# Configuring The Cluster

After the NVIDIA Base Command Manager software has been installed on the head node, the cluster must be configured. For convenience, the regular nodes on the cluster use a default software image stored on the head node. The image is supplied to the regular nodes during a process called provisioning (Chapter [5](/admin/provisioning)), and both the head node and the regular nodes can have their software modified to suit exact requirements (Chapter [11](/admin/softwareimagemanagement)). This chapter however goes through a number of basic cluster configuration aspects that are required to get all the hardware up and running on the head and regular nodes.

Section [3.1](#31-main-cluster-configuration-settings) explains how some of the main cluster configuration settings can be changed.

Section [3.2](#32-network-settings) details how the internal and external network parameters of the cluster can be changed.

Section [3.3](#33-configuring-bridge-interfaces) describes the setting up of network bridge interfaces.

Section [3.4](#34-configuring-vlan-interfaces) describes VLAN configuration.

Section [3.5](#35-configuring-bonded-interfaces) describes the setting up of network bond interfaces.

Section [3.6](#36-configuring-infiniband-interfaces) covers how InfiniBand is set up.

Section [3.7](#37-configuring-bmc-ipmiilodraccimcredfish-interfaces) describes how Baseboard Management Controllers such as IPMI, iLO, DRAC, CIMC, and Redfish are set up.

Section [3.8](#38-configuring-bluefield-dpus) describes how BlueField DPUs are set up.

Section [3.9](#39-configuring-switches-and-pdus) describes how switches are set up.

Section [3.10](#310-configuring-cumulus-switches) describes how Cumulus switches are configured.

Section [3.11](#311-configuring-netq-network-management-system) describes how NetQ can be integrated with BCM.

Section [3.12](#312-disk-layouts-disked-semi-diskless-and-diskless-node-configuration) explains how disk layouts are configured, as well as how diskless nodes are set up.

Section [3.13](#313-configuring-nfs-volume-exports-and-mounts) describes how NFS volumes are exported from an NFS server and mounted to nodes using the integrated approach of BCM.

Section [3.14](#314-managing-and-configuring-services) describes how services can be run from BCM.

Section [3.15](#315-managing-and-configuring-a-rack) describes how a rack can be configured and managed with BCM.

Section [3.16](#316-configuring-gpu-settings) describes how GPUs can be configured with BCM.

Section [3.18](#318-configuring-custom-scripts) describes how custom scripts can replace some of the default scripts in use.

Section [3.20](#320-cluster-configuration-without-execution-by-cmdaemon) discusses configuration alternatives that are not based on CMDaemon.

Section [3.21](#321-saving-a-backup-of-configuration-files-with-versionconfigfiles) describes how the configuration files prior to a configuration change can be saved.

More elaborate aspects of cluster configuration such as power management, user management, package management, and workload management are covered in later chapters.

## 3.1  Main Cluster Configuration Settings

While both front ends—`cmsh` and Base View—can be used to carry out cluster management (Chapter [2](/admin/clustermanagement)), the BCM Manuals often describe configuration with an arbitrary front end rather than for both front ends.

This is because the front ends are usually analogous enough to each other when carrying out a configuration procedure, so that describing the procedure for the other front end in detail as well is mostly wasteful. If the procedures differ significantly, then guidance is typically given on the differences.

Thus, for example, both `cmsh` and Base View can be used for the global configuration of cluster settings. For the `cmsh` front end, the configuration is done using `partition` mode. The analog to global configuration in the Base View front end relies on the navigation path: `Cluster` > `Settings`.

This section now continues with the Base View description.

The navigation path: `Cluster` > `Settings` brings up Base View’s cluster `Settings` window (figure [3.1](#fig-bright-view-clustersettings)):

![Cluster Settings](/base-command-manager/product-manuals/_fern-img/3386ee47d2a78718e34f1bef571747e9e9b4e69d6eb4135726a27278254b379f.webp)

*Figure 3.1: Cluster Settings*

The navigational overview (figure [2.4](/admin/clustermanagement#242-navigating-the-cluster-with-base-view)) indicates how the main cluster `Settings` window fits into the organizational layout of BCM.

The cluster `Settings` window allows changes to be made to many of the global cluster settings. Its values can in some cases be overridden by more specific configuration levels, such as category-level or node-level configuration. The main cluster settings in figure [3.1](#fig-bright-view-clustersettings) are related to the cluster name-related settings, cluster networking, and some miscellaneous global cluster settings.

### 3.1.1  Cluster Configuration: Various Name-Related Settings

In the Base View `Settings` window, the following defaults can be viewed and modified for names throughout the cluster.

* `Cluster name`: (default name: `BCM 10.0 Cluster`)

* `External network`: (default name: `externalnet`)

* `Internal network`: (default name: `internalnet`)

* `Default category`: (default name: `default`)

* How the nodes of the cluster are named:

  * `Node name`: the base prefix, also called *basename* (default prefix name: `node`)

  * `Node digits size`: number of digits in suffix of node name (default size: `3`)

  The global node naming structure can be managed in Base View via the navigation path `Cluster` > `Settings` > `NODE BASENAME`. It can also be managed in `cmsh` via the parameters `nodebasename` and `nodedigits`, under the `partition` mode ([here](#internalnetworkparametersclusterobject)) of `cmsh`.

  Changing the naming and digit size only affects nodes created after the setting.

  Renaming of existing node names is possible using the `rename` command from `device` mode of `cmsh`, (section [2.5.5.13](/admin/clustermanagement#25513-renaming-nodes-with-the-rename-command), [here](/admin/clustermanagement#25513-renaming-nodes-with-the-rename-command)).

  Cloning of nodes is also possible, and can save some work for the cluster administrator, due to some heuristics used to get the cloned node configured correctly ([here](/admin/clustermanagement#2559-looping-over-objects-with-foreach)).

### 3.1.2  Cluster Configuration: Some Network-Related Settings

These following network-related settings are also described in the context of external network settings for the cluster object, in section [3.2.3](#323-changing-network-parameters), as well as in the quickstart in [Chapter 1 of the *Installation Manual*](/installation/quickstart).

#### 3.1.2.1  Nameserver And Search Domains Used By Cluster

* If Base View is used, then the settings window can be used to set the IP address of the nameserver and the names of the search domains for the cluster.

  By default, the nameserver is the internal (regular-nodes-facing) IP address of the head node. Multiple nameservers can be added. If the value is set to `0.0.0.0`, then the address supplied via DHCP to the head node is used. Alternatively, a static value can be set. Static IP addresses must be used for external addresses in the case of the cluster being configured with high availability.

* If `cmsh` is used instead of Base View, then the changes to the `nameserver` and `searchdomain` values can instead be carried out via `partition` mode ([here](#3233-changing-external-network-parameters-for-the-cluster)).

**Limit to the number of search domains:** In older versions of glibc (before 2.26), the number of names that can be set as search domains used by the cluster has a hardcoded maximum limit of 6, with a total of 256 characters.

From glibc 2.26 onward, this operating system limit no longer applies to normal lookups. BCM applies its own limit instead, using the `MaximalSearchDomains` `GlobalConfig` directive (Appendix [C](/admin/cmdconf), [here](/admin/cmdconf#c55-maximalsearchdomains-directive)), which defaults to 32 search domains, and which can be set to any value from 1 to 1024.

Raising `MaximalSearchDomains` above 6 only has an effect on a cluster running glibc 2.26 or later. On an older glibc, only the first 6 configured search domains are used, regardless of the directive’s setting.

#### 3.1.2.2  Changing The Order In `resolv.conf`

For clusters, CMDaemon by default automatically writes the `/etc/resolv.conf` by using the following sources, and in the following order:

1. Global network

2. Other networks

3. Category search domains

4. Partition search domains

Because older glibc versions only support 6 entries in `/etc/resolv.conf`, it is sometimes useful to exclude or reorder the preceding sources.

For a network object, there are two fields that control the position of the domain name in the file `/etc/resolv.conf`:

**Example**

```bash
[basecm10]% network use ibnet
[basecm10->network[ibnet]]% show
...
Exclude from search domain       no
Search domain index              0
```

If the `Exclude from search domain` field is set to `yes`, then the domain name for the network is not used.

The `Search domain index` field specifies the position of the domain name. A value of `0` means CMDaemon automatically determines its location.

The index of the category and partition search domains can also be changed by appending a number, in the suffix format `:` \<*index*>, to the domain name:

**Example**

```bash
[basecm10]% partition
[basecm10->partition[base]]% get searchdomains
example.com:1
domain.test:6
```

If an index is set for one search domain, then setting indices for all search domains is recommended. Search domains without indices are handled automatically by CMDaemon.

CMDaemon sorts all search domains according to index, and writes `/etc/resolv.conf` with the 6 that have the lowest index, with the lowest index first.

#### 3.1.2.3  Setting The Stub Resolver For Ubuntu Hosts

For Ubuntu, CMDaemon generates a `/etc/resolv.conf` file (Appendix [A](/admin/generatedfiles)), and symlinks it to the `resolv.conf` managed by `systemd` at `/etc/run/systemd/resolve/resolve.conf`.

However, a default Ubuntu without BCM uses a systemd stub resolver service (`man systemd-resolved.8`) that listens on the IP address 127.0.0.53. Sometimes a stub resolver is also useful in BCM for containers such as enroot containers (section [7.3.3](/admin/workloadmanagement#733-installation-and-configuration-of-enroot-and-pyxis-with-slurm-to-run-containerized-jobs)) that mount and use `/etc/resolv.conf`.

To enable resolution for such containers on a node via the stub resolver instead of the uplink resolver, the resolver can be set using the extra `resolve` parameter, using the `-e|--extra` setting:

**Example**

```bash
basecm10->device[node001]]% # to set it to the stub resolver:
basecm10->device[node001]]% set -e resolv stub
basecm10->device*[node001*]]% commit        # wait a bit
basecm10->device[node001]]% # to set it back to the BCM value:
basecm10->device[node001]]% set -e resolv uplink
basecm10->device*[node001*]]% commit       # wait a bit
```

#### 3.1.2.4  Externally Visible IP Address

The externally visible IP address are public (non-RFC 1918) IP addresses to the cluster. These can be set to be visible on the external network.

* If using Base View, the navigation path is:\
  `Cluster` > `Settings` > `EXTERNALLY VISIBLE IP`.

* For `cmsh`, the parameter `externallyvisibleip` can be set via `partition` mode.

#### 3.1.2.5  Time server(s)

Time server hostnames can be specified for the NTP client on the head node.

* If using Base View, the navigation path is via `Cluster` > `Settings` > `NAME SERVERS`.

* For `cmsh`, the parameter `timeservers` can be set via `partition` mode.

#### 3.1.2.6  Time Zone

The time zone setting can be set at various grouping levels:

If applied to the entire cluster, and if it is applied in `partition` mode, then:

* In Base View, the time zone parameters can be jumped to via the navigation path:\
  `Cluster` > `Settings` > `JUMP TO` > `Time zone`

* In `cmsh`, the time zone can be selected in `partition` mode, using the `base` object. Tab-completion prompting after entering “`set timezone`” displays a list of several hundred possible time zones, from which one can be chosen:

  **Example**

  ```bash
  [basecm10]% partition use base
  [basecm10->partition[base]]% set timezone america/los_angeles
  [basecm10->partition*[base*]]% commit
  ```

A time zone setting can also be applied at the level of a node, category, edge site, and cloud region. As is usual in the BCM hierarchy, the value set for the larger grouping is the default value used by the members of that group, while a value set specifically for the individual members of that group overrides such a default.

### 3.1.3  Miscellaneous Settings

#### 3.1.3.1  BMC (IPMI/iLO, DRAC, CIMC, Redfish) Settings

The BMC (Baseboard Management Controller) access settings can be configured in Base View via the navigation path:\
`Cluster` > `Settings` > `JUMP TO` > `BMC Settings`

This opens up a window so that the BMC settings can be managed:

* `User name`: (default: `bright`)

* `Password`: (default: random string generated during head node installation)

* `User ID`: (default: `4`)

* `Power reset delay`: During a reset, this is the time, in seconds, that the machine is off, before it starts powering up again (default: `0`)

* `Extra arguments`: (default: none)

* `privilege`: (default: administrator)

The defaults in the preceding are set when the BMC interfaces are configured during head node installation. If the BMC interfaces are not set then, then the defaults are also unset.

BMC configuration is discussed in more detail in section [3.7](#37-configuring-bmc-ipmiilodraccimcredfish-interfaces).

#### 3.1.3.2  Administrator E-mail Setting

By default, the distribution which BCM runs on sends e-mails for the administrator to the root e-mail address. The administrator e-mail address can be changed within BCM so that these e-mails are received elsewhere.

* In Base View, an e-mail address (or space-separated addresses) can be set in the `Administrator e-mail` field via the navigation path `Cluster` > `Settings` > `CLUSTER NAME` (figure [3.1](#fig-bright-view-clustersettings)).

* In `cmsh`, the e-mail address (or space-separated addresses) can be set in `partition` mode, using the `base` object as follows:

  **Example**

  ```bash
  [basecm10]% partition use base
  [basecm10->partition[base]]% set administratore-mail alf@example.com beth@example.com
  [basecm10->partition*[base*]]% commit
  ```

The following critical states or errors cause e-mails to be sent to the e-mail address:

* By default, a month before the cluster license expires, a reminder e-mail is sent to the administrator account by CMDaemon. A daily reminder is sent if the expiry is due within a week.

* A service on the head node that fails on its first ever boot.

* When an automatic failover fails on the head or regular node.

#### 3.1.3.3  SMTP Relay Host Mailserver Setting

The head node uses Postfix as its SMTP server. The default base distribution configuration is a minimal Postfix installation, and so has no value set for the SMTP relay host. To set its value:

* in Base View: the `Relay Host` field sets the SMTP relay host for the cluster resource

* in `cmsh`: the `relayhost` property can be set for the `base` object within `partition` mode:

  **Example**

  ```bash
  [root@basecm10 ~]# cmsh
  [basecm10]% partition use base
  [basecm10-> partition[base]]% set relayhost mail.example.com
  [basecm10-> partition[base*]]% commit
  ```

Postfix on the regular nodes is configured to use the head node as a relay host and is normally left untouched by the administrator.

If the regular node configuration for Postfix is changed in `partition` mode, then a node reboot deploys the change for the node. Setting the `AdvancedConfig` ([here](/admin/cmdconf#c80-advancedconfig-directive)) `SmtpPartitionRelayHostInImages` to `0` disables the changing of the relay host on the regular node.

Further Postfix changes can be done directly to the configuration files as is done in the standard distribution. The changes must be done after the marked auto-generated sections, and should not conflict with the auto-generated sections.

A convenient way to check mail is functioning is to run BCM’s `testemail` command. The command is run from within the `main` mode of `cmsh`. It sends a test e-mail out using CMDaemon:

```bash
[root@basecm10 ~]# mailq; ls -al /var/spool/mail/root
Mail queue is empty
-rw------- 1 root mail 0 Sep  8 11:11 /var/spool/mail/root
[root@basecm10 ~]# cmsh -c "main; testemail"
Mail delivered to postfix
You have new mail in /var/spool/mail/root
[root@basecm10 ~]# mailq; ls -al /var/spool/mail/root
Mail queue is empty
-rw------- 1 root mail 749 Sep  8 11:12 /var/spool/mail/root
```

The test e-mail destination is the administrator e-mail address discussed in the preceding section.

#### 3.1.3.4  Failover Settings

To access the high availability (HA) feature of the cluster for head nodes, the administrator can click on the `Failover` option in Base View. This opens up a subwindow that can be used to configure HA-related parameters (section [17.4.6](/admin/ha#1746-high-availability-parameters)).

#### 3.1.3.5  Failover Groups Settings

To access the high availability feature of the cluster for groups of regular nodes, the administrator can click on the `Failover groups` option in Base View. This opens up a subwindow that can be used to configure failover-groups-related parameters (section [17.5](/admin/ha#175-ha-for-regular-nodes-and-edge-director-nodes)).

#### 3.1.3.6  Burn Configs

Burning nodes is covered in [Chapter 11 of the *Installation Manual*](/installation/burn). Burn configuration settings for the cluster can be accessed in Base View via the following navigation paths:

* `Cluster[Partition base]` > `Settings` > `Default burn configuration`

  This allows the `Default burn configuration` for a node burn run to be modified.

* `Cluster[Partition base]` > `Settings` > `Burn configs`

  This lists the possible burn configuration settings in a subwindow, and allows changes to some of their properties of each item of the list.

#### 3.1.3.7  FIPS Mode

To be compliant with the Federal Information Processing Standards of the USA, Linux-based systems are required to stick to some security standards. This is known as FIPS compliance.

FIPS compliance on regular nodes can be set per node or per category.

The existing FIPS status can be checked with the `sysinfo` command at node level:

**Example**

```bash
[head->device]% sysinfo node002
Name                      Value
------------------------- ---------------------------------
...
FIPS                      No
```

Or even just with a `get`:

**Example**

```bash
[head->device]% get node002 fips
no
```

FIPS can be enabled by node:

**Example**

```bash
[head->device]% set node002 fips yes
[head->device*]% commit
[head->device]% reboot node002
        [time passes]
        [node002 finishes reboot]
[head->device]% sysinfo node002 | grep FIPS
FIPS                      Yes
```

FIPS can be enabled by category:

**Example**

```bash
[head->device]% sysinfo node002
[head->device]% category
[head->category]% set default fips yes
[head->category*]% commit
Successfully committed 1 Categories
[head->category]%
...[notice] head: node001 [   UP   ], restart required (fips)
...[notice] head: node002 [   UP   ], restart required (fips)
[head->category]% device reboot -n node001..node002
[head->category]% device
[head->device]% get node001 fips; get node002 fips
yes
yes
```

As is usual in BCM, the node level setting overwrites the category level setting.

Setting FIPS compliance on the head node itself via CMDaemon is not allowed. This is because FIPS GRUB configuration could, in some unusual cases, result in an unbootable head node. The cluster administrator must consider the existing state of the head node with due care before manually re-configuring it for FIPS.

### 3.1.4  Limiting The Maximum Number Of Open Files

#### 3.1.4.1  Configuring The System Limit On Open Files: The `/proc/sys/fs/file-max` Setting

The maximum number of open files allowed on a running Linux operating system is determined by `/proc/sys/fs/file-max`. To configure this setting so that it is persistent, the Linux operating system uses a `/etc/sysctl.conf` file and `*.conf` files under `/etc/sysctl.d/`. Further information on these files can be found via the man page, `man sysctl.conf.5`. BCM adheres to this standard method, and places a settings file `90-cm-sysctl.conf` in the directory `/etc/sysctl.d`.

By default, the value set for `file-max` by NVIDIA Base Command Manager is 131072. An on-premises head node typically is not used to run applications that exceed this value, and the settings file `90-cm-sysctl.conf` is therefore not available for modification by the CMDaemon front ends (`cmsh` and Base View). For edge and cloud director installations, the installation scripts take care of modifying `file-max` since such installations can have many more open files. Cluster administrators are thus not expected to have a need to modify the value of `file-max` in most use cases.

However, if there is a need to modify the value of `file-max`, then a subsequent, extra, configuration file, such as `/etc/sysctl.d/91-site-sysctl-file-max-tweak.conf` can be added under `/etc/sysctl.d/`, so that the BCM version is not intefered with directly.

#### 3.1.4.2  Configuring The User Limit On Open Files: The `nofile` Setting

The maximum number of open files allowed for a user can be seen on running `ulimit -n`. The value is defined by the `nofile` parameter of ulimit.

By default the value set by BCM is 131072.

Ulimit limits are limits to restrict the resources used by users. If the `pam_limits.so` module is used to apply ulimit limits, then the resource limits can be set via the `/etc/security/limits.conf` file and `*.conf` files in the `/etc/security/limits.d` directory. Further information on these files can be found via the man page, `man limits.conf.5`.

Resource limits that can be set for user login sessions include the number of simultaneous login sessions, the number of open files, and memory limits.

The maximum number of open files for a user is unlimited by default in an operating system that is not managed by BCM. However, it is set to 131072 by default for a system managed by BCM. The `nofile` value is defined by BCM in:

* in `/etc/security/limits.d/91-cm-limits.conf` on the head node

* in `/cm/images/` \<*software image name*>`/etc/security/limits.d/91-cm-limits.conf` in the software image that the regular node picks up.

The values set in `91-cm-limits.conf` are typically sufficient for a user session, unless the user runs applications that are resource hungry and consume a lot of open files.

#### 3.1.4.3  Deciding On Appropriate Ulimit, Limit, And System Limit Values

Decreasing the `nofile` value in `/etc/security/limits.d/91-cm-limits.conf` (but leaving the `/proc/sys/fs/file-max` untouched), or increasing `/proc/sys/fs/file-max` (but leaving the `nofile` value of 131072 per session as is), may help the system stay under the maximum number of open files allowed.

In general, users should not be allowed to use the head node as a compilation server, or as a test bed, before running their applications. This is because user errors can unintentionally cause the head node to run out of resources and crash it.

Depending what is running on the server, and the load on it, the administrator may wish to increase the resource limit values.

A very rough rule-of-thumb that may be useful as a first approximation to set `file-max` optimally is suggested in the kernel source code. The suggestion is to simply multiply the system memory (in MB) by 10 per MB, and make the resulting number the `file-max` value. For example, if the node has 128 GB of memory, then 1280000 can be set as the `file-max` value.

Fine-tuning to try and ensure that the operating system no longer runs out of file handles, and to try and ensure the memory limits for handling the load are not exceeded, is best achieved via an empirical trial-and-error approach.

## 3.2  Network Settings

A simplified quickstart guide to setting up the external head node network configuration on a vendor-prepared cluster is given in [Chapter 6 of the *Installation Manual*](/installation/ipaddresschange). This section ([3.2](#32-network-settings)) covers network configuration more thoroughly.

After the cluster is set up with the correct license as explained in [Chapter 4 of the *Installation Manual*](/installation/licensing), the next configuration step is to define the networks that are present (sections [3.2.1](#321-configuring-networks) and [3.2.2](#322-adding-networks)).

During BCM installation at least three default network objects were created:

`internalnet`: the primary internal cluster network, and the default management network. This is used for booting non-head nodes and for all cluster management communication. In the absence of other internal networks, `internalnet` is also used for storage and communication between compute jobs. Changing the configuration of this network is described [here](#3234-changing-internal-network-parameters-for-the-cluster) under the subheading “Changing Internal Network Parameters For The Cluster”.

`externalnet`: the network connecting the cluster to the outside world (typically a corporate or campus network). Changing the configuration of this network is described [here](#3233-changing-external-network-parameters-for-the-cluster) under the subheading “Changing External Network Parameters For The Cluster”. This is the only network for which BCM also supports IPv6.

`globalnet`: the special network used to set the domain name for nodes so that they can be resolved whether they are cloud nodes or not. This network is described further [here](#3235-changing-the-global-network-parameters-for-the-cluster) under the subheading “Changing The Global Network Parameters For The Cluster”.

For a Type 1 cluster ([section 3.3.9 of the *Installation Manual*](/installation/installing#339-network-topology)) the internal and external networks are illustrated conceptually by figure [3.2](#fig-networksettingsconcepts).

![Network Settings Concepts](/base-command-manager/product-manuals/_fern-img/618198eec9a86292ad9098daf9211df5892f7d9bed3d52ca2701158f0a1e559e.webp)

*Figure 3.2: Network Settings Concepts*

The configuration of network settings is completed when, after having configured the general network settings, specific IP addresses are then also assigned to the interfaces of devices connected to the networks.

* Changing the configuration of the head node external interface is described [here](#theipaddressofthecluster) under the subheading “The IP address of the cluster”.

* Changing the configuration of the internal network interfaces is described [here](#theipaddressesandotherinterfacevaluesoftheinternalnetwork) under the subheading “The IP addresses and other interface values of the internal network”.

  * How to set a persistent identity for an interface—for example, to ensure that a particular interface that has been assigned the name `eth3` by the kernel keeps this name across reboots—is covered in section [5.8.1](/admin/provisioning#581-node-fails-to-pxe-boot), [here](/admin/provisioning#5811-interface-naming-conventions-post-rhel7-recommended).

* Changing the configuration of `globalnet` is described [here](#3235-changing-the-global-network-parameters-for-the-cluster) under the subheading “Changing The Global Network Parameters For The Cluster”. IP addresses are not configured at the `globalnet` network level itself.

### 3.2.1  Configuring Networks

The `network` mode in `cmsh` gives access to all network-related operations using the standard object commands. Section [2.5.3](/admin/clustermanagement#253-working-with-objects) introduces `cmsh` modes and working with objects.

In Base View, a network can be configured via the navigation path `Networking` > `Networks`, which opens up the `Network list` subwindow (figure [3.3](#fig-bright-view-networks)):

![Networks](/base-command-manager/product-manuals/_fern-img/b5c57f998248c557c1287dbe3e9fe1e075a4721aee61b191bd2666ec68d09909.webp)

*Figure 3.3: Networks*

In the context of the OSI Reference Model, each network object represents a layer 3 (i.e. Network Layer) IP network, and several layer 3 networks can be layered on a single layer 2 network (e.g. routes on an Ethernet segment).

Selecting a network such as `internalnet` or `externalnet` in the list of networks, for example by double-clicking the row, opens up a new `Overview` window for that network. Some resizing of the windows is usually needed to view the new window properly on a standard screen.

The `Overview` window by default lists the device names and device properties that are in the network. For example the `internal` network typically has some nodes, switches, and other devices attached to it, each with their IP addresses and interface (figure [3.4](#fig-bright-view-network-overview)).

![Network Overview](/base-command-manager/product-manuals/_fern-img/3822353453533ec5c345a2150d8a55d9e2c85d5087ecf18e69caf99dcfa23141.webp)

*Figure 3.4: Network Overview*

Selecting the `Settings` option opens a scrollable pane that allows a number of network properties to be changed (figure [3.5](#fig-bright-view-network-settings)).

![Network Settings](/base-command-manager/product-manuals/_fern-img/6396529c8293ca699222c92eede25001112961415b54f127eaf484d166b051f4.webp)

*Figure 3.5: Network Settings*

The properties of figure [3.5](#fig-bright-view-network-settings) are introduced in table [3.1](#tablenetwork-configuration-settings).

<table>
  <colgroup>
    <col />

    <col />
  </colgroup>

  <thead>
    <tr>
      <th>
        **Property**
      </th>

      <th>
        **Description**
      </th>
    </tr>
  </thead>

  <tbody>
    <tr>
      <td>
        `name`
      </td>

      <td>
        Name of this network.
      </td>
    </tr>

    <tr>
      <td>
        `Domain Name`
      </td>

      <td>
        DNS domain associated with the network.
      </td>
    </tr>

    <tr>
      <td>
        `Type`
      </td>

      <td>
        Menu options to set the network type. Options are 

        `Internal`

        , 

        `External`

        , 

        `Tunnel`

        , 

        `Global`

        , 

        `Cloud`

        , or 

        `NetMap`

         network.
      </td>
    </tr>

    <tr>
      <td>
        `MTU`
      </td>

      <td>
        Maximum Transmission Unit. The maximum size of an IP packet transmitted without fragmenting.
      </td>
    </tr>

    <tr>
      <td>
        `Node booting`
      </td>

      <td>
        Enabling means nodes are set to boot from this network (useful in the case of nodes on multiple networks). For an internal subnet called 

        `<`

        *subnet*

        `>`

        , when node booting is set, CMDaemon adds a subnet configuration 

        `/etc/dhcpd.<`

        *subnet*

        `>.conf`

         on the head node, which is accessed from 

        `/etc/dhcpd.conf`

        . 

        \


        • It can be set in Base View via the Networking resource, selecting a network, and then setting Node booting from within the network settings.

        \


        • It can be set in cmsh via the network mode, selecting a network, and then setting nodebooting.
      </td>
    </tr>

    <tr>
      <td>
        `Lock down dhcpd`
      </td>

      <td>
        Enabling means new nodes are not offered a PXE DHCP IP address from this network, i.e. DHCPD is “locked down”. A DHCP “deny unknown-clients” option is set by this action, so no new DHCP leases are granted to unknown clients for the network. Unknown clients are nodes for which BCM has no MAC addresses associated with the node. 

        \


        • It can be set in Base View via the Networking resource, selecting a network, and then setting Lock down dhcpd from within the network settings.

        \


        • It can be set in cmsh via the network mode, selecting a network, and then setting lockdowndhcpd.
      </td>
    </tr>

    <tr>
      <td>
        `Management allowed`
      </td>

      <td>
        Enabling means that the network has nodes managed by the head node.
      </td>
    </tr>

    <tr>
      <td>
        `Search domain index`
      </td>

      <td>
        The position of the network domain in the 

        `resolv.conf`

         file. A value of 

        `0`

         means the position is determined automatically.
      </td>
    </tr>

    <tr>
      <td>
        `Exclude from search domain`
      </td>

      <td>
        Enabling means the domain name for the network is not used.
      </td>
    </tr>

    <tr>
      <td>
        `Disable automatic exports`
      </td>

      <td>
        Enabling means that exports of built-in filesystems are not done automatically for the network.
      </td>
    </tr>

    <tr>
      <td>
        `Base address`
      </td>

      <td>
        Base address of the network (also known as the 

        *network address*

        ).
      </td>
    </tr>

    <tr>
      <td>
        `Broadcast address`
      </td>

      <td>
        Broadcast address of the network.
      </td>
    </tr>

    <tr>
      <td>
        `Dynamic range start/end`
      </td>

      <td>
        Start/end IP addresses of the DHCP range temporarily used by nodes during PXE boot on the internal network. These are addresses that do not conflict with the addresses assigned and used by nodes during normal use.
      </td>
    </tr>

    <tr>
      <td>
        `Netmask bits`
      </td>

      <td>
        Prefix-length, or number of bits in netmask. The part after the “/” in CIDR notation.
      </td>
    </tr>

    <tr>
      <td>
        `Gateway`
      </td>

      <td>
        Default route IP address
      </td>
    </tr>
  </tbody>
</table>

*Table 3.1: Network Configuration Settings*

In basic networking concepts, a network is a range of IP addresses. The first address in the range is the *base address*. The length of the range, i.e. the *subnet*, is determined by the *netmask*, which uses CIDR notation. CIDR notation is the so-called / (“slash”) representation, in which, for example, a CIDR notation of 192.168.0.1/28 implies an IP address of 192.168.0.1 with a traditional netmask of 255.255.255.240 applied to the 192.168.0.0 network. The netmask 255.255.255.240 implies that bits 28–32 of the 32-bit dotted-quad number 255.255.255.255 are unmasked, thereby implying a 4-bit-sized host range of 16 (i.e. 2\[4]) addresses.

The `sipcalc` utility installed on the head node is a useful tool for calculating or checking such IP subnet values (`man sipcalc.1` in the RHEL family of distributions, or `sipcalc -h` for help on this utility):

**Example**

```bash
user@basecm10:~$ sipcalc 192.168.0.1/28
-[ipv4 : 192.168.0.1/28] - 0

[CIDR]
Host address            - 192.168.0.1
Host address (decimal)  - 3232235521
Host address (hex)      - C0A80001
Network address         - 192.168.0.0
Network mask            - 255.255.255.240
Network mask (bits)     - 28
Network mask (hex)      - FFFFFFF0
Broadcast address       - 192.168.0.15
Cisco wildcard          - 0.0.0.15
Addresses in network    - 16
Network range           - 192.168.0.0 - 192.168.0.15
Usable range            - 192.168.0.1 - 192.168.0.14

```

Every network has an associated DNS domain which can be used to access a device through a particular network. For `internalnet`, the default DNS domain is set to `eth.cluster`, which means that the hostname `node001.eth.cluster` can be used to access device `node001` through the primary internal network. If a dedicated storage network has been added with DNS domain `storage.cluster`, then `node001.storage.cluster` can be used to reach `node001` through the storage network. Internal DNS zones are generated automatically based on the network definitions and the defined nodes on these networks. For networks marked as external, no DNS zones are generated.

### 3.2.2  Adding Networks

Once a network has been added, it can be used in the configuration of network interfaces for devices.

In Base View the `Add` button in the `Networks` subwindow (figure [3.3](#fig-bright-view-networks)) can be used to add a new network. After the new network has been added, the `Settings` pane (figure [3.5](#fig-bright-view-network-settings)) can be used to further configure the newly-added network.

In `cmsh`, a new network can be added from within `network` mode using the `add` or `clone` commands.

The default assignment of networks (internalnet to `Management network` and externalnet to `External network`) can be changed using Base View, via the `Settings` window of the cluster object (figure [3.1](#fig-bright-view-clustersettings)).

In `cmsh` the assignment to `Management network` and `External network` can be set or modified from the `base` object in `partition` mode:

**Example**

```bash
[root@basecm10 ~]# cmsh
[basecm10]% partition use base
[basecm10->partition[base]]% set managementnetwork internalnet; commit
[basecm10->partition[base]]% set externalnetwork externalnet; commit
```

### 3.2.3  Changing Network Parameters

After both internal and external networks are defined, it may be necessary to change network-related parameters from their original or default installation settings.

#### 3.2.3.1  Changing The Head Or Regular Node Hostname

To reach the `head node` from inside the cluster, the alias `master` may be used at all times. Setting the hostname of the head node itself to `master` is not recommended.

The name of a cluster is sometimes used as the hostname of the head node. The cluster name, the head node hostname, and the regular node hostnames, all have their own separate names as a property of their corresponding objects. The name can be changed in a similar manner for each.

For example, to change the hostname of the head node, the device object corresponding to the head node must be modified.

* In Base View, the navigation path for modifying the host name is `Devices` > `Head Nodes` > `Edit` > `Settings` > `Hostname` > `Save`. That is, under the `Devices` resource, the `Head Nodes` option is selected. The `Edit` button can then be used to edit the host. This opens up a pane, and the `Settings` option can then be selected. The `Hostname` record can then be modified (figure [3.6](#fig-bright-view-mastersettings)), and saved by clicking on the `Save` button. When setting a hostname, a domain is not included.

  After the change, as suggested by Base View, the head node must be rebooted.

