodes.

* `Mix Locations`: Allow workload to be be offered to different locations (cloud and local).

* `Failed Node Is Healthy`: Do not start a new node instead of a failed one.

* `Azure Disk Image Name`: Image name for Azure disks.

* `Azure Disk Container Name`: Container name for Azure disks.

* `Azure Disk Account Prefix`: Prefix for randomly-generated Azure disk account names.

* `Node Selection`: Type of node selection used by Auto Scaler. The values this can take are:

  * `Alphabetically`: This means that Auto Scaler picks next node to start according the node name.

  * `Randomly`: This means that the nodes are picked randomly, which helps make the node usage more even.

  * `Uptime`: This means that the nodes that have been used the least amount of time are picked first.

* `Node Selection Uptime Period`: If `Node Selection` is set to `uptime`, then the `Node Selection Uptime Period` is the time period from now into the past, over which Auto Scaler calculates the total uptime for nodes. So, with the default setting of `2w` this means that the uptime of nodes is calculated over the last 2 weeks.

An overview of the parameters and submodes is given next. An example showing how they can be configured is given afterwards, in section [8.3](#83-examples-of-cm-scale-use).

#### 8.2.1.1  ScaleServer Role Global Parameters

The `ScaleServer` role has the following global parameters for controlling the `cm-scale` service itself:

* `Debug`: Print debug messages to the log.

* `Dry Run`: If set, then the service runs in dry run mode. In this mode it may claim that actions have been carried out on the nodes that use the `cm-scale` service, however, no action is actually carried out on nodes. This mode is useful for demonstration or debug purposes

* `Run Interval`: interval, in seconds, between `cm-scale` decision-making

#### 8.2.1.2  ScaleServer Role Submodes

Within the `ScaleServer` role are the following three submodes:

* `advancedsettings`: allows some advanced properties to be set for `cm-scale`, using the parameters displayed [here](#821-the-scaleserver-role).

* `resourceproviders`: defines the nodes used by `cm-scale`. More explicitly, this submode is used to define resource provider objects. The resource providers can be added as `static` or `dynamic` types, and can then have nodes and settings defined within them. The nodes allocated to these resource provider objects are what provide resources to `cm-scale` when that resource provider is requested.

* `engines`: define the engines used by `cm-scale`. This can be an instance of the type `hpc`, `generic`, or `kubernetes` ([here](#825-engines)).

  * `trackers` (within `engines` submode): define the trackers used by `cm-scale` ([here](#826-trackers))

The parameters are enforced only when the next decision-making iteration takes place.

### 8.2.2  Resource Providers

The `cm-scale` service allows nodes to change state according to the workload demand. These managed nodes are defined by the administrator within the `resourceproviders` submode of `ScaleServer`. NVIDIA Base Command Manager 10 supports two types of resource providers: `static` and `dynamic` node providers.

#### 8.2.2.1  Static Node Provider

When managed nodes are well-known and will not be extended or shrunk dynamically, then a `static` node provider can be used. Specifying settings for the `static` node provider allows `cm-scale` to power on, power off, or re-purpose nodes, based on `nodegroups` or a list of nodes `nodes` specified with a node list syntax ([here](/admin/clustermanagement#25510-node-list-syntax)).

The `static` node provider supports the following properties:

* `Enabled`: The static node provider is currently enabled.

* `Nodes`: A list of nodes managed by `cm-scale`. These can be regular local compute nodes (nodes) or cluster extension cloud compute nodes (cnodes). For the purposes of this section on `cm-scale`, these compute nodes can conveniently be called nodes and cnodes. Since compute nodes are typically the most common cluster nodes, significant resources can typically be saved by having the `cm-scale` service decide on whether to bring them up or down according to demand.

  * cnodes can be cloned and terminated as needed. Cloning and terminating saves on cloud storage costs associated with keeping virtual machine images.

  * regular local compute nodes can be started and stopped as needed. This reduces power consumption.

* `Nodegroups`: List of node groups (section [2.1.4](/admin/clustermanagement#214-node-groups)) with nodes to be managed by `cm-scale`. Node groups are classed into *types*. The class of *node group types* is independent of the class of *node types*, and should not be confused with it.

  Node types are shown in the first column of the output of the default `list` command in `device` mode ([here](/admin/clustermanagement#2521-navigation-through-modes-and-objects-in-cmsh)). The node types that can be managed by `cm-scale` are `physicalnode` and `cloudnode`.

* `Priority`: The provider priority. Nodes in the pool of a provider with a higher priority are used first by workloads. By default a resource provider has a priority value `0`. These priority values should not be confused with the fairsharing priorities [here](#824-fairsharing-priority-calculation-and-node-management).

#### 8.2.2.2  Dynamic Node Provider

When managed nodes can be cloned or removed from the configuration, then a `dynamic` node provider should be used. A compute node that is managed by `cm-scale` as a `dynamic` node provider is configured as a template node within the `dynamic` submode of the `ScaleServer` role.

The `dynamic` node provider supports the following properties:

* `Template Node`: A node that will be used as a template for cloning other nodes in the pool. The following restrictions apply to the template node:

  * A workload manager client role must be assigned with a positive number of slots.

  * New node names should not conflict with the node names of nodes in a `nodegroup` defined for the queue.

  * A specific template node is restricted to a specific queue.

  A template node only has to exist as an object in BCM, with an associated node image. A template node does not need to be up and running physically in order for it to be used to create clones. Sometimes, however, an administrator may want it to run too, like the other nodes that are based upon it, in which case the `Start Template Node` and `Stop Template Node` values apply.

  * `Start Template Node`: The template node specified in the `Template Node` parameter is also started automatically on demand.

  * `Stop Template Node`: The template node specified in the `Template Node` parameter is also stopped automatically on demand.

  An alternative to a template node is to use a snapshot ([Chapter 3.4 of the *Cloudbursting Manual*](/cloudbursting/cexcloud#34-cluster-extension-with-aws-cloud-director-and-cloud-node-startup-from-snapshots)), for greater cloud node startup speed.

* `Never Terminate`: Number of cloud nodes that are never terminated even if no jobs need them. If there are this number or fewer cloud nodes, then `cm-scale` no longer terminates them. Cloud nodes that cannot be terminated can, however, still be powered off, allowing them to remain configured in BCM. As an aside, local nodes that are under `cm-scale` control are powered off automatically when no jobs need them, regardless of the `Never Terminate` value.

* `Never Terminate Nodes`: A list of nodes specified with a node list syntax ([here](/admin/clustermanagement#25510-node-list-syntax)). These cloud nodes are never terminated, even if no jobs need them. Cloud nodes that cannot be terminated can, however, still be powered off. The nodes must already exist in the BCM configuration when `Never Terminate Nodes` is configured.

* `Enabled`: Node provider is currently enabled.

* `Priority`: Node provider priority.

* `Node Range`:  Range of nodes that can be created and managed by `cm-scale`.

* `Network Interface`: Which node network interface is changed on cloning (incremented).

* `Remove Nodes`: Should the new node be removed from BCM when the node terminates? If the node is not going to be terminated, but just stopped, then it is never removed.

* `Leave Failed Nodes`: If nodes are discovered to be in a state of `INSTALLER_FAILED` or `INSTALLER_UNREACHABLE` (section [5.5.4](/admin/provisioning#554-node-states-that-may-indicate-problems)) then this setting decides if they can be left alone, so that the administrator can decide what do with them later on.

* `Default Resources`: List of default resources, in format \[*name*=*value*].

  * `cpu`: value is the number of CPUs

  * `mem`: value is in bytes

  These must be set when no real node instance is associated with a node defined in BCM.

#### 8.2.2.3  Extra Nodes Settings For Node Providers

Both the `dynamic` and `static` node providers support extra node settings. If configured, then `cm-scale` can start the extra nodes before the first workload is started, and can stop them after the last job from the managed queue is finished.

The most common use case scenario for extra nodes in the case of cloud nodes is a cloud director node. The cloud director node provisions cloud compute nodes and performs other management operations in a cloud.

In the case of non-cloud non-head nodes, extra nodes can be, for example, a license server, a provisioning node, or an additional storage node.

The configuration settings include:

* `Extra Nodes`: A list of extra nodes.

* `Extra Node Idle Time`: The maximum time, in seconds, that extra nodes can remain unused. The `cm-scale` service checks for the existence of queued and active workloads using the extra node, when the time elapsed since the last check reaches `Extra Node Idle Time`. If there are workloads using the extra node, then the time elapsed is reset to zero and a time stamp is written into the file `cm-scale.state` under the directory set by the `Spool` role parameter. The time stamp is used to decide when the next check is to take place. Setting `Extra Node Idle Time=0` means the extra node is stopped whenever it is found to be idle, and started again whenever workloads require it, which may result in a lot of stops and starts.

* `Extra Node Start`: Extra node is started by `cm-scale` before the first compute node is started.

* `Extra Node Stop`: Extra node is stopped by `cm-scale` after the last compute node stops.

#### 8.2.2.4  Additional Settings For Node Providers

All of the node providers include the following settings that allows the Auto Scaler behavior to be tuned:

* `Keep Running`: Nodes that should not be stopped or terminated even if they are unused (range format).

* `Shutdown Before Power Off`: Shutdown nodes instead of just power off, and wait until a set timeout before doing a hard power off.

* `Shutdown Timeout`: Shutdown timeout before powering off.

* `Allocation Prolog`: Script that is executed when a node is allocated to a workload.

* `Allocation Epilog`: Script that is executed when a node is deallocated.

* `Long starting node action`: Action that is applied to a *long starting node*. A long starting node is a node that takes too long to start. Options:

  * `none` (default)

  * `power off`

  * `terminate` (applied to dynamic node provider only)

* `Long starting node timeout`: How long Auto Scaler should wait before the action is applied for a long starting node.

The following table summarizes the default attributes in `cmsh` for the resource providers, along the `cmsh` path `cmsh->device[]->roles->scaleserver->resourceproviders[dynamic/static]`:

```bash
Parameter                     static                       dynamic
---------------------------   -------------------------    ------------------------
Name                          static                       dynamic
Revision
Type                          static                       dynamic
Enabled                       yes                          yes
Priority                      0                            0
Whole Time                    0                            0
Stopping Allowance Period     0                            0
Keep Running
Extra Node
Extra Node Idle Time          1h                           1h
Extra Node Start              yes                          yes
Extra Node Stop               yes                          yes
Allocation Prolog
Allocation Epilog
Allocation Scripts Timeout    10s                          10s
Nodes                                                      N/A
Template Node                 N/A
Node Range                    N/A
Network Interface             N/A                          tun0
Start Template Node           N/A                          no
Stop Template Node            N/A                          no
Remove Nodes                  N/A                          no
Leave Failed Nodes            N/A                          yes
Never Terminate               N/A                          32
Never Terminate Nodes         N/A
Nodegroups                                                 N/A
Default Resources             cpus=1                       cpus=1
Shutdown Before Power Off     yes                          yes
Shutdown Timeout              3m                           3m
Long starting node action     None                         None
Long starting node timeout    10m                          10m
```

In the preceding table, the entry N/A means that the parameter is not available for the corresponding resource provider.

### 8.2.3  Time Quanta Optimization

*Time quanta optimization* is an additional feature that `cm-scale` can use for further cost-saving with certain cloud providers.

For instance, a cloud provider may charge per whole unit of time, or *time quantum*, used per cloud node, even if only a fraction of that unit of time was actually used. The aim of BCM’s time quanta optimization is to keep a node up as long as possible within the already-paid-for time quantum, but without incurring further cloud provider charges for a node that is not currently useful. That is, the aim is to:

* keep a node up if it is running jobs in the cloud

* keep a node up if it is not running jobs in the cloud, if its cloud time has already been paid for, until that cloud time is about to run out

* take a node down if it is not running jobs in the cloud, if its cloud time is about to run out, in order to avoid being charged another unit of cloud time

Time quanta optimization is implemented with some guidance from the administrator for its associated parameters. The following parameters are common for both `static` and `dynamic` node resource providers:

* `Whole time`. A compute node running time (in minutes) before it is stopped if no workload requires it. For example, the cloud provider may have a time quantum of 60 minutes. By default, BCM uses a value of `Whole Time`=0, which is a special value that means `Whole Time` is ignored. Ignoring it means that BCM does no time quanta optimization to try to optimize how costs are minimized, but instead simply takes down nodes when they are no longer running jobs.

* `Stopping Allowance Period`. A time (in minutes) just before the end of the `Whole Time` period, prior to which all power off (or terminate) operations must be started. The parameter associated with time quanta optimization is the `Stopping Allowance Period`. This parameter can also be set by the administrator. The `Stopping Allowance Period` can be understood by considering the *last call time period*. The last call time period is the period between the last call time, and the time that the next whole-time period starts. If the node is to be stopped before the next whole-time charge is applied, then the last call time period must be at least more than the maximum time period that the node takes to stop. The node stopping period in a cluster involves cleanly stopping many processes, rather than just terminating the node instance, and can therefore take some minutes. The maximum period in minutes allowed for stopping the node can be set by the administrator in the parameter `Stopping Allowance Period`. By default, `Stopping Allowance Period`=0. Thus, for nodes that are idling and have no jobs scheduled for them, only if the last call time period is more than `Stopping Allowance Period`, does `cm-scale` stop the node.

The preceding parameters are explained next.

Figure [8.20](#fig-time-quanta-optimization) illustrates a time line with the parameters used in time quanta optimization.

![Time Quanta Optimization](/base-command-manager/product-manuals/_fern-img/4175d36b6970d539399cc21bf7a706eb3d6774282c67ca8ef832d5c8df7d74a0.webp)

*Figure 8.20: Time Quanta Optimization*

The algorithm that `cm-scale` follows, with and without time quanta optimization, can now be described using the two parameters explained so far:

1. `cm-scale` as part of its normal working, checks every `Run Interval` seconds to see if it should start up nodes on demand or shut down idling nodes.

2. If it sees idling nodes, then:

   1. If `Whole Time` has not been set, or is 0, then there is no time quanta optimization that takes place. The `cm-scale` service then just goes ahead as part of its normal working, and shuts down nodes that have nothing running on them or nothing about to run on them.

   2. If a non-zero `Whole Time` has been set, then a time quanta optimization attempt is made. The `cm-scale` service calculates the time period until the next time quantum from public cloud starts. This time period is the current *closing time period*. Its value changes each time that `cm-scale` is run. If

      * the current closing time period is long enough to let the node stop cleanly before the next time quantum starts, and

      * the next closing time period—as calculated by the next `cm-scale` run but also running within the current time quantum—is not long enough for the node to stop cleanly before the next quantum starts

      then the current closing time period starts at a time called the *last call*.

      In drinking bars, the last call time by a bartender allows some time for a drinker to place the final orders. This allows a drinker to finish drinking in a civilized manner. The drinker is meant to stop drinking before closing time. If the drinker is still drinking beyond that time, then a vigilant law enforcement officer will fine the bartender.

      Similarly, the last call time in a scaling cluster allows some time for a node to place its orders to stop running. It allows the node to finish running cleanly. The node is meant to stop running before the next time quantum starts. If the node is still running beyond that time, then a vigilant cloud provider will charge for the next whole time period.

      The last call time is the last time that `cm-scale` can run during the current whole-time period and still have the node stop cleanly within that current whole-time period, and before the next whole-time period starts. Thus, when `Whole Time` has been set to a non-zero time:

      1. If the node is at the last call time, then the node begins with stopping

      2. If the node is not at the last call time, then the node does not begin with stopping

   The algorithm goes back again to step 1.

### 8.2.4  Fairsharing Priority Calculation And Node Management

At intervals of `Run Interval`, `cm-scale` collects workloads using trackers configured in the `ScaleServer` role, and puts all the workloads in a single internal queue. This queue is then sorted by priorities. The priorities are calculated for each workload using the following fairsharing formula:

```math

p_{ij} = k_1 \times a_i + k_2 \times b_j + k_3 \times c_j
```

where:

p\[ij] is the global priority for the i-th workload of the j-th engine. Its value is used to re-order the queue.

k\[1] is the age factor. This is the `agefactor` parameter that can be set via `cmsh` in the `engine` submode of the `ScaleServer` role. Usually it has the value `1`.

a\[i] is the age of the workload. That is, how long has passed since the i-th job submission, in seconds. This typically dominates the priority calculation, and makes older workloads a higher priority.

k\[2] is the external priority factor. It is a floating point number in the range \[0, 1], and is the`External Priority Factor` parameter that can be set via `cmsh` in the `engine` submode of the `ScaleServer` role.

b\[i] is the workload priority retrieved from the engine.

k\[3] is the engine factor. It is a floating point number in the range \[0, 1], and is the `enginefactor` parameter in the `engine` submode of the `ScaleServer` role.

c\[j] is the engine priority. This is the `priority` parameter in the `engine` submode of the `ScaleServer` role.

When all the workload priorities are calculated and the queue is re-ordered, then `cm-scale` starts to find appropriate nodes for workloads. The workloads are selected in order, from the top of the queue where the higher priority workloads are, to the bottom. This way a higher priority engine has a greater chance of getting nodes for its workloads than a lower priority engine.

The factors k\[1], k\[2] and k\[3] in the equation [8.2.4](#824-fairsharing-priority-calculation-and-node-management) allow the significance of the related priority value in the final result to be controlled. For example if only the priority fetched from the engine should be taken into account, then k\[1] and k\[3] should be set to `0`, and k\[2] to `1`. Or, for example, when both the age and engine priorities should be treated as equally important, then k\[1] and k\[3] can be set to `0.5` and k\[2] to `0`.

### 8.2.5  Engines

Each workload engine considered by `cm-scale` must be configured within the `engines` submode within the `ScaleServer` role. NVIDIA Base Command Manager 10 supports the following workload engines:

* Slurm

* PBS (OpenPBS and PBS Professional)

* LSF

* GE (Altair Grid Engine)

Engines can be of three types:

* `hpc`: for all HPC (High Performance Computing) workload managers

* `kubernetes`: for Kubernetes

* `generic`: for a generic type

#### 8.2.5.1  Common Parameters For The `cm-scale` Engines

All three engine types have the following parameters and submode in common, although their values may differ:

* `Workloads Per Node`: The number of workloads, Kubernetes jobs, or individual Kubernetes pods without a controller, that can be scheduled to run on the same node at the same time.

  * For a Kubernetes engine this parameter restricts the number of jobs or individual pods per node. It does not restrict the total number of pods that can be run per node by the `cm-scale` scheduler. The parameter is taken into consideration by the `cm-scale` scheduler when it is searching for new nodes to start up, and does not configure Kubernetes itself.

    For example, a Kubernetes job, or Job with a capital ‘J’ in Kubernetes terminology, may consist of many pods. Then, if `Workload Per Node` is, for example, 2, then only 2 Jobs are run on the node.

    The number of pods is also taken into account by `cm-scale`, but this number is taken from the `kubelet` role, where the `Max Pods` option can be set. If the role is not assigned to a node, using a configuration overlay, cateogry, or node, then `cm-scale` assumes that there is no possibility for any pods to run on the node.

* `Priority`: The engine priority

* `Age Factor`: Fairsharing coefficient for workload age

* `Engine Factor`: Fairsharing coefficient for engine priority

* `External Priority Factor`: Fairsharing coefficient for external priority significance

* `Trackers`: Enters the workload trackers submode

#### 8.2.5.2  Non-common parameters for the `cm-scale` engines:

* For the `hpc` engine:

  * `WLM Cluster`: A workload manager cluster name. The name is set during workload manager setup as the instance name. In `cmsh` the WLM cluster names are listed under `wlm` mode. In Base View they can be seen along the navigation path `HPC` > `Wlm Clusters`.

* For the `kubernetes` engine, the following parameters can be set:

  * `Cluster`: These are the Kubernetes clusters for which pods are to be tracked. BCM allows multiple Kubernetes clusters to run on a single compute cluster. Kubernetes must be already set up before this setting is configured.

  * `CPU Busy Threshold`: The CPU load is a value that can range from 0 to 1. The `CPU Busy Threshold` value defines if the node is too busy for new pods. Its default value is: `0.9`.

  * `Memory Busy Threshold`: The Memory load is a value that can range from 0 to 1. The `Memory Busy Threshold` defines if the node is too busy for new pods. Its default value is: `0.9`.

The CPU and Memory thresholds configured in the Kubernetes engine help `cm-scale` to decide when more nodes are needed. But `cm-scale` also retrieves the number of pods that are already running on the node and compares it with the `Max Pods` parameter that is configured in the `kubelet` role assigned to the node via at the configuration overlay level, category level, or node level. If the number of running pods is already equal or greater than the value of `Max Pods`, then (from the `cm-scale` point of view) the node cannot fit more pods, which means that a new node is needed.

### 8.2.6  Trackers

A workload tracker is a way to specify the workload and its node requirements to `cm-scale`. For HPC, the tracker may be associated with a specific queue, and `cm-scale` then tracks the jobs in that queue.

One or more trackers can be named and enabled within the `trackers` submode, which is located within the `engines` submode of the `ScaleServer` role. A queue (for workload managers) can be assigned to each tracker.

**Example**

There are three types of tracker objects supported in NVIDIA Base Command Manager 10:

* `queue`: Used with an HPC type engine, where each workload (job) is associated with a particular queue. The attribute `Type` takes the value `ScaleHpcQueueTracker`, and the attribute `Queue` is set to the queue name for the job.

* `namespace`: Used with a `kubernetes` type engine.

* `generic`: Used with a `generic` type engine.

The following settings are common for both types of trackers:

* `Enabled`: Enabled means that workloads from this tracker are considered by `cm-scale`.

* `Allowed Resource Providers`: Only the specified resource providers (in the scaleserver role) will be used for a workload of this tracker (if empty than all allowed).

* `Assign Category`: A node category name that should be assigned to the managed nodes. When a node is supposed to be used by a workload, then `cm-scale` should assign the node category to that node. If the node is already running, and has no workloads running on it, but its category differs from the category specified for the jobs of the queue, then the node is drained, stopped and restarted on the next decision-making iteration of `cm-scale`, and takes on the assigned category. Further details on this are given in the section on dynamic nodes re-purposing, [here](#841-dynamic-nodes-re-purposing).

* `Primary Overlays`: A list of configuration overlays.

  If a workload is associated with the tracker for which the overlays are specified by `Primary Overlays`, then BCM-managed nodes are appended to those configuration overlays by `cm-scale`. This takes place after the node is removed from the previous overlays that it is associated with.

  If the node is already running, but has not yet been appended to the overlays specified for the workloads of the tracker, then the node is restarted when no other workloads run on the node, before going on to run the workloads with the new overlays.

  * When a workload is associated with the tracker that has `Primary Overlays` set, then the pool of `cm-scale`-managed nodes is checked.

    The check is to decide on if a node is to be made available for the workload.

    If the node is appended to the `Primary Overlays` already and is not running workloads, then `cm-scale` simply hands over a workload from the tracker to run on the node.

    If the node is not appended to the `Primary Overlays` already, and is not running workloads, then `cm-scale` prepares and boots the node as follows:

    * the node is drained and rebooted if it is up, or

    * the node is undrained and merely booted if it is not up

    The node is removed from any previous overlays that it was with, before booting up, and it is appended to the new overlays of `Primary Overlays`.

* The threshold settings:

  * `Queue Length Threshold`: number of pending workloads that triggers cloudbursting.

  * `Age Threshold`: workload pending time threshold, in seconds, that triggers cloudbursting for this workload.

  The queue length and age thresholds allow the administrator to set when `cm-scale` starts or creates cloudbursting nodes. Both thresholds can be used at the same time, or just one of them can be used and the other can be ignored by setting it to `0`.

  If the queue length threshold is set, then `cm-scale` ignores pending workloads that are located higher (added later) than the threshold in the managed queue.