![Head Node Settings](/base-command-manager/product-manuals/_fern-img/edab3a0a33e83fb90d6bb5ba86d84e1c9352e00cbf2ba058be69fea55c9e56b2.webp)

*Figure 3.6: Head Node Settings*

* In `cmsh`, the hostname of the head node can also be changed, via device mode:

  **Example**

  ```bash
  [root@basecm10 ~]# cmsh
  [basecm10]% device use basecm10
  [basecm10->device[basecm10]]% set hostname foobar
  [foobar->device*[foobar*]]% commit
  [foobar->device[foobar]]%
  Tue Jan 22 17:35:29 2013 [warning] foobar: Reboot required: Hostname changed
  [foobar->device[foobar]]% quit
  [root@basecm10 ~]# sleep 30; hostname -f foobar.cm.cluster
  [root@basecm10 ~]#
  ```

  The prompt string shows the new hostname after a short time, when a new shell is started.

  After the hostname has been set, as suggested by `cmsh`, the head node must be rebooted.

#### 3.2.3.2  Adding Hostnames To The Internal Network

Additional hostnames, whether they belong to the cluster nodes or not, can be added as name/value pairs to the `/etc/hosts` file(s) within the cluster. This should be done only outside the specially-marked CMDaemon-managed section. It can be done to the file on the head node, or to the file on the software image for the regular nodes, or to both, depending on where the resolution is required.

However, for hosts that are on the internal network of the cluster, such as regular nodes, it is easier and wiser to avoid adding additional hostnames via `/etc/hosts`.

Instead, it is recommended to let BCM manage host name resolution for devices on the `internalnet` through its DNS server on the `internalnet` interface. The host names can be added to the `additionalhostnames` object, from within `interfaces` submode for the head node. The `interfaces` submode is accessible from the `device` mode. Thus, for the head node, with `eth1` as the interface for `internalnet`:

**Example**

```bash
[basecm10]% device use basecm10
[basecm10->device[basecm10]]% interfaces
[basecm10->device[basecm10]->interfaces]% use eth1
[basecm10->device[basecm10]->interfaces[eth1]]% set additionalhostnames test
[basecm10->device*[basecm10*]->interfaces*[eth1*]]% commit
[basecm10->device[basecm10]->interfaces[eth1]]%
Fri Oct 12 16:48:47 2012 [notice] basecm10: Service named was restarted
[basecm10->device[basecm10]->interfaces[eth1]]% !ping test
PING test.cm.cluster (10.141.255.254) 56(84) bytes of data.
...
```

Multiple hostnames can be added as space-separated entries.

The `named` service automatically restarts within about 20 seconds after committal, implementing the configuration changes. This kind of restart is a feature (section [3.14.1](#3141-why-use-the-cluster-manager-for-services)) of changes made to service configurations by Base View or `cmsh`.

#### 3.2.3.3  Changing External Network Parameters For The Cluster

**The external network parameters of the cluster:** When a cluster interacts with an external network, such as a company or a university network, its connection behavior is determined by the settings of two objects: firstly, the external network settings of the `Networks` resource, and secondly, by the cluster network settings.

1. **The external network object** contains the network settings for all objects configured to connect to the external network, for example, a head node. Network settings are configured in Base View under the `Networking` resource, then under the `Networks` subwindow, then within the `Settings` option for a selected network. Figure [3.5](#fig-bright-view-network-settings) shows a settings window for when the `internalnet` item has been selected, but in the current case the `externalnet` item must be selected instead. The following parameters can then be configured:

   * the IP network parameters of the cluster (but not the IP address of the cluster):

     * `Base address`: the network address of the external network (the “IP address of the external network”). This is not to be confused with the IP address of the cluster, which is described shortly after this.

     * `Broadcast address`: the broadcast address of the external network. This is not to be confused with the IP address of the internal network ([here](#broadcast-internal)).

     * `Dynamic range start` and `Dynamic range end`: Not used by the external network configuration.

     * `Netmask bits`: the netmask size, or prefix-length, of the external network, in bits.

     * `Gateway`: the default route for the external network.

   * the `network name` (what the external network itself is called), by default this is defined as `externalnet` in the base partition on a newly installed Type 1 cluster,

   * the `Domain Name`: the network domain (LAN domain, i.e. what domain machines on the external network use as their domain),

   * the `External network` checkbox: this is checked for a Type 1 cluster,

   * and MTU size (the maximum value for a TCP/IP packet before it fragments on the external network—the default value is 1500).

2. **The cluster object** contains other network settings used to connect to the outside. These are configured in the `Settings` options of the cluster object resource in Base View (figure [3.1](#fig-bright-view-clustersettings)):

   * e-mail address(es) for the cluster administrator,

   * any additional external name servers used by the cluster to resolve external host names. As an aside: by default, only the head node name server is configured, and by default it only serves hosts on the internal network via the internal interface. Enabling the `PublicDNS` directive (Appendix [C.54](/admin/cmdconf#c54-publicdns-directive)) allows the head node name server to resolve queries about internal hosts from external hosts via any interface, including the external interface.

   * the DNS search domain (what the cluster uses as its domain),

   * and NTP time servers  (used to synchronize the time on the cluster with standard time) and time zone settings.

   These settings can also be adjusted in `cmsh` in the `base` object under `partition` mode.

Changing the networking parameters of a cluster (apart from the IP address of the cluster) therefore requires making changes in the settings of the two preceding objects.

**The IP address of the cluster:**  The cluster object itself does not contain an IP address value. This is because it is the cluster network topology type that determines whether a direct interface exists from the cluster to the outside world. Thus, the IP address of the cluster in the Type 1, Type 2, and Type 3 configurations ([section 3.3.9 of the *Installation Manual*](/installation/installing#339-network-topology)) is defined by the cluster interface that faces the outside world. For Type 1, this is the interface of the head node to the external network (figure [3.2](#fig-networksettingsconcepts)). For Type 2 and Type 3 interfaces the cluster IP address is effectively that of an upstream router, and thus not a part of BCM configuration. Thus, logically, the IP address of the cluster is not a part of the cluster object or external network object configuration.

For a Type 1 cluster, the head node IP address can be set in BCM, separately from the cluster object settings. This is then the IP address of the cluster according to the outside world.

**Setting the network parameters of the cluster and the head node IP address:** These values can be set using Base View or `cmsh`:

* ##### With Base View:

  The cluster network object and associated settings are accessed as follows:

  **The external network object:**

  The external network object is accessed via the navigation path `Networking` > `Networks` > `externalnet` > `Edit` > `Settings` which reaches the window shown in figure [3.7](#fig-bright-view-network-settings-externalnet):

![Network Settings For External Network](/base-command-manager/product-manuals/_fern-img/3c3acc11608431942982045587bd13ed01a86c970ba6a2bf0e3af27c20ccdfdf.webp)

*Figure 3.7: Network Settings For External Network*

**The cluster object:** The cluster object and associated settings are accessed as shown in figure [3.1](#fig-bright-view-clustersettings)

**The head node IP address:** For a head node `basecm10`, where the IP address is used by the interface `eth0`, the static IP address can be set via the navigation path `Devices` > `Head Nodes` > `Edit[basecm10]` > `Settings` > `JUMP TO` > `Interfaces` > `Edit`\[`eth0]` > `IP` (figure [3.8](#fig-bright-view-headnodeipaddress)).

![Setting The IP Address On A Head Node In Base View](/base-command-manager/product-manuals/_fern-img/0199f4bf9a800d02a5e7473fdf216333203cda1929afd6cb7cf9d81dbc2d558d.webp)

*Figure 3.8: Setting The IP Address On A Head Node In Base View*

* ##### With `cmsh`:

  The preceding Base View configuration can also be done in `cmsh`, using the `network`, `partition` and `device` modes, as in the following example:

  **Example**

  ```bash
  [basecm10]% network use externalnet
  [basecm10->network[externalnet]]% set baseaddress 192.168.1.0
  [basecm10->network*[externalnet*]]% set netmaskbits 24
  [basecm10->network*[externalnet*]]% set gateway 192.168.1.1
  [basecm10->network*[externalnet*]]% set -e gatewaymetric 1
  [basecm10->network*[externalnet*]]% commit
  [basecm10->network[externalnet]]% partition use base
  [basecm10->partition[base]]% set nameservers 192.168.1.1
  [basecm10->partition*[base*]]% set searchdomains x.com y.com
  [basecm10->partition*[base*]]% append timeservers ntp.x.com
  [basecm10->partition*[base*]]% commit
  [basecm10->partition[base]]% device use basecm10
  [basecm10->device[basecm10]]% interfaces
  [basecm10->device[basecm10]->interfaces]% use eth1
  [basecm10->device[basecm10]->interfaces[eth1]]% set ip 192.168.1.176
  [basecm10->device[basecm10]->interfaces*[eth1*]]% commit
  [basecm10->device[basecm10]->interfaces[eth1]]%
  ```

  After changing the external network configurations, a reboot of the head node is necessary to activate the changes.

**Using DHCP to supply network values for the external interface:**

Connecting the cluster via DHCP on the external network is not generally recommended for production clusters. This is because DHCP-related issues can complicate networking troubleshooting compared with using static assignments.

For a Type 1 network, the cluster and head node can be made to use some of the DHCP-supplied external network values as follows:

* In Base View, the DHCP setting of figure [3.8](#fig-bright-view-headnodeipaddress) can be set to `Enabled`

* Alternatively, in `cmsh`, within interfaces mode for the head node interface, the value of the parameter DHCP can be set:

  ```bash
  [basecm10->device[basecm10]->interfaces[eth0]]% set dhcp yes
  ```

The gateway address, the name server(s), and the external IP address of the head node are then obtained via a DHCP lease. Time server configuration for `externalnet` is not picked up from the DHCP server, having been set during installation ([figure 3.8 in Chapter 3 of the *Installation Manual*](/installation/installing#fig-clustersettings)). The time servers can be changed using Base View as in figure [3.1](#fig-bright-view-clustersettings), or using `cmsh` in `partition` mode as in the preceding example. The time zone can be changed similarly.

It is usually sensible to reboot after implementing these changes in order to test the changes are working as expected.

#### 3.2.3.4  Changing Internal Network Parameters For The Cluster

When a cluster interacts with the internal network that the regular nodes and other devices are on, its connection behavior with the devices on that network is determined by settings in:

1. the internal network of the `Networks` resource ([here](#internalnetworkobjectnetworksettings))

2. the cluster network for the internal network ([here](#internalnetworkparametersclusterobject))

3. the individual device network interface ([here](#theipaddressesandotherinterfacevaluesoftheinternalnetwork))

4. the node categories network-related items for the device ([here](#internalnetworknetworkingcategoryvalues)), in the case of the device being a regular node.

In more detail:

**1. The internal network object:**  has the network settings for all devices connecting to the internal network, for example, a login node, a head node via its `internalnet` interface, or a managed switch on the internal network. In Base View, the settings can be configured under the `Networking` resource, then under the `Networks` subwindow, then within the `Settings` option for the `internalnet` item (figure [3.5](#fig-bright-view-network-settings)). In `cmsh` the settings can be configured by changing the values in the `internalnet` object within `cmsh`’s `network` mode. Parameters that can be changed include:

* the IP network parameters of the internal network (but not the internal IP address):

* the “`domain name`” of the network. This is the LAN domain, which is the domain machines on this network use as their domain. By default, set to a name based on the network interface type used on the internal network, for example `eth.cluster`. In any case, the FQDN must be unique for every node in the cluster.

* the network name, or what the internal network is called. By default, set to `internalnet`.

* The `MTU` size, or the maximum value for a TCP/IP packet before it fragments on this network. By default, set to 1500.

**2. The cluster object:**  has other network settings that the internal network in the cluster uses. These particulars are configured in the `Settings` option of the cluster object resource in Base View (figure [3.1](#fig-bright-view-clustersettings)). The `cmsh` equivalents can be configured from the `base` object in `partition` mode. Values that can be set include:

* the “`Management network`”. This is the network over which CMDaemon manages the nodes. Management means that CMDaemon on the head node communicates with CMDaemons on the other nodes. The communication includes CMDaemon calls and monitoring data. By default, the management network is set to `internalnet` for Type 1 and Type 2 networks, and `managementnet` in Type 3 networks. It is a partition-level cluster-wide setting by default. Partition-level settings can be overridden by the category level setting, and node-level settings can override category level or partition level settings.

* the “`Node name`” can be set to decide the prefix part of the node name. By default, set to `node`.

* the “`Node digits`” can be set to decide the possible size of numbers used for suffix part of the node name. By default, set to `3`.

* the “`Default category`”. This sets the category the nodes are in by default. By default, it is set to `default`.

* the “`Default software image`”. This sets the image the nodes use by default, for new nodes that are not in a category yet. By default, it is set to `default-image`.

* the “`Name server`”. This sets the name server used by the cluster. By default, it is set to the head node. The default configuration uses the internal network interface and serves only internal hosts. Internal hosts can override using this value at category level ([here](#3234-changing-internal-network-parameters-for-the-cluster)). By default external hosts cannot use this service. To allow external hosts to use the service for resolving internal hosts, the `PublicDNS` directive (Appendix [C.54](/admin/cmdconf#c54-publicdns-directive)) must be set to `True`.

**3. The internal IP addresses and other internal interface values:**  In Base View, the network for a node, such as a physical node `node001`, can be configured via a navigation path `Devices` > `Nodes[node001]` > `Interface`. The subwindow that opens up then allows network configuration to be done for such nodes in a similar way to figure [3.8](#fig-bright-view-headnodeipaddress). In `cmsh` the configuration can be done by changing properties from the `interfaces` submode that is within the `device` mode for the node.

The items that can be set include:

* the `Network device name`: By default, this is set to `BOOTIF` for a node that boots from the same interface as the one from which it is provisioned.

* the `Network`: By default, this is set to a value of `internalnet`.

* the `IP` address: By default, this is automatically assigned a static value, in the range `10.141.0.1` to `10.141.255.255`, with the first node being given the first address. Using a static IP address is recommended for reliability, since it allows nodes that lose connectivity to the head node to continue operating. The static address can be changed manually, in case there is an IP address or node ID conflict due to an earlier inappropriate manual intervention.

  Administrators who want DHCP addressing on the internal network, despite the consequences, can set it via a checkbox.

* `onnetworkpriority`: This sets the priority of DNS resolution queries for the interface on the network. The range of values that it can take is from 0 to 4294967295. Resolution takes place via the interface with the higher value.

  The default priority value for a network interface is set according to its type. These defaults are:

  | **Type** | **Value** |
  | :------- | :-------- |
  | Bridge   | 80        |
  | Bond     | 70        |
  | Physical | 60        |
  | VLAN     | 50        |
  | Alias    | 40        |
  | Tunnel   | 30        |
  | Netmap   | 20        |
  | BMC      | 10        |

* `Additional Hostname`: In the case of nodes this is in addition to the default node name set during provisioning. The node name set during provisioning takes a default form of `node` \<*`3 digit number`*>, as explained earlier [here](#internalnetworkparametersclusterobject) in the section describing the cluster object settings.

For, example, a regular node that has an extra interface, `eth1`, can have its values set as follows:

**Example**

```bash
[basecm10] device interfaces node001
[basecm10->device[node001]->interfaces]% add physical eth1
[basecm10->...->interfaces*[eth1*]]% set network externalnet
[basecm10->...->interfaces*[eth1*]]% set additionalhostnames extra01
[basecm10->...->interfaces*[eth1*]]% set ip 10.141.1.1
[basecm10->...->interfaces*[eth1*]]% commit
[basecm10->...->interfaces[eth1]]% ..
[basecm10->...->interfaces]% ..
[basecm10->device[node001]]% reboot
```

**4. Node category network values:**  are settings for the internal network that can be configured for node categories. For example, for the default category called `default` this can be carried out:

* via Base View, using the `Settings` option for `Node categories`. This is in the navigation path `Grouping` > `Node categories[default-image]` > `Settings`

* or via the `category` mode in `cmsh`, for the `default` node category.

If there are individual node settings that have been configured in Base View or `cmsh`, then the node settings override the corresponding category settings for those particular nodes.

The category properties involved in internal networking that can be set include:

* `Default gateway`: The default gateway route for nodes in the node category. If unset, or 0.0.0.0 (the default), then the node default gateway route is decided by the internal network object `Gateway` value. If the default gateway is set as a node category value, then nodes use the node category value as their default gateway route instead.

* `Management network`: The management network is the network used by CMDaemon to manage devices. The default setting is a property of the node object. It can be set as a category property.

* `Name server`, `Time server`, `Search domain`: The default setting for these on all nodes is set by the node-installer to refer to the head node, and is not configurable at the node level using Base View or `cmsh`. The setting can however be set as a category property, either as a space-separated list of entries or as a single entry, to override the default value.

**Application To Generic Network Devices:**  The preceding details for the internal network parameters of the cluster, starting from [here](#3234-changing-internal-network-parameters-for-the-cluster), are applicable to regular nodes, but they are often also applicable to generic network devices (section [2.1.1](/admin/clustermanagement#211-devices)). Benefits of adding a generic device to be managed by BCM include that:

* the name given to the device during addition is automatically placed in the internal DNS zone, so that the device is accessible by name

* the device status is automatically monitored via an ICMP ping (Appendix [G.2.1](/admin/metricshealthchecksactions#g21-regular-health-checks)).

* the device can be made to work with the health check and metric framework. The scripts used in the framework will however almost certainly have to be customized to work with the device

After changing network configurations, a reboot of the device is necessary to activate the changes.

#### 3.2.3.5  Changing The Global Network Parameters For The Cluster

The global network `globalnet` is a unique network used to set up a common name space for all nodes in a cluster in BCM. It is required in BCM because of the added cloud extension functionality, described in the *Cloudbursting Manual*. Regular nodes and regular cloud nodes are thus both named under the `globalnet` domain name, which is `cm.cluster` by default. So, for example, if default host names for regular nodes (node001, node002, ...) and regular cloud nodes (cnode001, cnode002, ...) are used, node addresses with the domain are:

* node001.cm.cluster for node001

* cnode001.cm.cluster for cnode001

The only parameter that can be sensibly changed on `globalnet` is the domain name, which is `cm.cluster` by default.

Removing `globalnet` should not be done because it will cause various networking failures, even for clusters deploying no cloud nodes.

Details on how resolution is carried out with the help of `globalnet` are given in [section 6.6.1 of the *Cloudbursting Manual*](/cloudbursting/cloudconsiderations#661-resolution-and-globalnet).

#### 3.2.3.6  Setting Static Routes In The `staticroutes` Submode Of `cmsh`

To route via a specific gateway, the `staticroutes` submode can be used. This can be set for regular nodes and head nodes via the `device` mode, and for node categories via the `category` mode.

On a newly-installed cluster with a type 1 network ([section 3.3.9 of the *Installation Manual*](/installation/installing#339-network-topology)), a node by default routes packets using the head node as the default gateway.

If the administrator would like to configure a regular node to use another gateway to reach a printer on another subnet, as illustrated by figure [3.9](#fig-staticroute-to-a-printer):

![Example Of A Static Route To A Printer On Another Subnet](/base-command-manager/product-manuals/_fern-img/f1d39212878c9946149a3ce872005c83e9c393372609a04f86ed2da62ed20780.webp)

*Figure 3.9: Example Of A Static Route To A Printer On Another Subnet*

then an example session for setting the static route is as follows:

**Example**

```bash
[root@basecm10 ~]# cmsh
[basecm10 ]% device use node001
[basecm10->device[node001]]%
[basecm10->device[node001]]% staticroutes
[basecm10->device[node001]->staticroutes]% list
Name (key)                       Gateway          Destination
-------------------------------- ---------------- --------------
[basecm10->device[node001]->staticroutes]% add printerroute
[basecm10->...*[printerroute*]]% set gateway 10.141.1.1
[basecm10->...*[printerroute*]]% set destination 192.168.0.3
[basecm10->...*[printerroute*]]% set networkdevicename bootif
[basecm10->...*[printerroute*]]% commit
[basecm10->...[printerroute]]% show
Parameter                        Value
-------------------------------- -------------------------------
Destination                      192.168.0.3/32
Gateway                          10.141.1.1
Name                             printerroute
Network Device Name              bootif
Revision
[basecm10->device[node001]->staticroutes[printerroute]]% exit
[basecm10->device[node001]->staticroutes]% list
Name (key)                       Gateway          Destination
-------------------------------- ---------------- --------------
printerroute                     10.141.1.1       192.168.0.3/32
[basecm10->device[node001]->staticroutes]% exit; exit
[basecm10->device]% reboot node001
```

In the preceding example, the regular node `node001`, with IP address 10.141.0.1 can connect to a host 192.168.0.3 outside the regular node subnet using a gateway with the IP addresses 10.141.1.1 and 192.168.0.1. The route is given the arbitrary name `printerroute` for administrator and CMDaemon convenience, because the host to be reached in this case is a print server. The `networkdevicename` is given the interface name `bootif`. If another device interface name is defined in CMDaemon, then that can be used instead. If there is only one interface, then `networkdevicename` need not be set.

After a reboot of the node, the route that packets from the node follow can be seen with a traceroute or similar. The `ping` utility with the `-R` option can often track up to 9 hops, and can be used to track the route:

**Example**

```bash
[root@basecm10 ~]# ssh node001 ping -c1 -R 192.168.0.3
PING 192.168.0.3 (192.168.0.3) 56(124) bytes of data.
64 bytes from 192.168.0.3: icmp_seq=1 ttl=62 time=1.41 ms
RR:     10.141.0.1
        10.141.1.1
        192.168.0.1
        192.168.0.3
        192.168.0.3
        192.168.0.1
        10.141.1.1
        10.141.0.1

--- 192.168.0.3 ping statistics ---
1 packets transmitted, 1 received, 0% packet loss, time 1ms
rtt min/avg/max/mdev = 1.416/1.416/1.416/0.000 ms
[root@basecm10->device[node001]->staticroutes]%
```

The routing is achieved by CMDaemon making sure that whenever the network interface is brought up, the OS of the regular node runs a routing command to configure the routing tables. The command executed for the given example is either:

```bash
    route add -host 192.168.0.3 gw 10.141.1.1
```

or its modern iproute2 equivalent:

```bash
    ip route add 192.168.0.3 via 10.141.1.1
```

If the device `bootif` is `eth0`—which is often the case—then the command is run from the network interface configuration file: `/etc/sysconfig/network-scripts/ifcfg-eth0` (or `/etc/sysconfig/network/ifcfg-eth0` in SUSE).

### 3.2.4  Tools For Viewing Cluster Connections And Connectivity

#### 3.2.4.1  Viewing Node Routes With `routes` In `cmsh`

The `cmsh` `routes` command is a wrapper around the Linux `route` command, and is designed to run in parallel over nodes. It is intended to get a fast route overview for one or more nodes, and display it for easy comparison.

To get a full overview of the routes for all nodes, the command is run without any options:

**Example**

```bash
[root@basecm10 ~]# cmsh
[basecm10]% device
[basecm10->device]% routes
Hostname  Destination      Gateway          Netmask          Flags     Metric  Ref  Use  Interface
--------- ---------------- ---------------- ---------------- --------- ------- ---- ---- ---------
basecm10 0.0.0.0          192.168.255.254  0.0.0.0          UG (0003)  0       0    0    eth1
basecm10 10.141.0.0       0.0.0.0          255.255.0.0      U (0001)   0       0    0    eth0
basecm10 169.254.169.254  192.168.241.1    255.255.255.255  UGH (0007) 0       0    0    eth1
basecm10 192.168.240.0    0.0.0.0          255.255.240.0    U (0001)   0       0    0    eth1
node001  0.0.0.0          10.141.255.254   0.0.0.0          UG (0003)  0       0    0    ens3
node001  10.141.0.0       0.0.0.0          255.255.0.0      U (0001)   0       0    0    ens3
```

To select or filter the output, the grouping options of `routes`, or the text processing utility `awk` can be used. Grouping options are options to select nodes, groups, categories, and so on, and are described in the cluster management chapter, [here](/admin/clustermanagement#2559-looping-over-objects-with-foreach), while a handy link for `awk` one-liners is [http://tuxgraphics.org/\~guido/scripts/awk-one-liner.html](http://tuxgraphics.org/~guido/scripts/awk-one-liner.html).

Selection or filtering makes it very easy to detect badly-configured nodes. For example, when the expected gateway is \<*expected-gateway*>, the following command may be used to display only the unexpected gateways:

**Example**

```bash
[root@basecm10 ~]# cmsh
[basecm10]% device
[basecm10->device]% routes --category default | awk '{if ($3 != "<expected-gateway>") print $0}'
...
```

#### 3.2.4.2  Viewing Connections In `cmsh`

The `connections` command can be run from within the `device` mode of `cmsh` It is a parallel wrapper to view active TCP and UDP connections. That is, it runs as a simple command over multiple devices at the same time.

Running `connections` without options displays a full overview of the currently active TCP and UDP ports on all devices (output truncated):

**Example**

```bash
[basecm10->device]% connections
Node      Type     Source   Port  Destination  Port  State
--------- -------- -------- ----- ------------ ----- ----------
basecm10  TCP      0.0.0.0  22    0.0.0.0      0     Listening
basecm10  TCP      0.0.0.0  25    0.0.0.0      0     Listening
basecm10  TCP      0.0.0.0  111   0.0.0.0      0     Listening
basecm10  TCP      0.0.0.0  636   0.0.0.0      0     Listening
...
```

Filtering with `grep` can then show which nodes are listening on which ports. For example, nodes listening for DNS queries (port 53) can be found with:

**Example**

```bash
[basecm10->device]% connections | head -2; connections | grep Listen | grep " 53"
Node      Type     Source             Port     Destination     Port     State
--------- -------- ------------------ -------- --------------- -------- -----------
basecm10  TCP      10.141.255.254     53       0.0.0.0         0        Listening
basecm10  TCP      127.0.0.1          53       0.0.0.0         0        Listening
basecm10  TCP      192.168.200.162    53       0.0.0.0         0        Listening
```

and shows that only the head node is listening on that port, providing DNS.

Some third party tools require a free port on all nodes for a service to listen on. Filtering and sorting the output of the connections command allows the administrator to find all the existing used ports across all nodes:

**Example**

```bash
[basecm10->device]% connections | awk 'print $4' | sort -un
Port
22
25
53
67
68
69
...
```

Options to the `connections` command can be seen by running `help connections`. Options include node grouping options (such as `-n|--nodes`, `-c|--category`, and `-t|--type`), and filtering out TCP6 and UDP6 connections (`--no-tcp6`, `--no-udp6`).

#### 3.2.4.3  Viewing Connectivity in `cmsh`

The `connectivity` command can be run from within the `device` mode of `cmsh`. It runs ICMP pings along each node route on a network of the cluster. By default the network is the management network.

By default the output displays if the connection is OK, the ping sequence ID (counting starts from zero), and the latency between the source and destination:

**Example**

```bash
[basecm10->device]% connectivity
Source    Destination Result       ID   Latency
--------- ----------- ------------ ---- ------------
basecm10  node001     Ok           0    0.4ms
basecm10  node002     Ok           0    0.3ms
basecm10  node003     Ok           0    0.4ms
basecm10  basecm10    Ok           0    0.1ms
```

Pings where the source and destination have identical names are carried out via identical interfaces.

Further options to the `connectivity` command can be seen by running `help connectivity`. Options include the ability to set ping timeouts and the cluster network on which to ping, as well as node grouping options.

For larger clusters, the following type of connectivity check may be a helpful diagnostic:

**Example**

```bash
[basecm10->device]% connectivity --statistics --count 100 --delay 0.01
Name        Value
----------- --------
OK          400
Total       400
Count       2
Average     0.35ms
Minimum     0.35ms
Maximum     0.35ms
Uniformity  100.0%
```

The preceding shows how uniform nodes are in ping timings. A significant spread in uniformity can indicate network problems.

#### 3.2.4.4  Viewing Network Performance With `cm-iperf.py`

A handy tool for checking the network performance of the nodes on a cluster is `cm-iperf.py`.

The nodes to be checked must be specified with the `-n|--node` option:

**Example**

```bash
basecm10:~#  /cm/local/apps/cmd/scripts/cm-iperf.py  -n node001..node004
Thread  Port    Server          Client          Target          Bitrate
======= ======= =============== =============== =============== =================
0       5000    node001         node002         node001         7.89 Gbits/sec
0       5001    node001         node003         node001         7.84 Gbits/sec
0       5002    node001         node004         node001         8.22 Gbits/sec
0       5003    node002         node003         node002         7.53 Gbits/sec
0       5004    node002         node004         node002         8.60 Gbits/sec
0       5005    node003         node004         node003         7.59 Gbits/sec
```

For a Type 1 cluster ([section 3.3.9 of the *Installation Manual*](/installation/installing#339-network-topology)) with n nodes, the total number of connection pairs that can be evaluated is:

```math
\left(\begin{matrix}
    n\\
        2
  \end{matrix}\right) = \cfrac{(n)(n-1)}{2}
```

For a 4-node cluster this means 6 network connection pairs are displayed, as is seen in the preceding example.

Each pair is checked for about 10s. This means that for a 1000-node cluster, the time for a default run would take about 2 months. The following options are therefore useful:

* `--count`: specify the number of pairs that are checked

* `-r|--random`: have the connection pairs chosen in a random sequence

* `-p|--parallel`: specify the number of parallel threads to runs the process

**Example**

```bash
basecm10:~#  /cm/local/apps/cmd/scripts/cm-iperf.py  -n node001..node004 --count 5 -r -p 2
```

Further options can be viewed with the `-h|--help` option.

## 3.3  Configuring Bridge Interfaces

Bridge interfaces can be used to divide one physical network into two separate network segments at layer 2 without creating separate IP subnets. A bridge thus connects the two networks together at layer 3 in a protocol-independent way.

The network device name given to the bridge interface is of the form `br`*`<number>`*. The following example demonstrates how to set up a bridge interface in `cmsh`, where the name `br0` is stored by the parameter `networkdevicename`.

**Example**

```bash
[basecm10->device[node001]->interfaces]% add bridge br0
[basecm10->...->interfaces*[br0*]]% set network internalnet
[basecm10->...->interfaces*[br0*]]% set ip 10.141.1.1
[basecm10->...->interfaces*[br0*]]% show
Parameter                      Value
------------------------------ ------------------
Additional Hostnames
DHCP                           no
Forward Delay                  0
IP                             10.141.1.1
Interfaces
MAC                            00:00:00:00:00:00
Network                        internalnet
Network device name            br0
Revision
SpanningTreeProtocol           no
Type                           bridge
```

A bridge interface is composed of one or more physical interfaces. The IP and network fields of the member interfaces must be empty:

**Example**

```bash
[basecm10->...->interfaces*[br0*]]% set interfaces eth1 eth2; exit
[basecm10->...->interfaces*]% clear eth1 ip; clear eth1 network
[basecm10->...->interfaces*]% clear eth2 ip; clear eth2 network
[basecm10->...->interfaces*]% use br0; commit
```

The `BOOTIF` interface is also a valid interface option.

Currently, the following bridge properties can be set:

* `SpanningTreeProtocol`: sets the spanning tree protocol to be on or off. The default is off.

* `Forward Delay`: sets the delay for forwarding Ethernet frames, in seconds. The default is 0.

Additional properties, if required, can be set manually using the `brctl` command in the OS shell.

When listing interfaces in `cmsh`, if an interface is a member of a bond (or bridge) interface, then the corresponding bond or bridge interface name is shown in parentheses after the member interface name:

**Example**

```bash
[headnode->device[node001]->interfaces]% list
Type         Network device name  IP               Network
------------ -------------------- ---------------- ----------------
bond         bond0 [prov]         10.141.128.1     internalnet
bridge       br0                  10.141.128.2     internalnet
physical     eth0                 10.141.0.1       internalnet
physical     eth1 (bond0)         0.0.0.0
physical     eth2 (bond0)         0.0.0.0
physical     eth3 (br0)           0.0.0.0
physical     eth4 (br0)           0.0.0.0
```

It is possible to create a bridge interface with no IP address configured, that is, with an IP address of 0.0.0.0. This can be done for security reasons, or when the number of available IP addresses on the network is scarce. As long as such a bridge interface has a network assigned to it, it is properly configured on the nodes and functions as a bridge on the network.

## 3.4  Configuring VLAN interfaces

A VLAN (Virtual Local Area Network) is an independent logical LAN within a physical LAN network. VLAN tagging is used to segregate VLANs from each other. VLAN tagging is the practice of inserting a VLAN ID tag into a packet frame header, so that each packet can be associated with a VLAN.

The physical network then typically has sections that are VLAN-aware or VLAN-unaware. The nodes and switches of the VLAN-aware section are configured by the administrator to decide which traffic belongs to which VLAN.

A VLAN interface can be configured for an interface within BCM using `cmsh` or Base View.

### 3.4.1  Configuring A VLAN Interface Using `cmsh`

In the following `cmsh` session, a regular node interface that faces a VLAN-aware switch is made VLAN-aware, and assigned a new interface—an alias interface. It is also assigned a network, and an IP address within that network:

**Example**

```bash
[root@basecm10 ~]# cmsh
[basecm10]% device interfaces node001
[basecm10->device[node001]->interfaces]% list
Type         Network device name  IP             Network
------------ -------------------- -------------- ------------
physical     BOOTIF [prov]        10.141.0.1     internalnet
[basecm10->device[node001]->interfaces]% list -h | tail -4
Arguments:
   type
     alias, bmc, bond, bridge, netmap, physical, tunnel, vlan

[basecm10->device[node001]->interfaces]% add vlan BOOTIF.1
[basecm10->device*[node001*]->interfaces*[BOOTIF.1*]]% commit
[basecm10->device[node001]->interfaces[BOOTIF.1]]% show

Parameter                 Value
------------------------- ------------------------
Additional Hostname
DHCP                      no
IP                        0.0.0.0
MAC                       00:00:00:00:00:00
Network
Network device name       BOOTIF.1
Reorder HDR               no
Revision
Type                      vlan
[basecm10->...[BOOTIF.1]]% set network internalnet
[basecm10->...[BOOTIF.1*]]% set ip 10.141.2.1; commit
```

The `Reorder HDR` setting in a VLAN, if enabled, moves the ethernet header around to make it look exactly like a real ethernet device. This setting controls the `REORDER_HDR` setting in the file at `/etc/sysconfig/network-scripts/ifcfg-` \<*interface*> on the node.