  **Example**

  Assuming there are 5 jobs in the queue, with job IDs 1, 2, 3, 4, and 5, where the 1st one is the first in the queue. If the queue length threshold is 3, then only jobs 1, 2 and 3 are taken into account, while jobs 4 and 5 are ignored.

  **Example**

  If the age threshold is set to `100`, then only workloads older than 100 seconds are taken into account, while younger jobs are ignored.

The `queue` type tracker has only one parameter specific to the tracker: `Queue`. This is set to the workload queue that is being tracked.

#### 8.2.6.1  Namespace Tracker

The namespace tracker of `cm-scale` is used to track Kubernetes workloads. It tracks Kubernetes jobs (via its Job controllers) and tracks individual pods. It does not start new nodes for pending pods owned by other types of Kubernetes pod controllers, such as ReplicaSet, DaemonSet, and so on. If non-Job controllers are running, then `cm-scale` will not stop or terminate those nodes.

The tracker settings in `cmsh` or Base View include additional parameters that are in common with other trackers:

1. `Controller Namespace`: Tracks the Kubernetes namespace name. Only Kubernetes workloads from this namespace are tracked. To track more than one namespace, one tracker must be created per namespace.

2. `Object`: Type of Kubernetes objects to track. BCM supports the following object types:

   1. `Job`: A Kubernetes Job controller type represents one or several pods that are expected to eventually terminate. The controller nature makes this type of Kubernetes workload very suited to dynamic data centers.

   2. `Pod`: Individual pod, without any controller.

If the specified namespace does not exist in Kubernetes, then the tracked jobs or individual pods in this namespace are ignored by `cm-scale`.

#### 8.2.6.2  Generic Engine And Tracker

The `cm-scale` service is able to deal with workloads that use various workload types. In order to add suuport of a new type of workload, the administrator

* adds an engine of type `generic`

* adds one or more trackers of type `generic` to the ScaleServer role

* implements Tracker and Workload classes in the Python programming language

When `cm-scale` starts a new iteration, it re-reads the engines and trackers settings from the `ScaleServer` role, and searches for the appropriate modules in its directories. In the case of a custom tracker, the module is always loaded according to the tracker handler path. When the tracker module is loaded, `cm-scale` requests a list of workloads from each of the tracker modules. So, the aim of the tracker module is to collect and provide the workloads to `cm-scale` in the correct format.

The path to the tracker module should be specified in the handler parameter of the generic tracker entity using `cmsh` or Base View as follows:

**Example**

```bash
[root@basecm10 ~]# cmsh
[basecm10]% device roles master
[basecm10->device[basecm10]->roles]% use scaleserver
[basecm10->device[basecm10]->roles[scaleserver]]% engines
...->roles[scaleserver]->engines]% add generic myengine
...*]->roles*[scaleserver*]->engines*[myengine*]]% trackers
...*[myengine*]->trackers]% add generic mytracker
    ...*[mytracker*]]% set handler /cm/local/apps/cm-scale/examples/custom_tracker/tracker.py
...*]->roles*[scaleserver*]->engines*[myengine*]->trackers*[mytracker*]]% commit
...->roles[scaleserver]->engines[myengine]->trackers[mytracker]]%
```

In the preceding example, the handler file `.../examples/tracker.py` is an example that is provided with the `cm-scale` package. Another example module file provided with the package is `.../examples/workload.py`, which implements the `ExampleWorkload` class. Together, the two examples can be used to generate any amount of simple workloads during each `cm-scale` iteration. It is recommended to use the tracker and workload classes as templates for custom tracker and workload modules created by the administrator.

The generic engine does not have any specific parameters associated with its type. It only has parameters common to all of the engine types.

If the generic engine is configured with at least one generic tracker in its role, then `cm-scale` loads the handler module and uses two functions that are implemented in the class. The class name can be chosen arbitrarily, but should contain the string “`Tracker`”, without the quotes. The two class functions used are:

1. `__init__`: initializes the tracker object. This can be omitted if there are no additional data values to initialize.

2. `get_workloads`: returns a list of objects belonging to a new class inherited from the `Workload` class. This new class should be created by the administrator.

The new workload class must provide the following functions and properties. The class name can be chosen arbitrarily:

1. `__init__`: initializes the workload object.

2. `to_string`: returns a string that identifies the workload. This is printed to the log file.

3. `begin_timestamp`: property that returns a unix timestamp that should be >0 if the workload is not allowed to start before that time. If it is 0 then it is ignored by `cm-scale`.

For example, the following very simple tracker and workload classes can be implemented:

**Example**

```bash
class ExampleTracker(Tracker):
    def get_workloads(self):
        return [ExampleWorkload(self)]
```

```bash
class ExampleWorkload(Workload):
    def __init__(self):
        Workload.__init__(self, tracker)
        self.set_id("1")
        self._update_state()
        self._update_age()
        self._update_resources()

    def to_string(self):
        return "workload %s" % self._id

    def _update_state():
        self._set_pending()

    def _update_age(self):
        self._age = 0

    def _update_resources(self):
        node_res = NodeResource("*")

        cpus_res = CpusResource(1)
        node_res.add_resource(cpu_res)

        engine_res = EngineResource("myengine")
        node_res.add_resource(engine_res)

        self.add_resource(node_res)

```

The classes should be located in different files, as Python module files. It is recommended, but not required, to keep both the files in the same directory. The `ExampleWorkload` class initializes the workload object with a state, age, and required resources. These values are described next.

**State:** The state can be `pending`, `running` or `failed`, which can be set with these appropriate functions:

* `self._set_pending()`

* `self._set_running()`

* `self._set_failed()`

If the state is `running`, then the workload is treated as one that occupies the nodes defined in the resources list. Each NodeResource object in the resources thus represents one occupied node.

If the state is `pending`, then the workload is treated as one that waits for free nodes. In this case `cm-scale` tries to find (start or clone) some more nodes in order to allow the workload engine to start this workload.

The `failed` workload state is considered by `cm-scale` as exceptional. Such a workload is logged in the log file, but is not considered when `cm-scale` decides what nodes to start or clone. Any other workload state is also ignored by `cm-scale`.

**Age:** The `age` defines how many seconds the workload is waiting for its resources since being added to the engine. Usually the engine can provide such information, so in the example `age` is set to `0`, which means the workload has been added to the workload engine just now. The `age` is used in the fairsharing workload priority calculation ([here](#824-fairsharing-priority-calculation-and-node-management)). The value of `age` is not re-calculated by `cm-scale` after a while. This means that the number that the module sets in the class is used during the iteration, and then forgotten by `cm-scale` until the workload object is recreated from scratch on the next iteration.

**Resources:** The Workload class (a base class) includes the `resources` property with list types. This list includes resource objects that are used by `cm-scale` in order to find appropriate nodes for the workload. The top level resource type is always NodeResource. There can be one or several node resources requested by the workload.

If the node names are known, then one NodeResource object is created per compute node.

Otherwise a single NodeResource object is used as many times as the number of requested nodes, with the name set to `*`, which is treated by `cm-scale` as any suitable node. The number of nodes can be set in the NodeResource object with the `set_amount(number)` function of the resource.

In the preceding example one (any) node resource is added to the workload request, and the requirement for CPU (cores) number is set to 1. The engine resource is used in order to restrict the running of workloads from different engines to one node. Thus if a node has this resource assigned, then the node can take on the workload. If no engine resource is assigned to the node, then it can also take on the workload, but the engine resource of the workload is assigned to the node before other workloads are considered.

The resource types that can be added to the workload are defined in the Python module `core/resource.py`:

* `NodeResource`: top level resource, contains all other resources.

* `CpusResource`: defines the number of cpu cores required or already used by the workload.

* `CategoryResource`: node category required by the workload.

* `OverlayResource`: required configuration overlay.

* `QueueResource`: HPC queue that the workload (job) belongs to. Used only with engines that support queues.

* `EngineResource`: engine name that the workload belongs to.

* `FeatureResource`: required node feature (node property, in other terminology) that should be supported by the engine.

Custom resource types are not supported for now.

In order to drain a node in the custom engine before the node is stopped, and to undrain it before the node is started, the administrator can write and configure three scripts:

* `Drain script`: called before a node is drained by Auto Scaler.

* `Undrain script`: called before node is undrained by Auto Scaler.

* `Drain status script`: called when Auto Scaler retrieves information about the current node drain status.

Either all of the three scripts must be configured, or none of them.

It is useful to drain and undrain the nodes in order to ensure that the engine does not start new jobs in time period between the instant that Auto Scaler decides to stop the node, and the instant that the actual power operation is performed.

The scripts are configured in the file:

```bash
/cm/local/apps/cm-scale/lib/python3.12/site-packages/cmscale/config.py
```

with the `GENERIC_DRAIN_COMMANDS` parameter appended to the `opts` dictionary:

**Example**

```bash
  "GENERIC_DRAIN_COMMANDS": {
    "MyEngine":
      {"drain": "/cm/local/apps/cm-scale//examples/custom_drain/drain.py",
       "undrain": "/cm/local/apps/cm-scale/examples/custom_drain/undrain.py",
       "status": "/cm/local/apps/cm-scale/examples/custom_drain/drainstatus.py"}
  },
```

Here, for each generic engine, a new dictionary is created that includes three items that correspond to, and specify, the script paths. In the preceding example `MyEngine` is the engine name, and should be the same as that defined in the `ScaleServer` role. If more then one generic engine is used then all of them can be added to `GENERIC_DRAIN_COMMANDS`.

It should be noted that if `GENERIC_DRAIN_COMMANDS` is defined in `config.py`, then CMDaemon does not drain, or undrain, via `cm-scale`.

All three scripts accept the same set of parameters, following the form:

\<*script name*>` <`*engine name*> \<*host name*>` [`*host name* `... ]`

**Example**

```bash
drain.py MyEngine node001 node002 node003
```

Each of those three scripts print the following information to standard output:

* `stdout`: JSON structure that represents a map: hostname -> latest (new) drain status. For example:

  **Example**

  ```bash
          {"node001": 2, "node002": 2, "node003": 2}
  ```

  Here the numbers are enum values defined in pythoncm in the DrainResult class.

* `stderr`: debug logs that are appended to `cm-scale.log`.

#### 8.2.6.3  Enabling Node Shutdown

By default, `cm-scale` powers off nodes belonging to a resource pool once there is no more workload for them. Resource providers can also enable shutdown, to allow the node to terminate gracefully. Shutdown has two options that set its behavior directly:

* `Shutdown Enable`: If set to `yes`, then the shutdown command is run to terminate the system services first, and after that a command is run to power off the system. A waiting time of `Shutdown Timeout` seconds takes place between the two commands.

* `Shutdown Timeout`: The number of seconds to wait before powering off a node that is in a shutdown state.

It may take more than `Shutdown Timeout` seconds for a node to power off, depending on the `Run Interval` setting. For example, if `Shutdown Timeout` is 60, and `Run Interval` 50, then effectively the `Shutdown Timeout` is 100, because the power off event only happens during an iteration execution of `cm-scale`.

#### 8.2.6.4  Multi-partition Slurm jobs

Slurm allows a user to submit a job that requests multiple queues. Auto Scaler detects such jobs and tries to start nodes for the job. The queue with the maximum priority is first considered. If no nodes are found in that partition, then the next requested partition in order of priority, is considered.

The queue priority is taken from Slurm partition `PriorityTier` parameter, accessible via `cmsh` or Base View.

* In `cmsh`, the queue priorities can be seen from within `jobqueue` mode. In the following example there are 3 queues with different priorities:

  **Example**

  ```bash
  [root@basecm10 ~]# cmsh
  [basecm10]% wlm jobqueue; list
  Name (key)   Nodes
  ------------ ------------------------
  defq         node001..node005
  medq         node006..node009
  topq         node010..node012
  [basecm10->wlm[slurm]->jobqueue]% get defq prioritytier; get medq prioritytier; get topq prioritytier
  1
  5
  10
  [basecm10->wlm[slurm]->jobqueue]% use defq; help set | grep tier
     prioritytier ........ Jobs submitted to a partition with a higher priority tier value will be
                       dispatched before pending jobs in partition with lower priority tier value
  ```

* In Base View the navigation path for the queue `defq` is:\
  `HPC` > `Workload Management Clusters` > `slurm` > `Job Queues` > `defq` > `Priority Tier`

If multiple queue trackers are configured, and if queues are requested by the Slurm job that are tracked by different trackers, then only one tracker sees the job—the tracker for which tracking queue priority is the highest.