### 3.4.2  Configuring A VLAN Interface Using Base View

Within Base View a VLAN interface can be added for a node such as `node001` via the navigation path:\
`Devices` > `Nodes` > `Edit[node001]` > `Settings` > `JUMP TO` > `Interfaces` > `+ADD`\[`Network VLAN interface]`\
(figure [3.10](#fig-bright-view-configuring-vlan)).

![Configuring a VLAN via Base View](/base-command-manager/product-manuals/_fern-img/71b0dd051a8017ab9f9106a1d7cec009233a9f2aef02788b885fddf32e4645b7.webp)

*Figure 3.10: Configuring a VLAN via Base View*

A `Network VLAN Interface` window opens up, allowing an IP address, network, and other options to be configured for the VLAN interface.

## 3.5  Configuring Bonded Interfaces

### 3.5.1  Adding A Bonded Interface

The Linux bonding driver allows multiple physical network interfaces that have been configured previously (for example, as [here](#3234-changing-internal-network-parameters-for-the-cluster)) to be bonded as a single logical bond interface. The behavior of such interfaces is determined by their bonding mode. The modes provide facilities such as hot standby or load balancing.

The driver is included by default on head nodes. To configure a non-head node to use a bonded interface, a Linux kernel module called the `bonding` module must be included in the kernel modules list of the software image of the node. A bonding interface can then be created, and its properties set as follows:

**Example**

```bash
[basecm10->device[node001]->interfaces]% add bond bond0
[...->device*[node001*]->interfaces*[bond0*]]% set network internalnet
[...->device*[node001*]->interfaces*[bond0*]]% set ip 10.141.128.1
[...->device*[node001*]->interfaces*[bond0*]]% set mode 3
[...->device*[node001*]->interfaces*[bond0*]]% set interfaces eth1 eth2
```

Each bonded interface has a unique set of object properties, called bonding options, that specify how the bonding device operates. The bonding options are a string containing one or more options formatted as `option=value` pairs, with pairs separated from each other by a space character.

A bonded interface also always has a mode associated with it. By default it is set to `0`, corresponding to a balanced round-robin packet transmission.

The 7 bonding modes are:

* 0 – balance-rr

* 1 – active-backup

* 2 – balance-xor

* 3 – broadcast

* 4 – 802.3ad

* 5 – balance-tlb

* 6 – balance-alb

Technically, outside of Base View or `cmsh`, the bonding mode is just another bonding option specified as part of the options string. However in BCM the bonding mode value is set up using the dedicated `mode` property of the bonded interface, for the sake of clarity. To avoid conflict with the value of the `mode` property, trying to commit a bonding mode value as an `option=value` pair will fail validation.

### 3.5.2  Single Bonded Interface On A Regular Node

A single bonded interface on a node can be configured and coexist in several ways on nodes with multiple network interfaces. Possibilities and restrictions are illustrated by the following:

* The bonded interface may be made up of two member interfaces, and a third interface outside of the bond could be the boot interface. (The boot interface is the node interface used to PXE boot the node before the kernel loads (section [5.1](/admin/provisioning#51-before-the-kernel-loads))).

* The boot interface could itself be a member of the bonded interface. If the boot interface is a member of a bonded interface, then this is the first bonded interface when interfaces are listed as in the example [here](#33-configuring-bridge-interfaces).

* The bonded interface could be set up as the provisioning interface. However, the provisioning interface cannot itself be a member of a bonded interface. (The provisioning interface is the node’s interface that picks up the image for the node after the initial ramdisk is running. Chapter [5](/admin/provisioning) covers this in more detail).

* A bonded interface can be set up as the provisioning interface, while having a member interface which is used for PXE booting.

### 3.5.3  Multiple Bonded Interface On A Regular Node

A node can also have multiple bonded interfaces configured. Possibilities and restrictions are illustrated by the following:

* Any one of the configured bonded interfaces can be configured as the provisioning interface. However, as already mentioned in the case of single bond interfaces (section [3.5.2](#352-single-bonded-interface-on-a-regular-node)), a particular member of a bonded interface cannot be made the provisioning interface.

* When a bonded interface is set as the provisioning interface, then during the node-installer phase of boot, the node-installer brings up the necessary bonded interface along with all its member interfaces so that node provisioning is done over the bonded interface.

### 3.5.4  Bonded Interfaces On Head Nodes And HA Head Nodes

It is also possible to configure bonded interfaces on head nodes.

For a single head node setup, this is analogous to setting up bonding on regular nodes.

For a high availability (HA) setup (chapter [17](/admin/ha)), bonding is possible for `internalnet` as well as for `externalnet`, but it needs the following extra changes:

* For the bonded interface on `internalnet`, the shared internal IP alias interface name (the value of `networkdevicename`, for example, `eth0:0` in figure [17.1](/admin/ha#1714-failover-network-topology)) for that IP address should be renamed to the bonded alias interface name on `internalnet` (for example, `bond0:0`).

* For the bonded interface on `externalnet`, the shared external IP alias interface name (the value of `networkdevicename`, for example, `eth1:0` in figure [17.1](/admin/ha#1714-failover-network-topology)) for that IP address should be renamed to the bonded alias interface name on `externalnet` (for example, `bond1:0`).

* Additionally, when using a bonded interface name for the internal network, the value of the provisioning network interface name (the value of `provisioninginterface`, for example, `eth0`) for the head nodes, must be changed to the name of the bonded interface (for example, `bond0 [prov]`) on the internal network. The `provisioninginterface` value setting is described further [here](/admin/provisioning#5473-interface-used-to-receive-image-data-provisioninginterface).

  **Example**

  ```bash
  [headnode1->device[headnode1]->interfaces]% list
  Type         Network device name  IP               Network
  ------------ -------------------- ---------------- ------------
  alias        bond0:0              10.141.255.252   internalnet
  alias        bond1:0              10.150.57.1      externalnet
  bond         bond0 [prov]         10.141.255.254   internalnet
  bond         bond1                10.150.57.3      externalnet
  physical     eth0 (bond0)         0.0.0.0
  physical     eth1 (bond0)         0.0.0.0
  physical     eth2 (bond1)         0.0.0.0
  physical     eth3 (bond1)         0.0.0.0
  ```

### 3.5.5  Tagged VLAN On Top Of a Bonded Interface

It is possible to set up a tagged VLAN interface on top of a bonded interface. There is no requirement for the bonded interface to have an IP address configured in this case. The IP address can be set to `0.0.0.0`, however a network must be set.

**Example**

```bash
[headnode1->device[node001]->interfaces]% list
Type         Network device name  IP               Network
------------ -------------------- ---------------- ------------
bond         bond0                0.0.0.0          internalnet
physical     eth0 [prov]          10.141.0.1       internalnet
physical     eth1 (bond0)         0.0.0.0
physical     eth2 (bond0)         0.0.0.0
vlan         bond0.3              10.150.1.1       othernet
```

### 3.5.6  Association Of MAC Address With A Bonded Interface

BCM has MAC settings for interfaces as well as for nodes.

When a node is provisioned via PXE booting (Chapter [5](/admin/provisioning)), the MAC on the NIC that is being booted from is matched with the MAC property of the node. This is how the node is identified.

If a bonded interface is used, then any interface may be used for PXE booting. Each interface has its own MAC address, which means that the interface MAC address may not match the assigned node MAC address. In BCM 11 and later versions, the node-installer recognizes any MAC address in a bonded interface.

### 3.5.7  Further Notes On Bonding

If using bonding to provide failover services, then the kernel module option setting for media independent interface monitoring, `miimon`, which is set to be off by default (set to 0), should be given a non-zero value.

The `miimon` setting is the time period in milliseconds between checks of the interface carrier state. A common value is `miimon=100`.

Its value is set in the bonding device configuration file.

* For RHEL and derivatives, and for SLES distributions, the file is in a network script along a file path such as `/etc/sysconfig/network-scripts/ifcfg-bond0`.

  The line within the stanza for the `ifcfg-bond0` file might look like:

  **Example**

  ```bash
      BONDING_MODULE_OPTS="mode=active-backup miimon=100"
  ```

  and can be set manually.

  * For RHEL and derivatives, it can alternatively be configured with front-end tools such as the `nmcli` tool, `nmtui`, or others.

    **Example**

    ```bash
        # nmcli connection add type bond con-name bond0 ifname bond0 bond.options \
          "mode=active-backup,miimon=100"
    ```

  * For SLES, YaST can be used as a front-end tool (`YaST` > `System` > `Network Settings`).

* For Ubuntu, the interface definitions are in a file, either `/etc/network/interfaces`, or a file under `/etc/network/interfaces.d/`.

  The line to set the value of `miimon` follows a form such as:

  * `bond-miimon 100`

  instead of

  * `miimon=100`

  and can be set manually.

  Alternatively, Canonical’s `netplan` ([https://netplan.io](https://netplan.io)) utility can be used to set the network configuration files. The `netplan` YAML configuration key to set `bond-miimon` is [`mii-monitor-interval.`](https://netplan.io/reference#properties-for-device-type-bonds)

When listing interfaces in `cmsh`, if an interface is a member of a bond or bridge interface, then the corresponding bonded or bridge interface name is shown in parentheses after the member interface name. Section [3.3](#33-configuring-bridge-interfaces), on configuring bridge interfaces, shows an example of such a listing from within `cmsh` [here](#33-configuring-bridge-interfaces).

More on bonded interfaces (including a detailed description of bonding options and modes) can be found at [http://www.kernel.org/doc/Documentation/networking/bonding.txt](http://www.kernel.org/doc/Documentation/networking/bonding.txt).

## 3.6  Configuring InfiniBand Interfaces

On clusters with an InfiniBand interconnect, the InfiniBand Host Channel Adapter (HCA) in each node must be configured before it can be used.

This section describes how to set up the InfiniBand service on the nodes for regular use. Setting up InfiniBand for booting and provisioning purposes is described in Chapter [5](/admin/provisioning), while setting up InfiniBand for NFS is described in section [3.13.4](#3134-configuring-nfs-volume-exports-and-mounts-over-rdma-with-ofed-drivers).

### 3.6.1  Installing Software Packages

On a standard NVIDIA Base Command Manager cluster, the OFED (OpenFabrics Enterprise Distribution) packages that are part of the Linux base distribution are used. These packages provide RDMA implementations allowing high bandwidth/low latency interconnects on OFED hardware. The implementations can be used by InfiniBand hardware.

By default, all relevant OFED packages are installed on the head node and software images. It is possible to replace the distribution OFED with an OFED provided by the BCM repository or another custom version. The replacement can be for the entire cluster, or only for certain software images. Administrators may choose to switch to a different OFED version if the HCAs used are not supported by the distribution OFED version, or to increase performance by using an OFED version that has been optimized for a particular HCA. Installing a BCM OFED package is covered in [Chapter 10](/installation/nvidiamlnxofed) of the *Installation Manual*.

If the InfiniBand network is enabled during cluster installation, then the `infiniband.conf` and `rdma.conf` modules in the subdirectory `etc/rdma/modules/` are automatically configured for the detected hardware.

The relevant InfiniBand HCA kernel modules are then automatically loaded during the init stage by systemd. Verifying that InfiniBand is active can be done after the cluster is up and running by running `ibstat`:

```bash
auser@head:~$ ibstat
CA 'mlx5_0'
        CA type: MT4123
        Number of ports: 1
        Firmware version: 20.31.2006
        Hardware version: 0
        Node GUID: 0xb8599f0300e4222a
        System image GUID: 0xb
        Port 1:
                State: Active
                Physical state: LinkUp
...
```

### 3.6.2  Subnet Managers

Every InfiniBand subnet requires at least one subnet manager to be running. The subnet manager takes care of routing, addressing and initialization on the InfiniBand fabric. Some InfiniBand switches include subnet managers. However, on large InfiniBand networks or in the absence of a switch-hosted subnet manager, a subnet manager needs to be started on at least one node inside of the cluster. When multiple subnet managers are started on the same InfiniBand subnet, one instance will become the active subnet manager whereas the other instances will remain in passive mode. It is recommended to run 2 subnet managers on all InfiniBand subnets to provide redundancy in case of failure.

On a Linux machine that is not running BCM, an administrator sets a subnet manager service (usually `opensm`, but `opensmd` in SLES) to start at boot-time with a command such as:

`systemctl enable opensm.service`

However, for clusters managed by BCM, a subnet manager is best set up using CMDaemon. There are two ways of setting CMDaemon to start up the subnet manager on a node at boot time:

1. by assigning a role.

   In `cmsh` this can be done with:

   ```bash
   [root@basecm10 ~]# cmsh -c "device roles <node>; assign subnetmanager; commit"
   ```

   where `<node>` is the name of a node on which it will run, for example: `basecm10`, `node001`, `node002`...

   In Base View, the subnet manager role is assigned by selecting a head node or regular node from the `Devices` resource, and assigning it the “`Subnet manager role`”. The navigation path for this, for a node `node002` for example, is `Devices` > `Nodesnode002` > `Settings` > `Roles` > `Add[Subnet manager role]`.

2. by setting the service up. Services are covered more generally in section [3.14](#314-managing-and-configuring-services).

   In `cmsh` this is done with:

   **Example**

   ```bash
   [root@basecm10 ~]# cmsh
   [basecm10]% device services node001
   [basecm10->device[node001]->services]% add opensm
   [basecm10->device[node001]->services*[opensm*]]% set autostart yes
   [basecm10->device[node001]->services*[opensm*]]% set monitored yes
   [basecm10->device[node001]->services*[opensm*]]% commit
   [basecm10->device[node001]->services[opensm]]%
   ```

   In Base View the subnet manager service is configured by selecting a head node or regular node from the resources tree, and adding the service to it. The navigation path for this, for a node `node002` for example, is: `Devices` > `Nodesnode002` > `Settings` > `Services`\[*Service*].

When the head node in a cluster is equipped with an InfiniBand HCA, it is a good candidate to run as a subnet manager for smaller clusters.

On large clusters a dedicated node is recommended to run the subnet manager.

### 3.6.3  InfiniBand Network Settings

Although not strictly necessary, it is recommended that InfiniBand interfaces are assigned an IP address (i.e. IP over IB). First, a network object in the cluster management infrastructure should be created. The procedure for adding a network is described in section [3.2.2](#322-adding-networks). The following settings are recommended as defaults:

<table>
  <colgroup>
    <col />

    <col />
  </colgroup>

  <thead>
    <tr>
      <th>
        **Property**
      </th>

      <th>
        **Value**
      </th>
    </tr>
  </thead>

  <tbody>
    <tr>
      <td>
        `Name`
      </td>

      <td>
        `ibnet`
      </td>
    </tr>

    <tr>
      <td>
        `Domain name`
      </td>

      <td>
        `ib.cluster`
      </td>
    </tr>

    <tr>
      <td>
        `Type`
      </td>

      <td>
        `internal`
      </td>
    </tr>

    <tr>
      <td>
        `Base address`
      </td>

      <td>
        `10.149.0.0`
      </td>
    </tr>

    <tr>
      <td>
        `Netmask bits`
      </td>

      <td>
        `16`
      </td>
    </tr>

    <tr>
      <td rowspan="2">
        `MTU`
      </td>

      <td>
        up to 

        `4k`

         in datagram mode
      </td>
    </tr>

    <tr>
      <td>
        up to 

        `64k`

         in connected mode
      </td>
    </tr>
  </tbody>
</table>

By default, an InfiniBand interface is set to datagram mode, because it scales better than connected mode. It can be configured to run in connected mode by setting the `connectedmode` property:

**Example**

```bash
[basecm10->device[node001]->interfaces[ib0]]% set connectedmode yes
```

For nodes that are PXE booting or are getting provisioned over InfiniBand, the mode setting in the node-installer script has to be changed accordingly.

**Example**

```bash
[root@basecm10 ~]# echo datagram > /cm/node-installer/scripts/ipoib_mode
```

Once the network has been created all nodes must be assigned an InfiniBand interface on this network. The easiest method of doing this is to create the interface for one node device and then to clone that device several times.

For large clusters, a labor-saving way to do this is using the `addinterface` command (section [3.7.1](#371-bmc-network-settings)) as follows:

```bash
[root@basecm10 ~]# echo "device
addinterface -n node001..node150 physical ib0 ibnet 10.149.0.1
commit" | cmsh -x
```

When the head node is also equipped with an InfiniBand HCA, it is important that a corresponding interface is added and configured in the cluster management infrastructure.

**Example**

Assigning an IP address on the InfiniBand network to the head node:

```bash
[basecm10->device[basecm10]->interfaces]% add physical ib0
[basecm10->device[basecm10]->interfaces*[ib0*]]% set network ibnet
[basecm10->device[basecm10]->interfaces*[ib0*]]% set ip 10.149.255.254
[basecm10->device[basecm10]->interfaces*[ib0*]]% commit
```

As with any change to the network setup, the head node needs to be restarted to make the above change active.

### 3.6.4  Verifying Connectivity

After all nodes have been restarted, the easiest way to verify connectivity is to use the `ping` utility

**Example**

Pinging node015 while logged in to node014 through the InfiniBand interconnect:

```bash
[root@node014 ~]# ping node015.ib.cluster
PING node015.ib.cluster (10.149.0.15) 56(84) bytes of data.
64 bytes from node015.ib.cluster (10.149.0.15): icmp_seq=1 ttl=64
time=0.086 ms
...
```

If the ping utility reports that ping replies are being received, the InfiniBand is operational. The `ping` utility is not intended to benchmark high speed interconnects. For this reason it is usually a good idea to perform more elaborate testing to verify that bandwidth and latency are within the expected range.

The quickest way to stress-test the InfiniBand interconnect is to use the Intel MPI Benchmark (IMB), which is installed by default in `/cm/shared/apps/imb/current`. The `setup.sh` script in this directory can be used to create a template in a user’s home directory to start a run.

**Example**

Running the Intel MPI Benchmark using `openmpi` to evaluate performance of the InfiniBand interconnect between `node001` and `node002`:

```bash
[root@basecm10 ~]# su - cmsupport
[cmsupport@basecm10 ~]$ cd /cm/shared/apps/imb/current/
[cmsupport@basecm10 current]$ ./setup.sh
[cmsupport@basecm10 current]$ cd ~/BenchMarks/imb/2017
[cmsupport@basecm10 2017]$ module load openmpi/gcc
[cmsupport@basecm10 2017]$ module initadd openmpi/gcc
[cmsupport@basecm10 2017]$ make -f make_mpi2
[cmsupport@basecm10 2017]$ mpirun -np 2 -machinefile ../nodes IMB-MPI1 PingPong
#---------------------------------------------------
# Benchmarking PingPong
# #processes = 2
#---------------------------------------------------
       #bytes #repetitions      t[usec]   Mbytes/sec
            0         1000         0.78         0.00
            1         1000         1.08         0.88
            2         1000         1.07         1.78
            4         1000         1.08         3.53
            8         1000         1.08         7.06
           16         1000         1.16        13.16
           32         1000         1.17        26.15
           64         1000         1.17        52.12
          128         1000         1.20       101.39
          256         1000         1.37       177.62
          512         1000         1.69       288.67
         1024         1000         2.30       425.34
         2048         1000         3.46       564.73
         4096         1000         7.37       530.30
         8192         1000        11.21       697.20
        16384         1000        21.63       722.24
        32768         1000        42.19       740.72
        65536          640        70.09       891.69
       131072          320       125.46       996.35
       262144          160       238.04      1050.25
       524288           80       500.76       998.48
      1048576           40      1065.28       938.72
      2097152           20      2033.13       983.71
      4194304           10      3887.00      1029.07

# All processes entering MPI_Finalize
```

To run on nodes other than `node001` and `node002`, the `../nodes` file must be modified to contain different hostnames. To perform other benchmarks, the `PingPong` argument should be omitted.

## 3.7  Configuring BMC (IPMI/iLO/DRAC/CIMC/Redfish) Interfaces

BCM can initialize and configure the baseboard management controller (BMC) that may be present on devices. This ability can be set during the installation on the head node ([figure 3.15 of the *Installation Manual*](/installation/installing#fig-mi-bmcconfiguration)), or it can be set after installation as described in this section. The IPMI, iLO, DRAC, CIMC, or Redfish interface that is exposed by a BMC is treated in the cluster management infrastructure as a special type of network interface belonging to a device. In the most common setup a dedicated network (i.e. IP subnet) is created for BMC communication. The `10.148.0.0/16` network is used by default for BMC interfaces by BCM.

### 3.7.1  BMC Network Settings

The first step in setting up a BMC is to add the BMC network as a network object in the cluster management infrastructure. The procedure for adding a network is described in section [3.2.2](#322-adding-networks). The following settings are recommended as defaults:

<table>
  <colgroup>
    <col />

    <col />
  </colgroup>

  <thead>
    <tr>
      <th>
        **Property**
      </th>

      <th>
        **Value**
      </th>
    </tr>
  </thead>

  <tbody>
    <tr>
      <td>
        `Name`
      </td>

      <td>
        `bmcnet`

        , 

        `ilonet`

        , 

        `ipminet`

        , 

        `dracnet`

        , 

        `cimcnet`

        , or 

        `rfnet`
      </td>
    </tr>

    <tr>
      <td>
        `Domain name`
      </td>

      <td>
        `bmc.cluster`

        , 

        `ilo.cluster`

        , 

        `ipmi.cluster`

        , 

        `drac.cluster`

        , 

        `cimc.cluster`

        , or 

        `rf.cluster`
      </td>
    </tr>

    <tr>
      <td>
        `Type `
      </td>

      <td>
        `Internal`
      </td>
    </tr>

    <tr>
      <td>
        `Base address`
      </td>

      <td>
        `10.148.0.0`
      </td>
    </tr>

    <tr>
      <td>
        `Netmask bits`
      </td>

      <td>
        `16`
      </td>
    </tr>

    <tr>
      <td>
        `Broadcast address`
      </td>

      <td>
        `10.148.255.255`
      </td>
    </tr>
  </tbody>
</table>

Once the network has been created, all nodes must be assigned a BMC interface, of type `bmc`, on this network. The easiest method of doing this is to create the interface for one node device and then to clone that device several times.

For larger clusters this can be laborious, and a simple `bash` loop can be used to do the job instead:

```bash
[basecm10 ~]# for ((i=1; i<=150; i++)) do
echo "
device interfaces node$(printf '%03d' $i)
add bmc ipmi0
set network bmcnet
set ip 10.148.0.$i
commit"; done | cmsh -x     # -x usefully echoes what is piped into cmsh
```

The preceding loop can conveniently be replaced with the `addinterface` command, run from within the `device` mode of `cmsh`:

```bash
[basecm10 ~]# echo "
device
addinterface -n node001..node150 bmc ipmi0 bmcnet 10.148.0.1
commit" | cmsh -x
```

The `help` text in `cmsh` gives more details on how to use `addinterface`.

Most administrators are likely to simply run it as an interactive session in `cmsh`, running the `help addinterface` command for reference, and then supplying the options for the nodes and interface settings in `device` mode. For example, as in the following session:

```bash
[root@basecm10 ~]# cmsh
[basecm10]% device
[basecm10->device]% help addinterface
Name:
          addinterface - Add a network interface to one or more nodes

Usage:
          addinterface [OPTIONS] <type> <devicename> <network> <firstip>

Options:
...help text omitted...
Examples:
          addinterface -n node001..node010 physical ib0 ibnet 10.149.0.1

[basecm10->device]% addinterface -n node001..node150 bmc ipmi0 bmcnet 10.148.0.1
[basecm10->device*]% commit
```

In order to be able to communicate with the BMC interfaces, the head node also needs an interface on the BMC network. Depending on how the BMC interfaces are physically connected to the head node, the head node has to be assigned an IP address on the BMC network one way or another. There are two possibilities for how the BMC interface is physically connected:

* When the BMC interface is connected to the primary internal network, the head node should be assigned an alias interface configured with an IP address on the BMC network.

* When the BMC interface is connected to a dedicated physical network, the head node must also be physically connected to this network. A physical interface must be added and configured with an IP address on the BMC network.

**Example**

Assigning an IP address on the BMC network to the head node using an alias interface:

```bash
[basecm10->device[basecm10]->interfaces]% add alias eth0:0
[basecm10->device[basecm10]->interfaces*[eth0:0*]]% set network bmcnet
[basecm10->device[basecm10]->interfaces*[eth0:0*]]% set ip 10.148.255.254
[basecm10->device[basecm10]->interfaces*[eth0:0*]]% commit
[basecm10->device[basecm10]->interfaces[eth0:0]]%
Mon Dec 6 05:45:05 basecm10: Reboot required: Interfaces have been modified
[basecm10->device[basecm10]->interfaces[eth0:0]]% ..;..
[basecm10->device[basecm10]]% reboot
```

As with any change to the network setup, the head node needs to be restarted to make the above change active.

BMC connectivity from the head node to the IP addresses of the configured interfaces on the regular nodes can be tested with Bash one-liner such as:

**Example**

```bash
[root@basecm10 ~]# for i in $(cmsh -c "device; foreach -t physicalnode (interfaces; \
use ilo0; get ip)"); do ping -c1 $i; done | grep -B1 packet
--- 10.148.0.1 ping statistics ---
1 packets transmitted, 0 received, 100% packet loss, time 0ms
--- 10.148.0.2 ping statistics ---
1 packets transmitted, 0 received, 100% packet loss, time 0ms
--- 10.148.0.3 ping statistics ---
1 packets transmitted, 0 received, 100% packet loss, time 0ms
...
```

In the preceding example the packet loss demonstrates there is a connection problem between the head node and the BMC subnet.

### 3.7.2  BMC Authentication

The node-installer described in Chapter [5](/admin/provisioning) is responsible for the initialization and configuration of the BMC interface of a device. In addition to a number of network-related settings, the node-installer also configures BMC authentication credentials. By default BMC interfaces are configured with username `bright` and a random password that is generated during the installation of the head node. The password is stored by CMDaemon. It can be managed from `cmsh` from within the `base` object of `partition` mode, in the `bmcsettings` submode. This means that by default, each BMC in the cluster has that username and password set during node boot.

For example, the current values of the BMC username and password for the entire cluster can be obtained and changed as follows:

**Example**

```bash
[basecm10]% partition use base
[basecm10->partition[base]]% bmcsettings
[basecm10->partition[base]->bmcsettings]% get username
bright
[basecm10->partition[base]->bmcsettings]% get password
Za4ohni1ohMa2zew
[basecm10->partition[base]->bmcsettings]% set username bmcadmin
[basecm10->partition*[base*]->bmcsettings*]% set password
enter new password: ******
retype new password: ******
[basecm10->partition*[base*]->bmcsettings*]% commit
```

In Base View, selecting the cluster item in the resources pane, and then using the `Settings` option, allows the BMC settings to be edited.

The BMC authentication credentials, and also some other BMC properties can be set cluster-wide, category, or per node. As usual, category settings override cluster-wide settings, and node settings override category settings. The relevant properties are:

<table>
  <colgroup>
    <col />

    <col />
  </colgroup>

  <thead>
    <tr>
      <th>
        **Property**
      </th>

      <th>
        **Description**
      </th>
    </tr>
  </thead>

  <tbody>
    <tr>
      <td>
        `BMC User ID`
      </td>

      <td>
        User type. Normally set to 

        `4`

         for administrator access.
      </td>
    </tr>

    <tr>
      <td>
        `BMC User Name`
      </td>

      <td>
        User name used when sending a BMC command
      </td>
    </tr>

    <tr>
      <td>
        `BMC Password`
      </td>

      <td>
        Password for specified user name when sending a BMC command
      </td>
    </tr>

    <tr>
      <td>
        `BMC Power reset delay`
      </td>

      <td>
        Delay, in seconds, before powering up (default value: 

        `0`

        )
      </td>
    </tr>

    <tr>
      <td>
        `BMC extra arguments`
      </td>

      <td>
        Extra arguments passed to BMC commands
      </td>
    </tr>

    <tr>
      <td>
        `BMC privilege`
      </td>

      <td>
        Possible options are 

        \


        • administrator

        \


        • callback

        \


        • OEMproprietary

        \


        • operator

        \


        • user
      </td>
    </tr>
  </tbody>
</table>

BMC configuration on a head node is done directly.

For regular nodes BCM stores the BMC configuration, and uses it:

* to configure the BMC interface from the node-installer

* to authenticate to the BMC interface after it has come up

BMC management operations, such as power cycling nodes and collecting hardware metrics, can then be performed after the node has been provisioned again.

If BMC authentication fails, then an explanation for why can often be found in the node-installer log at `/var/log/node-installer`.

### 3.7.3  Interfaces Settings

#### 3.7.3.1  Interface Name

It is recommended that the network device name of a BMC interface start with `ipmi`, `ilo`, `drac`, `cimc`, or `rf`, according to whether the BMC is running with IPMI, iLO, DRAC, CIMC, or Redfish. Numbers are appended to the base name, resulting in, for example: `ipmi0`.

#### 3.7.3.2  Obtaining The IP address

BMC interfaces can have their IP addresses configured statically, or obtained from a DHCP server.

Only a node with a static BMC IP address has BMC power management done by BCM. If the node has a DHCP-assigned BMC IP address, then it requires custom BMC power management (section [4.1.4](/admin/power#414-custom-power-control)) due to its dynamic nature.

#### 3.7.3.3  Dell OpenManage And `racadm` Installation

The Dell OpenManage utilities are provided with BCM only for RHEL8-based distributions at the time of writing of this section (September 2023).

If Dell was chosen as the hardware vendor when the BCM ISO was created for installation, and chosen as the hardware manufacturer when the head node was configured in the BCM installer ([section 3.3.10 of the *Installation Manual*](/installation/installing#3310-head-node-settings)), then the Dell OpenManage utilities are located under `/opt/dell` on the head node.

If Dell was chosen as the hardware manufacturer when nodes are configured in the BCM installer ([section 3.3.11 of the *Installation Manual*](/installation/installing#3311-compute-nodes-settings)), then the default software image that is used by the node has the Dell OpenManage utilities, located on the head node at `/cm/images/default-image/opt/dell`.

The Dell OpenManage utilities contain the `racadm` binary to carry out remote access control administration. The `racadm` tool can be used to issue power commands (Chapter [4](/admin/power)). BCM runs commands similar to the following to issue the power commands:

```bash
/opt/dell/srvadmin/sbin/racadm -r <DRAC interface IP address> -u <bmcusername> -p <bmcpassword>\
 serveraction powerstatus
/opt/dell/srvadmin/sbin/racadm -r <DRAC interface IP address> -u <bmcusername> -p <bmcpassword>\
 serveraction hardreset
```

The BMC username/password values can be obtained from `cmsh` as follows:

```bash
[root@basecm10 ~]# cmsh
[basecm10]% partition use base
[basecm10->partition[base]]% bmcsettings
[basecm10->partition[base]->bmcsettings]% get password
12345
[basecm10->partition[base]->bmcsettings]% get username
tom
[basecm10->partition[base]->bmcsettings]%
```

Sometimes the `bright` user does not have the right privilege to get the correct values. The `racadm` commands then fail.

The `bright` user privilege can be raised using the following command:

```bash
/opt/dell/srvadmin/sbin/racadm -r <DRAC interface IP address> -u root -p <root password> set \
iDRAC.Users.4.Privilege 511
```

Here it is assumed that the BMC user has the username `bright`, a userID `4`, and the privilege can be set to `511`.

### 3.7.4  Identification With A BMC

Sometimes it is useful to identify a node using BMC commands. This can be done by, for example, blinking a light via a BMC command on the node:

**Example**

```bash
ipmitool -U <bmcusername> -P <bmcpassword> -H <host IP> chassis identify 1
```

The exact implementation may be vendor-dependent, and need not be an `ipmitool` command. Such commands can be scripted and run from CMDaemon.

The `ipmitool` command is provided by loading the `ipmitool` modules environment. The modules environment (section [2.2](/admin/clustermanagement#22-modules-environment)) is provided by the `cm-ipmitool` and the `cm-freeipmi` packages.

For testing without a BMC, the example script at `/cm/local/examples/cmd/bmc_identify` can be used if the environment variable `$CMD_HOSTNAME` is set. The logical structure of the script can be used as a basis for carrying out an identification task when a physical BMC is in place, by customizing the script and then placing the script in a directory for use.

To have such a custom BMC script run from CMDaemon, [the `BMCIdentifyScript` advanced configuration directive](/admin/cmdconf#c60-bmcidentifyscript-directive) ([here](/admin/cmdconf#c60-bmcidentifyscript-directive)) can be used.

The `ipmitool` command can also be used for troubleshooting during provisoning ([here](/admin/provisioning#588-node-installer-cannot-start-bmc-ipmiilo-interface)).

## 3.8  Configuring BlueField DPUs

NVIDIA BlueField Data Processing Units (DPUs) are an `aarch64`-based compute platform for cluster infrastructure.

A DPU is a programmable network card with in-network compute, acceleration, isolation, storage, and security capabilities.

Organizations can use DPUs to build software-defined, hardware-accelerated IT infrastructure.

The configuration of DPUs with BCM is done using the `cm-dpu-setup` utility. This creates DPU entities in BCM, installs the DOCA ([https://docs.nvidia.com/doca/sdk/overview/index.html](https://docs.nvidia.com/doca/sdk/overview/index.html)) software stack on host nodes, creates a specialized software image for the DPUs, and provisions them to boot over the network.

### 3.8.1  Assumptions And Limitations

DPU provisioning with BCM assumes that DPUs and their host nodes have a strict 1-to-1 relation. This means that for all host nodes with DPUs, a single host only ever has a single DPU.

At the time of writing of this section, (April 2023) the `cm-dpu-setup` utility supports provisioning using the 1.5.1 LTS version of the DPU software stack. Version 2.0 is due soon, but has not yet been tested with `cm-dpu-setup`.