If two queues have the same priority, then the next selection criterion is the order of placement of its trackers (section [8.2.6](#826-trackers)) in the trackers list.

For example, if the Auto Scaler (as defined by the `scaleserver` role) is running on the head node `basecm10`, and if the trackers are, for example, `mytracker` and `secondtracker`, and if the engine is, for example, `myengine`, then the order of placement can be listed in `cmsh` via the path indicated by:

**Example**

```bash
[basecm10->device[basecm10]->roles[scaleserver]->engines[myengine]->trackers]% list
Name (key)       Enabled
---------------- -------
mytracker        yes
secondtracker    yes
```

## 8.3  Examples Of `cm-scale` Use

### 8.3.1  Simple Static Node Provider Usage Example

The example session that follows explains how a static node provider ([here](#8221-static-node-provider)) can be configured and used with `cm-scale`. The session considers a default cluster with a head node and 5 regular nodes which have been previously defined in the BCM configuration. 3 of the regular nodes are powered down at the start of the run. The power control for the nodes must be functioning properly, or otherwise `cm-scale` cannot power nodes on and off.

The head node has the Slurm server role by default, and the regular nodes run with the Slurm client role by default. So, on a freshly-installed cluster, the `roleoverview` command should show something like:

**Example**

```bash
[basecm10->device[basecm10]]% roleoverview | head -2; roleoverview | grep slurm
Role             Nodes                     Categories Configuration Overlays            Nodes up
---------------- ------------------------- ---------- --------------------------------- --------
slurmaccounting  basecm10                             slurm-accounting                  1 of 1
slurmclient      node001..node005          default    slurm-client                      2 of 5
slurmserver      basecm10                             slurm-server                      1 of 1
slurmsubmit      basecm10,node001..node005 default    slurm-submit, wlm-headnode-submit 3 of 6
```

A test user, `fred` can be created by the administrator (section [6.2](/admin/usermanagement#62-managing-users-and-groups-with-cmsh)), and an MPI `hello` executable based on the `hello.c` code ([from section 3.5.1.6 of the *User Manual*](/user/mpi#3516-creating-a-simple-parallel-processing-executable)) can be built:

**Example**

```bash
[fred@basecm10 ~]$ module add shared openmpi/gcc/64 slurm
[fred@basecm10 ~]$ mpicc hello.c -o hello
```

A batch file `slurmhello.sh` ([from section 5.3.1 of the *User Manual*](/user/slurm#531-slurm-job-script-structure)) can be set up. Restricting it to 1 process per node so that it spreads over nodes easier for the purposes of the test can be done with the settings:

**Example**

```bash
[fred@basecm10 ~]$ cat slurmhello.sh
#!/bin/sh
#SBATCH -o my.stdout
#SBATCH --time=30 #time limit to batch job
#SBATCH --ntasks=1
#SBATCH --ntasks-per-node=1
module add shared openmpi/gcc/64/ slurm

mpirun /home/fred/hello
```

The user `fred` can now flood the default queue, `defq`, with the batch file:

**Example**

```bash
[fred@basecm10 ~]$ while (true); do sbatch slurmhello.sh; done
```

After putting enough jobs into the queue (a few thousand should be enough, and keeping it less than 5000 would be sensible) the flooding can be stopped with a ctrl-c.

The activity in the queue can be watched:

**Example**

```bash
[root@basecm10 ~]# watch "squeue | head -3 ; squeue | tail -3"

Every 2.0s: squeue | head -3 ; squeue | tail -3               Thu Sep 15 10:33:17 2016

             JOBID PARTITION     NAME     USER ST       TIME  NODES NODELIST(REASON)
              6423      defq slurmhel     fred CF       0:00      1 node001
              6424      defq slurmhel     fred CF       0:00      1 node002
              6572      defq slurmhel     fred PD       0:00      1 (Priority)
              6422      defq slurmhel     fred  R       0:00      1 node001
              6423      defq slurmhel     fred  R       0:00      1 node002
```

The preceding indicates that `node001` and `node002` are being kept busy running the batch jobs, while the remaining nodes are not in use. The `ST` column is a status column, and indicates whether the job is CF (configuring), PD (pending), or R (running).

Abusing `squeue` in a loop like this is regarded as a bad practice, and doing it should be minimized.

The administrator can check on the job status via the job metrics of `cmsh` too, using the options to the `filter` command, such as `--pending` or `--running`:

**Example**

```bash
[root@basecm10 ~]# cmsh -c "wlm use slurm; jobs; watch filter --running -u fred"
Every 2.0s: filter --running -u fred                          Wed May  7 12:50:05 2017
Job ID Job name      User Queue Submit time Start time End time Nodes           Exit code
------ ------------- ---- ----- ----------- ---------- -------- --------------- ---------
406    slurmhello.sh fred defq  16:16:56    16:27:21   N/A      node001,node002  0

```

and eventually, when jobs are no longer running, it should show something like:

```bash
[root@basecm10 ~]# cmsh -c "wlm use slurm; jobs; watch filter --running -u fred"
Every 2.0s: filter --running                                   Wed May  7 12:56:53 2017
No jobs found
```

So far, the cluster is queuing or running jobs without `cm-scale` being used.

The next steps are to modify the behavior by bringing in `cm-scale`. The administrator assigns the `ScaleServer` role to the head node. Within the role a new static node provider, Slurm engine, and queue tracker for the `defq` are set as follows:

**Example**

```bash
[root@basecm10 ~]# cmsh
[basecm10]% device roles master
[basecm10->device[basecm10]->roles]% use scaleserver
[basecm10->device[basecm10]->roles[scaleserver]]% resourceproviders
...->roles[scaleserver]->resourceproviders]% add static pool1
...*]->roles*[scaleserver*]->resourceproviders*[pool1*]]% set nodes node001..node005
...*]->roles*[scaleserver*]->resourceproviders*[pool1*]]% commit
...]->roles[scaleserver]->resourceproviders[pool1]]% ..;..
...]->roles[scaleserver]]% engines
...]->roles[scaleserver]->engines]% add hpc slurm1
...*]->roles*[scaleserver*]->engines*[slurm1*]]% set wlmcluster slurm
...*]->roles*[scaleserver*]->engines*[slurm1*]]% trackers
...*]->roles*[scaleserver*]->engines*[slurm1*]->trackers]% add queue tr1
...*]->roles*[scaleserver*]->engines*[slurm1*]->trackers*[tr1*]]% set queue defq
...*]->roles*[scaleserver*]->engines*[slurm1*]->trackers*[tr1*]]% commit
...->roles[scaleserver]->engines[slurm1]->trackers[tr1]]%
```

The nodes `node001..node005` should already be in the queue `defq`, as assigned to them by default when they were assigned the `SlurmClient` role. With these settings, they can now be powered up or down on demand by `cm-scale` service, depending on the number of jobs that are pending. When the new `ScaleServer` role is committed in `cmsh` or Base View, then the `cm-scale` service is started. If needed, the administrator can check the log file `/var/log/cm-scale` to see what the service is doing.

On each iteration `cm-scale` checks whether the node states should be changed. Thus after a while, the nodes `node003..node005` are started. Once up, they can start to process the jobs in the queue too.

Watching the running jobs should show the newly-started nodes running too:

**Example**

```bash
[root@basecm10 ~]# cmsh -c "wlm use slurm; jobs ; watch filter --running"
Every 2.0s: filter --running                                Thu Apr 25 16:21:59 2024
Job ID Job name      User Queue Submit time Start time End time Nodes    Exit code
------ ------------- ---- ----- ----------- ---------- -------- -------- ----------
6147   slurmhello.sh fred defq  16:16:37    16:20:17   N/A      node004  0
6148   slurmhello.sh fred defq  16:16:37    16:20:17   N/A      node001  0
6149   slurmhello.sh fred defq  16:16:37    16:20:17   N/A      node003  0
```

Eventually, `cm-scale` finds that all jobs have been dealt with, and the nodes are then powered down.

#### 8.3.1.1  High-availability And Using A Configuration Overlay For The ScaleServer Role

For high-availability clusters, where there are two head nodes, the scaleserver should run on the active head node. One labor-intensive way to set this up is to assign the service to both the head nodes, and match the scaleserver settings on both head nodes. A simpler way is to define a configuration overlay for the head nodes for the scaleserver. If the head nodes are `basecm10-1` and `basecm10-2`, then a configuration overlay called `basecm10heads` can be created and assigned the service as follows:

**Example**

```bash
    [basecm10-1]% configurationoverlay add basecm10heads
    [basecm10-1->configurationoverlay*[basecm10heads*]]% append nodes basecm10-1 basecm10-2
[basecm10-1->configurationoverlay*[basecm10heads*]]% roles
[basecm10-1->configurationoverlay*[basecm10heads*]->roles]% assign scaleserver
[basecm10-1->configurationoverlay*[basecm10heads*]->roles*[scaleserver*]]%
```

The scaleserver can then be configured within the configuration overlay instead of on a single head as was done previously in the example [here](#831-simple-static-node-provider-usage-example). After carrying out a `commit`, the `scaleserver` settings modifications are then mirrored automatically between the two head nodes.

Outside the `scaleserver` settings, one extra modification is to set the `cm-scale` service to run on a head node if the head node is active. This can be done with:

**Example**

```bash
[basecm10-1->configurationoverlay[basecm10heads]->roles[scaleserver]]% device services basecm10-1
[basecm10-1->device[basecm10-1]->services]% use cm-scale
[basecm10-1->device[basecm10-1]->services[cm-scale]]% set runif active
[basecm10-1->device*[basecm10-1*]->services*[cm-scale*]]% commit
[basecm10-1->device[basecm10-1]->services]% device use basecm10-2
[basecm10-1->device[basecm10-2]->services]% use cm-scale
[basecm10-1->device[basecm10-2]->services[cm-scale]]% set runif active
[basecm10-1->device*[basecm10-2*]->services*[cm-scale*]]% commit
```

The result is a scaleserver that runs when the head node is active.

### 8.3.2  Simple Dynamic Node Provider Usage Example

The following example session explains how a dynamic node provider ([here](#8222-dynamic-node-provider)) can be configured and used with `cm-scale`. The session considers a default cluster with a head node and 2 regular nodes which have been previously defined in the BCM configuration, and also 1 cloud director node and 2 cloud compute nodes. The cloud nodes can be configured using `cm-cluster-extension`. Only the head node is running at the start of the session, while the regular nodes and cloud nodes are all powered down at the start of the run.

At the start, the device status shows something like:

**Example**

```bash
[basecm10->device]% ds
eu-west-1-cnode001 ....... [  DOWN  ] (Unassigned)
eu-west-1-cnode002 ....... [  DOWN  ] (Unassigned)
eu-west-1-cnode003 ....... [  DOWN  ] (Unassigned)
eu-west-1-director ....... [  DOWN  ]
node001 .................. [  DOWN  ]
node002 .................. [  DOWN  ]
basecm10 ................. [   UP   ]
```

The power control for the regular nodes must be functioning properly, or otherwise `cm-scale` cannot power them on and off.