### 3.8.2  Preparation

* Secure boot must be disabled in the DPU BIOS settings. This is required to allow the DPU to boot over PXE.

* The DPU provisioning process requires the following two additional files:

  1. a DOCA host software repository archive. For example:\
     `doca-host-repo-ubuntu2004_1.5.1-0.1.8.1.5.1007.1.5.8.1.1.2.1_amd64.deb`

  2. a BlueField Bootstream (BFB) file. For example:\
     `DOCA_1.5.1_BSP_3.9.3_Ubuntu_20.04-4.2211-LTS.signed.bfb`

  Both can be acquired from the NVIDIA developer website at [https://developer.nvidia.com/networking/doca#downloads](https://developer.nvidia.com/networking/doca#downloads). The files should be placed on the head node.

* The DPUs all need to be physically installed in their hosts before running `cm-dpu-setup`.

  1. Provisioning requires at least one performance port to be connected.

  2. There must also be an Ethernet connection with the OOB/BMC port, which is the interface over which BCM manages and PXE boots the DPU.

### 3.8.3  Installation

New DPU deployments can only be provisioned using the `cm-dpu-setup` CLI tool, and not using Base View. Configuration of the deployment should usually be done interactively, which results in a YAML configuration file. This configuration file is then used by `cm-dpu-setup` to perform all provisioning steps.

When a cluster already has a provisioned DPU deployment, `cm-dpu-setup` gives an option to extend it with new DPUs.

#### 3.8.3.1  Provisioning DPUs With `cm-dpu-setup`

Starting `cm-dpu-setup` without any arguments launches the interactive TUI for configuring a new DPU deployment (figure [3.11](#fig-cm-dpu-setup-ncurses-initial-screen)):

![Initial screen for cm-dpu-setup](/base-command-manager/product-manuals/_fern-img/910e2f5760eaedc339fb50deeffca79d870c9e776587a3d41c99175cfaf97e50.webp)

*Figure 3.11: Initial screen for cm-dpu-setup*

When `Provision` is selected, the wizard guides the user on selecting the host nodes of the DPUs. It is the DPUs that are to be provisioned within these hosts. Host nodes can be selected by choosing whole categories or individual nodes. The selected nodes are rebooted during the provisioning process.

The `cm-dpu-setup` wizard then prompts for a name for the category of all DPU nodes. The DPU image and DPU settings are assigned to this category, and the settings are thus automatically applied to all DPU nodes.

Next is a screen to configure the performance network (figure [3.12](#fig-cm-dpu-setup-ncurses-dpu-network)):

![Configuration screen for the DPU network](/base-command-manager/product-manuals/_fern-img/710672209f46f65d815dda92072619bf42b249befcfa5af01bb14fb14379d1e0.webp)

*Figure 3.12: Configuration screen for the DPU network*

This configuration creates a network and connects it to the provided interface port. The options for the port interfaces on most DPUs are P0 and P1. The exact value depends on the PCI bus numbering allocated to the DPU.

The next screen asks for the IP address offset for the management interface, relative to the host node’s assigned IP address on the internal network.

The `cm-dpu-setup` utility then prompts for names to be given for the software images that are to be created on the DPU and the host nodes. The BFB file for building the DPU image, and a DOCA archive for building an image for the host nodes, are also selected.

Finally, `cm-dpu-setup` prompts for configuration of the DPU settings object that is defined in BCM (figure [3.13](#fig-cm-dpu-setup-ncurses-dpu-settings)):

![Configuration screen for the DPU settings](/base-command-manager/product-manuals/_fern-img/6df7ba6a0b5ff1c47b829f43187f0c1e77269af73ef67fadd313e1bca74186d4.webp)

*Figure 3.13: Configuration screen for the DPU settings*

Every physical interface port of a DPU can be configured to be either Ethernet or InfiniBand, depending on its SKU. The operation mode (section [3.8.4](#384-managing-dpu-settings)) of a DPU can be set to:

* `separated_host`: treats the DPU as a separate host to the node hosting it

* `embedded_cpu`: treats the DPU as part of the node hosting it

The boot mode determines from which device the DPU boots. This does not include PXE boot, which is configured separately by `cm-dpu-setup` itself. This boot mode is relevant in cases where PXE boot fails.

The summary screen appears after the configuration steps are completed. It allows the configuration to be viewed, saved, or saved and deployed.

![Summary of the configuration](/base-command-manager/product-manuals/_fern-img/e1e8879d8c48508b65b8aebb29f5c68269dea71d2403445b987e1b516cc480ba.webp)

*Figure 3.14: Summary of the configuration*

Deployment takes some time, especially during software image creation from the BFB file. The DPU device is automatically given a name composed of the node which hosts it together with the suffix `-dpu`. Steps are displayed during the deployment process. The log file gets written at `/var/log/cm-dpu-setup.log`

#### 3.8.3.2  Extending DPU Deployment With `cm-dpu-setup`

When the cluster already contains DPU nodes, the `cm-dpu-setup` wizard provides additional menu options to extend or remove the deployment (figure [3.15](#fig-cm-dpu-setup-ncurses-initial-screen-post-deploy)):

![Initial screen for cm-dpu-setup with already existing DPU nodes](/base-command-manager/product-manuals/_fern-img/25968610f074573f3505bb9b4a83b7a6175087c4939845d7b2f4e01233ff10a3.webp)

*Figure 3.15: Initial screen for cm-dpu-setup with already existing DPU nodes*

Extending the cluster with more DPU nodes can be done with

* a new network, for example InfiniBand instead of Ethernet, or just a separate subnet

* with a new BFB base image, which creates a new DPU software image

* simply adding additional DPUs to an existing DPU category, which implies that they boot with the same image and have the same network configuration

For the first two options, `cm-dpu-setup` prompts for the configuration of a new category, so that the different subsets of DPUs in the cluster can be distinguished. All kinds of variations in configuration can thus be carried out.

#### 3.8.3.3  CLI Options For `cm-dpu-setup`

The `cm-dpu-setup` utility has the following usage instructions:

```bash
root@basecm10:~# cm-dpu-setup -h

usage: DPU cm-dpu-setup [-c <config_file>] [--remove] [--yes-i-really-mean-it] [--erase-images]
                        [--skip-network] [--skip-host-image] [--skip-archos] [--extend]
                        [--hold-bfb-packages HOLD_BFB_PACKAGES] [-v] [--store-name-aliases]
                        [--no-distro-checks] [--json] [--output-remote-execution-runner]
                        [--on-error-action debug,remotedebug,undo,abort] [--skip-packages]
                        [--min-reboot-timeout <reboot_timeout_seconds>] [--allow-running-from-secondary]
                        [--dev] [-h]

optional arguments:
  -h, --help            Print this screen

common:
  Common arguments

  -c <config_file>      Load runtime configuration for plugins from a YAML config file

Managing DPUs:
  Flags that can be used to manage DPUs in a cluster

  --remove              Remove and reset DPUs
  --yes-i-really-mean-it
                        Required for additional safety
  --erase-images        Erase all images from disk during removal
  --skip-network        Skip check and creation of DPU performance network
  --skip-host-image     Skip creation of the Host Image
  --skip-archos         Skip creation of ArchOS and continue with DPU deployment
  --extend              Extend current deployment with new DPU nodes
  --hold-bfb-packages HOLD_BFB_PACKAGES
                        Mark a custom set (comma-separated) of packages to be held for install
                        during DPU image build
```

The help output continues beyond this, but only contains advanced, generic `cm-setup` options, and not DPU-specific options.

The options can be grouped as follows:

* Common arguments:

  * `-c` \<*`YAML configuration file`*>: Loads a runtime configuration for plugins, from a YAML configuration file.

* Removal arguments:

  * `--remove`: Starts the removal process. Does not do anything unless `--yes-i-really-mean-it` is also provided.

  * `--yes-i-really-mean-it`: Required as a safety precaution when removing the DPU deployment from the CLI.

  * `--erase-images`: Also removes the software images from disk instead of only removing the entities from BCM.

* Provisioning management arguments: This group of arguments is useful when the provisioning process has been interrupted and an administrator wants to continue it without starting again from scratch.

  * `--skip-network`: Skips check for overlap with existing networks and creation of the network.

  * `--skip-host-image`: Skips the creation of the host image.

  * `--skip-archos`: Skips the creation of the DPU image, node-installer image, shared image, and the ArchOS object.

* DPU image arguments:

  * `--hold-bfb-packages` \<*`packages`*>: Comma-separated list of packages to hold off on with post-install configuration and set up a service to finish it on DPU boot. This is necessary for certain packages that fail to install inside of a chroot/systemd-spawn environment because their configuration depends on certain hardware being present or being booted with `systemd` as PID 1.

#### 3.8.3.4  Troubleshooting

Some problems that may occur during installation are described in this section, along with possible solutions. **Host or DPU image creation stage fails:**

* **A package fails to install or the software configuration fails:** If this happens, then the cluster administrator should try to establish how it failed. Did it fail because of:

  * dependencies on `systemd`? A workaround could be to pass a dependency as an argument to `--hold-bfb-packages`.

  * unsupported external hardware? The cluster administrator can check that the base BFB file used supports the hardware used (1.5.1 LTS or newer).

* **A repository is inaccessible:** If this happens, then the cluster administrator should check that the BCM repositories are reachable from the head node, and that the authentication is correct. If there are missing or invalid GPG keys, then the keys that the BFB file is shipped with should be checked. The 1.5.1 LTS version of the BFB file ships with a Kubernetes GPG key that expired in December 2022. The `cm-dpu-setup` utility automatically fetches the correct key.

**Pre-install checks are failing:**

* DPU-related entities already exist in the cluster: if a previous deployment or setup process was not cleaned up properly, then there might be leftover entities in BCM that inhibit a fresh setup. The generic entities related to a DPU deployment are as follows:

  * DPU network

  * RShim network

  * DPU category

  * DPU settings (applied to the category)

  * Host image

  * DPU image

  * Ubuntu 20.04 `aarch64` (in the base partition, under `archos` mode)

  * Ubuntu 20.04 `aarch64` node-installer image

  * Ubuntu 20.04 `aarch64` shared image

  * DPU nodes

**Rebooting nodes fails**

Possible failures when trying to reboot nodes are:

###### Mellanox configuration fails:

the DPU provisioning stage configures the DPU via the command:\
`mlxconfig -d /dev/mst/mt41686_pciconf0`\
on the host. If this stage fails, then possible reasons are:

* the DPU is not available

* it is a model that does not support Ethernet (the default config resets both ports to Ethernet during provisioning)

* the DPU appears under a different device identifier in the filesystem

In the last case, BCM support can be contacted to check on the state of updates for support on the device.

###### Timeout while waiting for DPUs to become reachable:

It may be that `cm-dpu-setup` could not establish an SSH connection from the RSHim (outside the DPU) to the `tmfifo` interface (inside the DPU). Underlying reasons for this could be:

* The PXE boot may have failed

* the interfaces on the DPU are not configured correctly.

Provisioning a base BFB file to the DPU directly with `cmsh` using

**Example**

```bash
[basecm10->device[node001-dpu]]% dpu push-bfb
```

can be tried out to confirm that the interface is healthy. If the problem persists, then BCM support can be contacted.

### 3.8.4  Managing DPU Settings

A DPU is generally managed as a node, with a custom kernel, by CMDaemon. So most of the regular node operations work with the DPU just as they do with a regular node.

This section covers DPU operations that are not managed by regular node operations in CMDaemon. A backend script, `cm-dpu-manage`, is used to carry out these operations, but it is recommended to use the `cmsh` front end for all the operations instead.

#### 3.8.4.1  DPU Discovery

At device level, DPUs can be discovered:

**Example**

```bash
[basecm10->device]% dpu discover
Node        bfb  boot_order     mac                success  version
----------- ---- -------------- ------------------ -------- -----------------------------------...
node001-dpu no   NET-OOB-IPV4   94:6d:ae:6c:89:1e  yes      bright ubuntu 22.04 Cluster Manager...
node002-dpu no   NET-OOB-IPV4   94:6d:ae:6c:88:be  yes      bright ubuntu 22.04 Cluster Manager...
```

#### 3.8.4.2  Listing And Pushing BFB Files For DPUs

All available BFB files can be listed with:

**Example**

```bash
[basecm10->device]% dpu list-bfb
DOCA_2.0.2_BSP_4.0.3_Ubuntu_22.04-10.23-04.prod.bfb
```

A specific BFP file can be provisioned to a DPU `node001-dpu` with

**Example**

```bash
[basecm10->device]% dpu push-bfb -n node001-dpu -f DOCA2.0.2_BSP_4.0.3_Ubuntu_test.bfb
```

#### 3.8.4.3  DPU Settings That Have Been Applied

The DPU settings that are active (that have been *applied*) for a particular DPU can be viewed with:

**Example**

```bash
[basecm10->device]% dpu show -n node001-dpu
Node         boot_mode   boot_timeout  display_level  drop_mode operation_mode   Result  Error
------------ ----------- ------------- -------------- --------- ---------------- ------  -----
node001-dpu  EMMC        100           BASIC          NORMAL    EMBEDDED_CPU(1)  good
```

#### 3.8.4.4  DPU Settings Submode

DPU settings can be managed with `cmsh` from within the `dpusettings` submode. This submode is accessible from within the `partition` and `category` modes. The submode can also be accessed from within `device` mode, if the device is a DPU.

For example, for a DPU category given the name `dpu` during a `cm-dpu-setup` run, the submode settings might look like:

**Example**

```bash
basecm10->category[dpus]->dpusettings]% show
Parameter                        Value
-------------------------------- ------------------------------------------------
Revision
Operation mode                   embedded
Display level                    basic
Boot mode                        emmc
Drop mode                        normal
Boot timeout                     1m 40s
Boot order                       NET-OOB-IPV4
Interface mode port 1            eth
Interface mode port 2            ib
Offload OVS to hardware          yes
Key value settings               <submode>
```

If a setting is changed within the `dpusettings` submode, then the value becomes active on the DPU only after committing it, and then running the `dpu apply` command.

**The `dpu apply` command:** makes committed DPU settings active on the DPU.

**Example**

```bash
root@basecm10:~# cmsh
[basecm10]% device use node001-dpu
[basecm10->device[node001-dpu]]% dpusettings
[basecm10->device[node001-dpu]->dpusettings]% get displaylevel
advanced
[basecm10->device[node001-dpu]]% !ssh node001 grep DISPLAY /dev/rshim0/misc
DISPLAY_LEVEL   1 (0:basic, 1:advanced, 2:log)
[basecm10->device[node001-dpu]->dpusettings]% set displaylevel <tab><tab>
advanced  basic     log
[basecm10->device[node001-dpu]->dpusettings]% set displaylevel basic
[basecm10->device*[node001-dpu*]->dpusettings*]% commit
[basecm10->device[node001-dpu]->dpusettings]% exit
[basecm10->device[node001-dpu]]% dpu apply
[basecm10->device[node001-dpu]]% !ssh node001 grep DISPLAY /dev/rshim0/misc
DISPLAY_LEVEL   0 (0:basic, 1:advanced, 2:log)
```

Within the `dpusettings` submode:

* The `displaylevel` setting can take a value of

  * `basic`

  * `advanced`, or

  * `log`.

  The value configures the verbosity of the `/dev/rshim0/misc` file of the `rshim0` device. An `rshim` device is a network interface between the host and a DPU.

* An `Offload OVS to hardware` value of `yes` allows Open vSwitch to offload tasks to the hardware running on the interface, reducing CPU load.

* The value of `operationmode` can be:

  * `embedded`: ECPF (Embedded CPU Physical Function) mode lets the embedded ARM system of the DPU control the NIC resources and data path of the host as well as of the DPU.

  * `separated`: separated host mode lets the host and the DPU control their own resources, but has them sharing the same NIC.

  Further details on the operation mode can be found in the DOCA SDK documentation at [https://docs.nvidia.com/doca/sdk/installation-guide-for-linux/index.html#configuring-operation-mode](https://docs.nvidia.com/doca/sdk/installation-guide-for-linux/index.html#configuring-operation-mode).

* The `boot order` configures the UEFI order from which device the DPU boots. Options are:

  * `DISK`: boots from an EMMC device

  * `UEFI_SHELL`: boots into a UEFI shell

  * `NET-OOB-IPV4`: boots via PXE over an OOB interface running IPv4

  Options can also be combined using comma-separation, and the boot order then follows that comma-separated order. The boot order gets written with a `dpu apply` to a BlueField configuration file `/etc/bf.cfg` on the DPU. The value `DISK,NET-OOB-IPV4` thus results in a `bf.cfg` file:

  ```bash
  BOOT0=DISK
  BOOT1=NET-OOB-IPV4
  ```

  which results in disk booting being tried first, then PXE booting.

* The `keyvaluesettings` are existing key/value settings that can be committed from the `mlxconfig` script ([https://docs.nvidia.com/networking/display/MFT4170/Examples+of+mlxconfig+Usage](https://docs.nvidia.com/networking/display/MFT4170/Examples+of+mlxconfig+Usage)).

  The settings can alternatively be user-defined for the DPU in `cmsh` and committed from there.

  For example, the `mlnxconfig` script can be run directly on the DPU host, `node001` as follows:

  **Example**

  ```bash
  node001# mlxconfig -d <device-id> set PCI_DOWNSTREAM_PORT_OWNER[4]=0xF
  ```

  The `cmsh` equivalent for the DPU is:

  **Example**

  ```bash
  [basecm10->device[node001-dpu]->dpusettings]% keyvaluesettings
  [basecm10->device*[node001-dpu*]->dpusettings*->keyvaluesettings*]% set PCI_DOWNSTREAM_PORT_OWNER[4] 0xF
  [basecm10->device*[node001-dpu*]->dpusettings*->keyvaluesettings*]% commit
  [basecm10->device[node001-dpu]->dpusettings->keyvaluesettings]% show
  Parameter                        Value
  -------------------------------- --------------------------------
  PCI_DOWNSTREAM_PORT_OWNER[4]     0xF
  ```

#### 3.8.4.5  DPU Interfaces And IP Addresss Persistence When Operation Mode Changes

The IP address, network, and network device settings of the DPU and host can be seen as usual within the `interfaces` mode. For a node `node001`, that hosts a DPU `node001-dpu`, the interfaces list would show an output similar to:

**Example**

```bash
[basecm10->device[node001]->interfaces]% list
Type         Network device name  IP               Network          Start if
------------ -------------------- ---------------- ---------------- --------
physical     BOOTIF [prov]        10.141.0.1       internalnet      always
physical     DPU1                 10.147.0.1       netdpu1          always
physical     tmfifo_net0          192.168.100.1    tmfifonet        always
[basecm10->device[node001]->interfaces]% device use node001-dpu
[basecm10->device[node001-dpu]->interfaces]% list
Type         Network device name  IP               Network          Start if
------------ -------------------- ---------------- ---------------- --------
physical     BOOTIF [prov]        10.141.0.101     internalnet      always
physical     p1                   10.147.0.1       netdpu1          always
physical     tmfifo_net0          192.168.100.2    tmfifonet        always
```

In the example, looking at the performance embedded network `netdpu1`, the device DPU1 on the host node `node001` and the device `p1` on the DPU `node001-dpu`, have the same IP address. This is to avoid interfaces reconfiguration when the DPU is switched between embedded and separated mode.

## 3.9  Configuring Switches And PDUs

### 3.9.1  Configuring With The Manufacturer’s Configuration Interface

Network switches and PDUs that are to be used as part of the cluster should be configured with the PDU/switch configuration interface described in the PDU/switch documentation supplied by the manufacturer. Typically the interface is accessed by connecting via a web browser or telnet to an IP address preset by the manufacturer.

The IP address settings of the PDU/switch must match the settings of the device as stored by the cluster manager.

* In Base View, this is done via the navigation path `Devices` > `Edit` > \<*switchname*> to select the switch. If the switch does not already exist, then it can be added via the `ADD` button. The values in the associated `Settings` window that comes up (figure [3.16](#fig-bright-view-configuringswitchesuplinks)) can then be filled in, and the IP address can be set and saved.

* In `cmsh` this can be done in `device` mode, with a `set` command:

  **Example**

  ```bash
  [root@basecm10 ~]# cmsh
  [basecm10]% device
  [basecm10->device]% set switch01 ip 10.141.253.2
  [basecm10->device*]% commit
  ```

#### 3.9.1.1  Port Assignments For Switches

* Using the `uplinks` option to configure uplink ports is described in section [3.10.3](#3103-uplink-ports).

* The `showport` tool for seeing what MAC address matches what port number on a switch is described in section [3.10.4](#3104-the-showport-mac-address-to-port-matching-tool).

* The `switchoverview` tool gives an overview of the MAC addresses detected on the ports based on SNMP queries, and is described in section [3.10.6](#3106-the-switchoverview-command).

* The `switchports` command lists the switches and switch ports that have been assigned a node.

* The `switchports` option assigns ports on a switch to a node:

  **Example**

  ```bash
  [basecm10->device]% #the option:
  [basecm10->device]% set node003 switchports switch01:1
  [basecm10->device*]% commit
  [basecm10->device]% #the command:
  [basecm10->device*]% switchports
  Switch           #Port  Node
  ---------------- ------ ----------------
  switch01         1      node003
  ```

  The `switchports` option used at node level is a legacy option, which can still be used in BCM version 10. However it may not work as expected when a node has multiple interfaces that may be connected to a switch.

  Since BCM version 10 it is therefore recommended to assign ports from within the `interfaces` submode for a node. This assigns ports clearly per interface, and supports bonding of the interfaces (section [3.5](#35-configuring-bonded-interfaces)). Management of ports at `interface` level also makes it possible for CMDaemon Lite (section [2.6.7](/admin/clustermanagement#267-cmdaemon-lite)) to manage the network configuration of Cumulus switches (section [3.10](#310-configuring-cumulus-switches)).

  **Example**

  ```bash
  [basecm10->device]% use node003; interfaces
  [basecm10->device[node003]->interfaces]% set eth1 switchports switch01:2
  [basecm10->device*[node003*]->interfaces*]% set eth2 switchports switch01:3
  [basecm10->device*[node003*]->interfaces*]% commit; ..
  [basecm10->device[node003]]% switchports
  Switch           #Port  Node
  ---------------- ------ ----------------
  switch01         1      node003
  switch01         2      node003
  switch01         3      node003
  ```

Managing PDUs in Base View or `cmsh` is done in a similar way to the preceding method for switches. However, assigning PDUs and PDU ports to devices such as nodes is not part of this method, and is instead described in section [4.1.1](/admin/power#411-pdu-based-power-control).

#### 3.9.1.2  APC PDUs

For the APC brand of PDUs, the `powercontrol` value for the PDU device should be set to `apc`.

For example, for a PDU with the name `mypdu`, its value can be set in `cmsh` with:

**Example**

```bash
[basecm10->device[mypdu]]% set powercontrol apc; commit
```

and in Base View with the navigation path:

`Devices` > `Power Distribution Units` > `Power Distribution Unit list` > `Power Distribution Unit` > `Power control`

If it is not set to `apc`, then the list of PDU ports is ignored by default.

### 3.9.2  Configuring SNMP

BCM can be used to manage switches, including many InfiniBand switches, using SNMP. This requires that SNMP be enabled. If `disablesnmp` is set to `no`, the default, then SNMP is enabled for the switch:

**Example**

```bash
[basecm10]% device add switch myibswitch
[basecm10->device[myibswitch]]% get disablesnmp
no
```

#### 3.9.2.1  Configuring SNMP Community Strings

In order to allow the cluster management software to communicate with the switch or PDU, SNMP must be enabled on it, and the SNMP community strings should be configured correctly.

By default, the SNMP community strings for switches and PDUs are set to `public` and `private` for respectively read and write access. If different SNMP community strings have been configured in the switch or PDU, the `readstring` and `writestring` properties of the corresponding switch device should be changed.

**Example**

```bash
[basecm10]% device use switch01
[basecm10->device[switch01]]% snmpsettings
[basecm10->device[switch01]->snmpsettings]% get readstring
public
[basecm10->device[switch01]->snmpsettings]% get writestring
private
[basecm10->device[switch01]->snmpsettings]% set readstring public2
[basecm10->device*[switch01*]->snmpsettings*]% set writestring private2
[basecm10->device*[switch01*]->snmpsettings*]% commit
```

Alternatively, these properties can also be set in Base View via the navigation path:

`Devices` > `Switches` > `Edit` > `SNMP Settings`

#### 3.9.2.2  Configuring SNMP Settings

SNMP settings can be configured in `cmsh` via the `snmpsettings` submode, which is available under `partition` mode as well as under `device` mode.

The submode allows the version to be set to `v1`, `v2c`, or `v3`.

Setting the version to the value `file` is also an option, but is not meant as an option for end users. It is used in SNMP walk emulation for debugging non-standard switches.

The SNMPv3 settings that can be managed in BCM are:

**Example**

```bash
[basecm10]% device use switch01
[basecm10->device[switch01]]% snmpsettings
[basecm10->device[switch01]->snmpsettings]% show
Parameter                        Value
-------------------------------- ------------------------------------------------
Authentication key               < not set >
Authentication protocol          MD5
Context
Privacy key                      < not set >
Privacy protocol                 DES
Retries                          -1
Revision
Security level                   Authentication encrypted
Security name
Timeout                          0s
VLAN Timeout                     0s
version                          V3
```

The `set` command can be used, sometimes with tab-completion, to set the SNMP switch parameters. For example, for the SNMPv3 parameters that are set to use cryptographic keys:

**Example**

```bash
[basecm10->device*[switch01*]->snmpsettings*]% set authenticationprotocol <TAB><TAB>
md5  sha
[basecm10->device*[switch01*]->snmpsettings*]% set authenticationprotocol sha
[basecm10->device*[switch01*]->snmpsettings*]% set privacyprotocol <TAB><TAB>
aes  des
[basecm10->device*[switch01*]->snmpsettings*]% set privacyprotocol aes
[basecm10->device*[switch01*]->snmpsettings*]% commit
[basecm10->device[switch01]->snmpsettings]%
```

#### 3.9.2.3  SNMP Traps

BCM can assign an SNMP trap manager role to a node. The `snmptrapd` daemon is then configured and managed on the assigned node by CMDaemon.

Configuration options include enabling or disabling mailing of the messages, and setting the sender and recipients for the mail. By default an undefined value for `Server` means that the SNMP server is `localhost`.

**Example**

```bash
[root@basecm10 ~]# cmsh
[basecm10]% device use node001
[basecm10->device[node001]]% roles
[basecm10->device[node001]->roles]% assign snmptrap
[basecm10->device[node001]->roles*[snmptrap*]]% show
Parameter                        Value
-------------------------------- ------------------------------------------------
Name                             snmptrap
Revision
Type                             SnmpTrapRole
Add services                     yes
Event                            yes
Mail                             yes
Recipients
All administrators               no
Access                           public
Server
Sender
Arguments
Alternative script
```

## 3.10  Configuring Cumulus Switches

A Cumulus switch is a switch that runs Cumulus Linux, which is a Debian-based distribution with a networking focus.

The following capabilities and features are available, or can be run, on a switch that can run Cumulus Linux:

* ONIE (Open Network Install Environment, [https://opencomputeproject.github.io/onie/](https://opencomputeproject.github.io/onie/)): a bootloader, similar in concept to PXE booting. It allows the switch to boot up and install the Cumulus OS from an image on the network. Installing Cumulus with ONIE wipes out any existing image already installed on the switch.

* ZTP (Zero Touch Provisioning): a protocol that is used with the `ztp` client. The protocol uses specially defined DHCP options. ZTP allows the switch to automatically carry out provisioning for other hardware devices on a network on top of an OS on the switch. The capability to carry this out becomes available automatically when the switch is powered on, and the interface on which provisioning is to be carried out automatically becomes active with an IP address (“[day-0 provisioning](https://community.cisco.com/t5/nso-developer-hub-blogs/day-1-day-0-day-1-day-2-n-configurations/ba-p/3658255)”).

* [NVUE (NVIDIA User Experience)](https://docs.nvidia.com/networking-ethernet-software/cumulus-linux-54/System-Configuration/NVIDIA-User-Experience-NVUE/NVUE-CLI/): a CLI that uses the `nv` command set to manage the network configuration of the switch. The NVUE CLI is documented at [https://docs.nvidia.com/networking-ethernet-software/cumulus-linux-55/System-Configuration/NVIDIA-User-Experience-NVUE/NVUE-CLI/](https://docs.nvidia.com/networking-ethernet-software/cumulus-linux-55/System-Configuration/NVIDIA-User-Experience-NVUE/NVUE-CLI/).

* The NVUE REST API: if it is explicitly enabled, can run the same commands via HTTP as the NVUE CLI. The NVUE REST API is documented at [https://docs.nvidia.com/networking-ethernet-software/cumulus-linux-55/System-Configuration/NVIDIA-User-Experience-NVUE/NVUE-API/](https://docs.nvidia.com/networking-ethernet-software/cumulus-linux-55/System-Configuration/NVIDIA-User-Experience-NVUE/NVUE-API/)

* Public key SSH: if configured, the administrator can access the switch from the head node safely and securely with public key SSH, including passwordless SSH.

A Cumulus switch is added to the cluster manager as a regular switch object:

**Example**

```bash
[basecm10]% device add switch myswitch
[basecm10->device*[myswitch*]]% set mac 12:34:56:78:90:AB
[basecm10->device*[myswitch*]]% set ip 1.2.3.4
[basecm10->device*[myswitch*]]% set network internalnet
[basecm10->device*[myswitch*]]% # hasclientdaemon: set if CMDaemon Lite should run on switch
[basecm10->device*[myswitch*]]% set hasclientdaemon yes
[basecm10->device*[myswitch*]]% commit
[basecm10->device[myswitch]]% status
myswitch ................ [  DOWN  ]
```

Cumulus access settings (described later on, starting from [here](#31011-cumulus-switches-access-configuration)) and ZTP settings (described later on, starting from [here](#31021-custom-services-option-1-cumulus-with-cmdaemon-lite)) must also be configured for the switch to work correctly.

Committing the Cumulus switch object configuration automatically configures the DHCP and the DNS services. The DHCP server is configured by CMDaemon to use the ZTP custom provisioning script. The ZTP provisioning script is created on-demand, along with a directory, from a default template ([here](#31023-settings-applied-via-ztp)) when the switch boots. The creation can alternatively be forced right away by running the `initialize` command.

### 3.10.1  Cumulus Switches Access Configuration, Initialization And Network Device Discovery

#### 3.10.1.1  Cumulus Switches Access Configuration

By default, Cumulus switches use certificate-based authentication for CMDaemon access, just like regular nodes. DGX SuperPODS are configured in that manner.

However, CMDaemon Lite (section [2.6.7](/admin/clustermanagement#267-cmdaemon-lite)) is recommended instead of CMDaemon for Cumulus switches on most other clusters. If CMDaemon Lite is to run on the switch, then the `hasclientdaemon` parameter must be enabled for it:

**Example**

```bash
[basecm10]% device use mycumulus
[basecm10->device*[mycumulus*]]% set hasclientdaemon yes
[basecm10->device*[mycumulus*]]% commit
```

The cluster administrator must configure a username/password pair for SSH public key authentication with CMDaemon Lite.

* Since BCM version 10, Cumulus switch access via a username/password pair is configured in the `accesssettings` submode and a `force` parameter.

* In earlier versions of BCM SNMP settings were used to set the username/password pair.

**Example**

```bash
[basecm10->device]% add switch mycumulus
[basecm10->device*[mycumulus*]]% accesssettings
[basecm10->device*[mycumulus*]->accesssettings*]% set username cumulus; set password 1234; set -e force true
[basecm10->device*[mycumulus*]->accesssettings*]% show
Parameter                        Value
-------------------------------- ------------------------------------------------
force                            true
Revision
Username                         cumulus
Password                         *********
Rest port                        8765
[basecm10->device*[mycumulus*]->accesssettings*]% commit
```

If all switches are Cumulus switches, then setting the username/password can be carried out at `partition` level with:

**Example**

```bash
[basecm10->partition[base]]% accesssettings
[basecm10->partition[base]]->accesssettings]% set username cumulus; set password 1234; set -e force true
[basecm10->partition*[base*]]->accesssettings*]% commit
```

Compared with a regular node (section [6.2](/admin/usermanagement#62-managing-users-and-groups-with-cmsh)), a Cumulus switch has these differences when setting a username and password:

* The password change only takes effect on the switch after the switch reboots.

* The `force` key must be set to the value `true`, if `cm-lite-daemon` and ZTP are not installed. This lets the configuration script mechanism carry out the image change during reboot via ZTP.

The REST API port, with a default value of `8765`, can also be modified from the `accesssettings` submode, to match the deployment specifications.

Other parameters for CMDaemon Lite integration are described in the section starting [here](#31021-custom-services-option-1-cumulus-with-cmdaemon-lite), [**Custom Services Option 1: Cumulus With CMDaemon Lite**.](/admin/configuring#31021-custom-services-option-1-cumulus-with-cmdaemon-lite) Also covered in that section, [here](#31021-custom-services-option-1-cumulus-with-cmdaemon-lite), are the ZTP settings. ZTP settings are managed via the ZTP mode of `cmsh`, and are needed for the switch to pick up its ZTP provisioning script.

#### 3.10.1.2  The Cumulus Custom Discovery Script (Deprecated)

This is a legacy script that comes with BCM, and is at `/cm/local/apps/cmd/scripts/cm-cumulus-switch.py`.

Setting the script and running the `initialize` command for the Cumulus switch in `device` mode initializes access settings and carries out network discovery for the Cumulus switch, in versions of BCM prior to version 10.

Since BCM version 10, the script is only needed for the Cumulus Linux version 4 series. Since Cumulus Linux version 5, and since BCM version 10, the script is no longer required, due to the integration of Cumulus with BCM.