If the head node has the `slurmserver` role, and the regular nodes have the `slurmclient` role, then the `roleoverview` command should show something like:

**Example**

```bash
[basecm10->device[basecm10]]% roleoverview
Role              Nodes                                  Categories                    Nodes up
----------------- -------------------------------------- ----------------------------  --------
boot              basecm10                                                             1 of 1
cgroupsupervisor  eu-west-1-cnode001..eu-west-1-cnode002 aws-cloud-director,default    1 of 6
                  ,eu-west-1-director,node001..node002   ,eu-west-1-cloud-node
                  ,basecm10
clouddirector     eu-west-1-director                                                   0 of 1
cloudgateway      basecm10                                                             1 of 1
login             basecm10                                                             1 of 1
master            basecm10                                                             1 of 1
monitoring        basecm10                                                             1 of 1
provisioning      eu-west-1-director,basecm10                                          1 of 2
slurmclient       eu-west-1-cnode001..eu-west-1-cnode002 default,eu-west-1-cloud-node  0 of 3
                  ,node001..node002
slurmserver       basecm10                                                             1 of 1
storage           eu-west-1-director,basecm10            aws-cloud-director            1 of 2
```

A test user, `fred` can be created by the administrator (section [6.2](/admin/usermanagement#62-managing-users-and-groups-with-cmsh)), and an MPI `hello` executable based on the `hello.c` code ([from section 3.5.1.6 of the *User Manual*](/user/mpi#3516-creating-a-simple-parallel-processing-executable)) can be built:

**Example**

```bash
[fred@basecm10 ~]$ module add shared openmpi/gcc/64 slurm
[fred@basecm10 ~]$ mpicc hello.c -o hello
```

A batch file `slurmhello.sh` ([from section 5.3.1 of the *User Manual*](/user/slurm#531-slurm-job-script-structure)) can be set up. Restricting it to 1 process per node so that it spreads over nodes easier for the purposes of the test can be done with the settings:

**Example**

```bash
[fred@basecm10 ~]$ cat slurmhello.sh
#!/bin/sh
#SBATCH -o my.stdout
#SBATCH --time=30 #time limit to batch job
#SBATCH --ntasks=1
#SBATCH --ntasks-per-node=1
module add shared openmpi/gcc/64 slurm

mpirun /home/fred/hello
```

A default cluster can queue or run jobs without `cm-scale` being used. The default behavior is modified in the next steps, which bring in the `cm-scale` service:

The administrator assigns the `ScaleServer` role to the head node.

**Example**

```bash
[root@basecm10 ~]# cmsh
[basecm10]% device roles master
[basecm10->device[basecm10]->roles]% assign scaleserver
```

Within the assigned `scaleserver` role, a new dynamic node provider can be set, and properties for the dynamic pool of nodes can be set for the cloud compute nodes. Here the properties that are set are `priority` ([here](#8221-static-node-provider)), `templatenode` ([here](#8222-dynamic-node-provider)), `noderange` ([here](#8222-dynamic-node-provider)), and `extranodes` ([here](#8223-extra-nodes-settings-for-node-providers)).

**Example**

```bash
[basecm10->device*[basecm10*]->roles*[scaleserver*]]% resourceproviders
...->roles[scaleserver]->resourceproviders]% add dynamic pool2
...resourceproviders*[pool2*]]% set priority 2
...resourceproviders*[pool2*]]% set noderange eu-west-1-cnode001..eu-west-1-cnode002
...resourceproviders*[pool2*]]% set templatenode eu-west-1-cnode001
...resourceproviders*[pool2*]]% set extranodes eu-west-1-director
...resourceproviders*[pool2*]]% commit
...resourceproviders[pool2]]%
```

The regular compute nodes, `node001..node002` should be specified as nodes in the static pool.

The administrator may notice the similarity of dynamic and static pool configuration. The BCM front end has deliberately been set up to present dynamic pool and static pool nodes to the cluster administrator as two different configuration methods. This is because separating the pool types as dynamic and static pools is simpler for the cluster administrator to deal with. This way, regular compute nodes are treated, not as a special case of a dynamic pool, but simply as static pool nodes. The fundamental reason behind this separate treatment is because physical nodes cannot “materialize” dynamically with properties in the way the cloud compute nodes–which are virtualized nodes—can, due to the need to associate a MAC address with a physical node.

Assigning regular compute nodes to a static pool can be done in a similar way to what was shown before in the example [here](#831-simple-static-node-provider-usage-example).

Continuing with the current session, the nodes `node001..node002` are added to the static pool of nodes, `on-premises-nodes`. For this example they are set to a lower priority than the cloud nodes:

**Example**

```bash
...->roles[scaleserver]->resourceproviders]% add static on-premises-nodes
...->roles*[scaleserver*]->resourceproviders*[on-premises-nodes*]]% set nodes node001..node002
...->roles*[scaleserver*]->resourceproviders*[on-premises-nodes*]]% set priority 1
...->roles*[scaleserver*]->resourceproviders*[on-premises-nodes*]]% commit
...->roles[scaleserver]->resourceproviders[on-premises-nodes]]%
```

What this lower priority means is that a node that is not up and is in the static pool of nodes, is only powered on after all the cloud nodes are powered on and busy running jobs. If there happen to be nodes from the static pool that are already up, but are not running jobs, then these nodes take a job, despite the lower priority of the static pool, and irrespective of whether the dynamic pool nodes are in use.

Job priorities can be overridden in `cm-scale` by:

* allowing locations by setting `Mix Locations` to `true` ([here](#843-locations)) or

* pinning queues by setting `Pin Queues` to `true` ([here](#845-uptake-of-hpc-jobs-by-particular-types-of-nodes))

A Slurm engine, and queue tracker for the `defq` are set as follows:

**Example**

```bash
...]->roles[scaleserver]]% engines
...]->roles[scaleserver]->engines]% add hpc slurm2
...*]->roles*[scaleserver*]->engines*[slurm2]]% set wlmcluster slurm
...*]->roles*[scaleserver*]->engines*[slurm2]]% trackers
...*]->roles*[scaleserver*]->engines*[slurm2]->trackers]% add queue tr2
...*]->roles*[scaleserver*]->engines*[slurm2]->trackers*[tr2*]]% set queue defq
...*]->roles*[scaleserver*]->engines*[slurm2*]->trackers*[tr2*]]% commit
...->roles[scaleserver]->engines[slurm2]->trackers[tr2]]%
```

The nodes `node001..node002` and `eu-west-1-cnode001..eu-west-1-cnode002` should already be in the queue `defq` by default, ready to run the jobs:

**Example**

```bash
...->roles[scaleserver]->engines[slurm2]->trackers[tr2]]% wlm use slurm; jobqueue; get defq nodes
eu-west-1-cnode001
eu-west-1-cnode002
node001
node002
```

The `roleoverview` ([here](#832-simple-dynamic-node-provider-usage-example)) command is also handy for an overview, and to confirm that the role assignment of these nodes are all set to the `SlurmClient` role:

With these settings, the nodes in the dynamic pool can now be powered up or down on demand by `cm-scale` service, depending on the number of jobs that are pending. When the new `ScaleServer` role is committed in `cmsh` or Base View, then the `cm-scale` is run periodically. Each time it is run, `cm-scale` checks whether the node states should be changed. If needed, the administrator can check the log file `/var/log/cm-scale` to see what the service is doing.

Job submission can now be carried out, and the scaleserver assignment carried out earlier scales the cluster to cope with jobs according to the configuration that has been carried out in the session.

Before submitting the batch jobs, the administrator or user can check the jobs that are queued and running with the `squeue` command. If there are no jobs yet submitted, the output is simply the `squeue` headers, with no job IDs listed:

**Example**

```bash
[fred@basecm10 ~]$ squeue
JOBID PARTITION     NAME     USER ST       TIME  NODES NODELIST(REASON)
```

As in the previous example for the static pool only case ([here](#831-simple-static-node-provider-usage-example)), a way for user `fred` to flood the default queue `defq` is to run the batch file in a loop:

**Example**

```bash
[fred@basecm10 ~]$ while (true); do sbatch slurmhello.sh; done
Submitted batch job 1
Submitted batch job 2
Submitted batch job 3
...
```

After putting enough jobs into the queue (a few thousand should be enough, not more than five thousand would be sensible), the flooding can be stopped with a ctrl-c.

The changes in the queue can be watched by user `fred`:

**Example**

```bash
[fred@basecm10 ~]$ watch "squeue | head -5 ; squeue | tail -4"
Every 2.0s: squeue | head -5 ; squeue | tail -4              Wed Nov 22 16:08:52 2017

JOBID PARTITION     NAME     USER ST       TIME  NODES NODELIST(REASON)
    1      defq slurmhel     fred PD       0:00      1 (Resources)
    2      defq slurmhel     fred PD       0:00      1 (Resources)
    3      defq slurmhel     fred PD       0:00      1 (Resources)
    4      defq slurmhel     fred PD       0:00      1 (Resources)
 3556      defq slurmhel     fred PD       0:00      1 (Resources)
 3557      defq slurmhel     fred PD       0:00      1 (Resources)
 3558      defq slurmhel     fred PD       0:00      1 (Resources)
 3559      defq slurmhel     fred PD       0:00      1 (Resources)
```

The `head -4` and `tail -4` filters here are convenient for showing just the first 4 rows and last 4 rows of the very long `squeue` output, and skipping the bulk of the queue.

The preceding output illustrates how, with the jobs queued up, nothing is being processed yet from jobs number 1 to 3559 due to the resources not yet being available.

At this point `cm-scale` should have noticed that jobs are queued and that resources are needed to handle the jobs.

It should be noted that, at the time of writing of this section (January 2023), Slurm job processing with Auto Scaler currently only works as expected if `sbatch` rather than `srun` is used for dynamic jobs. The reason behind this `srun` quirk is explained [here](/admin/workloadmanagementquickref#auto-scaler-dynamic-node-issues-with-srun).

At the start of this example session the cloud director is not up. So, `cm-scale` powers it up. This can be seen by running the `ds` command, or from CMDaemon info messages:

```bash
[basecm10->device]% ds | grep director
eu-west-1-director [  DOWN  ]
then some time later:
eu-west-1-director [ PENDING ] (External ip assigned: 34.249.166.63, setting up tunnel)
then some time later:
eu-west-1-director [     INSTALLING      ] (node installer started)
then some time later:
eu-west-1-director [ INSTALLER_CALLINGINIT ] (switching to local root)
then some time later:
eu-west-1-director [   UP   ]
```

If the cloud director is yet to be provisioned to the cloud from the head node for the very first time (“from scratch”), then that can take a while. Then, because the cloud compute nodes are in turn provisioned from the cloud director, it takes a while for the cloud compute nodes to be ready to run the jobs. So, the jobs just have to wait around in the queue until the cloud compute nodes are ready, before they are handled. Fortunately, the startup of a cloud director is by default much faster after the very first time.

A quick aside about how provisioning is speeded up the next time around: The cloud compute nodes will be stopped if they are idle, and after there are no more jobs in the queue, because the jobs have all been dealt with. Then, when the `extranodeidletime` setting has been exceeded, the cloud director is also stopped. The next time that jobs are queued up, all the cloud nodes are provisioned from a stopped state, rather than from scratch, and so they are ready for job execution much faster. Therefore, unlike the first time, the jobs queued up the next time are processed with less waiting around.

Getting back to how things proceed in the example session after the cloud director is up: `cm-scale` then provisions the cloud compute nodes `eu-west-1-node001` and `eu-west-1-node002` from the cloud director.

**Example**

```bash
[basecm10->device]% ds | grep cnode
eu-west-1-cnode001 ....... [ PENDING ] (Waiting for instance to start)
eu-west-1-cnode002 ....... [ PENDING ] (Waiting for instance to start)
then some time later:
eu-west-1-cnode002 [     INSTALLING      ] (node installer started)
eu-west-1-cnode001 [     INSTALLING      ] (node installer started)
and so on
```

Once these cloud compute nodes reach the state of `UP`, they can start to process the jobs in the queue. The queue activity then would show something like:

**Example**

```bash
when the dynamic pool nodes are being readied for job execution:
[fred@basecm10 ~]$ squeue | head -5 ; squeue | tail -4
JOBID PARTITION     NAME     USER ST       TIME  NODES NODELIST(REASON)
    1      defq slurmhel     fred PD       0:00      1 (Resources)
    2      defq slurmhel     fred PD       0:00      1 (Resources)
    3      defq slurmhel     fred PD       0:00      1 (Resources)
    4      defq slurmhel     fred PD       0:00      1 (Resources)
 3556      defq slurmhel     fred PD       0:00      1 (Resources)
 3557      defq slurmhel     fred PD       0:00      1 (Resources)
 3558      defq slurmhel     fred PD       0:00      1 (Resources)
 3559      defq slurmhel     fred PD       0:00      1 (Resources)

then later:

JOBID PARTITION     NAME     USER ST       TIME  NODES NODELIST(REASON)
   11      defq slurmhel     fred CF       0:00      1 eu-west-1-cnode001
   12      defq slurmhel     fred CF       0:00      1 eu-west-1-cnode002
   13      defq slurmhel     fred CF       0:00      1 (priority)
   14      defq slurmhel     fred CG       0:00      1 (priority)
 3556      defq slurmhel     fred PD       0:00      1 (Priority)
 3557      defq slurmhel     fred PD       0:00      1 (Priority)
 3558      defq slurmhel     fred PD       0:00      1 (Priority)
 3559      defq slurmhel     fred PD       0:00      1 (Priority)

then later, when cm-scale sees all of the dynamic pool is used up, the lower priority static pool gets started up:

JOBID PARTITION     NAME     USER ST       TIME  NODES NODELIST(REASON)
  165      defq slurmhel     fred CF       0:00      1 eu-west-1-cnode001
  166      defq slurmhel     fred CF       0:00      1 node001
  168      defq slurmhel     fred CG       0:00      1 node002
 3556      defq slurmhel     fred PD       0:00      1 (Priority)
 3557      defq slurmhel     fred PD       0:00      1 (Priority)
 3558      defq slurmhel     fred PD       0:00      1 (Priority)
 3559      defq slurmhel     fred PD       0:00      1 (Priority)
  167      defq slurmhel     fred  R       0:00      1 eu-west-1-cnode002
```

In `cmsh`, the priority can be checked with:

**Example**

```bash
[basecm10 ->device[basecm10]->roles[scaleserver]->resourceproviders]% list
Name (key)        Priority     Enabled
----------------- ------------ -------
on-premises-nodes 1            yes
pool2             2            yes
```

Also in `cmsh`, the jobs can be listed via the `jobs` submode:

**Example**

```bash
[basecm10->wlm[slurm]->jobs]% list | head -5 ; list | tail -4
Type   Job ID User  Queue Running time Status       Nodes
------ ------ ----- ----- ------------ ----------   ------------------
Slurm  334    fred  defq  1s           COMPLETED    eu-west-1-cnode001
Slurm  336    fred  defq  1s           COMPLETED    node001
Slurm  3556   fred  defq  0s           PENDING
Slurm  3557   fred  defq  0s           PENDING
Slurm  3558   fred  defq  0s           PENDING
Slurm  3559   fred  defq  0s           PENDING
Slurm  335    fred  defq  1s           RUNNING      eu-west-1-cnode002
[basecm10->wlm[slurm]->jobs]%
```

Eventually, when the queue has been fully processed, the jobs are all gone:

**Example**

```bash
[fred@basecm10 ~]$ squeue
JOBID PARTITION     NAME     USER ST       TIME  NODES NODELIST(REASON)
```

With the current configuration the cloud compute nodes in the dynamic pool `pool2` are powered up before the regular compute nodes in the static pool `on-premises-nodes`. That is because the cloud compute nodes have been set by the administrator in this example to have a higher priority. This is typically sub-optimal, and is actually configured this way just for illustrative purposes. In a real production cluster, the priority of regular nodes is typically going to be set higher than that for cloud compute nodes, because using on-premises nodes is likely to be cheaper.

The administrator can also check on the job status via the job metrics of `cmsh` too, using the options to the `filter` command, such as `--pending` or `--running`:

Initially, before the jobs are being run, something like this will show up:

**Example**

```bash
[root@basecm10 ~]# cmsh -c "wlm use slurm; jobs ; watch filter --running -u fred"
Every 2.0s: filter --running -u fred                             Wed Nov 22 16:03:18 2017
No jobs found
```

Then, eventually, when the jobs are being run, the cloud nodes, which have a higher priority, start job execution, so that the output looks like:

**Example**

```bash
Every 2.0s: filter --running -u fred                             Wed Nov 22 16:50:35 2017
Job ID Job name      User Queue Submit time Start time End time Nodes           Exit code
------ ------------- ---- ----- ----------- ---------- -------- --------------- ---------
406    slurmhello.sh fred defq  16:16:56    16:27:21   N/A     eu-west1-cnode001 0
407    slurmhello.sh fred defq  16:16:56    16:27:21   N/A     eu-west1-cnode002 0
```

and eventually the regular on-site nodes which are originally down are started up by the ScaleServer and are also listed.

## 8.4  Further `cm-scale` Configuration And Examples

### 8.4.1  Dynamic Nodes Re-purposing

Sometimes it is useful to share the same nodes among several queues, and reuse the nodes for jobs from other queues. This can be done by dynamically assigning node categories in `cm-scale`. Different settings, or a different software image, then run on the re-assigned node after re-provisioning.

The feature is enabled by setting `Assign Category` parameter in the tracker settings.

For example, the following case uses Slurm as the workload engine, and sets up two queues `chem_q` and `phys_q`. Assuming in this example that jobs that are to go to `chem_q` require chemistry software on the node, but jobs for `phys_q` require physics software on the node, and that for some reason the softwares cannot run on the node at the same time. Then, the nodes can be re-purposed dynamically. That is, the same node can be used for chemistry or physics jobs by setting up the appropriate configuration for it. In this case the same node can be used by jobs that require a different configuration, software, or even operating system. The trackers configuration may then look as follows:

**Example**

```bash
[basecm10->device[basecm10]->roles[scaleserver]->engines[slurm]->trackers[chem]]% show
Parameter                        Value
-------------------------------- ------------------------------------------------
Type                             ScaleHpcQueueTracker
Name                             chem
Queue                            chem_q
Enabled                          yes
Assign Category                  chem_cat
Primary Overlays
[basecm10->device[basecm10]->roles[scaleserver]->engines[slurm]->trackers[chem]]% use phys
[basecm10->device[basecm10]->roles[scaleserver]->engines[slurm]->trackers[phys]]% show
Parameter                        Value
-------------------------------- ------------------------------------------------
Type                             ScaleHpcQueueTracker
Name                             chem
Queue                            chem_q
Enabled                          yes
Assign Category                  phys_cat
Primary Overlays
[basecm10->device[basecm10]->roles[scaleserver]->engines[slurm]->trackers[phys]]%
```

Assuming that initially there are two nodes, `node001` and `node002`, both in category `chem_cat`. Then, when `cm-scale` finds a pending job in queue `phys_q`, it may decide to assign category `phys_cat` to either `node001`, or to `node002`. In this way the number of nodes serving queue `phys_q` increases and number of nodes serving `chem_q` decreases, in order to handle the current workload. When the job is finished, the old node category is not assigned back to the node, until a new job appears in `chem_q` and requires this node to have the old category.

### 8.4.2  Pending Reasons

This section is related only to HPC engines (workload managers). In this section, the term job is used instead of workload.

If `cm-scale` makes a decision on how many nodes should be started for a job, then it checks the status of the job first. If the job status is `pending`, then it checks the list of *pending reasons* for that job. The checks are to find pending reasons that prevent the job from starting when more free nodes become available.

A pending reason can be one of the following 3 types:

Type 1:\
allows a job to start when new free nodes become available

Type 2:\
prevents a job from starting on particular nodes only

Type 3:\
prevents a job from starting anywhere

Each pending reason has a text associated with it. The text is usually printed by the workload manager job statistics utilities. The list of pending reasons texts of types 1 and 2 can be found in the pending reasons exclude file, `/cm/local/apps/cm-scale/lib/`python3.12`/site-packages/cmscale/trackers/hpc_queue/pending_reasons/WLM.exclude`, where WLM is a name of workload manager specified in the configuration of the engine in `ScaleServer` role.

In the pending reasons exclude file, the pending reason texts are listed as one reason per line. The reasons are grouped in two sublists, with headers:

* `[IGNORE_ALWAYS]`

* `[IGNORE_NO_NODE]`

The `[IGNORE_ALWAYS]` sublist lists the type 1 pending reason texts. If a job has only this group of reasons, then `cm-scale` considers the job as ready to start, and attempts to create or boot compute nodes for it.

The `[IGNORE_NO_NODE]` sublist lists the type 2 pending reason texts. If the reason does not specify the hostname of a new free node at the end of a pending reason after the colon (“:”), then the job can start on the node. If the reason does specify the hostname of a new free node after the colon, and if the hostname is owned by one of the managed nodes—nodes that can be stopped/started/created by `cm-scale`—then the job is considered as one that is not to start, when nodes become available.

If a job has a pending reason text that is not in the pending reasons exclude file, then it is assumed to be a type 3 reason. New free nodes for such a job do not get the job started.

If there are several pending reason texts for a job, then `cm-scale` checks all the pending reasons one by one. If all reasons are from the `IGNORE_ALWAYS` or `IGNORE_NO_NODE` sublists, and if a pending reason text matched in the `IGNORE_NO_NODE` sublist does not include hostnames for the managed nodes, only then will the job be considered as one that can be started just with new nodes.

#### 8.4.2.1  Custom Pending Reasons

If the workload manager supports them, then custom pending reason texts are also supported. The administrator can add a pending reason text to one of the sections in the pending reasons exclude file.

The `cm-scale` service checks only if the pending reason text for the job starts with a text from the pending reasons file. It is therefore enough to specify just a part of the text of the reason in order to make `cm-scale` take it into account. Regular expressions are also supported. For example, the next two pending reason expressions are equivalent when used to match the pending reason text `Not enough job slot(s)`:

**Example**

* `Not enough`

* `Not enough [a-z]* slot(s)`

The workload manager statistics utility can be used to find out what custom pending reason texts there are, and to add them to the pending reasons file. To do this, some test job can be forced to have such a pending reason, and the output of the job statistics utility can then be copy-pasted. For example, LSF shows custom pending reasons that look like this:

**Example**

```bash
  Customized pending reason number <integer>
```

Here, \<*`integer`*> is an identifier (an unsigned integer) for the pending reason, as defined by the administrator.

### 8.4.3  Locations

Sometimes it makes sense to restrict the workload manager to run jobs only on a defined subset of nodes. For example, if a user submits a multi-node job, then it is typically better to run all the job processes either on the on-premises nodes, or on the cloud nodes. That is, without mixing the node types used for the job. The *locations* feature of `cm-scale` allows this kind of restriction for HPC workload managers.

The `cm-scale` configuration allows one of these two modes to be selected:

1. *forced location*: when the workload is forced to use one of the locations chosen by `cm-scale`,

2. *unforced location*: when workloads are free to run on any of the compute nodes that are already managed (running, freed or started) by `cm-scale`. This is the default if Auto Scaler is set up.

In NVIDIA Base Command Manager 10, for a forced location, `cm-scale` supports these two different locations:

1. `local`: on-premises nodes,

2. `cloud`: AWS instances ([Chapter 3 of the *Cloudbursting Manual*](/cloudbursting/cexcloud)) or Azure instances ([Chapter 5 of the *Cloudbursting Manual*](/cloudbursting/cexcloudazure))

To restrict the WLM location—that is to choose a forced location—the `mixlocations` advanced setting in the `scaleserver` role for the node must be set to `no`

**Example**

```bash
[basecm10->device[basecm10]->roles[scaleserver]->advancedsettings]% set mixlocations no
[basecm10->device*[basecm10*]->roles*[scaleserver*]->advancedsettings*]% commit
```

The location is automatically configured by BCM when the node is added to the workload manager. Details per workload manager are described next.

#### 8.4.3.1  Slurm

Slurm does not allow the assignment of node properties—features, in Slurm terminology—to jobs if no node exists that is labeled by this property. Thus any property used must be added to some node. This can be the template node if a dynamic resource provider is used, or it can be an appropriate off-premises node if a static resource provider is used. If the `slurmclient` role is assigned to a node—for example, a template node—then the location value for this node is automatically configured by BCM.