A Cumulus switch running version 4 of Cumulus Linux can be set up and initialized on BCM version 10 with:

**Example**

```bash
[basecm10->device*[mycumulus*]]% set controlscript /cm/local/apps/cmd/scripts/cm-cumulus-switch.py
[basecm10->device*[mycumulus*]]% commit
[basecm10->device[mycumulus]]% initialize
```

### 3.10.2  Custom Service Setups For Cumulus Linux

There are two custom service setups that are supported for cluster management on top of Cumulus Linux:

1. a setup that uses CMDaemon Lite ([here](#31021-custom-services-option-1-cumulus-with-cmdaemon-lite), **Custom Services Option 1: Cumulus With CMDaemon Lite**)

2. a setup that uses YAML to configure the services ([here](#31022-custom-services-option-2-cumulus-with-a-yaml-preconfiguration), **Custom Services Option 2: Cumulus With A YAML Preconfiguration**).

These can actually be run together, if the services do not conflict with each other. For example, the `nvued` service can be installed via YAML, to provide the NVUE, independently of CMDaemon Lite. It is however useful to describe these custom service setups individually.

#### 3.10.2.1  Custom Services Option 1: Cumulus With CMDaemon Lite

If the Cumulus switch is defined and configured with CMDaemon Lite, then this allows some Cumulus features to be managed via BCM, as well as some of the standard features of BCM to work on the switch. The following features can be managed:

* monitoring (Chapter [12](/admin/monitoring)). For example, the latest data values (section [12.6.3](/admin/monitoring#1263-the-latest-data-and-counter-valuesthe-latestdata-and-latestmetriccounters-commands)) of the switch, including the bytes going through the many ports, can be seen with:

  **Example**

  ```bash
  [basecm10->device[myswitch]]% latestmonitoringdata
  Measurable       Parameter       Type         Value         Age       State     Info
  ---------------- --------------- ------------ ------------- --------- --------- ---------
  AlertLevel       count           Internal     0             1m 5s
  AlertLevel       maximum         Internal     0             1m 5s
  AlertLevel       sum             Internal     0             1m 5s
  BufferMemory                     Memory       113 MiB       2m 5s
  BytesRecv        eth0            Network      22.3917 B/s   2m 5s
  BytesRecv        mgmt            Network      6.79167 B/s   2m 5s
  BytesRecv        mirror          Network      0 B/s         2m 5s
  BytesRecv        swid0_eth       Network      0 B/s         2m 5s
  BytesRecv        swp1            Network      0 B/s         2m 5s
  BytesRecv        swp2            Network      0 B/s         2m 5s
  BytesRecv        swp3            Network      0 B/s         2m 5s
  BytesRecv        swp4            Network      0 B/s         2m 5s
  ...
  ```

* system information can be viewed with the `sysinfo` command:

  **Example**

  ```bash
  [basecm10->device[myswitch]]% sysinfo
  Name                      Value
  ------------------------- -----------------------------------------------------------
  BIOS Version              1.3
  BIOS Vendor               American Megatrends Inc.
  BIOS Date
  Motherboard Manufacturer
  Motherboard Name
  System Manufacturer       NVIDIA
  System Name               SN2201
  Vendor Tag
  Total Memory              8048771072 bytes (7.496GB)
  Swap Memory               0 bytes (0B)
  OS Name                   Linux
  OS Version                5.10.0-cl-1-amd64
  OS Flavor                 #1 SMP Debian 5.10.162-1+cl5.4.0u1 (2023-01-20)
  Number of Physical CPUs   1
  Number of Cores           2
  Core 0-1                  Intel(R) Atom(TM) CPU C3338R @ 1.80GHz
  Number of Disks           1
  Total Disk Space          115,923,419,136 bytes (115GB)
  Disk /dev/nvme0n1p4       (19,320,569,856 bytes, 19.3GB) ()
  SELinux                   no
  FIPS                      no
  Fabric                    no
  Age                       21h 58m
  ZTP/date                  Tue Apr 11 09:50:21 2023 UTC
  ZTP/method                ZTP DHCP
  ZTP/result                success
  ZTP/state                 enabled
  ZTP/url                   http://10.141.255.254:8080/switch/myswitch/cumulus-ztp.sh
  ZTP/version               1.0
  [basecm10->device[myswitch]]%
  ```

* systemd services can be added for the device via roles, and listed in the `services` submode (section [3.14](#314-managing-and-configuring-services)). Management of services is a standard part of CMDaemon Lite since NVIDIA Base Command Manager version 10.23.06.

* configuration via `cmsh`: can be set up via either a YAML file, or manually, or automatically with some optional manual parts. The appropriate mode is set using the `cumulusmode` setting for the Cumulus device:

  ```bash
  [basecm10->device[cumulus02]]% set cumulusmode <tab><tab>
  auto    file    manual
  ```

  * `auto`: BCM settings such as for `hostname` or `timezone` for a Cumulus switch network configuration are converted automatically to run as `nv` commands. All the `nv` commands carried out on the switch via BCM, whether from an automatic conversion or not, can be viewed within the `cumulus` submode. The `nv` commands that have been automatically converted from BCM settings are assigned a type value of `auto`, and can be viewed within the `cumulus` submode:

    **Example**

    ```bash
    [basecm10->device[myswitch]->cumulus]% show
    Type     #Index   Command
    -------- -------- ----------------------------------------------------------------
    auto     1        nv set system hostname myswitch
    auto     2        nv set system timezone Europe/Amsterdam
    auto     3        nv set service snmp-server enable on
    auto     4        nv set service snmp-server listening-address all
    auto     5        nv set service snmp-server listening-address all-v6
    auto     6        nv set service snmp-server readonly-community public access any
    auto     7        nv set service ntp mgmt pool 10.141.255.254
    auto     8        nv set service dns mgmt server 10.141.255.254
    auto     9        nv set service syslog mgmt server 10.141.255.254 port 514
    auto     10       nv set service syslog mgmt server 10.141.255.254 protocol udp
    auto     11       nv set bridge domain br_default type vlan-aware
    [basecm10->device[myswitch]->cumulus]%
    ```

    The settings are applied to the switch when the `apply` command is run within the `cumulus` mode.

  * `manual`: If the `cumulusmode` setting is `manual` then the commands of type `auto` (as shown within the preceding example) are ignored. Direct `nv` commands can be entered by the administrator manually from within the `manual` Cumulus mode.

    Direct `nv` commands can actually also be added within the `auto` Cumulus mode, and are in that case also of type `manual`:

    **Example**

    ```bash
    [basecm10->device[myswitch]->cumulus]% nv set interface swp27 ip address 10.141.255.123
    [basecm10->device*[myswitch*]->cumulus*]% show
    Type     #Index   Command
    -------- -------- ----------------------------------------------------------------
    auto     1        nv set system hostname myswitch
    ...
    auto     11       nv set bridge domain br_default type vlan-aware
    manual   1        nv set interface swp27 ip address 10.141.255.123
    ```

    The changes are applied when the `apply` command is run within the `cumulus` mode.

    Only commands of type `manual` can be removed from the `cumulus` mode. The removal can be carried out from within `cumulus` mode with the help of the `manual` command and the `nv del` command:

    **Example**

    ```bash
    [basecm10->device*[myswitch]->cumulus]%  ..; get cumulusmode; cumulus
    AUTO
    [basecm10->device*[myswitch]->cumulus]% show
    ...
    auto     11       nv set bridge domain br_default type vlan-aware
    manual   1        nv set interface swp27 ip address 10.141.255.123
    manual   2        nv set system timezone Europe/Berlin
    manual   3        nv set service snmp-server listening-address all-v6

    [basecm10->device*[myswitch]->cumulus]% manual   #cumulus mode changes to manual
                                                     #copies all types to be manual
    [basecm10->device*[myswitch]->cumulus]%  ..; get cumulusmode; cumulus
    MANUAL
    [basecm10->device*[myswitch]->cumulus]% show
    manual   1        nv set interface swp27 ip address 10.141.255.123
    manual   2        nv set system timezone Europe/Berlin
    manual   3        nv set service snmp-server listening-address all-v6
    [basecm10->device*[myswitch]->cumulus]% nv del 1-2
    [basecm10->device*[myswitch]->cumulus]% commit
    [basecm10->device*[myswitch]->cumulus]% apply  #only now is switch updated
    ```

    The `manual` command switches the `cumulusmode` to `manual`, and copies the stack of `auto` type commands over to the stack in `manual` mode. The `commit` command saves the configuration in the CMDaemon database. As usual, the configuration defined by the `manual` Cumulus mode is only applied to the switch after using the `apply` command.

    The stack in the `manual` mode stack is then what is used on the switch instead of the `auto` mode stack, as per the CMDaemon state.

  * `file`: If the `cumulusmode` setting is `file`, then a YAML file is used by BCM to carry out the commands. A sample YAML file that uses the currently running configuration of the switch can be displayed by running\
    `nv config show`\
    on the switch.

    **Example**

    ```bash
    [basecm10->device[myswitch]]% set cumulusmode file
    [basecm10->device*[myswitch*]]% set cumulusfile startup.yaml
    [basecm10->device*[myswitch*]]% commit
    ```

    The `apply` command is not used for the `file` mode, since the commands are carried out over ZTP.

* the ZTP configuration can be managed from `ztpsettings` mode:

  **Example**

  ```bash
  [basecm10->device[cumulus02]]% ztpsettings
  [basecm10->device[cumulus02]->ztpsettings]% show
  Parameter                            Value
  ------------------------------------ ------------------------------------------------
  Revision
  Script template                      cumulus-ztp.sh
  Image                                cumulus-linux-5.5.0-mlx-amd64.bin
  Check image on boot                  yes
  Run ZTP on each boot                 yes
  Authorized key file root             /root/.ssh/authorized_keys
  Authorized key file cumulus
  Enable API                           no
  Enable external access API           no
  Merge key value settings partition   no
  Key value settings                   <submode>
  ```

  Notes about some of the `ztpsettings`:

  * By default, `authorizedkeyfileroot` is not set, which means that user `root` cannot access the switch with public key authentication.

  * By default, `authorizedkeyfilecumulus` is not set. The user `cumulus` is the API user.

  * Cumulus images for the switch, set by `image`, are provisioned from the head node. Cumulus images can be picked up from [https://enterprise-support.nvidia.com/s/downloads](https://enterprise-support.nvidia.com/s/downloads) and can then be placed on the head node at `/cm/local/apps/cmd/etc/htdocs/switch/images/`.

  * The `checkimageonboot` setting checks that the existing image on the switch matches the image that can be offered via ZTP. If it does not, then the switch updates its image, picking it up via ZTP.

  * The file specified by `scripttemplate` is used to generate a ZTP provisioning file on-demand when the switch boots. Running `initialize` from the switch object level (at `cumulus02` level in the preceding example) generates the file without a reboot.

* The `switchoverview` command returns output such as:

  ```bash
  [basecm10->device[cumulus01]]% switchoverview
  Device: cumulus01
  State : [   UP   ]
  Model : Cumulus Linux 5.2.1
  Port    Name    Status  Assigned        Uplink Speed            Detected
  ----    ------  ------- ------------    ------ -----------      ----------------------------
  1       swp1    DOWN                    no     0 b/s            bridge domains: cm-default
  2       swp2    DOWN                    no     0 b/s            bridge domains: cm-default
  3       swp3    DOWN                    no     0 b/s            bridge domains: cm-default
  4       swp4    DOWN                    no     0 b/s            bridge domains: cm-default
  5       swp5    UP      node001-dpu     no     100 Gb/s         bridge domains: cm-default
  6       swp6    DOWN                    no     0 b/s            bridge domains: cm-default
  7       swp7    UP      node002-dpu     no     100 Gb/s         bridge domains: cm-default
  ```

* The `switchports` command ([here](#3911-port-assignments-for-switches)) is used to configure the port assignment between the nodes and the switch ports. Configuring the port assignment at `interfaces` level is needed to allow CMDaemon Lite to manage Cumulus network configuration.

  **Example**

  ```bash
  [basecm10->device[node002]]% interfaces node004
  [basecm10->device[node004]->interfaces]% set DPU1 switchports cumulus01:4
  ```

#### 3.10.2.2  Custom Services Option 2: Cumulus With A YAML Preconfiguration

A YAML configuration can be used outside of `cmsh`. DGX SuperPODS use this option during the standard BCM installation. It means that CMDaemon Lite running on the switch (section [3.10.2.1](#31021-custom-services-option-1-cumulus-with-cmdaemon-lite)) does not need to be used. Instead, two custom-generated YAML files are used.

The YAML files that are generated are:

* `startup.yaml`: this contains a sequence of Cumulus `nv` commands

* `cm-startup.yaml`: this contains the BCM DGX/switch definitions to be added by pythoncm

The `cm-startup.yaml` file is parsed, and the devices that are defined within it are configured with the PythonCM ([Chapter 1 of the *Developer Manual*](/developer/pythonapi)) script, `cm-import-startup`.

The devices are then powered on in the correct order.

The YAML file `startup.yaml` can be handled manually (using `scp` and the `nv apply` command), or by using ZTP, or by using Ansible.

#### 3.10.2.3  Settings Applied Via ZTP

The configuration script `cumulus-ztp.sh` template, found under `/cm/local/apps/cmd/etc/htdocs/switch/template`, can be customized to suit the requirements.

The YAML file `startup.yaml` is placed under:

`/cm/local/apps/cmd/etc/htdocs/switch/` \<*switch or host name*>`/`

This allows it to be picked up automatically via ZTP, and the `nv` commands are applied it to the switch on boot.

CMDaemon Lite is not required, but can be installed separately.

#### 3.10.2.4  Settings Applied Via Ansible

Alternatively, Ansible can be used to push the YAML configuration to each switch.

With an Ansible installation, ZTP is not required, but it can be used. CMDaemon Lite is not required for applying the settings via Ansible either, but can be installed separately.

### 3.10.3  Uplink Ports

Uplink ports are switch ports that are connected to other switches. CMDaemon must be told about any switch ports that are uplink ports, or the traffic passing through an uplink port will lead to mistakes in what CMDaemon knows about port and MAC correspondence. Uplink ports are thus ports that CMDaemon is told to ignore.

To inform CMDaemon about what ports are uplink ports, Base View or `cmsh` are used:

* In Base View, the switch is selected, and uplinks can be added via the navigation path\
  `Devices` > `Switches` > `Edit` > `Uplinks`\
  (figure [3.16](#fig-bright-view-configuringswitchesuplinks)):

![Notifying CMDaemon about uplinks with Base View](/base-command-manager/product-manuals/_fern-img/cb03d3d1e1d55358331bf0f8c45bf941097bb9e0d1b7b1c7d8671592e98069a4.webp)

*Figure 3.16: Notifying CMDaemon about uplinks with Base View*

A dialog box then appears, and allows uplink port numbers to be added with a ⊕ button. The state is saved with the `SAVE` button of figure [3.16](#fig-bright-view-configuringswitchesuplinks).

* In `cmsh`, the switch is accessed from the `device` mode. The uplink port numbers can be appended one-by-one with the `append` command, or `set` in one go by using space-separated numbers.

  **Example**

  ```bash
  [root@basecm10 ~]# cmsh
  [basecm10]% device
  [basecm10->device]% set switch01 uplinks 15 16
  [basecm10->device*]% set switch02 uplinks 01
  [basecm10->device*]% commit
  successfully committed 3 Devices
  ```

### 3.10.4  The `showport` MAC Address to Port Matching Tool

The `showport` command can be used in troubleshooting network topology issues, as well as checking and setting up new nodes (section [5.4.2](/admin/provisioning#542-deciding-or-selecting-node-configuration)).

#### 3.10.4.1  Basic Use Of `showport`

In the `device` mode of `cmsh` is the `showport` command, which works out which ports on which switch are associated with a specified MAC address.

**Example**

```bash
[root@basecm10 ~]# cmsh
[basecm10]% device
[basecm10->device]% showport 00:30:48:30:73:92
switch01:12
```

When running `showport`, CMDaemon on the head node queries all switches until a match is found.

If a switch is also specified using the “`-s`” option, then the query is carried out for that switch first. Thus the preceding example can also be specified as:

```bash
[basecm10->device]% showport -s switch01 00:30:49.00:73:92
switch01:12
```

If there is no port number returned for the specified switch, then the scan continues on other switches.

#### 3.10.4.2  Mapping All Port Connections In The Cluster With `showport`

A list indicating the port connections and switches for all connected devices that are up can be generated using this script:

**Example**

```bash
#!/bin/bash
for nodename in $(cmsh -c "device; foreach * (get hostname)")
do
  macad=$(cmsh -c "device use $nodename; get mac")
  echo -n "$macad $nodename "
  cmsh -c "device showport $macad"
done
```

The script may take a while to finish its run. It gives an output like:

**Example**

```bash
00:00:00:00:00:00 switch01: No ethernet switch found connected to this mac address
00:30:49.00:73:92 basecm10: switch01:12
00:26:6C:F2:AD:54 node001: switch01:1
00:00:00:00:00:00 node002: No ethernet switch found connected to this mac address
```

### 3.10.5  Disabling Port Detection

An administrator may wish to disable node identification based on port detection. For example, in the case of switches with buggy firmware, the administrator may feel more comfortable relying on MAC-based identification. Disabling port detection can be carried out by clearing the `switchports` setting of a node, a category, or a group. For example, in `cmsh`, for a node:

**Example**

```bash
[root@basecm10 ~]# cmsh
[basecm10]% device use node001
[basecm10->device[node001]]% clear switchports
[basecm10->device*[node001*]]% commit
[basecm10->device[node001]]%
```

Or, for example for the `default` category, with the help of the `foreach` command:

**Example**

```bash
[root@basecm10 ~]# cmsh
[basecm10]% device
[basecm10->device]]% foreach -c default (clear switchports); commit
```

### 3.10.6  The `switchoverview` Command

Also within `device` mode, the `switchoverview` command gives an overview of MAC addresses detected on the ports, and some related properties. The command works using SNMP queries. Output is similar to the following (some lines ellipsized):

```bash
[basecm10->device]% switchoverview dell-switch1
Device: dell-switch1
State : [   UP   ]
Model : 24G Ethernet Switch

Port Assignment:

Port   Status Assigned         Uplink Speed    Detected
------ ------ ---------------- ------ -------- --------------------------\
--------------------------------------------------------------------
1      UP                      false  1 Gb/s   -
2      UP                      false  1 Gb/s   -
3      UP                      false  1 Gb/s   74:86:7A:AD:3F:2F, node3
4      UP                      false  1 Gb/s   74:86:7A:AD:43:E9, node4
...
11     UP                      false  1 Gb/s   74:86:7A:AD:44:D8, node11
12     UP                      false  1 Gb/s   74:86:7A:AD:6F:55, node12
...
23     UP                      false  1 Gb/s   74:86:7A:E9:3E:85, node23
24     UP                      false  1 Gb/s   74:86:7A:AD:56:DF, node24
49     UP                      false  10 Gb/s  74:86:7A:AD:68:FD, node1
50     UP                      false  10 Gb/s  74:86:7A:AD:41:A0, node2
53     UP     node34           false  1 Gb/s   5C:F9:DD:F5:79.0D, node34
54     UP     node35           false  1 Gb/s   5C:F9:DD:F5:45:AC, node35
...
179    UP                      false  1 Gb/s   24:B6:FD:F6:20:6F,\
 24:B6:FD:FA:64:2F, 74:86:7A:DF:7E:4C, 90:B1:1C:3F:3D:A9,\
 90:B1:1C:3F:51:D1, D0:67:E5:B7:64:0F, D0:67:E5:B7:61:20
180    UP                      false  100 Mb/s QDR-switch
205    UP                      true   10 Gb/s  -
206    DOWN                    false  10 Gb/s  -
...
[basecm10 ->device]%
```

## 3.11  Configuring NetQ Network Management System

NetQ telemetry data values are produced by NetQ. A running NetQ server can be integrated with BCM by configuring its credentials and connectivity settings in the `netqsettings` submode from within the `partition` mode of BCM:

**Example**

```bash
[basecm10->partition[base]]% netqsettings
[basecm10->partition*[base*]->netqsettings*]% show
Parameter                        Value
-------------------------------- ------------------------------------------------
Revision
Server
User name
Password                         < not set >
Port                             443
Verify SSL                       no
[basecm10->partition*[base*]->netqsettings*]% set username <NetQ username>
[basecm10->partition*[base*]->netqsettings*]% set password <NetQ password>
[basecm10->partition*[base*]->netqsettings*]% set server <NetQ hostname or IP address>
[basecm10->partition*[base*]->netqsettings*]% commit
```

Connecting to the NetQ server allows NetQ telemetry data values to be picked up by BCM. These values are then treated as measurables (section [12.2.1](/admin/monitoring#1221-measurables)). NetQ measurables (sections [G.1.13](/admin/metricshealthchecksactions#g113-netq-metrics) and [G.2.4](/admin/metricshealthchecksactions#g24-netq-health-checks)) can be managed and displayed with BCM just like other measurables.

## 3.12  Disk Layouts: Disked, Semi-Diskless, And Diskless Node Configuration

Configuring the disk layout for head and regular nodes is done as part of the initial setup ([section 3.3.16 of the *Installation Manual*](/installation/installing#3316-disk-layout)). For regular nodes, the disk layout can also be re-configured by BCM once the cluster is running. For a head node, however, the disk layout cannot be re-configured after installation by BCM, and head node disk layout reconfiguration must then therefore be treated as a regular Linux system administration task, typically involving backups and resizing partitions.

The remaining parts of this section on disk layouts therefore concern regular nodes, not head nodes.

### 3.12.1  Disk Layouts

A disk layout is specified using an XML schema (Appendix [D.1](/admin/partitioning#d1-structure-of-partitioning-definitionthe-global-partitioning-xml-schema-definition-file)). The disk layout typically specifies the devices to be used, its partitioning scheme, and mount points. Possible disk layouts include the following:

* Default layout (Appendix [D.3](/admin/partitioning#d3-example-default-node-partitioning))

* Hardware RAID setup (Appendix [D.4](/admin/partitioning#d4-example-hardware-raid-configuration))

* Software RAID setup (Appendix [D.5](/admin/partitioning#d5-example-software-raid))

* LVM setup (Appendix [D.7](/admin/partitioning#d7-example-logical-volume-manager))

* Diskless setup (Appendix [D.9](/admin/partitioning#d9-example-diskless))

* Semi-diskless setup (Appendix [D.10](/admin/partitioning#d10-example-semi-diskless))

### 3.12.2  Disk Layout Assertions

Disk layouts can be set to *assert*

* that particular hardware be used, using XML element tags such as `vendor` or `requiredSize` (Appendix [D.11](/admin/partitioning#d11-example-preventing-accidental-data-loss))

* custom assertions using an XML `assert` element tag to run scripts placed in CDATA sections (Appendix [D.12](/admin/partitioning#d12-example-using-custom-assertions))

### 3.12.3  Changing Disk Layouts

A disk layout applied to a category of nodes is inherited by default by the nodes in that category. A disk layout that is then applied to an individual node within that category overrides the category setting. This is an example of the standard behavior for categories, as mentioned in section [2.1.3](/admin/clustermanagement#213-node-categories).

By default, the cluster is configured with a standard layout specified in section [D.3](/admin/partitioning#d3-example-default-node-partitioning). The layouts can be accessed from Base View or `cmsh`, as is illustrated by the example in section [3.12.4](#3124-changing-a-disk-layout-from-disked-to-diskless), which covers changing a node from disked to diskless mode:

### 3.12.4  Changing A Disk Layout From Disked To Diskless

The XML schema for a node configured for diskless operation is shown in Appendix [D.9](/admin/partitioning#d9-example-diskless). This can often be deployed as is, or it can be modified during deployment using Base View or `cmsh` as follows:

#### 3.12.4.1  Changing A Disk Layout Using Base View

To change a disk layout with Base View, the current disk layout is accessed by selecting a node category or a specific node from the resource tree in the navigation panel. For a node, the navigation path is\
`Devices` > `Nodes` > `Edit` > `Settings` > `Installing` > `Disk setup`\
(figure [3.17](#fig-ChangingADiskedNodeToADisklessNodeWithbright-view)):

![Changing a disked node to a diskless node with Base View](/base-command-manager/product-manuals/_fern-img/aae9bb57b633ed4429bed1419fab8037da645ada1b6f0e4149fa7424a70817e8.webp)

*Figure 3.17: Changing a disked node to a diskless node with Base View*

The `Disk setup` field can then be edited.

Clicking on the `Select from template` button shows several possible ready-made configurations that can be loaded up from the CMDaemon database, and if desired, the copy stored for the node can be edited to suit the situation.

To switch from the existing disk layout to a diskless one, the diskless XML configuration template is loaded via the `Select from template` button, and saved to the node or node category.

The `Browse` button can be used to upload a custom configuration via the browser, and there is also a `Copy from Category:default` button that can be used to copy the category configuration to the node.

#### 3.12.4.2  Changing A Disk Layout Using `cmsh`

To edit an existing disk layout from within `cmsh`, the existing XML configuration is accessed by editing the `disksetup` property in `device` mode for a particular node, or by editing the `disksetup` property in `category` mode for a particular category. Editing is done using the `set` command, which opens up a text editor:

**Example**

```bash
[root@basecm10 ~]# cmsh
[basecm10]% device use node001
[basecm10->device[node001]]% set disksetup
```

After editing and saving the XML configuration, the change is then committed to CMDaemon with the `commit` command. It should be understood that a disk layout XML configuration is not stored in a file on the filesystem, but in the CMDaemon database. The XML configurations that exist on a default cluster at\
`/cm/images/default-image/cm/local/apps/cmd/etc/htdocs/disk-setup/`\
and\
`/cm/local/apps/cmd/etc/htdocs/disk-setup/`\
are merely default configurations.

If the `disksetup` setting for a device is deleted, using the `clear` command, then the category level `disksetup` property is used by the device. This is in accordance with the usual behavior for node values that override category values (section [2.1.5](/admin/clustermanagement#215-roles)).

Instead of editing an existing disk layout, another XML configuration can also be assigned. A diskless configuration may be chosen and set as follows:

**Example**

```bash
[basecm10->device[node001]]% set disksetup /cm/local/apps/cmd/\
etc/htdocs/disk-setup/slave-diskless.xml
```

In these preceding Base View and `cmsh` examples, after committing the change and rebooting the node, the node then functions entirely from its RAM, without using its own disk.

However, RAM is usually a scarce resource, so administrators often wish to optimize diskless nodes by freeing up the RAM on them from the OS that is using the RAM. Freeing up RAM can be accomplished by providing parts of the filesystem on the diskless node via NFS from the head node. That is, mounting the regular node with filesystems exported via NFS from the head node. The details of how to do this are a part of section [3.13](#313-configuring-nfs-volume-exports-and-mounts), which covers the configuration of NFS exports and mounts in general.

## 3.13  Configuring NFS Volume Exports And Mounts

NFS allows unix NFS clients shared access to a filesystem on an NFS server. The accessed filesystem is called an NFS volume by remote machines. The NFS server exports the filesystem to selected hosts or networks, and the clients can then mount the exported volume locally.

An unformatted filesystem cannot be used. The drive must be partitioned beforehand with `fdisk` or similar partitioning tools, and its filesystem formatted with `mkfs` or similar before it can be exported.

In BCM, the head node is typically used to export an NFS volume to the regular nodes, and the regular nodes then mount the volume locally.

* NFS can be made to work at higher speeds with remote direct memory access (RDMA), by bypassing the CPU. If there is RDMA hardware present, and if the `rdma-core` package is installed, then the RDMA service works automatically in RHEL 8 and 9.

  The settings that determine client module loading are set in the file `/etc/rdma/modules/rdma.conf` so that the service auto-loads by default.

* An alternative to NFS over RDMA for very fast file systems is [the massively parallel and free (GPLv2) Lustre filesystem](https://whamcloud.com), running over InfiniBand.

If auto-mounting is used, then the configuration files for exporting should be set up on the NFS server, and the mount configurations set up on the software images. The service “`autofs`” or the equivalent can be set up using Base View via the “`Services`” option (section [3.14](#314-managing-and-configuring-services)) on the head and regular nodes or node categories. With `cmsh` the procedure to configure auto-mounting on the head and regular nodes could be:

**Example**

```bash
[root@basecm10 ~]# cmsh
[basecm10]% device use basecm10
[basecm10->device[basecm10]]% services
[basecm10->device[basecm10]->services]% add autofs
[basecm10->device*[basecm10*]->services*[autofs*]]% show
Parameter                        Value
------------------------------   -------------------------------------
Autostart                        no
Belongs to role                  no
Monitored                        no
Revision
Run if                           ALWAYS
Service                          autofs
Sickness check interval          60
Sickness check script
Sickness check script timeout    10
Timeout                          -1
[basecm10->device*[basecm10*]->services*[autofs*]]% set autostart yes
[basecm10->device*[basecm10*]->services*[autofs*]]% commit
[basecm10->device[basecm10]->services[autofs]]% category use default
[basecm10->category[default]]% services
[basecm10->category[default]->services]% add autofs
[basecm10->category*[default*]->services*[autofs*]]% set autostart yes
[basecm10->category*[default*]->services*[autofs*]]% commit
[basecm10->category[default]->services[autofs]]%
```

Filesystems imported to a regular node via an auto-mount operation must explicitly be excluded in `excludelistupdate` by the administrator, as explained in section [5.6.1.2](/admin/provisioning#5612-the-exclude-list-logic-for-excludelistupdate), [here](/admin/provisioning#automounterbeware).

The rest of this section describes the configuration of NFS for static mounts, using Base View or `cmsh`.

Sections [3.13.1](#3131-exporting-a-filesystem-using-base-view-and-cmsh) and [3.13.2](#3132-mounting-a-filesystem-using-base-view-and-cmsh) explain how exporting and mounting of filesystems is done in general by an administrator using Base View and `cmsh`, and considers some mounting behavior that the administrator should be aware of.

Section [3.13.3](#3133-mounting-a-filesystem-subtree-for-a-diskless-node-over-nfs) discusses how filesystems in general on a diskless node can be replaced via mounts of NFS exports.

Section [3.13.4](#3134-configuring-nfs-volume-exports-and-mounts-over-rdma-with-ofed-drivers) discusses how OFED InfiniBand or iWarp drivers can be used to provide NFS over RDMA.

### 3.13.1  Exporting A Filesystem Using Base View And `cmsh`

#### 3.13.1.1  Exporting A Filesystem Using Base View

As an example, if an NFS volume exists at “`basecm10:/modeldata`” it can be exported using Base View using the head node navigation path:\
`Devices` > `Head nodes`\[`basecm10`] > `Settings[JUMP TO``]` > `Filesystem exports`\
This shows the list of exports (figure [3.18](#fig-bright-view-headnodes-fsexports-list)):

![NFS exports from a head node viewed using Base View](/base-command-manager/product-manuals/_fern-img/83c1cf0e09f834cf1194b245824f7875de07b67c4bf76e1cc190ccb9aa168455.webp)

*Figure 3.18: NFS exports from a head node viewed using Base View*

Using the `Add` button, and selecting `FSExport` from the popup, a new entry (figure [3.19](#fig-bright-view-headnodes-fsexports-add)) can be configured with values as shown:

![Setting up an NFS export using Base View](/base-command-manager/product-manuals/_fern-img/e03f1681b8c6a32da632afbdb6cc80f66f764c4a3f1c17f2a03945145c129ea1.webp)

*Figure 3.19: Setting up an NFS export using Base View*

For this example, the value for “`Name`” is set arbitrarily to “`Fluid Model Data`”, the value for `Path` is set to `/modeldata`, and the value for `Network` is set from the selection menu to allowing access to `internalnet` (by default `10.141.0.0/16` in CIDR notation).

By having the `Write` option disabled, read-only access is kept.

Saving this preceding configuration means the NFS server now provides NFS access to this filesystem for `internalnet`.

The network can be set to other network values using CIDR notation. It can also be set to particular hosts such as just node001 and node002, by specifying a value of “`node001 node002`” instead. Other settings and options are also possible and are given in detail in the man pages for `exports(5)`.

#### 3.13.1.2  Exporting A Filesystem Using `cmsh`

The equivalent to the preceding Base View NFS export procedure can be done in `cmsh` by using the `fsexports` submode on the head node (some output elided):

**Example**

```bash
[root@basecm10 ~]# cmsh
[basecm10]% device use basecm10
[basecm10->device[basecm10]]% fsexports
[...->fsexports]% add "Fluid Model Data"
[...->fsexports*[Fluid Model Data*]]% set path /modeldata
[...[Fluid Model Data*]]% set hosts 10.141.0.0/16
[...[Fluid Model Data*]]% commit
[...->fsexports[Fluid Model Data]]% list | grep Fluid
Name (key)           Path            Hosts            Write
-------------------  -------------   ---------------  ------
Fluid Model Data     /modeldata      10.141.0.0/16    no
```

#### 3.13.1.3  General Considerations On Exporting A Filesystem

**Built-in exports:** In versions of NVIDIA Base Command Manager prior to version 9.0, all filesystem exports could be removed from the `fsexports` submode, simply by using the `remove` command with the name of the export.

From version 9.0 onward however, the following filesystem exports:

* `/var/spool/burn`

* `/home`

* `/cm/shared`

are treated as special built-ins.

**Head node role and `disableautomaticexports`:** Built-ins are exported automatically as part of the `headnode` role, also introduced in NVIDIA Base Command Manager 9.0, and cannot simply be removed.

To disable export of the built-in file systems, the `disableautomaticexports` command must be run in the `headnode` role for that node:

**Example**

```bash
[root@basecm10 ~]# cmsh
[basecm10]% device use basecm10
[basecm10->device[basecm10]]% roles
[basecm10->device[basecm10]->roles]% use headnode
[basecm10->device[basecm10]->roles[headnode]]% show
Parameter                        Value
-------------------------------- -----------------------
Name                             headnode
Revision
Type                             HeadNodeRole
Add services                     yes
Disable automatic exports        no
[basecm10->device[basecm10]->roles[headnode]]% set disableautomaticexports yes ; commit
```

**Disabling exports that are not built-ins:** Exports that are not built-ins can still simply be removed. However, also from NVIDIA Base Command Manager 9.0 onward they can also simply be disabled in the `fsexports` submode. For example there is an export created by the cluster administrator for `/opt`, it can be disabled as follows:

**Example**

```bash
[basecm10->device[basecm10]->fsexports]% list
Name (key)       Path                Network     Disabled
---------------- -------      ...    ----------- --------
opt              /opt                internalnet no
[basecm10->device[basecm10]->fsexports]% set opt disabled yes; commit
```

The reason for automating the export for nodes via a `headnode` role is that NVIDIA Base Command Manager 9.0 onward has multidistro and multiarch capabilities (section [11.7](/admin/softwareimagemanagement#117-creating-images-for-other-distributions-and-architectures-multidistro-and-multiarch)), which would make manual management of exports harder for such nodes. The reason for the extra hurdle of `disableautomaticexports` for built-ins is that disabling these exports can result in an unbootable system.