The current location value can be found using the `scontrol` command. For example, for `node001`:

**Example**

```bash
[root@basecm10 ~]# module load slurm
[root@basecm10 ~]# scontrol show node node001 | grep AvailableFeatures
```

#### 8.4.3.2  PBS

A new generic resource, `resources_available.location`, lets the administrator decide the locations where `cm-scale` can run PBS jobs.

If the `pbsproclient` role is assigned to a node, then the location value for this node is automatically configured by BCM.

The current location value for a node can be found using the `qmgr` command. For example, for `node001`:

**Example**

```bash
[root@basecm10 ~]# module load openpbs
[root@basecm10 ~]# qmgr -c "print node node001" | grep location
set node node001 resources_available.location = local
```

#### 8.4.3.3  GE

A new generic resource, `location`, lets the administrator use `cm-scale` to restrict GE jobs. The resource is added automatically as a string type complex attribute. The exec host locations can be found with the `qhost` command.

If the `ugeclient` role is assigned to a node, then the location value for this node is automatically configured by BCM.

The current location value for a node can be found using the `qhost -F` command. For example, for `node001`:

**Example**

```bash
[root@basecm10 ~]# module load uge
[root@basecm10 ~]# qhost -F location -h node001
HOSTNAME                ARCH         NCPU NSOC NCOR NTHR NLOAD  MEMTOT  MEMUSE  SWAPTO  SWAPUS
----------------------------------------------------------------------------------------------
global                  -               -    -    -    -     -       -       -       -       -
node001                 lx-amd64        2    2    2    2  0.01    3.9G  543.2M     0.0     0.0
   hf:location=local
```

#### 8.4.3.4  LSF

In order to allow `cm-scale` to restrict LSF jobs, BCM configures a generic resource called `location` per node. The resource is added as a string resource in lsf.cluster.\<*CLUSTER_NAME:*> configuration file.

The location value for this node is automatically configured by BCM.

To verify that the resource is added, the `lshosts -s` command can be run:

**Example**

```bash
[root@basecm10 ~]# lshosts -s location | head -1;            lshosts -s location | grep node001
RESOURCE                                VALUE       LOCATION
location                                local       node001.cm.cluster
```

### 8.4.4  Azure Storage Accounts Assignment

If an Azure node is cloned manually from some node or node template, then the Azure node gets the same storage account as the node it has been cloned from. This may slow the nodes down if too many nodes use the same storage account. The `cm-scale` utility can therefore assign different storage accounts to nodes that are cloned like this.

The maximum number of nodes for such a storage account is defined by the `AZURE_DISK_ACCOUNT_NODES` parameter. This parameter has a value of 20 by default, and can be changed in the configuration file `/cm/local/apps/cm-scale/lib/python3.9/site-packages/cmscale/config.py`. The `cm-scale` utility must be restarted after the change.

The newly-cloned-by-`cm-scale` Azure node gets a randomly-generated storage account name if other storage accounts already have enough nodes associated with them. That is, if other storage accounts have `AZURE_DISK_ACCOUNT_NODES` or more nodes.

The storage account name is assigned in the node cloud settings in storage submode. For example, in `cmsh`, the assigned storage accounts can be viewed as follows:

**Example**

```bash
[root@basecm10 ~]# cmsh
[basecm10]% device use cnode001
[basecm10->device[cnode001]]% cloudsettings
[basecm10->device[cnode001]->cloudsettings]% storage
[basecm10->...[cnode001]->cloudsettings->storage]% get root-disk storageaccountname
azurepaclogzjus1
[basecm10->...[cnode001]->cloudsettings->storage]% get node-installer-disk storageaccountname
azurepaclogzjus1
[basecm10->device[cnode001]->cloudsettings->storage]% ..
[basecm10->device[cnode001]->cloudsettings]% get bootdiagnosticsstorageaccountname
azurepaclogzjus1
[basecm10->device[cnode001]->cloudsettings]%
```

If a node is terminated and removed from the BCM configuration, then the storage account remains in Azure. It has to be explicitly manually removed by the administrator.

### 8.4.5  Uptake of HPC Jobs By Particular Types Of Nodes

By default, `cm-scale` assumes that an HPC job submitted to a particular queue can take a node from outside the queue. This is because by assigning a category, or moving the node to a configuration overlay, the node will be moved to the appropriate queue eventually. From this point of view, the nodes form a single resource pool, and the nodes in the pool are re-purposed on demand.

In some scenarios there is a need for certain types of HPC jobs run only on particular types of nodes, without the nodes being re-purposed. A typical example: jobs with GPU code require cloud nodes that have access to GPU accelerators, while jobs that do not have GPU code can use the less expensive non-GPU cloud nodes. For this case then, the GPU cloud node is started when the GPU job requires a node, and otherwise a non-GPU node is started.

Job segregation is achieved in `cm-scale` as follows:

1. The `Pin Queues` setting, which is an advanced setting in the `scaleserver` role for the node, is enabled:

   ```bash
   [basecm10->device[basecm10]->roles[scaleserver]->advancedsettings]% set pinqueues yes
   [basecm10->device*[basecm10*]->roles*[scaleserver*]->advancedsettings*]% commit
   ```

2. A new queue is created, or an existing one is used. The queue is used for the jobs that require a particular node type.

3. The particular node type is added to this queue. If the node is already defined in BCM, then the administrator can assign the queue to the node in the workload manager client role. For example, if the workload manager is Slurm, then the queue is assigned to the nodes in the `slurmclient` role. If the node has not been defined yet and will be cloned on demand (according to the dynamic resource provider settings, [here](#8222-dynamic-node-provider)), then its template node is assigned to the queue. When a new node is cloned from the template, the queue is then inherited from the template node.

4. The previous two steps are repeated for each job type.

After that, if a user submits a job to one of the queues, then `cm-scale` starts or clones a node that is linked with the job queue.

The following `cmsh` session snippet shows a configuration example:

**Example**

```bash
[root@basecm10 ~]# cmsh
[basecm10]% device roles master
[basecm10->device[basecm10]->roles]% use scaleserver
[basecm10->...roles[scaleserver]]% resourceproviders
[basecm10->...roles[scaleserver]->resourceproviders]% add dynamic rp1
[basecm10->...roles[scaleserver]->resourceproviders*[rp1*]]% set templatenode tnode1
[basecm10->...roles[scaleserver]->resourceproviders*[rp1*]]% set noderange cnode001..cnode100
[basecm10->...roles[scaleserver]->resourceproviders*[rp1*]]% commit
[basecm10->...roles[scaleserver]->resourceproviders[rp1]]% clone rp2
[basecm10->...roles[scaleserver]->resourceproviders*[rp2*]]% set templatenode tnode2
[basecm10->...roles[scaleserver]->resourceproviders*[rp2*]]% set noderange cnode101..cnode200
[basecm10->...roles[scaleserver]->resourceproviders*[rp2*]]% commit
[basecm10->...roles[scaleserver]->resourceproviders[rp2]]% ..;..
[basecm10->...roles[scaleserver]]% engines
[basecm10->...roles[scaleserver]->engines]% add hpc s1
[basecm10->...roles[scaleserver]->engines*[e1*]]% set workloadmanager slurm
[basecm10->...roles[scaleserver]->engines*[e1*]]% trackers
[basecm10->...roles[scaleserver]->engines*[e1*]->trackers]]% add queue tr1
[basecm10->...roles[scaleserver]->engines*[e1*]->trackers*[tr1*]]% set queue q1
[basecm10->...roles[scaleserver]->engines*[e1*]->trackers*[tr1*]]% commit
[basecm10->...roles[scaleserver]->engines[e1]->trackers[tr1]]% clone tr2
[basecm10->...roles[scaleserver]->engines*[e1*]->trackers*[tr2*]]% set queue q2
[basecm10->...roles[scaleserver]->engines*[e1*]->trackers*[tr2*]]% commit
[basecm10->...roles[scaleserver]->engines[e1]->trackers[tr2]]% category
[basecm10->category]% clone default cat1
[basecm10->category*[cat1*]]% roles
[basecm10->category*[cat1*]->roles*]% assign slurmclient
[basecm10->category*[cat1*]->roles*[slurmclient*]]% set queues q1
[basecm10->category*[cat1*]->roles*[slurmclient*]]% commit
[basecm10->category[cat1]->roles[slurmclient]]% category clone cat1 cat2
[basecm10->category*[cat2*]->roles*[slurmclient*]]% set queues q2
[basecm10->category*[cat2*]->roles*[slurmclient*]]% commit
[basecm10->category[cat2]->roles[slurmclient]]% device use tnode1
[basecm10->device[tnode1]]% set category cat1
[basecm10->device*[tnode1*]]% commit
[basecm10->device[tnode1]]% device use tnode2
[basecm10->device[tnode2]]% set category cat2
[basecm10->device*[tnode2*]]% commit
[basecm10->device[tnode2]]%
```

Using the preceding configuration, the user may submit a job with a regular workload manager submission utility specifying the queue `q1` or `q2`, depending on whether the job requires nodes that should be cloned from `tnode1` or from `tnode2`.

### 8.4.6  How To Exclude Unused Nodes From Being Stopped

If a node is idle, then by default `cm-scale` automatically stops or terminates the node.

However, in some cases there may be a need to start a node on demand, and when it becomes idle, there may be a need to keep the node running. This can be useful if the administrator would like to investigate the performance of an application, or to debug some issues. After completing the investigation or debug session, the administrator can stop the node manually.

The parameter `KEEP_RUNNING_RANGES` keeps such nodes from being stopped or terminated. The parameter should be added to the configuration file `/cm/local/apps/cm-scale/lib/python3.9/site-packages/cmscale/config.py`. To have the changed setting take effect, the `cm-scale` service must be restarted.

`KEEP_RUNNING_RANGES` defines a map of resource provider names to node name ranges.

Extra nodes can be added to the range of the nodes. However, if the extra node must not be stopped or terminated by `cm-scale`, then for each resource provider that has such an extra node, the value of `extranodestop` must be set to `yes`.

In the following example, nodes `cnode002`, `cnode003`, `cnode004`, and `cnode010`, are associated with the `azurenodes1` resource provider. They are therefore never stopped or terminated by `cm-scale`. They are only started on demand by `cm-scale`.

The nodes `cnode012` and `cnode014` are associated with the `azurenodes2` resource provider. They are therefore also not stopped or terminated by `cm-scale`.

**Example**

```bash
opts = {
  [...]
  "KEEP_RUNNING_RANGES": {
    "azurenodes1": "cnode002..cnode004,cnode010",
    "azurenodes2": "cnode012,cnode014"
  }
}
```

### 8.4.7  Prolog And Epilog Scripts With Auto Scaler

Sometimes the administrator would like some actions to be performed for a workload when the Auto Scaler allocates and starts using a node, or when the Auto Scaler deallocates and stops using a node. The administrator can arrange such actions by configuring prolog and epilog scripts (section [7.3.4](/admin/workloadmanagement#734-prolog-and-epilog-scripts)) in the resource provider. The scripts are then executed on the nodes running the Auto Scaler service, i.e. with the `ScaleServer` role.

Both the dynamic and the static resource providers (section [8.2.2](#822-resource-providers)) support the following options:

1. `allocationProlog`: path to a shell script that is executed just before a node is started up by Auto Scaler

2. `allocationEpilog`: path to a shell script that is executed just before a node is powered off by Auto Scaler

3. `allocationScriptsTimeout`: the prolog and epilog scripts timeout (the script that is running is killed if the timeout is exceeded).

The prolog script runs when an existing node is about to start, and also runs when a node has just been cloned and is also about start.

The epilog script runs when a node is stopped or when a cloud node is terminated.

The prolog and epilog scripts are run per node, and can run in parallel. Thus if synchronization between them is needed, then it should be implemented by the scripts themselves.

The standard output and error messages of the executed scripts are mixed and added to the Auto Scaler as `debug2` log messages (the `debug2` logs can be enabled in the `AdvancedSettings` submode of the ScaleServer role). It therefore makes sense to keep the output reasonably small, informative, and human readable.