### 3.13.2  Mounting A Filesystem Using Base View And `cmsh`

Continuing on with the `Fluid Model Data` export example from the preceding section, the administrator decides to mount the remote filesystem over the default category of nodes. Nodes can also mount the remote filesystem individually, but that is usually not a common requirement in a cluster. The administrator also decides not to re-use the exported name from the head node. That is, the remote mount name `modeldata` is not used locally, even though NFS allows this and many administrators prefer to do this. Instead, a local mount name of `/modeldatagpu` is used, perhaps because it avoids confusion about which filesystem is local to a person who is logged in, and perhaps to emphasize the volume is being mounted by nodes with GPUs.

#### 3.13.2.1  Mounting A Filesystem Using Base View

In Base View the navigation path to manage the mount points of a category such as `default` is:

`Grouping` > `Categories`\[default] > `Edit` > `Settings[JUMP TO``]` > `Filesystem mounts`

A mount point can be added with the `ADD` button, and clicking on the popup `FSMount`. Values for the remote mount point (`basecm10:/modeldata`), the filesystem type (`nfs`), and the local mount point (`/modeldatagpu`) can then be set in category mode, while the remaining options stay at their default values (figure [3.20](#fig-bright-view-node-category-fsmounts-add)):

![Setting up NFS mounts on a node category using Base View](/base-command-manager/product-manuals/_fern-img/b4b1343dc57f1964b45f862871f481ccf4dfc794ed2ef3195d253afe1ab1c18d.webp)

*Figure 3.20: Setting up NFS mounts on a node category using Base View*

Saving the configuration saves the values and creates the local mount point, so that the volume can then be accessed by nodes within that category.

#### 3.13.2.2  Mounting A Filesystem Using `cmsh`

The equivalent to the preceding Base View NFS mount procedure can be done in `cmsh` by using the `fsmounts` submode, for example on the `default` category. The `add` method under the `fsmounts` submode sets the mountpoint path, in this case `/modeldatagpu` (some output elided):

**Example**

```bash
[root@basecm10 ~]# cmsh
[basecm10]% category use default
[basecm10->category[default]]% fsmounts
[basecm10->category[default]->fsmounts]% add /modeldatagpu
[basecm10->...*[/modeldatagpu*]]% set device basecm10:/modeldata
[basecm10->...*[/modeldatagpu*]]% set filesystem nfs
[basecm10->category*[default*]->fsmounts*[/modeldatagpu*]]% commit
[basecm10->category[default]->fsmounts[/modeldatagpu]]%
Device                  Mountpoint (key)     Filesystem
---------------------   ------------------   ----------
...
basecm10:/modeldata     /modeldatagpu        nfs
[basecm10->category[default]->fsmounts[/modeldatagpu]]% show
Parameter             Value
-------------------   ---------------------
Device                basecm10:/modeldata
Dump                  no
Filesystem            nfs
Filesystem Check      NONE
Mount options         defaults
Mountpoint            /modeldatagpu
```

Values can be `set` for `Mount options` other than default. For example, the `noac` flag can be added as follows:

```bash
[basecm10->...[/modeldatagpu]]% set mountoptions defaults,noac; commit
```

Mounting a CIFS might use:

```bash
[basecm10->...[/modeldatagpu]]% set mountoptions gid,users,file_mode=0666,dir_mode=0777,\
iocharset=iso8859-15,credentials=/path/to/credential
[basecm10->...[/modeldatagpu*]]% commit
```

A `_netdev` mount option to make systemd wait until the network is up before it is mounted can be added as follows:

```bash
[basecm10->...[/modeldatagpu]]% append mountoptions ,_netdev; commit
```

#### 3.13.2.3  General Considerations On Mounting A Filesystem

There may be a requirement to segregate the access of nodes. For example, in the case of the preceding, because some nodes have no associated GPUs.

Besides the “`Allowed hosts`” options of NFS exports mentioned earlier in section [3.13.1.1](#31311-exporting-a-filesystem-using-base-view), BCM offers two more methods to fine tune node access to mount points:

* Nodes can be placed in another category that does not have the mount point.

* Nodes can have the mount point set, not by category, but per device within the `Nodes` resource. For this, the administrator must ensure that nodes that should have access have the mount point explicitly set.

Other considerations on mounting are that:

* When adding a mount point object:

  * The settings take effect right away by default on the nodes or node categories.

  * If `noauto` is set as a mount option, then the option only takes effect on explicitly mounting the filesystem.

  * If “`AutomaticMountAll=0`” is set as a CMDaemon AdvancedConfig directive (Appendix [C.106](/admin/cmdconf#c106-automaticmountall-directive), [here](/admin/cmdconf#c106-automaticmountall-directive)), then CMDaemon changes for `/etc/fstab` are written to the file, but the `mount -a` command is not run by CMDaemon. However, the administrator should be aware that since `mount -a` is run by the distribution during booting, a node reboot implements the mount change.

* While a mount point object may have been removed, umount does not take place until reboot, to prevent mount changes outside of the cluster manager. If a umount needs to be to done without a reboot, then it should be done manually, for example, using the `pdsh` or `pexec` command (section [16.1.0.1](/admin/administration#16101-what-pdsh-and-pexec-do)), to allow the administrator to take appropriate action if umounting goes wrong.

* When manipulating mount points, the administrator should be aware which mount points are inherited by category, and which are set for the individual node.

  * In Base View, for a node, [inheritance by category](/admin/clustermanagement#213-node-categories) is indicated in the navigation path `Devices` > `Nodes[`*`node name`*`]` > `Edit` > `Settings` > `Filesystem mounts`, under the `INHERITED` column, with the entry `(Category)`.

  * In `cmsh`, the category a mount belongs to is displayed in brackets. This is displayed from within the `fsmounts` submode of the `device` mode for a specified node:

    **Example**

    ```bash
    [root@basecm10 ~]# cmsh -c "device; fsmounts node001; list"

    Device                   Mountpoint (key)     Filesystem
    ------------------------ -------------------- ----------
    [default] none           /dev/pts             devpts
    [default] none           /proc                proc
    [default] none           /sys                 sysfs
    [default] none           /dev/shm             tmpfs
    [default] $localnfsserv+ /cm/shared           nfs
    [default] basecm10:/home /home                nfs
    basecm10:/cm/shared/exa+ /home/examples       nfs
    [root@basecm10 ~]#
    ```

  To remove a mount point defined at category level for a node, it must be removed from within the category, and not from the specific node.

#### 3.13.2.4  Mount Order Considerations

Care is sometimes needed in deciding the order in which mounts are carried out.

* For example, if both `/usr/share/doc` and a replacement directory subtree `/usr/share/doc/compat-gcc-34-3.4.6java` are to be used, then the stacking order should be that `/usr/share/doc` is mounted first. This order ensures that the replacement directory subtree overlays the first mount. If, instead, the replacement directory were the first mount, then it would be overlaid, inaccessible, and inactive.

* There may also be dependencies between the subtrees to consider, some of which may prevent the start up of applications and services until they are resolved. In some cases, resolution may be quite involved.

The order in which such mounts are mounted can be modified with the `up` and `down` commands within the `fsmounts` submode of `cmsh`.

### 3.13.3  Mounting A Filesystem Subtree For A Diskless Node Over NFS

#### 3.13.3.1  NFS Vs `tmpfs` For Diskless Nodes

For diskless nodes (Appendix [D.9](/admin/partitioning#d9-example-diskless)), the software image (section [2.1.2](/admin/clustermanagement#212-software-images)) is typically installed from a provisioning node by the node-installer during the provisioning stage, and held as a filesystem in RAM on the diskless node with the `tmpfs` filesystem type.

It can be worthwhile to replace subtrees under the diskless node filesystem held in RAM with subtrees provided over NFS. This can be particularly worthwhile for less frequently accessed parts of the diskless node filesystem. This is because, although providing the files over NFS is much slower than accessing it from RAM, it has the benefit of freeing up RAM for tasks and jobs that run on diskless nodes, thereby increasing the cluster capacity.

An alternative “semi-diskless” way to free up RAM is to use a local disk on the node itself for supplying the subtrees. This is outlined in Appendix [D.10](/admin/partitioning#d10-example-semi-diskless).

#### 3.13.3.2  Moving A Filesystem Subtree Out Of `tmpfs` To NFS

To carry out subtree provisioning over NFS, the subtrees are exported and mounted using the methods outlined in the previous examples in sections [3.13.1](#3131-exporting-a-filesystem-using-base-view-and-cmsh) and [3.13.2](#3132-mounting-a-filesystem-using-base-view-and-cmsh). For the diskless case, the exported filesystem subtree is thus a particular path under `/cm/images/` \<*`image`*> on the provisioning node, and the subtree is mounted accordingly under `/` on the diskless node. By default, \<*image*> is `default-image` on a newly-installed cluster.

While there are no restrictions placed on the paths that may be mounted in NVIDIA Base Command Manager 10, the administrator should be aware that mounting certain paths such as `/bin` is not possible.

When Base View or `cmsh` are used to manage the NFS export and mount of the subtree filesystem, then `tmpfs` on the diskless node is reduced in size due to the administrator explicitly excluding the subtree from `tmpfs` during provisioning.

An example might be to export `/cm/images/default-image` from the head node, and mount the directory available under it, `usr/share/doc`, at a mount point `/usr/share/doc` on the diskless node. In `cmsh`, such an export can be done by creating an FS export object corresponding to the software image object `defaultimage` with the following indicated properties (some prompt output elided):

**Example**

```bash
[root@basecm10 ~]# cmsh
[basecm10]% device use basecm10; fsexports
[basecm10->device[basecm10]->fsexports]% add defaultimage
[basecm10...defaultimage*]]% set path /cm/images/default-image
[basecm10...defaultimage*]]% set hosts 10.141.0.0/16
[basecm10...defaultimage*]]% commit
[basecm10...defaultimage]]% list | grep defaultimage
Name (key)        Path                      Hosts          Write
----------------  ------------------------  -------------  -----
defaultimage      /cm/images/default-image  10.141.0.0/16  no
```

As the output to `list` shows, the NFS export should be kept read-only, which is the default. Appropriate parts of the export can then be mounted by a node or node category. The mount is defined by setting the mount point, the `nfs` filesystem property, and the export device. For example, for a node category (some output elided):

```bash
[br...defaultimage]]% category use default
[basecm10->category[default]]% fsmounts
[basecm10->category[default]->fsmounts]% add /usr/share/doc
[basecm10->...*[/usr/share/doc*]]% set device basecm10:/cm/images/default-image/usr/share/doc
[basecm10->...*[/usr/share/doc*]]% set filesystem nfs
[basecm10->category*[default*]->fsmounts*[/usr/share/doc*]]% commit
[basecm10->category[default]->fsmounts[/usr/share/doc]]% list
Device                                          Mountpoint (key)     Filesystem
---------------------                           ------------------   ----------
...                                             ...                  ...
basecm10:/cm/images/default-image/usr/share/doc /usr/share/doc       nfs
[basecm10->category[default]->fsmounts[/usr/share/doc]]% show
Parameter          Value
----------------   -----------------------------------------------
Device             basecm10:/cm/images/default-image/usr/share/doc
Dump               no
Filesystem         nfs
Filesystem Check   0
Mount options      defaults
Mountpoint         /usr/share/doc
```

Other mount points can be also be added according to the judgment of the system administrator. Some consideration of mount order may be needed, as discussed [here](#31324-mount-order-considerations) under the subheading “Mount Order Considerations”.

#### 3.13.3.3  An Example Of Several NFS Subtree Mounts

The following mounts save about 440MB from `tmpfs` on a diskless node with Rocky Linux 8, as can be worked out from the following subtree sizes:

```bash
[root@basecm10 ~]# cd /cm/images/default-image/
[root@basecm10 default-image]# du -sh usr/share/locale usr/lib/jvm usr/share/doc usr/src
160M    usr/share/locale
118M    usr/lib/jvm
88M    usr/share/doc
77M     usr/src
```

The filesystem mounts can then be created using the techniques in this section. After doing that, the result is then something like (some lines omitted):

```bash
[root@basecm10 default-image]# cmsh
[basecm10]% category use default; fsmounts
[basecm10->category[default]->fsmounts]% list -f device:53,mountpoint:17
device                                              mountpoint (key)
--------------------------------------------------  -----------------
...                                                 ...
master:/cm/shared                                   /cm/shared
master:/home                                        /home
basecm10:/cm/images/default-image/usr/share/locale  /usr/share/locale
basecm10:/cm/images/default-image/usr/lib/jvm       /usr/lib/jvm
basecm10:/cm/images/default-image/usr/share/doc     /usr/share/doc
basecm10:/cm/images/default-image/usr/src           /usr/src
[basecm10->category[default]->fsmounts]%
```

Diskless nodes that have NFS subtree configuration carried out on them can be rebooted to start them up with the new configuration.

### 3.13.4  Configuring NFS Volume Exports And Mounts Over RDMA With OFED Drivers

If running NFS over RDMA, then at least NFS version 4.0 is recommended. NFS version 3 will also work with RDMA, but uses IPoIB encapsulation instead of native verbs. NFS version 4.1 uses the RDMA Connection Manager (`librdmacm`), instead of the InfiniBand Connection Manager (`ib_cm`) and is thereby also able to provide pNFS.

The administrator can set the version of NFS used by the cluster by setting the value of `Nfsvers` in the file `/etc/nfsmount.conf` on all the nodes, including the head node.

#### 3.13.4.1  Drivers To Use For NFS Over RDMA

BCM OFED drivers ([section 10 of the *Installation Manual*](/installation/nvidiamlnxofed)) can support using the RDMA protocol (section [3.6](#36-configuring-infiniband-interfaces)) to provide NFS. The BCM OFED driver from `mlnx-ofed23.04` (associated with April 2023) and later drivers support it. The BCM OFED driver LTS versions since that time also support it.

The DOCA OFED drivers and distribution OFED drivers also support NFS over RDMA.

When using NFS over RDMA, `ibnet`, the IP network used for InfiniBand, should be set. Section [3.6.3](#363-infiniband-network-settings) explains how that can be done.

#### 3.13.4.2  Exporting With Base View And `cmsh` Using NFS Over RDMA

With the drivers installed, a volume export can be carried out using NFS over RDMA.

The procedure using Base View is much the same as done in section [3.13.1](#3131-exporting-a-filesystem-using-base-view-and-cmsh) (“Exporting A Filesystem Using Base View”), except for that the `ibnet` network should be selected instead of the default `internalnet`, and the “`RDMA`” option should be enabled.

The procedure using `cmsh` is much the same as done in section [3.13.1](#3131-exporting-a-filesystem-using-base-view-and-cmsh) (“Exporting A Filesystem Using `cmsh`”), except that the `ibnet` network (normally with a recommended value of 10.149.0.0/16) should be set, and the `rdma` option should be set.

**Example**

(based on the example in section [3.13.1](#3131-exporting-a-filesystem-using-base-view-and-cmsh))

```bash
...
[...->fsexports*[Fluid Model Data*]]% set path /modeldata
[...[Fluid Model Data*]]% set hosts ibnet
[...[Fluid Model Data*]]% set rdma yes
[...[Fluid Model Data*]]% commit
...
```

#### 3.13.4.3  Mounting With Base View And `cmsh` Using NFS Over RDMA

The mounting of the exported filesystems using NFS over RDMA can then be done.

The procedure using Base View is largely like that in section [3.13.2.1](#31321-mounting-a-filesystem-using-base-view), (“Mounting A Filesystem Using Base View”), except that the `Device` entry must point to `master.ib.cluster` so that it resolves to the correct NFS server address for RDMA, and the checkbox for `NFS over RDMA` must be ticked.

The procedure using `cmsh` is similar to that in section [3.13.2.2](#31322-mounting-a-filesystem-using-cmsh), (“Mounting A Filesystem Using `cmsh`”), except that device must be mounted to the `ibnet`, and the `rdma` option must be set, as shown:

**Example**

(based on the example in section [3.13.2.2](#31322-mounting-a-filesystem-using-cmsh))

```bash
...
[basecm10->category[default]->fsmounts]% add /modeldatagpu
[basecm10->...*[/modeldatagpu*]]% set device basecm10.ib.cluster:/modeldata
[basecm10->...*[/modeldatagpu*]]% set filesystem nfs
[basecm10->...*[/modeldatagpu*]]% set rdma yes
[basecm10->category*[default*]->fsmounts*[/modeldatagpu*]]% commit
...
```

## 3.14  Managing And Configuring Services

### 3.14.1  Why Use The Cluster Manager For Services?

Linux administrators should be familiar with managing services from the command line using `systemctl`:

**Example**

```bash
        systemctl start <service~name>.service
```

where \<*service name*> indicates a service such as `mysqld`, `mariabd`, `nfs`, `postfix` and so on.

Services can also be managed with BCM. That is, they can also be started and stopped with Base View and `cmsh` tools.

An additional convenience that comes with the cluster manager tools is that some CMDaemon parameters useful for managing services in a cluster are very easily configured, whether on the head node, a regular node, or for a node category. These parameters are:

* `monitored`: checks periodically if a service is running. Information is displayed and logged the first time it starts or the first time it dies

* `autostart`: restarts a failed service that is being `monitored`.

  * If `autostart` is set to `on`, and a service is stopped using BCM, then no attempts are made to restart the service. Attempted autostarts become possible again only after BCM starts the service again.

  * If `autostart` is set to `on`, and if a service is removed using BCM, then the service is stopped before removal.

  * If `autostart` is `off`, then a service that has not been stopped by CMDaemon still undergoes an attempt to restart it, if

    * CMDaemon is restarted

    * its configuration files are updated by CMDaemon, for example in other modes, as in the example [here](#3232-adding-hostnames-to-the-internal-network).

* `runif`: (only honored for nodes used as part of a high availability configuration (chapter [17](/admin/ha))) whether the service should run with a state of:

  * `active`: run on the active node only

  * `passive`: run on the passive only

  * `always`: run both on the active and passive

  * `preferpassive`: preferentially run on the passive if it is available. Valid only for head nodes. Invalid for failover groups (section [17.5.3.3](/admin/ha#17533-setting-up-a-server-for-the-failover-group)).

The details of a service configuration remain part of the configuration methods of the service software itself.

* Thus BCM can run actions on typical services only at the generic service level to which all the unix services conform. This means that CMDaemon can run actions such as starting and stopping the service. If the restarting action is available in the script, then CMDaemon can also run that.

* The operating system configuration of the service itself, including its persistence on reboot, remains under control of the operating system, and is not handled by CMDaemon. So, stopping a service within CMDaemon means that by default the service may start up on reboot. Running

  `systemctl disable <`*service name>*`.service`

  from the command line can be used to configure the service to no longer start up on reboot.

BCM can be used to keep a service working across a failover event with an appropriate `runif` setting and appropriate failover scripts such as the `Prefailover script` and the `Postfailover script` (section [17.4.6.7](/admin/ha#17467-postfailover-script)). The details of how to do this will depend on the service.

### 3.14.2  Managing And Configuring Services—Examples

If, for example, the CUPS software is installed (“`yum install cups`”), then the CUPS service can be managed in several ways:

#### 3.14.2.1  Managing The Service From The Regular Shell, Outside Of CMDaemon

Standard unix commands from the bash prompt work, as shown by this session:

```bash
[root@basecm10 ~]# systemctl enable cups.service
...symlinks created...
[root@basecm10 ~]# systemctl start cups
```

#### 3.14.2.2  Managing The Service From `cmsh`

**Listing existing services managed by `cmsh`:** Services that are specifically managed by `cmsh` can be listed in `services` mode at `device` and `category` level. They mostly run on the head node. For example, on a standard BCM head node without workload managers or Kubernetes:

**Example**

```bash
[basecm10->device[basecm10]->services]% list
Service (key)            Monitored  Autostart
------------------------ ---------- ----------
conman                   yes        yes
dhcpd                    yes        yes
named                    yes        yes
nfs                      yes        yes
nslcd                    yes        yes
ntpd                     yes        yes
postfix                  yes        yes
shorewall                yes        yes
shorewall6               yes        yes
slapd                    yes        yes
```

These services are typically provided by BCM roles (section [2.1.5](/admin/clustermanagement#215-roles)). For example, assigning the `boot` role to a node means that it runs the `dhcpd` service, which allows the netbooting of nodes from that node.

The services not managed by BCM are not listed in `services` mode, until they are configured to be managed by BCM. For example, `cron` is not listed in `services` mode unless it is added to `services` mode.

**Adding and starting the service in `cmsh`:** The following session illustrates adding the CUPS service from within `device` mode and the `services` submode. The device in this case is a regular node, `node001`, but a head node can also be chosen. Monitoring and auto-starting are also set in the session (some lines elided):

```bash
[basecm10]% device services node001
[basecm10->device[node001]->services]% add cups
[basecm10->device*[node001*]->services*[cups*]]% show
Parameter                         Value
------------------------------    ------------------------
Autostart                         no
Belongs to role                   no
Monitored                         no
...
Run if                            ALWAYS
Service                           cups
...
[basecm10->device*[node001*]->services*[cups*]]% set monitored on
[basecm10->device*[node001*]->services*[cups*]]% set autostart on
[basecm10->device*[node001*]->services*[cups*]]% commit
[basecm10->device[node001]->services[cups]]%
Apr 14 14:02:16 2017 [notice] node001: Service cups was started
[basecm10->device[node001]->services[cups]]%
```

**Other service options in `cmsh`:**

Within `cmsh`, the `start`, `stop`, `restart`, and `reload` options to the

`service` \<*service name*>` start|stop|restart|...`

command can be used to manage the service at the `services` submode level. For example, continuing with the preceding session, stopping the CUPS service can be done by running the `cups` service command with the `stop` option as follows:

```bash
[basecm10->device[node001]->services[cups]]% stop
Fri Apr 14 14:03:40 2017 [notice] node001: Service cups was stopped
Successfully stopped service cups on: node001
[basecm10->device[node001]->services[cups]]%
```

The service is then in a `STOPPED` state according to the `status` command.

```bash
[basecm10->device[node001]->services[cups]]% status
cups                [STOPPED]
```

Details on how a state is used when monitoring a service are given in the section “Monitoring A Service With `cmsh` And Base View” [here](#31424-monitoring-a-service-with-cmsh-and-base-view).

Continuing from the preceding session, the CUPS service can also be added for a node category from `category` mode:

```bash
[basecm10->device[node001]->services[cups]]% category
[basecm10->category]% services default
[basecm10->category[default]->services]% add cups
```

As before, after adding the service, the monitoring and autostart parameters can be set for the service. Also as before, the options to the `service` \<*service name*>` start|stop|restart|...` command can be used to manage the service at the `services` submode level. The settings apply to the entire node category (some lines elided):

**Example**

```bash
[basecm10->category*[default*]->services*[cups*]]% show
...
[basecm10->category*[default*]->services*[cups*]]% set autostart yes
[basecm10->category*[default*]->services*[cups*]]% set monitored yes
[basecm10->category*[default*]->services*[cups*]]% commit
[basecm10->category[default]->services[cups]]%
Fri Apr 14 14:06:27 2017 [notice] node002: Service cups was started
Fri Apr 14 14:06:27 2017 [notice] node005: Service cups was started
Fri Apr 14 14:06:27 2017 [notice] node004: Service cups was started
Fri Apr 14 14:06:27 2017 [notice] node003: Service cups was started
[basecm10->category[default]->services[cups]]% status
node001.................. cups            [STOPPED ]
node002.................. cups            [   UP   ]
node003.................. cups            [   UP   ]
node004.................. cups            [   UP   ]
node005.................. cups            [   UP   ]
```

#### 3.14.2.3  Managing The Service From Base View

Using Base View, a service can be managed from an `OSServiceConfig list` window, accessible via the `Services` button from the `JUMP TO` section of the `Settings`. The window is accessible for

* `Head Nodes`, for example via a navigation path of\
  `Devices` > `Head Nodes[basecm10]` > `Settings` > `Services`

* `Nodes`, for example via a navigation path of\
  `Devices` > `Nodes[node001]` > `Settings` > `Services`\
  (figure [3.21](#fig-bright-view-service-node)):

![Operating system service configuration list window for nodes in Base View](/base-command-manager/product-manuals/_fern-img/d896ed85f13a37d2bb55eb0635fd4ae53884fa7bcdfcc33fb83553e60b013135.webp)

*Figure 3.21: Operating system service configuration list window for nodes in Base View*

* `Node categories`, for example via a navigation path of\
  `Grouping` > `Node categories[default]` > `Settings` > `Services`

By default, with the `default` software image, there are no services set at category level for nodes (figure [3.22](#fig-bright-view-service-cups-node-categories)):

![Operating system service configuration list window for the default category in Base View](/base-command-manager/product-manuals/_fern-img/f112da300eb63f8ccc13d2e72502759eaf270ef1ca021e49df4c7501ec9e8aee.webp)

*Figure 3.22: Operating system service configuration list window for the default category in Base View*

The `Service` \<*service name*>` start|stop|restart...` command options `start`, `stop`, `restart`, and so on, are displayed as selection options to an `OSService` popup that appears when the `ACTIONS` button is clicked (figure [3.23](#fig-bright-view-service-cups-node-categories-start-stop)):

![Operating system service actions in Base View](/base-command-manager/product-manuals/_fern-img/e7ff6c29cf236aba2e24100780e5ab86a82821ade6dce39390ec4d9d6fd1e61f.webp)

*Figure 3.23: Operating system service actions in Base View*

A service can be added with the `ADD` button, and clicking on the `OSServiceConfig` popup. The fields of the service can then be edited. The `REVERT` button reverts unsaved changes, while the `DELETE` button removes the saved changes.

Figure [3.24](#fig-bright-view-service-cups-add) shows CUPS being set up from an `Add` dialog in the services window. The window is accessible via the `ADD` button of figure [3.22](#fig-bright-view-service-cups-node-categories).

![Setting up a service using Base View](/base-command-manager/product-manuals/_fern-img/88323928d77bdf11f0ed57d94e499489c1f6c5f41373021bfe785572ec199344.webp)

*Figure 3.24: Setting up a service using Base View*

For a service in the services subwindow, clicking on the `Status` button in figure [3.22](#fig-bright-view-service-cups-node-categories) displays a grid of the state of services on a running node as either `Up` or `Down`.

#### 3.14.2.4  Monitoring A Service With `cmsh` And Base View

The service is in a `DOWN` state if it is not running, and in a `FAILING` state if it is unable to run after 10 auto-starts in a row. Event messages are sent during these first 10 auto-starts. After the first 10 auto-starts, no more event messages are sent, but autostart attempts continue.

In case an autostart attempt has not yet restarted the service, the `reset` option may be used to attempt an immediate restart. The `reset` option is not a service option in the regular shell, but is used by CMDaemon (within `cmsh` and Base View) to clear a `FAILING` state of a service, reset the attempted auto-starts count to zero, and attempt a restart of the service.

The monitoring system sets the `ManagedServicesOk`  health check (Appendix [G.2.1](/admin/metricshealthchecksactions#g21-regular-health-checks)) to a state of `FAIL` if any of the services it monitors is in the `FAILING` state. In `cmsh`, the statuses of the services are listed by running the `latesthealthdata` command (section [12.6.3](/admin/monitoring#1263-the-latest-data-and-counter-valuesthe-latestdata-and-latestmetriccounters-commands)) from `device` mode.

Standard init.d script behavior is that the script return a non-zero exit code if the service is down, and a zero exit code if the service is up. A non-zero exit code makes BCM decide that the service is down, and should be restarted.

However, some scripts return a non-zero exit code even if the service is up. These services therefore have BCM attempt to start them repetitively, even though they are actually running.

This behavior is normally best fixed by setting a zero exit code for when the service is up, and a non-zero exit code for when the service is down.

#### 3.14.2.5  Removing A Service From CMDaemon Control Without Shutting It Down

Removing a service from BCM control while `autostart` is set to `on` stops the service on the nodes:

```bash
[basecm10->category[default]->services]% add cups
[basecm10->category*[default*]->services*[cups*]]% set monitored on
[basecm10->category*[default*]->services*[cups*]]% set autostart on
[basecm10->category*[default*]->services*[cups*]]% commit; exit
[basecm10->category[default]->services]% remove cups; commit
Wed May 23 12:53:58 2012 [notice] node001: Service cups was stopped
```

In the preceding `cmsh` session, `cups` starts up when the `autostart` parameter is committed, if `cups` is not already up.

The behavior of having the service stop on removal is implemented because it is usually what is wanted.

However, sometimes the administrator would like to remove the service from CMDaemon control without it shutting down. To do this, `autostart` must be set to `off` first.

```bash
[basecm10->category[default]->services]% add cups
[basecm10->category*[default*]->services*[cups*]]% set monitored on
[basecm10->category*[default*]->services*[cups*]]% set autostart off
[basecm10->category*[default*]->services*[cups*]]% commit; exit
Wed May 23 12:54:40 2012 [notice] node001: Service cups was started
[basecm10->category[default]->services]% remove cups; commit
[basecm10->category[default]->services]% !# no change: cups stays up
```

## 3.15  Managing And Configuring A Rack

### 3.15.1  Racks

A cluster may have local nodes grouped physically into racks. A rack is 42 units in height by default, and nodes normally take up one unit.

#### 3.15.1.1  Rack List

**Rack list in Base View:** The `Rack list` pane can be opened up in Base View via the navigation path `Datacenter Infrastructure` > `Racks` (figure [3.25](#fig-bright-view-racks-overview)):

![Rack list using Base View](/base-command-manager/product-manuals/_fern-img/7f11c81b2c288fa8d9ae8473533251b5e43ae977fd3db25177c14f53962ded77.webp)

*Figure 3.25: Rack list using Base View*

Racks can then be added, removed, or edited from the pane.

Within the `Rack list` pane:

* a new rack item can be added with the `ADD` button, and then clicking on the `Rack` popup. This opens a `Settings` tab in the rack item window pane where rack configuration can be carried out and saved (figure [3.26](#fig-bright-view-racks-configuration-settings)).

* an existing rack item can be edited with the `Edit` menu option, or by double-clicking on the item itself. This also opens up the `Settings` tab in the rack item window pane where rack configuration can be managed.

**Racks overview in `cmsh`:** The `rack` mode in `cmsh` allows racks defined in the cluster manager to be listed:

```bash
[basecm10->rack]% list
Name (key)      Room           x-Coordinate   y-Coordinate   Height
--------------  -------------  -------------  -------------  ------
rack2           skonk works    2              0              42
racknroll                      1              0              42
```

#### 3.15.1.2  Rack Configuration Settings

**Rack configuration settings in Base View:** A `Settings` tab for editing a rack item selected from the `Rack list` pane is shown in figure [3.26](#fig-bright-view-racks-configuration-settings).

![Rack configuration settings using Base View](/base-command-manager/product-manuals/_fern-img/9542718f4b894adf19a529ee171647734f41546c33e68843bd086356c8c47890.webp)

*Figure 3.26: Rack configuration settings using Base View*

The rack item configuration settings are:

* `Name`: A unique name for the rack item. Names such as `rack001`, `rack002` are a sensible choice.

* `Room`: A unique name for the room the rack is in.

* `Position`: The *x*- and *y*-coordinates of the rack in a room.

  These coordinates are meant to be a hint for the administrator about the positioning of the racks in the room, and as such are optional, and can be arbitrary numbers. The `Notes` field can be used as a supplement or as an alternative for hints.

* `Height`: by default this is the standard rack size of 42U.

* `Inverted`: Normally, a rack uses the number 1 to mark the top and 42 to mark the bottom position for the places that a device can be positioned in a rack. However, some manufacturers invert this and use 1 to mark the bottom instead. Enabling the `Inverted` setting records the numbering layout accordingly for all racks, if the inverted rack is the first rack seen in `Rackview`.

**Rack configuration settings in `cmsh`:** In `cmsh`, tab-completion suggestions for the `set` command in `rack` mode display the racks available for configuration. On selecting a particular rack (for example, `rack2` as in the following example), tab-completion suggestions then display the configuration settings available for that rack:

**Example**

```bash
[basecm10->rack]% set rack
rack1  rack2  rack3
[basecm10->rack]% set rack2
height        name          revision      width         y-coordinate
inverted      notes         room          x-coordinate
```

The configuration settings for a particular rack obviously match with the parameters associated with and discussed in figure [3.26](#fig-bright-view-racks-configuration-settings).

Setting the values can be done as in this example:

**Example**

```bash
[basecm10->rack]% use rack2
[basecm10->rack[rack2]]% set room "skonk works"
[basecm10->rack*[rack2*]]% set x-coordinate 2
[basecm10->rack*[rack2*]]% set y-coordinate 0
[basecm10->rack*[rack2*]]% set inverted no
[basecm10->rack*[rack2*]]% commit
[basecm10->rack[rack2]]%
```

### 3.15.2  Assigning Devices To A Rack

Devices such as nodes, switches, and chassis, can be assigned to racks.

By default, no such devices are assigned to a rack.

Devices can be assigned to a particular rack and to a particular position within the rack as follows:

#### 3.15.2.1  Assigning Devices To A Rack Using Base View

Using Base View, a device such as a node `node001` can be assigned to a rack via the navigation path `Devices` > `Nodes[node001]` > `Settings` > `JUMP TO` > `Rack` (figure [3.27](#fig-bright-view-node-to-rack-assign)):

![Rack assignment using Base View](/base-command-manager/product-manuals/_fern-img/7eb809bbbf10f5a6ce152d147c4ed828a880c9ef0d2b85b886a8791386a81494.webp)

*Figure 3.27: Rack assignment using Base View*

#### 3.15.2.2  Assigning Devices To A Rack Using `cmsh`

Using `cmsh` in `device` mode, node assignment to an existing rack `rack2`, of:

* `node001` to position `1`

* `node002` to position `2`

* `node003` to position `3`

can conveniently be done as follows:

```bash
root@basecm10:~# for i in {001..003} ; do cmsh -c "device use node$i; get hostname; set rack rack2; \
get rack; set deviceposition $i; get deviceposition; commit"; done
```

#### 3.15.2.3  The Convention Of The Top Of The Device Being Its Position

Since rack manufacturers usually number their racks from top to bottom, the position of a device in a rack (using the parameter `Position` in Base View, and the parameter `deviceposition` in `cmsh`) is always taken to be where the top of the device is located. This is the convention followed even for the less usual case where the rack numbering is from bottom to top.

A position on a rack is 1U of space. Most devices have a height that fits in that 1U, so that the top of the device is located at the same position as the bottom of the device, and no confusion is possible. The administrator should however be aware that for any device that is greater than 1U in height such as, for example, a blade enclosure chassis (section [3.15.3](#3153-assigning-devices-to-a-chassis)), the convention means that it is the position of the top of the device that is where the device is considered to be. The position of the bottom of the device is ignored.

### 3.15.3  Assigning Devices To A Chassis

#### 3.15.3.1  A Chassis As A Physical Part Of A Cluster

In a cluster, several local nodes may be grouped together physically into a chassis. This is common for clusters using blade systems. Clusters made up of blade systems use less space, less hardware, and less electrical power than non-blade clusters with the same computing power. In blade systems, the blades are the nodes, and the chassis is the blade enclosure.

A blade enclosure chassis is typically 6 to 10U in size, and the node density for server blades is typically 2 blades per unit with 2014 technology.

#### 3.15.3.2  Chassis Configuration And Node Assignment

**Chassis list in Base View:** The `Chassis list` pane can be opened up in Base View via the navigation path\
`Datacenter Infrastructure` > `Chassis`\
or\
`Devices` > `Chassis`

A chassis can then be added, removed, or edited from the pane.

Within the `Chassis list` pane:

* a new chassis item can be added with the `ADD` button, and then clicking on the `Chassis` popup. This opens a `Chassis` pane where chassis configuration can be carried out and saved (figure [3.28](#fig-bright-view-chassis-subpane)).

* an existing chassis item can be edited with the `Edit` menu option, or by double-clicking on the item itself. This also opens up the `Chassis` pane for chassis configuration.

![Base View chassis configuration](/base-command-manager/product-manuals/_fern-img/920e2268e621b7d976da0805d30f35464a47b03f4a0274455c36f2be99828c97.webp)

*Figure 3.28: Base View chassis configuration*

The options that can be set within the `Chassis` pane include the following:

* `Hostname`: a name that can be assigned to the chassis operating system

* `Tag`: a hardware tag for the chassis

* `Mac`: the MAC address of the chassis

* `Model`: the hardware model name

* `Rack`: the rack in which the chassis is placed

* `Members`: the `Members` menu option allows devices to be assigned to a chassis (figure [3.29](#fig-bright-view-chassis-members)). An item within the `Device` set can be any item from the subsets of `Node`, `Switch`, `Power Distribution Unit`, `Generic Device`, `Rack Sensor`, and `Gpu Unit`. These items can be filtered for viewing, depending on whether they are `Assigned` (members of the chassis), `Not Assigned` (not members of the chassis), or they can `All` be viewed (both `Assigned` and `Not Assigned` items).

* `Layout`: how the nodes in a chassis are laid out visually.

* `Network`: which network the chassis is attached to.

* `Username`, `Password`: the user name and password to access the chassis operating system

* `Power control`, `Custom power script`, `Custom power script argument`: power-related items for the chassis.

* `Userdefined1`, `Userdefined2`: administrator-defined variables that can be used by CMDaemon.

![Base View Chassis Members Menu Options](/base-command-manager/product-manuals/_fern-img/03627308116fad026fd19af25512a85c615f26e945556d1c67dffbaba6b95e4f.webp)

*Figure 3.29: Base View Chassis Members Menu Options*

**Basic chassis configuration and node assignment with `cmsh`:**

The `chassis` mode in `cmsh` allows configuration related to a particular chassis. Tab-completion suggestions for a selected chassis with the `set` command show possible parameters that may be set:

**Example**

```bash
[basecm10->device[chassis1]]% set
containerindex             hostname                   partition                  switchports
custompingscript           ip                         password                   tag
custompingscriptargument   layout                     powercontrol               userdefined1
custompowerscript          mac                        powerdistributionunits     userdefined2
custompowerscriptargument  members                    rack                       userdefinedresources
defaultgateway             model                      revision                   username
deviceheight               network                    slots
deviceposition             notes                      supportsgnss
```

Whether the suggested parameters are actually supported depends on the chassis hardware. For example, if the chassis has no network interface of its own, then the `ip` and `mac` address settings may be set, but cannot function.

The positioning parameters of the chassis within an already-defined rack, `rack2`, can be set as follows with `cmsh`:

**Example**

```bash
[basecm10->device[chassis1]]% set rack rack2
[basecm10->device*[chassis1*]]% set deviceposition 1; set deviceheight 6
[basecm10->device*[chassis1*]]% commit
```

The members of the chassis can be set as follows with `cmsh`:

**Example**

```bash
[basecm10->device[chassis1]]% append members basecm10 node001..node005
[basecm10->device*[chassis1*]]% commit
```

## 3.16  Configuring GPU Settings

### 3.16.1  GPUs And GPU Units

GPUs (Graphics Processing Units) are processors that are heavily optimized for executing certain types of parallel processing tasks. GPUs were originally used for rendering graphics, and one GPU typically has hundreds of cores. When used for general processing, they are sometimes called General Processing GPUs, or GPGPUs. For convenience, the “GP” prefix for General Processing is not used in this manual.

A GPU is typically placed on a PCIe card. GPUs can be physically inside the node that uses them, or they can be physically external to the node that uses them. As far as the operating system on the node making use of the physically external GPUs is concerned, the GPUs are internal to the node.

If the GPUs are physically external to the node, then they are typically in a *GPU unit*. A GPU unit is a chassis that hosts only GPUs. It is typically able to provide GPU access to several nodes, usually via PCIe extender connections. This ability means that external GPUs typically require more configuration than internal GPUs. GPU units are not covered in this manual because they are not very popular due to their greater cost and slowness.

Configuring GPU settings for GPUs—that is, for devices internal to a node—is covered next.

### 3.16.2  Configuring GPU Settings

#### 3.16.2.1  The `gpusettings` Submode In `cmsh`

In `cmsh`, GPUs can be configured for a specified node via `device` mode.

Going into the `gpusettings` submode for that node then allows a type of GPU to be set, from the `amd` or `nvidia` types, and a range to be specified for the GPU slots for that particular node:

**Example**

```bash
[root@basecm10 ~]# cmsh
[basecm10]% device use node001
[basecm10->device[node001]]% gpusettings
[basecm10->device[node001]->gpusettings]% add nvidia 1-3 ; commit
```

The range can be specified as

* a single number, for a particular slot, for example: `3`

* a range, for a range of slots, for example: `0-2`

* all, for all GPU slots on that node, using:

  `   all`

  or

  `   *`

GPUs can also be configured for a specified category via `category` mode. For example, using the category `default`, then entering into the `gpusettings` submode allows a type (`nvidia` or `amd`) and a range to be set for the range of GPUs:

**Example**

```bash
[root@basecm10 ~]# cmsh
[basecm10]% category use default
[basecm10->category[default]]% gpusettings
[basecm10->category[default]->gpusettings]% list
GPU range (key)  Power limit  ECC mode     Compute mode  Clock speeds
---------------- ------------ ------------ ------------- -------------
[basecm10->category[default]->gpusettings]% add nvidia 1-3 ; commit
[basecm10->category[default]->gpusettings[nvidia:1-3]]% show
Parameter                      Value
------------------------------ ----------------------------------
Clock speeds
Clock sync boost mode
Compute mode
ECC mode
...
```

As usual, GPU settings for a node override those for a category (section [2.1.3](/admin/clustermanagement#213-node-categories)).

#### 3.16.2.2  GPU Settings With NVIDIA GPUs

The installation of the NVIDIA GPU software driver packages is covered [in section 9.1 of the *Installation Manual*](/installation/nvidiagpus#91-installing-cuda). It should be noted that the `cuda-dcgm` package must be installed to access NVIDIA GPU metrics.

The present section is about configuring NVIDIA GPUs in BCM. The driver itself does not necessarily have to be in place for the configuration to be done, although the configuration only becomes active when the driver is installed.

After a GPU type has been set, the following NVIDIA GPU settings may be specified, if supported, from within the `gpusettings` submode:

* `clockspeeds`: The pair of clock speeds (frequency in MHz) to be set for this parameter can be selected from the list of available speeds. The available speeds can be seen by running the `status` command. The values are specified in the form: \<*number for GPU processor*>,\<*number for memory*>

* `clocksyncboostmode`: GPU boosting. Exceed the maximum core and memory clock speeds if it is safe. Choices are:

  * `enabled`

  * `disabled`

* `computemode`: Contexts can be computed with the following values for this mode:

  * `Default`: Multiple contexts are allowed

  * `Exclusive thread`: Only one context is allowed per device, usable from one thread at a time

  * `Exclusive process`: Only one context is allowed per device, usable from multiple threads at a time. This mode option is valid for CUDA 4.0 and higher. Earlier CUDA versions ran only in this mode.

  * `Prohibited`: No contexts are allowed per device

* `eccmode`: Sets the ECC bit error check, with:

  * `enabled`

  * `disabled`

  When ECC is enabled:

  * Single bit errors are detected, using the `EccSBitGPU` metric ([here](/admin/metricshealthchecksactions#g11-regular-metrics)), and corrected automatically.

  * Double bit errors are also detected, using the `EccDBitGPU` metric ([here](/admin/metricshealthchecksactions#g11-regular-metrics)), but cannot be corrected.

* `GPU range`: range values can be set as follows:

  * `all`: The GPU settings apply to all GPUs on the node.

  * \<*number*>: The GPU settings apply to an individual GPU, for example: `1`

  * \<*number range*>: The GPU settings apply to a range of GPUs, for example: `1,3-5`

* `powerlimit`: The administrator-defined upper power limit for the GPU. Only valid if `powermode` is `Supported`.

  * `min`: The minimum upper power limit that the hardware supports.

  * `max`: The maximum upper power limit that the hardware supports.

  * \<*number*>: An arbitrary upper power limit, specified as a number between `min` and `max`

  * `default`: Upper power limit based on the default hardware value.

If no value is specified for a GPU setting, then the hardware default is used.

#### 3.16.2.3  The `updatenodegpuconfig` Command For Controlling Power Consumption

Above the `gpusettings` submode, within `device` mode, nodes with GPUs can have their power consumption limited per specified GPU:

Without arguments, the `updatenodegpuconfig` command shows the current status:

**Example**

```bash
[basecm10->device[node001]]% updatenodegpuconfig
Node         GPU          Power limit      Processor speed  Memory speed
------------ ------------ ---------------- ---------------- ----------------
node001      0            350 W            135 MHz          958 MHz
node001      1            350 W            135 MHz          958 MHz
```

In the preceding example, the only node with a GPU is node001. The same result is therefore shown if the command is run as `updatenodegpuconfig -n node001`.

The first and second GPUs on `node001` can have their power limits set to the same value with a range syntax:

```bash
[basecm10->device]% updatenodegpuconfig node001:0-1:330
Node         GPU          Power limit      Processor speed  Memory speed
------------ ------------ ---------------- ---------------- ----------------
node001      0            330 W            135 MHz          958 MHz
node001      1            330 W            135 MHz          958 MHz
```

For the first and second GPUs on `node001`, the power limit, in watts, can be set to different values:

**Example**

```bash
[basecm10->device]% updatenodegpuconfig node001:1:300 node001:0:330
Node         GPU          Power limit      Processor speed  Memory speed
------------ ------------ ---------------- ---------------- ----------------
node001      0            330 W            135 MHz          958 MHz
node001      1            300 W            135 MHz          958 MHz
```

A dry-run option shows the effect on both the GPUs:

```bash
[basecm10->device]% updatenodegpuconfig node001:0-1:350 --dry-run
Node         GPU          Power limit      Processor speed  Memory speed
------------ ------------ ---------------- ---------------- ----------------
node001      0            350 W            -                -
node001      1            350 W            -                -
```

The clock speed can be set with a 3rd colon delimited field, in Hz:

```bash
[basecm10->device]% updatenodegpuconfig node001:0:350:142M
Node         GPU          Power limit      Processor speed  Memory speed
------------ ------------ ---------------- ---------------- ----------------
node001      0            350 W            135 MHz          142 MHz
```

Using both `gpusettings` values and `updatenodegpuconfigs` may cause conflict. For example with the processor speed setting of `updatenodgpuconfig` and the value of `clockspeeds` in `gpusettings`.

If the clocks cannot be changed, then the driver is handling them dynamically.

#### 3.16.2.4  GPU Settings With AMD GPUs

GPU settings for AMD Radeon GPUs are accessed via `cmsh` in the same way as NVIDIA GPU settings. The AMD GPU setting parameters do differ from the NVIDIA ones.

The AMD GPUs supported are Radeon cards. A list of cards and operating systems compatible with the Linux driver used is at [https://support.amd.com/en-us/kb-articles/Pages/Radeon-Software-for-Linux-Release-Notes.aspx](https://support.amd.com/en-us/kb-articles/Pages/Radeon-Software-for-Linux-Release-Notes.aspx)

AMD GPU driver installation is described in [section 7.4 of the *Installation Manual*](/installation/thirdparty#74-amd-gpu-driver-installation).

The Radeon Instinct MI25 shows the following settings in Ubuntu 16_06 running a Linux 4.4.0-72-generic kernel:

**Example**

```bash
[basecm10->device[node001]->gpusettings]% list
Type GPU range Info
---- --------- ------------------
AMD  0         PowerPlay: manual
[basecm10->device[node001]->gpusettings]% use amd:0
[basecm10->device[node001]->gpusettings[amd:0]]% show
Parameter                        Value
-------------------------------- -----------------------------
Activity threshold               1
Fan speed                        255
GPU clock level                  5
GPU range                        0
Hysteresis down                  0
Hysteresis up                    0
Info                             PowerPlay: manual
Memory clock level               3
Minimum GPU clock                0
Minimum memory clock             0
Overdrive percentage             1
PowerPlay mode                   manual
Revision
Type                             AMD
```

The possible values here are:

* `activitythreshold`: Percent GPU usage at a clock level that is required before clock levels change. From 0 to 100.

* `fanspeed`: Maximum fan speed. From 0 to 255

* `gpuclocklevel`: GPU clock level setting. From 0 to 7.

* `gpurange`: The slots used.

* `hysteresisdown`: Delay in milliseconds before a clock level decrease is carried out.

* `hysteresisup`: Delay in milliseconds before a clock level increase is carried out.

* `info`: A compact informative line about the GPU status.

* `memoryclocklevel`: Memory clock speed setting. From 0-3. Other cards can show other values.

* `minimumgpuclock`: Minimum clock frequency for GPU, in MHz. The kernel only allows certain values. Supported values can be seen using the `status` command.

* `minimummemoryclock`: Minimum clock frequency for the memory, in MHz. The kernel only allows certain values. Supported values can be seen using the status command.

* `overdrivepercentage`: Percent overclocking. From 0 to 20%

* `powerplaymode`: Decides how the performance level power setting should be implemented.

  * `high`: keep performance high, regardless of GPU workload

  * `low`: keep performance low, regardless of GPU workload

  * `auto`: Switch clock rates according to GPU workload

  * `manual`: Use the memory clock level and GPU clock values.

The `status` command displays supported clock frequencies (some values ellipsized):

**Example**

```bash
[basecm10->device[node001]->gpusettings[amd:0]]% status
Index Name                  Property     Value        Supported
----- --------------------- ------------ ------------ -------------------------------------
0     Radeon Instinct MI25  Clock        1399Mhz      852Mhz, 991Mhz, ..., 1440Mhz, 1515Mhz
0     Radeon Instinct MI25  Memory       945Mhz       167Mhz, 500Mhz, 800Mhz, 945Mhz
```

#### 3.16.2.5  GPU Settings In Base View

In Base View, `GPU settings` can be accessed within the settings options for a category or a device. This brings up a GPU settings list.

**GPU settings list in Base View:** A `GPU Settings list` pane can be opened up in Base View for a regular node, for example `node001`, with the navigation path:\
`Devices` > `Nodes[node001]` > `Edit` > `Settings` > `JUMP TO` > `GPU Settings`

Similarly, a `GPU Settings list` pane can be opened up in Base View for nodes in a category, for example `gpunodes`, with the navigation path:\
`Grouping` > `Categories[gpunodes]` > `Edit` > `Settings` > `JUMP TO` > `GPU Settings`

Within the `GPU Settings list` pane:

* a new GPU settings item can be added with the `ADD` button, and then clicking on either the `AMDGPUSettings` or the `NVIDIAGPUSettings` item in the popup. This opens an `AMDGPU Settings` pane or an `NVIDIA GPU Settings` pane, where GPU configuration can be carried out and saved (figure [3.30](#fig-bright-view-nodes-gpusettings)).

![GPU settings window for a node](/base-command-manager/product-manuals/_fern-img/a66a46d2a7692f05b7cae5656c49bbb377bf0c3e3d49e9d30fc00c91b5f4ddaa.webp)

*Figure 3.30: GPU settings window for a node*

* an existing GPU settings item can be edited with the `Edit` menu option, or by double-clicking on the item itself. This also opens up the GPU Settings pane where GPU configuration can be managed.

#### 3.16.2.6  GPU Configuration For HPC Workload Managers

**Slurm GPU configuration via direct `slurm.conf` changes:** To configure NVIDIA GPUs for Slurm, changes are made in `slurm.conf` when `cm-wlm-setup` configures GPUs for Slurm (section [7.3](/admin/workloadmanagement#73-installation-of-workload-managers)).

Changes made are kept in the `AUTOGENERATED` section and can be worked out by checking the difference between the `slurm.conf.template` file and the actual `slurm.conf` file. Changes made include defining the GresTypes `gpu` and `mps`, and setting GPU plugins that allow Slurm generic resources to work.

The configured gres options can be seen by running `sbatch --gres=help`:

**Example**

```bash
[fred@basecm10 ~]$ sbatch --gres=help
Valid gres options are:
gpu[[:type]:count]
mps[[:type]:count]
```

This means that a GPU can be requested in a job script with the Slurm gres option:

```bash
#SBATCH --gres=gpu:1
```

Similarly, MPS resources ([https://slurm.schedmd.com/gres.html#MPS_Management](https://slurm.schedmd.com/gres.html#MPS_Management)) can be requested with:

```bash
#SBATCH --gres=mps:100
```

If adding new parameters manually, care must be taken to avoid duplication of parameters already in the file, because `slurmd` is unlikely to work properly with duplicated parameters.

The Slurm client role can be configured at configuration overlay, category, or node level. If configuring the Slurm client role for GPU gres resources manually, then each GPU can be configured within the role:

**Example**

```bash
[basecm10->configurationoverlay]% list
Name (key)           Priority   All head nodes Nodes            Categories       Roles
-------------------- ---------- -------------- ---------------- ---------------- ----------------
slurm-accounting     500        yes                                              slurmaccounting
slurm-client         500        no                              default          slurmclient
slurm-server         500        yes                                              slurmserver
slurm-submit         500        no                              default          slurmsubmit
wlm-headnode-submit  600        yes                                              slurmsubmit
[basecm10->configurationoverlay]% use slurm-client
[basecm10->configurationoverlay[slurm-client]]% roles
[basecm10->configurationoverlay[slurm-client]->roles]% use slurmclient
[basecm10->configurationoverlay[slurm-client]->roles[slurmclient]]% genericresources
[basecm10->configurationoverlay[slurm-client]->roles[slurmclient]->genericresources]%
[basecm10->...->roles[slurmclient]->genericresources]% add gpu0
[basecm10->...->roles*[slurmclient*]->genericresources*[gpu0*]]% set name gpu
[basecm10->...->roles*[slurmclient*]->genericresources*[gpu0*]]% set file /dev/nvidia0
[basecm10->...->roles*[slurmclient*]->genericresources*[gpu0*]]% commit
[basecm10->...->roles[slurmclient]->genericresources[gpu0]]%
    (Repeat similar settings for the other GPUs, gpu1...gpu7)
[basecm10->...->roles[slurmclient]->genericresources]% list
  Alias (key) Name     Type     Count    File
  ----------- -------- -------- -------- ----------------
  gpu0        gpu                        /dev/nvidia0
  gpu1        gpu                        /dev/nvidia1
  gpu2        gpu                        /dev/nvidia2
  gpu3        gpu                        /dev/nvidia3
  gpu4        gpu                        /dev/nvidia4
  gpu5        gpu                        /dev/nvidia5
  gpu6        gpu                        /dev/nvidia6
  gpu7        gpu                        /dev/nvidia7
[basecm10->configurationoverlay[slurm-client]->roles[slurmclient]->genericresources]%
```

By default, Slurm just allows a single job to be executed per node. To change this behavior, it is necessary to allow oversubscription. For example, to allow 8 jobs per node:

**Example**

```bash
[basecm10->wlm[slurm]]% jobqueue
[basecm10->wlm[slurm]->jobqueue]% use defq
[basecm10->wlm[slurm]->jobqueue[defq]]% set oversubscribe yes:8
[basecm10->wlm[slurm]->jobqueue*[defq*]]% commit
[basecm10->wlm[slurm]->jobqueue[defq]]%
```

**Slurm GPU configuration via auto-detection:** Instead of carrying out Slurm configuration by modifying `slurm.conf` by hand, it may be configured via auto-detection. More details on this are to be found starting at [here](/admin/workloadmanagement#slurmautodetection).

**PBS:** NVIDIA Base Command Manager version 9.0 onward supports GPU configuration in PBS via the `cm-wlm-setup` tool after installation (section [7.3.2](/admin/workloadmanagement#732-running-cm-wlm-setup-as-a-tui)).

**Grid Engine:** GPU configuration is carried out as follows:

1. **Grid Engine cgroups parameter modifications for GPU devices (obsolete)**\
   In NVIDIA Base Command Manager 8.0, 8.1, and 8.2: The command `qconf -mconf` \<*hostname*> is used to add GPU device(s) to the `cgroups_params` parameter for the host.

   For example, if `node001` has access to 8 GPUs, then running the command `qconf -mconf node001` on the head node may initially show a configuration such as:

   ```bash
   hostname                    node001
   cgroups_params              cgroup_path=/sys/fs/cgroup cpuset=true \
                               mount=false freezer=true freeze_pe_tasks=true \
                               killing=false forced_numa=false \
                               h_vmem_limit=false m_mem_free_hard=false \
                               m_mem_free_soft=false min_memory_limit=0
   ```

   The GPU devices can then be appended to the end of the last line and saved, so that the last line becomes:

   **Example**

   ```bash
                               m_mem_free_soft=false min_memory_limit=0 devices=/dev/nvidia[0-7]
   ```

   The parameter can be made persistent by setting the `AdvancedConfig` directive ([here](/admin/cmdconf#c80-advancedconfig-directive)) to include the setting `UGEDisableCgroupSettings=1` and restarting CMDaemon.

2. **GPU devices configuration in `ugeclient` role (current)**\
   In NVIDIA Base Command Manager 9.0: setting the `AdvancedConfig` directive ([here](/admin/cmdconf#c80-advancedconfig-directive)) to include the setting `UGEDisableCgroupSettings=1` is not needed. This is because the `qconf -mconf` configuration method is not required.

   Instead, NVIDIA Base Command Manager 9.0 introduces specification of the GPU devices via the `devices` parameter for the `ugeclient` role:

   **Example**

   ```bash
   [basecm10->category[dgx]->roles[ugeclient]]% set gpus 8
   [basecm10->category*[dgx*]->roles*[ugeclient*]]% set gpudevices gpu0[device=/dev/nvidia0,cuda_id=0]
   [basecm10->category*[dgx*]->roles*[ugeclient*]]% append gpudevices gpu1[device=/dev/nvidia1,cuda_id=1]
   [basecm10->category*[dgx*]->roles*[ugeclient*]]% append gpudevices gpu2[device=/dev/nvidia2,cuda_id=2]
   [basecm10->category*[dgx*]->roles*[ugeclient*]]% append gpudevices gpu3[device=/dev/nvidia3,cuda_id=3]
   [basecm10->category*[dgx*]->roles*[ugeclient*]]% append gpudevices gpu4[device=/dev/nvidia4,cuda_id=4]
   [basecm10->category*[dgx*]->roles*[ugeclient*]]% append gpudevices gpu5[device=/dev/nvidia5,cuda_id=5]
   [basecm10->category*[dgx*]->roles*[ugeclient*]]% append gpudevices gpu6[device=/dev/nvidia6,cuda_id=6]
   [basecm10->category*[dgx*]->roles*[ugeclient*]]% append gpudevices gpu7[device=/dev/nvidia7,cuda_id=7]
   [basecm10->category*[dgx*]->roles*[ugeclient*]]% commit
   [basecm10->category[dgx]->roles[ugeclient]]%.
   ```

3. **GE port configuration for DCGM**\
   The DCGM port should be set correctly.

   In NVIDIA Base Command Manager versions prior to 9.0, it can be changed from its default with the command `qconf -mconf`. The format for the setting is:

   **Example**

   ```bash
       execd_params UGE_DCGM_PORT=<port>
   ```

   The default value for \<*port*> is `5555`.

   From NVIDIA Base Command Manager 9.0 onward, setting the DCGM port for GE is a configuration option in the CMDaemon front ends.

**LSF:** Within LSF cluster configuration, GPU devices can be autodetected by setting the `gpuautoconfig` parameter to `yes`. In `cmsh` this can be carried out with:

**Example**

```bash
[basecm10->wlm[lsf]]% set gpuautoconfig yes
[basecm10->wlm*[lsf*]]%
```

The parameter can also be set during LSF configuration via `cm-wlm-setup` (figure [3.31](#fig-cm-wlm-setup-ncurses-lsf-gpu-settings)):

![GPU settings screen for LSF in cm-wlm-setup](/base-command-manager/product-manuals/_fern-img/02498070534a937fcbc4df3c9ccf63fb664038b0fb54df180f919c98a4472a72.webp)

*Figure 3.31: GPU settings screen for LSF in cm-wlm-setup*

GPU resource enforcement can be configured for LSF as follows:

**Example**

```bash
[basecm10->wlm[lsf]->cgroups]% append resourceenforce gpu
[basecm10->wlm*[lsf*]->cgroups*]% commit
[basecm10->wlm[lsf]->cgroups]%
```

### 3.16.3  MIG Configuration

MIG configuration can be carried out for the cluster using the BCM MIG management as described in this section.

An alternative for MIG configuration is to not use the BCM MIG management tool (`cmsh`), and to instead use other MIG management tools, such as the DGX native `nvidia-migmanager.service`, or the GPU operator-provided `nvidia-mig-manager`. If non-BCM MIG management tools are used, then BCM leaves the MIG configuration alone. Using multiple MIG management tools simultaneously to configure MIG should not be done.

#### 3.16.3.1  What Is MIG?

An Ampere NVIDIA GPU is a GPU based on the GA100 microarchitecture. It has compute capability 8.0, which means it can be configured into multiple logical GPU instances if it uses CUDA 11 and NVIDIA driver 450.80.02 or later.

This configuration of multiple logical GPU instances is called Multi-Instance GPU (MIG). The logical GPU instances are MIG devices, that are enabled by setting up the physical GPU to switch to MIG mode.

**As a sanity check to see if MIG is supported:** If the hardware and drivers are in place, then running the `nvidia-smi` command on the node with the physical GPU should display its MIG capability:

```bash
root@basecm10:~# ssh node001 "nvidia-smi" | grep MIG
|                               |                      |               MIG M. |
| MIG devices:                                                                |
| GPU  GI  CI  MIG |         Memory-Usage |        Vol|         Shared        |
```

**GPU utilization information changes on enabling MIG:** Once enabled, the full physical GPU is no longer available as a device, and GPU utilization metrics become unavailable by default.

GPU profiling metrics (section [G.1.7](/admin/metricshealthchecksactions#g17-gpu-profiling-metrics)) for the physical GPU can however still be enabled. For example, it can be carried out with `cmsh` as follows, for a GPU on `node001`:

**Example**

```bash
basecm10->device[node001]]% gpuprofiling show
Hostname    GPU      Major ID     Minor ID     Field ID     Metric                         Watched
----------- -------- ------------ ------------ ------------ ------------------------------ ----------
node001     0        0            1            1002         gpu_profiling_sm_active        no
node001     0        0            1            1003         gpu_profiling_sm_occupancy     no
...
basecm10->device[node001]]% gpuprofiling watch 1003
Hostname    GPU      Major ID     Minor ID     Field ID     Metric                         Watched
----------- -------- ------------ ------------ ------------ ------------------------------ ----------
...
node001     0        0            1            1003         gpu_profiling_sm_occupancy     yes
...

[basecm10->device[node001]]% metrics | grep gpu_profiling
Metric  gpu_profiling_sm_occupancy       gpu0                     GPU       GPUSampler
```

Enabling physical GPU profiling after MIG enablement should be done with caution, because:

* it may affect the performance

* newer drivers may support MIG profiling, which may be confusing

#### 3.16.3.2  Overview Of MIG Concepts And Terminology

The logical GPU instances are composed of *slices* of GPU resources. Slices are the smallest fraction possible of the resource that can be allocated in a logical GPU instance. Thus:

* memory slice: this is the smallest fraction of the memory of the physical GPU that can be allocated to the GPU instance. For the Ampere architecture this is 1/8(th) of the total physical GPU memory.

* SM slice: this is the smallest fraction of the streaming multiprocessors (SMs) on the GPU that can be allocated as a logical SM. An SM is composed of multiple cores (streaming processors). For the Ampere architecture an SM slice is 1/7(th) of the total physical GPU SMs.

* GPU slice: this is the smallest fraction of the physical GPU that has a single GPU memory slice and a single GPU SM slice. A maximum of 7 GPU slices can be specified from the original physical GPU.

The preceding fractional slices can be combined in various mixes to compose a logical `GPU instance`:

* GPU instance: a combination of GPU slices and GPU engines. GPU engines are hardware components that execute other work on the GPU, and can be encoders/decoders (NVENCs/NVDECs), shortcut connectors (CE (copy engine) for DMA), etc.

* compute instance: a part of a GPU instance. It consists of a subset of the parent GPU instance’s SM slices and other GPU engines (DMAs, NVENCs ...). The compute instances can share memory and GPU engines with other compute instances within their GPU instance.

Further details on the terminology and how slices can be allocated to GPU instances are given in the NVIDIA documentation at [https://docs.nvidia.com/datacenter/tesla/mig-user-guide/#concepts](https://docs.nvidia.com/datacenter/tesla/mig-user-guide/#concepts).

A use case for creating several GPU instances from a full physical GPU is when allocation of the full physical GPU is wasteful.

For example, if a full physical GPU is allocated to a job, but the job only uses a fraction of the full set of GPU cores, then the allocation is wasteful, because no other job can then be processed on the remaining idle cores. Instead, if the physical GPU is split into several instances and the job allocated to an instance with a closer match in resources, then it means that other GPU instances are still available for processing other jobs.

When configuring GPU instances for the cluster, the administrator typically allocates all available slices to all the GPU instances that are being configured. Leaving a slice unallocated means that that slice cannot be available to jobs, and it means that the physical resources of that slice are lying idle. For example, if some of the 7 SM slices from the physical GPU are not used, then they are wasted as their processors are never available to jobs, and so that slice stays idle.

Cluster management of GPU instances is described in the following sections.

#### 3.16.3.3  MIG Status Of Physical GPUs

The MIG status on a GPU can be viewed with the `mig status` command. For example, the following shows 8 physical GPUs on `node001` that have not yet become MIG enabled:

**Example**

```bash
[basecm10->device[node001]]% mig status
Node             GPU      Active                           Pending
---------------- -------- -------------------------------- --------------------------------
node001          0        no                               no
node001          1        no                               no
node001          2        no                               no
node001          3        no                               no
node001          4        no                               no
node001          5        no                               no
node001          6        no                               no
node001          7        no                               no
```

#### 3.16.3.4  MIG `enable` And `disable` Options To Set Up Pending States For The Physical GPUs

If the `enable` or `disable` options are run, then by default all the physical GPUs are set to a pending state for enabled (`yes`) and disabled (`no`) respectively:

**Example**

```bash
[basecm10->device[node001]]% mig enable
Node             GPU      Active                           Pending
---------------- -------- -------------------------------- --------------------------------
node001          0        no                               yes
node001          1        no                               yes
node001          2        no                               yes
node001          3        no                               yes
node001          4        no                               yes
node001          5        no                               yes
node001          6        no                               yes
node001          7        no                               yes
```

Individual physical GPUs can also be set to a pending state of enabled or disabled, following the node list syntax (section [2.5.5.10](/admin/clustermanagement#25510-node-list-syntax)):

```bash
[basecm10->device[node001]]% mig disable 3,5-7
Node             GPU      Active                           Pending
---------------- -------- -------------------------------- --------------------------------
node001          0        no                               yes
node001          1        no                               yes
node001          2        no                               yes
node001          3        no                               no
node001          4        no                               yes
node001          5        no                               no
node001          6        no                               no
node001          7        no                               no
```

#### 3.16.3.5  Rebooting The MIG Instances To Activate/Deactivate Instances According To Pending State Settings

The pending states only become active after the node is rebooted for A100 GPUs:

**Example**

```bash
[basecm10->device[node001]]% reboot
Reboot in progress for: node001
...
node001 [   UP   ]
[basecm10->device[node001]]% mig status

Node             GPU      Active                           Pending
---------------- -------- -------------------------------- --------------------------------
node001          0        yes                              yes
node001          1        yes                              yes
node001          2        yes                              yes
node001          3        no                               no
node001          4        yes                              yes
node001          5        no                               no
node001          6        no                               no
node001          7        no                               no
```

The effect of `enable` and `disable` persists after reboots, until the pending value changes once more.