When the scripts are run, Auto Scaler passes environment variables that can be used inside the scripts in order to decide what to do. These environment variables are:

1. `AS_NODE`: node short hostname which the script started for;

2. `AS_SCRIPT_TYPE`: either "epilog" or "prolog";

3. `AS_RESOURCE_PROVIDER`: name of the resource provider where this script is configured;

4. `AS_ENGINE`: workload engine name, which workload requires the node ("unknown" if no workload requires the node).

By default the scripts are not defined, and therefore nothing is executed by default when nodes are stopped, terminated or started.

### 8.4.8  Queue Node Placeholders

A queue node placeholder is a node that does not yet exist, but has a corresponding object that exists, and the object has queues defined, amongst other properties. It can be used to plan resource use.

#### 8.4.8.1  Job Rejection For Exceeding Total Cluster Resources

At the time of job submission, the workload manager checks the total available number of slots (used and unused) in a queue. This is the sum of the available slots (used and unused) provided by each node in that queue.

* Jobs that require less than the total number of slots are normally made to wait until more slots become available.

* Jobs that require more than this total number of slots are normally rejected outright by the workload manager, without being put into a wait state. This is because workload managers normally follow a logic that relies on the assumption that if the job demands more slots than can exist on the cluster as it is configured at present, then the cluster will never have enough slots to allow a job to run.

#### 8.4.8.2  Assuming The Resources Can Never Be Provided

The latter assumption, that a cluster will never have enough slots to allow a job to run, is not true when the number of slots is dynamic, as is the case when `cm-scale` is used. When `cm-scale` starts up nodes, it adds them to a job queue, and the workload manager is automatically configured to allow users to submit jobs to the enlarged queue. That is, the newly available slots are configured as soon as possible so that waiting jobs are dealt with as soon as possible. For jobs that have already been rejected, and are not waiting, this is irrelevant, and users would have to submit the jobs once again.

Ideally, in this case, the workload manager should be configured to know about the number of nodes and slots that can be started up in the future, even if they do not exist yet. Based on that, jobs that would normally be rejected, could then also get told to wait until the resources are available, if it turns out that configured future resources will be enough to run the job.

#### 8.4.8.3  Slurm Resources Planning With Placeholders

Slurm allows nodes that do not exist yet to be defined. These are nodes with hostnames that do not resolve, and have the Slurm setting of `state=CLOUD` for cloud nodes, and `state=FUTURE` for other nodes. BCM allows Slurm to add such “fake” nodes to Slurm queues dynamically, when not enough real nodes have yet been added. BCM supports this feature only for Slurm at present.

This feature is not yet implemented for the other workload managers because they require the hostname of nodes that have been added to the workload manager configuration to be resolved.

Within the Slurm WLM instance it is possible to set a list of placeholder objects. In `cmsh` this can be done within the main `wlm` mode, selecting the Slurm instance, and then going into the `placeholders` submode. Each placeholder allows the following values to be set:

* `queue`: the queue name, used as key

* `maxnodes`: the maximum number of nodes that this queue allows

* `basenodename`: the base node name that is used when a new node name is generated

* `templatenode`: a template node that is used to provide user properties taken from its slurmclient role when new fake nodes are added.

For example, the following `cmsh` session uses the head node with an existing `slurm` instance to illustrate how the Slurm queue `defq` could be configured so that it always has a maximum of 32 nodes, with the nodes being like node001:

**Example**

```bash
[root@basecm10 ~]# scontrol show part defq | grep " Nodes="
Nodes=node001
[root@basecm10 ~]# cmsh
[basecm10]% wlm use slurm
[basecm10->wlm[slurm]]% placeholders
[basecm10->wlm[slurm]->placeholders]% add defq
[basecm10->wlm*[slurm*]->placeholders*[defq*]]% set maxnodes 32
[basecm10->wlm*[slurm*]->placeholders*[defq*]]% set basenodename placeholder
[basecm10->wlm*[slurm*]->placeholders*[defq*]]% set templatenode node001
[basecm10->wlm*[slurm*]->placeholders*[defq*]]% commit
[basecm10->wlm[slurm]->placeholders[defq]]%
[root@basecm10 ~]# scontrol show part defq | grep " Nodes="
   Nodes=node001,placeholder[01-31]
```

If a new real node is added to the queue, then the number of placeholder nodes is decreased by one.

The placeholders can also be configured in Base View via the HPC resource, using the navigation path:

`HPC` > `Workload Management Clusters` > \<*Slurm instance*> > `JUMP TO Placeholders`

#### 8.4.8.4  Preventing `slurmctld` From Restarting

If the number of nodes is changed, or if their names are changed in `slurm.conf`, then CMDaemon restarts the Slurm server daemon, `slurmctld`, to apply the changes. If the administrator needs to prevent `slurmctld` from restarting each time that a new node is added to Slurm, then the nodes can be added, or cloned, to the BCM configuration manually, even if they do not have any IP address assigned yet. This is assuming that they get their IP addresses assigned over DHCP later on.

If the nodes are added to the configuration manually, then CMDaemon restarts `slurmctld` only once. This means that, when `cm-scale` starts the nodes, CMDaemon does not restart `slurmctld`.

### 8.4.9  Auto Scaling A Job On-premises To A Workload Manager And Kubernetes

In the session for this section, a cluster with 4 nodes is assumed. A workload manager such as Slurm is assumed to be already set as the engine (**Use Case: Workload Manager (On-premises)**, [here](#8131-use-case-workload-manager-on-premises)).

If the cluster administrator now would also like to make a Kubernetes engine available to jobs, as suggested in the use case 2 [here](#811-use-cases), then it can be added within the `scaleserver` role as follows:

**Example**

```bash
[basecm10->configurationoverlay[autoscaler]->roles[scaleserver]->engines]% list
Name (key)       Priority
---------------- ------------
slurm            0
[basecm10->configurationoverlay...->engines]% add kubernetes k8s
[basecm10->configurationoverlay*...->engines*[k8s*]]% set cluster default
[basecm10->configurationoverlay*...->engines*[k8s*]]% trackers
[basecm10->configurationoverlay*...->engines*[k8s*]->trackers]% add namespace default
[basecm10->configurationoverlay*...[k8s*]->trackers*[default*]]% set controllernamespace default
[basecm10->configurationoverlay*...->engines*[k8s*]->trackers*[default*]]% commit
[basecm10->configurationoverlay...->engines[k8s]->trackers[default]]%
```

In the trackers for each engine, the overlay to move to must be specified:

**Example**

```bash
[basecm10->configurationoverlay...->engines[k8s]->trackers[default]]% set primaryoverlays kube-default-worker
[basecm10->configurationoverlay*...->engines*[k8s*]->trackers*[default*]]% commit
[basecm10->configurationoverlay...->engines[k8s]->trackers[default]]% ..
[basecm10->configurationoverlay...->engines[k8s]->trackers]% ..
[basecm10->configurationoverlay...->engines[k8s]]% ..
[basecm10->configurationoverlay...->engines]% use slurm
[basecm10->configurationoverlay...->engines[slurm]]% trackers
[basecm10->configurationoverlay...->engines[slurm]->trackers]% use defq
[basecm10->configurationoverlay...->engines[slurm]->trackers[defq]]% set primaryoverlays slurm-client
[basecm10->configurationoverlay*...->engines*[slurm*]->trackers*[defq*]]% commit
[basecm10->configurationoverlay...->engines[slurm]->trackers[defq]]%
```

Since the cluster is entirely on-premises, and no cloud nodes are to be used, there is no need to configure a dynamic provider (section [8.3.2](#832-simple-dynamic-node-provider-usage-example)).

To allow movement of jobs from one queue to another, queue pinning must be disabled:

**Example**

```bash
[basecm10->configurationoverlay[autoscaler]->roles[scaleserver]->advancedsettings]% set pinqueues no
[basecm10->configurationoverlay*[autoscaler*]->roles*[scaleserver*]->advancedsettings*]% commit
[basecm10->configurationoverlay[autoscaler]->roles[scaleserver]->advancedsettings]%
```

Auto scaler normally takes the amount of memory into account from the workload manager. However, Slurm does not know about the memory of nodes that are not managed by it. A default memory size should therefore be set for when a job requirement is matched to Slurm, using the default resources specification ([here](#8124-default-resources-specification)):

**Example**

```bash
[basecm10->configurationoverlay...->resourceproviders[static]]% set defaultresources "mem_free:slurm=7GB"
[basecm10->configurationoverlay*[autoscaler*]->roles*[scaleserver*]->resourceproviders*[static*]]% commit
[basecm10->configurationoverlay[autoscaler]->roles[scaleserver]->resourceproviders[static]]%
```

The nodes reboot when a job requires it:

**Example**

```bash
[basecm10->configurationoverlay[autoscaler]->roles[scaleserver]->resourceproviders[static]]%
Tue Aug 16 11:43:40 2022 [notice] basecm10: node003 [       BOOTING       ] (ldlinux.c32 from basecm10)
Tue Aug 16 11:43:40 2022 [notice] basecm10: node004 [       BOOTING       ] (ldlinux.c32 from basecm10)
[basecm10->configurationoverlay[autoscaler]->roles[scaleserver]->resourceproviders[static]]%
Tue Aug 16 11:44:22 2022 [notice] basecm10: node004 [     INSTALLING      ] (node installer started)
[basecm10->configurationoverlay[autoscaler]->roles[scaleserver]->resourceproviders[static]]%
Tue Aug 16 11:44:24 2022 [notice] basecm10: node003 [     INSTALLING      ] (node installer started)
[basecm10->configurationoverlay[autoscaler]->roles[scaleserver]->resourceproviders[static]]%
```

### 8.4.10  AWS Spot Instances And Availability Zones

Amazon cloud regions consist of multiple, isolated, *availability zones*. The number of spot instances that can be started in each zone is limited by the capacity of a zone. If the spot instances are configured to start in several different availability zones, then Auto Scaler detects this and tries to start nodes in those various different availability zones. At the start of each iteration of `cm-scale`, if `cm-scale` sees that the capacity of a zone is exhausted, then all nodes in that zone are considered to be unavailable for starting up by `cm-scale`.

Configuring several sets of spot instances in availability zones allows running nodes to be started up, even if the capacity in one or more zones is exhausted. For this configuration, the cluster administrator has two options:

1. Configuring the nodes from different availability zones in one workload manager job queue or Kubernetes namespace.

2. Having the nodes in different queues/namespaces, and letting users submit the jobs to multiple queues at the same time, so that `cm-scale` goes through the queues when selecting a node to start. This option requires multi-queue support in the workload manager. In this case, the `allowedresourceproviders` parameter should not be set within the `trackers` submode (section [8.2.6](#826-trackers)) for the engine.

If cloud nodes (spot instances) from different availability zones are added to the `scaleserver` role, then the lack of capacity is recognized by `cm-scale` automatically, and no additional configuration is needed.

The cluster administrator can however still override the availability zones information for `cm-scale`. This can be carried out by modifying the `cm-scale` configuration file:\
`/cm/local/apps/cm-scale/lib/*/site-packages/cmscale/config.py`\
In the file, a new parameter `AVAILABILITY_ZONES` must be added to the opts dictionary. The format the parameter takes is as follows:

**Example**

```bash
    {"AVAILABILITY_ZONES" : {<provider name> : {<availability zone name> : <node list in node range format>}}
```

For example, for the `us-west-*` availability zones:

**Example**

```bash
    "AVAILABILITY_ZONES": {
        "aws": {
            "us-west-2a": "cpu-001..cpu-005, cpu-spot-a-001..cpu-spot-a-010",
            "us-west-2c": "cpu-spot-c-001..cpu-spot-c-010",
            "us-west-2d": "cpu-spot-d-001..cpu-spot-d-010",
        },
    },
```

Currently, availability zones are supported by Auto Scaler only for AWS. Auto Scaler ignores any lack of capacity in the availability zones of other cloud providers.