For H100 GPUs, the changes do not require a reboot.

#### 3.16.3.6  The MIG Profiles

**Listing MIG Profiles:** The full list of the existing available MIG profiles for each physical GPU is displayed with the `mig profiles` command for the node. If there are 7 physical GPUs at the node, then the listing might look something like:

**Example**

```bash
[basecm10->device[node001]]% mig profiles
Node             GPU      ID       Name       Instances Memory
---------------- -------- -------- ---------- --------- --------
node001          0        1        1g.5gb     7         4.7GiB
node001          0        1        1g.5gb+me  1         4.7GiB
node001          0        2        2g.10gb    3         9.7GiB
node001          0        3        3g.20gb    1         19.6GiB
node001          0        4        4g.20gb    1         19.6GiB
node001          0        7        7g.40gb    1         39GiB
...
node001          7        2        2g.10gb    3         9.7GiB
node001          7        3        3g.20gb    1         19.6GiB
node001          7        4        4g.20gb    1         19.6GiB
node001          7        7        7g.40gb    1         39GiB
```

A list for physical GPU 1 can be displayed with:

**Example**

```bash
[basecm10->device[node001]]% mig profiles 1
Node             GPU      ID       Name       Instances Memory
---------------- -------- -------- ---------- --------- --------
node001          1        1        1g.5gb     7         4.7GiB
node001          1        1        1g.5gb+me  1         4.7GiB
node001          1        2        2g.10gb    3         9.7GiB
node001          1        3        3g.20gb    1         19.6GiB
node001          1        4        4g.20gb    1         19.6GiB
node001          1        7        7g.40gb    1         39GiB
```

**MIG Profiles Naming Convention:** The naming format for the profile takes the form

\<*number of GPU slices in the physical GPU*>`g.<`*memory for slice in GB*>gb

The `+me` suffix implies media extensions being active. The number of GPU instances, the number of GPU slices used, and the memory used by the instance can thus be worked out from the name.

For example:

* `1g.5gb` implies that the size of the GPU slice used for the instances is 1. 4.7GiB of memory is used by each of the 7 GPU instances,

* `2g.10gb` implies that the size of the GPU slice used for the instances is 2. 9.7GiB of memory is used by each of the 3 GPU instances.

**Creating GPU instances, by setting the MIG profile for a GPU:** The MIG profile is an attribute that can be set within the GPU settings for its physical GPU. This can be done after having set up a CMDaemon entity for a physical GPU 0 (section [3.16.2](#3162-configuring-gpu-settings)):

**Example**

```bash
[basecm10->device[node001]]% gpusettings
[basecm10->device*[node001]->gpusettings]% list
Type   GPU range Info
------ --------- --------
Nvidia 0         default
[basecm10->device[node001]->gpusettings]% use nvidia:0
[basecm10->device[node001]->gpusettings[nvidia:0]]% show
Parameter                        Value
-------------------------------- ------------------------------------------------
...
MIG profiles
```

* **A simple existing set of profiles** with 7 GPU instances with 1 GPU slice each, and 5 GB of memory for each slice can be specified with:

  **Example**

  ```bash
  [basecm10->device[node001]->gpusettings[nvidia:0]]% set migprofiles 1g.5gb; commit
  [basecm10->device[node001]->gpusettings[nvidia:0]]% show
  Parameter                        Value
  -------------------------------- ------------------------------------------------
  ...
  MIG profiles                     1g.5gb
  ```

  Setting the profiles, and carrying out the `commit` configures the GPU instances, but does not yet apply them:

  **Example**

  ```bash
  [basecm10->device[node001]->gpusettings[nvidia:0]]% ..;..
  [basecm10->device[node001]]% mig show
  Node             GPU      MIG      Instance Name     Profile  Start    Size
  ---------------- -------- -------- -------- -------- -------- -------- --------
  ```

  Applying the profile deploys the configuration, and shows the configuration:

  **Example**

  ```bash
  [basecm10->device[node001]]% mig apply
  Node             GPU      MIG      Instance Name     Profile  Start    Size
  ---------------- -------- -------- -------- -------- -------- -------- --------
  node001          0        13       -        1g.5gb   19       6        1
  node001          0        13       0        1g.5gb   0        0        1
  ```

  In the preceding, 1 GPU instance has been deployed, with 1 compute instance slice using 5GB. The instance with the `-` represents the hosting GPU instance, while the subsequent row represents the compute instance.

* **Setting a profile with `mig apply --profile`** is an alternative to setting it within `gpusettings`. However, only a profile set within `gpusettings` is persistent. The profile set with the `--profile` option is lost if its node reboots. Multiple profiles can be set using comma-separation (instead of using space-separation). Using multiple `--profile` options is also possible.

  **Example**

  ```bash
  [basecm10->device[node001]]% mig apply --profile 1g.5gb,2g.10gb
  Node             GPU      MIG      Instance Name     Profile  Start    Size
  ---------------- -------- -------- -------- -------- -------- -------- --------
  node001           0        5        -        2g.10gb  14       4        2
  node001           0        5        0        2g.10gb  1        0        2
  node001           0        13       -        1g.5gb   19       6        1
  node001           0        13       0        1g.5gb   0        0        1
  [basecm10->device[node001]]% mig apply --profile 1g.5gb --profile 2g.10gb
  Node             GPU      MIG      Instance Name     Profile  Start    Size
  ---------------- -------- -------- -------- -------- -------- -------- --------
  node001           0        5        -        2g.10gb  14       4        2
  node001           0        5        0        2g.10gb  1        0        2
  node001           0        13       -        1g.5gb   19       6        1
  node001           0        13       0        1g.5gb   0        0        1
  ```

* **Multiple GPU instances** can be specified, if the GPU allows it, using a \<*number*>`*` prefix syntax. So, to deploy 7 GPU instances, each hosting 1 compute instance with 5gb slices, the specification can be:

  **Example**

  ```bash
  [basecm10->device[node001]]% gpusettings; use nvidia:0
  [basecm10->device[node001]->gpusettings[nvidia:0]]% set migprofiles 7*1g.5gb; commit
  [basecm10->device[node001]->gpusettings[nvidia:0]]% ..;..
  [basecm10->device[node001]]% mig apply
  Node            GPU      MIG      Instance Name     Profile  Start    Size
  --------------- -------- -------- -------- -------- -------- -------- --------
  node001         0        7        -        1g.5gb   19       0        1
  node001         0        7        0        1g.5gb   0        0        1
  node001         0        8        -        1g.5gb   19       1        1
  node001         0        8        0        1g.5gb   0        0        1
  node001         0        9        -        1g.5gb   19       2        1
  node001         0        9        0        1g.5gb   0        0        1
  node001         0        10       0        1g.5gb   19       3        1
  node001         0        10       0        1g.5gb   0        0        1
  node001         0        11       -        1g.5gb   19       4        1
  node001         0        11       0        1g.5gb   0        0        1
  node001         0        12       -        1g.5gb   19       5        1
  node001         0        12       0        1g.5gb   0        0        1
  node001         0        13       -        1g.5gb   19       6        1
  node001         0        13       0        1g.5gb   0        0        1
  ```

* **GPU slices** can be implied by default by the profile, and subsets of these slices can be specified explicitly.

  To deploy 1 GPU instance, with 7 GPU slices of compute instance resources, the specification can be:

  **Example**

  ```bash
  [basecm10->device[node001]]% gpusettings; use nvidia:0
  [basecm10->device[node001]->gpusettings[nvidia:0]]% set migprofiles 7g.40gb; commit
  [basecm10->device[node001]->gpusettings[nvidia:0]]% ..;..
  [basecm10->device[node001]]% mig apply
  Node             GPU      MIG      Instance Name     Profile  Start    Size
  ---------------- -------- -------- -------- -------- -------- -------- --------
  node001          0        0        -        7g.40gb  0        0        8
  node001          0        0        0        7g.40gb  4        0        7
  ```

  If a profile with a more than 1 GPU slice is chosen, then GPU slice subsets can be set up via the following syntax:

  **Example**

  ```bash
  [basecm10->device[node001]]% gpusettings; use nvidia:0
  [basecm10->device[node001]->gpusettings[nvidia:0]]% set migprofiles 2g.10gb; commit
  [basecm10->device[node001]->gpusettings[nvidia:0]]% ..;..
  [basecm10->device[node001]]% mig apply
  Node             GPU      MIG      Instance Name     Profile  Start    Size
  ---------------- -------- -------- -------- -------- -------- -------- --------
  node001          0        5        -        2g.10gb  14       4        2
  node001          0        5        0        2g.10gb  1        0        2
  ```

* **GPU slices use a colon syntax** to explicitly specify subsets of GPU slices.

  The configuration specification `2g.10gb` can also be specified as `2g.10gb:1`, where that `:1` indicates the number of GPU slices for the compute instance, counting from zero. That means the compute instance has 2 GPU slices. The resulting configuration is exactly the same as `2g.10g`.

  If the specification `2g.10gb:0` is used instead, then the compute instance ends up looking like:

  **Example**

  ```bash
  [basecm10->device[node001]]% gpusettings; use nvidia:0
  [basecm10->device[node001]->gpusettings[nvidia:0]]% set migprofiles 2g.10gb:0; commit
  [basecm10->device[node001]->gpusettings[nvidia:0]]% ..;..
  [basecm10->device[node001]]% mig apply
  Node             GPU      MIG      Instance Name        Profile  Start    Size
  ---------------- -------- -------- -------- ----------- -------- -------- --------
  node001          0        5        -        2g.10gb     14       4        2
  node001          0        5        0        1c.2g.10gb  0        0        1
  ```

  Here the `1c` indicates 1 GPU slice (here it is counting from 1).

  Adding another slice to a separate compute instance within the same GPU instance can be specified with:

  **Example**

  ```bash
  [basecm10->device[node001]]% gpusettings; use nvidia:0
  [basecm10->device[node001]->gpusettings[nvidia:0]]% set migprofiles 2g.10gb:0:0; commit
  [basecm10->device[node001]->gpusettings[nvidia:0]]% ..;..
  [basecm10->device[node001]]% mig apply
  Node             GPU      MIG      Instance Name        Profile  Start    Size
  ---------------- -------- -------- -------- ----------- -------- -------- --------
  node001          0        5        -        2g.10gb     14       4        2
  node001          0        5        0        1c.2g.10gb  0        0        1
  node001          0        5        1        1c.2g.10gb  0        1        1
  ```

  In the preceding `set migprofiles` command, the specification

  `2g.10gb:0:0`

  can alternatively be expanded out and written in the form:

  `2g.10gb:1c.2g.10gb:1c.2g.10gb`

  for more clarity, at the expense of more typing.

  For a general profile that allows N GPU slices for an instance (with N ≤ 7), the mapping for the colon syntax takes the form:

  | **compact colon form** | **expanded form**                  |
  | :--------------------- | :--------------------------------- |
  | `:0`                   | `1c.` \<*profile*>                 |
  | `:1`                   | `2c.` \<*profile*>                 |
  | ...                    | ...                                |
  | `:N-1`                 | `Nc.` \<*profile*> or \<*profile*> |

  In practice, there are hardware-based restrictions for what is permitted to be allocated. So for example on the NVIDIA A100-PCIE-40GB:

  `7g.40gb:3` is allowed but

  `7g.40gb:4` is not.

  Details on supported profiles for hardware can be found in the NVIDIA documentation. For example, for the A30 profiles at:

  [https://docs.nvidia.com/datacenter/tesla/mig-user-guide/#a30-profiles](https://docs.nvidia.com/datacenter/tesla/mig-user-guide/#a30-profiles)

  and for the A100 profiles at:

  [https://docs.nvidia.com/datacenter/tesla/mig-user-guide/#a100-profiles](https://docs.nvidia.com/datacenter/tesla/mig-user-guide/#a100-profiles).

  Increasing the number of GPU instances can also still be done using the earlier \<*number*>`*` prefix syntax together with the colon syntax, if the GPU allows it:

  **Example**

  ```bash
  [basecm10->device[node001]]% gpusettings; use nvidia:0
  [basecm10->device[node001]->gpusettings[nvidia:0]]% set migprofiles 3*2g.10gb:0:0; commit
  [basecm10->device[node001]->gpusettings[nvidia:0]]% ..;..
  [basecm10->device[node001]]% mig apply
  Node             GPU      MIG      Instance Name        Profile  Start    Size
  ---------------- -------- -------- -------- ----------- -------- -------- --------
  node001          0        3        -        2g.10gb     14       0        2
  node001          0        3        0        1c.2g.10gb  0        0        1
  node001          0        3        1        1c.2g.10gb  0        1        1
  node001          0        4        -        2g.10gb     14       2        2
  node001          0        4        0        1c.2g.10gb  0        0        1
  node001          0        4        1        1c.2g.10gb  0        1        1
  node001          0        5        -        2g.10gb     14       4        2
  node001          0        5        0        1c.2g.10gb  0        0        1
  node001          0        5        1        1c.2g.10gb  0        1        1
  ```

* **A heterogeneous set of existing profiles** for GPU instances can also be defined for the GPU with MIG profiles.

  For example, 2 instances with the MIG profile `1g.5gb`, and 1 instance with the MIG profile `2g.10gb` can be specified with:

  ```bash
  [basecm10->device[node001]]% gpusettings; use nvidia:0
  [basecm10->device[node001]->gpusettings[nvidia:0]]% set migprofiles 2*1g.5gb 2g.10gb; commit
  [basecm10->device[node001]->gpusettings[nvidia:0]]% show
  Parameter                        Value
  -------------------------------- ------------------------------------------------
  ...
  MIG profiles                     2*1g.5gb,2g.10gb
  [basecm10->device[node001]->gpusettings[nvidia:0]]% ..;..
  [basecm10->device*[node001*]]% mig apply
  Node             GPU      MIG      Instance Name     Profile  Start    Size
  ---------------- -------- -------- -------- -------- -------- -------- --------
  node001         0        3        -        2g.10gb  14       0        2
  node001         0        3        0        2g.10gb  1        0        2
  node001         0        11       -        1g.5gb   19       4        1
  node001         0        11       0        1g.5gb   0        0        1
  node001         0        13       -        1g.5gb   19       6        1
  node001         0        13       0        1g.5gb   0        0        1
  ```

* **heterogeneous sets are useful when trying to use up all the slices available**, to make the maximum resources available. So, while an administrator can carry out the preceding specification:

  `2*1g.5gb 2g.10gb`

  this is not a good allocation of resources since it only makes 4/7 of the GPU slices available, and 4/8 of the memory slices available. An administrator would more sensibly specify something like, for example:

  `5*1g.5gb,2g.10gb`

  which uses up the full 7 GPU slices and 35GB (6/8 slices) of memory available from the physical GPU. This makes full use of the SM resources derived from the physical GPU, so that these SM resources are fully available to workloads.

* **Overallocating slices for MIG configuration is not possible**. If there is an attempt to overallocate, then the slices that are allocated too late are simply not allocated. This can lead to unexpected results for the unwary cluster administrator. For example:

  * `5*1g.5gb,2g.10gb` allocates the 5 slices of the 1g instance and the 2 slices of the 2g instance.

    But

  * `6*1g.5gb,2g.10gb` allocates the 6 slices of the 1g instance and none of the 2g instance.

  * `7*1g.5gb,2g.10gb` allocates the 7 slices of the 1g instance and none of the 2g instance.

  * `70*1g.5gb,2g.10gb` allocates 7 slices of the 1g instance and none of the 2g instance.

## 3.17  Configuring Sampling From A Prometheus Exporter

CMDaemon can be configured to sample a Prometheus exporter, for example from the NVIDIA Unified Fabric Manager (UFM) platform. A CMDaemon front end such as `cmsh` can have a data producer, for example `UFM`, configured within the `monitoring setup` mode (section [12.5.4](/admin/monitoring#1254-the-setup-submode)) to allow sampling of the Prometheus exporter:

**Example**

```bash
[root@basecm10]# cmsh
[basecm10]% monitoring setup
[basecm10->monitoring->setup]% add prometheus UFM        #create a data producer of type Prometheus
[basecm10->monitoring->setup*[UFM*]]% set urls http://10.180.217.170:9001/metrics     #end point
[basecm10->monitoring->setup*[UFM*]]% set -e NoPostAllowed yes   #HTTP GET only, use for older exporters
[basecm10->monitoring->setup*[UFM*]]% nodeexecutionfilters
[basecm10->monitoring->setup*[UFM*]->nodeexecutionfilters]% active   #run on active head node only
Added active resource filter
[basecm10->monitoring->setup*[UFM*]->nodeexecutionfilters]% commit
```

In the example, the URL needs to be set to the Prometheus export server endpoint. The value of `NoPostAllowed` only needs to be set to `yes` for some older Prometheus versions that do not work with HTTP POST. The data producer is set to run on only the active head node with the `nodeexecutionfilter` setting ([here](/admin/monitoring#12545-the-setup-submode-deeper-submodes)).

The preceding example configures CMDaemon to sample from a Prometheus exporter. The other way around, that is to have CMDaemon be the exporter of Prometheus data, can be achieved via the `EnablePrometheusExporterService` directive ([here](/admin/cmdconf#c43-enableprometheusexporterservice-directive)).

## 3.18  Configuring Custom Scripts

Some scripts are used for custom purposes. These are used as replacements for certain default scripts, for example, in the case of non-standard hardware where the default script does not do what is expected. The custom scripts that can be set, along with their associated arguments are:

* `custompowerscript` and `custompowerscriptargument` (section [4.1.4](/admin/power#414-custom-power-control))

* `custompingscript` and `custompingscriptargument` (section [3.18.2](#3182-custompingscript))

* `customremoteconsolescript` and `customremoteconsolescriptargument` (section [3.18.3](#3183-customremoteconsolescript))

In addition to the preceding `custom*` scripts, system information scripts can be set that provide extra information to the `sysinfo` command in BCM (section [3.18.4](#3184-sysinfo-custom-scripts)).

The environment variables of CMDaemon ([section 3.3.1 of the *Developer Manual*](/developer/monitoring-actions#331-standard-environment-variables-available-in-action-scripts)) can be used in the scripts. Successful scripts, as is the norm, return 0 on exit.

### 3.18.1  `custompowerscript`

The use of custom power scripts is described in section [4.1.4](/admin/power#414-custom-power-control).

### 3.18.2  `custompingscript`

The following example script:

**Example**

```bash
#!/bin/bash
/bin/ping -c1 $CMD_IP
```

can be defined and set for the cases where the default built-in ping script, cannot be used.

By default, the node device states are detected by the built-in ping script (section [5.5](/admin/provisioning#55-node-states)) using ICMP ping. This results in the statuses that can be seen on running the list command of `cmsh` in device mode. An example output, formatted for convenience, is:

**Example**

```bash
[root@basecm10]# cmsh -c "device; format hostname:15, status:15; list"
hostname (key)  status
--------------- --------------
basecm10        [   UP   ]
node001         [   UP   ]
node002         [   UP   ]
```

If some device is added to the cluster that blocks such pings, then the built-in ping can be replaced by the custom ping of the example, which relies on standard ICMP ping.

However, the replacement custom ping script need not actually use a variety of ping at all. It could be a script running web commands to query a chassis controller, asking if all its devices are up. The script simply has to provide an exit status compatible with expected ping behavior. Thus an exit status of 0 means all the devices are indeed up.

### 3.18.3  `customremoteconsolescript`

A custom remote console script can be used to run in the built-in remote console utility. This might be used, for example, to allow the administrator remote console access through a proprietary KVM switch client.

For example, a user may want to run a KVM console access script that is on the head node and with an absolute path on the head node of `/root/kvmaccesshack`. The script is to run on the console, and intended to be used for node `node001`, and takes the argument `1`. This can then be set in `cmsh` as follows:

**Example**

```bash
[root@basecm10]# cmsh
[basecm10]% device use node001
[basecm10->device[node001]]% get customremoteconsolescript; get customremoteconsolescriptargument

[basecm10->device[node001]]% set customremoteconsolescript /root/kvmaccesshack
[basecm10->device[node001]]% set customremoteconsolescriptargument 1
[basecm10->device[node001]]% rconsole
        KVM console access session using the 1 argument option is displayed
```

In Base View, the corresponding navigation paths to access these script settings are:\
`Devices` > `Nodes` > `Edit` > `Settings` > `Custom remote console script`\
and\
`Devices` > `Nodes` > `Edit` > `Settings` > `Custom remote console script argument`\
while the remote console can be launched via the navigation path:\
`Devices` > `Nodes` > `Edit` > `Connect` > `Remote console`

### 3.18.4  `sysinfo` Custom Scripts

#### 3.18.4.1  Standard `sysinfo`

The `sysinfo` command in BCM is run from `device` mode in `cmsh` for a node. By default, `sysinfo` returns some basic hardware information for the node.

#### 3.18.4.2  Overview Of Running Custom Scripts In `sysinfo`

A cluster administrator may however wish to extract some additional hardware-related information from the cluster. To do this, custom scripts associated with the `sysinfo` command can be created by the cluster administrator. These `sysinfo` custom scripts run when the `sysinfo` command is executed via `cmsh`, and they pick up the additional information.

**Custom script types:** The scripts can be of three types, with corresponding directory locations. as indicated by the following table:

<table>
  <colgroup>
    <col />

    <col />
  </colgroup>

  <thead>
    <tr>
      <th>
        **Type of script**
      </th>

      <th>
        **Script directory path on node**
      </th>
    </tr>
  </thead>

  <tbody>
    <tr>
      <td>
        local
      </td>

      <td>
        `/cm/local/apps/cmd/scripts/sysinfo/local/`
      </td>
    </tr>

    <tr>
      <td>
        director
      </td>

      <td>
        `/cm/local/apps/cmd/scripts/sysinfo/director/`
      </td>
    </tr>

    <tr>
      <td>
        head
      </td>

      <td>
        `/cm/local/apps/cmd/scripts/sysinfo/head/`
      </td>
    </tr>
  </tbody>
</table>

**Custom script process:** When `sysinfo` runs for a particular node, the scripts that are called have the following characteristics, and are run as follows:

* Any scripts of the local type are run on the node that `sysinfo` is executed on. The scripts must be placed by the cluster administrator on the node itself. The node could be a head node, director node, a regular node, or a cloud node. The output from the local scripts is picked up.

* Any scripts of the director type are run on the director node. The scripts must be placed by the cluster administrator on the director node itself. The output from the scripts is picked up.

* Any scripts of the head type are run on the head node. The scripts themselves must be placed by the cluster administrator on the head node. The output from the scripts is picked up.

**Custom script output format:** The script outputs are JSON format key value pairs (JSON object literals).

The simplest standard JSON output form supported for `sysinfo` is:

```bash
{
 "key":"value"
}
```

The format if getting output for N key-value pairs is:

```bash
{
 "key1":"value1",
 "key2":"value2",
      ...
 "keyN":"valueN"
}
```

**Nested sysinfo output:** The key-value pairs can also be grouped, with the output presented in the following format for a group:

```bash
{
 "group":{
          "key1":"value1",
          "key2":"value2",
               ...
          "keyN":"valueN"
          }
}
```

The key-value pairs can also be structured with multiple groups. In the following example there are two groups:

**Example**

```bash
{
 "group1":{
          "key1.1":"value1.1",
          "key1.2":"value1.2"
          }
 "group2":{
          "key2.1":"value2.1",
          "key2.2":"value2.2",
          "key2.3":"value2.3"
          }
}
```

The nested multilayer output format can be useful for grouped values. For example, `dmidecode` can output key-value pairs that specify starting and ending ranges, which can be grouped according to the various DMI types that are also available in the output.

**Simple `sysinfo` custom script construction:** For example, the following `bash` script can be run on the head node:

**Example**

```bash
[root@basecm10 ~]# cat /cm/local/apps/cmd/scripts/sysinfo/head/outputscript.sh
#!/bin/bash
myhostname=$(hostname)
#next line extracts just the UUID value from the dmidecode output for the system for this particular hardware
myuuid=$(dmidecode | grep -A6 "^System Information" | grep UUID | sed -e 's/^\W*UUID: //')
echo '{'
echo '"script path is":"'$0'",'
echo '"CMDaemon running on":"'$CMD_HOSTNAME'",'
echo '"script running on":"'$myhostname'"',
echo '"'$myhostname' UUID":"'$myuuid'"'
echo '}'
```

If run directly, outside of CMDaemon, then this would display a JSON key-value output similar to the following:

**Example**

```bash
[root@basecm10 ~]# /cm/local/apps/cmd/scripts/sysinfo/head/outputscript.sh
{
    "script path is":"/cm/local/apps/cmd/scripts/sysinfo/head/outputscript.sh",
    "CMDaemon running on":"",
    "script running on":"basecm10",
    "basecm10 UUID":"6733d33a-2933-41ea-aa3c-b218e784c8b9"
}
```

**Custom script placement—overview for placing on a regular node:** Placing this head script on a regular node can be done by copying the script into a local directory on the node image, and rebooting the regular node so that it picks up the image with the new local type script. After CMDaemon is updated with the new `sysinfo` information, then, whenever `sysinfo` is run, the script is automatically run by CMDaemon.

#### 3.18.4.3  Examples Of Running Custom Scripts In `sysinfo`

The following example session makes the preceding concepts more explicit: the script is copied over from the head node to the default image of a regular node. It goes into the directory location for custom `sysinfo` scripts of the local type. Rebooting a node then installs the new script on the node:

**Example**

```bash
[root@basecm10 ~]# cp -r /cm/local/apps/cmd/scripts/sysinfo/head/outputscript.sh \
 /cm/images/default-image/cm/local/apps/cmd/scripts/sysinfo/local/
[root@basecm10 ~]# cmsh
[basecm10]% device
[basecm10->device]% reboot node001
         [the reboot of the node has to complete]
```

To update `cmdaemon` with the values from the new scripts for the node, the `--update` option to the `sysinfo` command can be run for the node. Running `sysinfo` for the node then displays the output of the scripts for the node. The `sysinfo` output value for `Age` shows how long it has been since CMDaemon was updated by the scripts for the node:

**Example**

```bash
[basecm10->device]% sysinfo node001 --update
[basecm10->device]% sysinfo node001
...

Age                          11s
CMDaemon running on          node001
script running on            node001                                                    local script
node001 UUID                 3b1c7973-07ef-419f-9324-4edf999690d5
script path is               /cm/local/apps/cmd/scripts/sysinfo/local/outputscript.sh
CMDaemon running on          node001
script running on            basecm10                                                   head script
basecm10 UUID                6733d33a-2933-41ea-aa3c-b218e784c8b9
script path is               /cm/local/apps/cmd/scripts/sysinfo/head/outputscript.sh
```

In the preceding example, the grouping braces are not part of the actual output. They are just part of this explanation, and show that the first four lines after the `Age` line are from the local type script running on node001. The four lines after that are from the head type script running on head, even though its corresponding CMDaemon is running on `node001`.

#### 3.18.4.4  Considerations Before Running Custom Scripts With `sysinfo`

Although BCM gives the administrator the freedom to construct all kinds of custom `sysinfo` scripts, some caution is urged before implementing the scripts. The following issues should at least be considered:

* The scripts should be speedy. The scripts run asynchronously, but a script is expected to take less than 15 seconds to run.

* The data output should be small. JSON objects allow, for example, that megabyte-sized text could be output by the sysinfo scripts. However, this is often unwise, given the nature of clusters. A cluster with a 1000 nodes and 1MB blobs would mean that 1GB of memory is being moved around.

## 3.19  Configuring Composable Infrastructure

### 3.19.1  Why Use Composable Infrastructure?

Composable infrastructure is infrastructure that is made up of hardware resources, designed at a hardware level to be *composed* (built up) by software.

To understand why composable infrastructure is useful in a cluster, it is helpful to first consider the issues with using non-composable infrastructure in a cluster.

#### 3.19.1.1  Non-composable Infrastructure Issues

For any cluster, composable or non-composable, a cluster administrator wants to optimize the use of the budget allocated for the cluster. To do this, the cluster administrator would typically try to minimize resources, such as storage, memory, networking, or GPUs, going unused.

In a traditional, non-composable, cluster, resources are often spread non-uniformly throughout the cluster infrastructure, and often optimized around particular nodes. For such a cluster, the cluster administrator therefore usually inventorizes the hardware resources, and organizes the resources in some way. For example, in BCM the cluster administrator may organize nodes:

* with categories (section [2.1.3](/admin/clustermanagement#213-node-categories)). For example, there might be a category of nodes with 4 GPUs.

* with node groups (section [2.1.4](/admin/clustermanagement#214-node-groups)). For example, there might be a group of nodes to be used by the Aeronautics Department.

* according to their storage properties (could be a category or a group). For example, nodes having large amounts of storage.

* according to their connection properties (could be a category or a group). For example, nodes in a particular room with InfiniBand for extra bandwidth.

The allocation of resources is then planned out for users and groups of users according to need. As needs change, the original plan may need to be modified, and resources reallocated.

Reallocation of resources at the software level is usually not an issue. For example, in the case of the Space Force Department getting allocated some nodes that were originally allocated to the Aeronautics Department—that can simply be done with re-categorization.

However, it often turns out that the optimal way to reorganize the resources in the cluster also requires reorganizing the underlying physical hardware, and knowing exactly what resources are associated with the underlying nodes. For example, the Space Force Department might need several GPUs, but the node given to them by the Aeronautics Department only has one, while the Aeronautics Department keeps the only other GPU node, which has 4 GPUs, because it has a huge amount of storage. Eventually, the problem is fixed by opening up the Aeronautics Department node, and moving some GPU cards and hard drives over to the Space Force Department node. This is also not usually much of an issue, if it happens once.

The trouble is, that cluster hardware can get reorganized periodically. Also, in general, if physical hardware changes are done regularly to nodes during reorganization, then it can make a cluster harder to manage over time (figure [3.32](#fig-composable-spaghetti)):

![An example of hardware configuration that may be hard to manage](/base-command-manager/product-manuals/_fern-img/65019586f2c5a97026489ba21abffb3b66f08992b3ba44dc004f79475a97239d.webp)

*Figure 3.32: An example of hardware configuration that may be hard to manage*

Because of the understandable reluctance by cluster administrators to carry out hardware reorganization and reallocation, resource use on a traditional cluster has a tendency to become less efficient over time. That is, the needs of the users change, but the physical resource allocation has a tendency to remain static, and as a result, users over time may find that their performance needs are no longer met by the original infrastructure.

#### 3.19.1.2  How Is Composable Infrastructure An Improvement On Non-composable Infrastructure?

**Resource allocation from a common pool:** In a cluster that uses composable infrastructure, resource allocation is dealt with by putting all the resources into a common pool. Typically the hardware for the pool is specialized, with, for example, storage provided by uniform, dedicated storage nodes, and GPUs provided by uniform, dedicated nodes with GPUs.

When resources are needed, they are allocated from the common pool. This is convenient because the cluster administrator no longer has to think as much about the physical infrastructure underlying the cluster. Each resource has been abstracted away from the underlying hardware, and placed into the pool for that type of resource, so that the resource is now fungible.

The abstraction means that resources composition can transcend the conventional physical limits. For example, if there are 8 GPU cards on the cluster, then even if there is no machine with 8 physical slots to accept GPU cards, the 8 GPUs can still be used by one job running on a machine that has requested the use of 8 GPU resources from the common pool.

**Resource communication:** Having each resource in a common pool may be convenient, but there may be a concern about the performance of the underlying hardware when a connection is made to use that resource. A pooled resource might be expected to have a communication penalty associated with it.

The usual way that composable infrastructure deals with hardware communication is by providing a high performance fabric connectivity hardware (cabling and switches) to bypass traditional TCP/IP networking. The dedicated fabric reduces CPU load, reduces latency, and allows a higher bandwidth. Among the fabric technologies in use for composable infrastructure are InfiniBand, PCIe, and Gen-Z.

In composable infrastructure, the composable resources and their interconnects are thus composable. This means that, to meet the needs of users, instead of requiring the cluster administrator to physically carry out re-cabling and move hardware components around as is the case with non-composable infrastructure, it is possible to reorganize the composable resources of the cluster virtually via BCM.

### 3.19.2  GigaIO Composable Infrastructure

BCM supports the GigaIO infrastructure components. GigaIO uses a PCIe fabric technology, FabreX, as the interconnect for the transport layer hardware and protocol.

#### 3.19.2.1  GigaIO Composable Infrastructure Components

The following hardware components are part of a GigaIO-based composable infrastructure:

* Resource boxes: Containers with GPUs, storage, or other resources that connect via PCIe.

* Nodes: Nodes that have PCIe extender cards placed in them to connect to the PCIe fabric.

* Fabric switches: Dedicated switches that use PCIe interconnects to connect to the resource boxes and to the nodes

* Fiber links: PCIe fiber interconnects used from the fabric switches, going to the resource boxes, to the nodes, or to other switches.

### 3.19.3  BCM Composable Infrastructure Integration Concepts

BCM integration of composable infrastructure uses the following concepts:

* A *binding* connects resources to host nodes, and is allocated by the cluster administrator. Bindings are virtual—the software representation is only concerned with the end points, and not the physical communication path.

* A *link* in a switch represents the cable between two switches that links the switches. The link can be:

  * a cascade link, which is part of the path from a node to a resource box,

  * a cross link, which is part of the path from one node to another node for computational needs

  * an NT link (non-transparent link), which is part of the path used for communicating node-to-node without exposing the data that each node accesses in its resources.

  * In composable infrastructure terminology in general, each link has two ends. If the connection is a node-to-resource cascade link, then one link end, the DSP (DownStream Port) end, connects to the USP (UpStream Port) of the switch. The other end of the link is then the USP for the DSP of the switch. The directions, up and down, indicated by the labels, have nothing to do with actual direction of packet data flow, which is bidirectional. The label is just associated with ownership, and based on the node port(s) of the switch being the USP end, and the resource port(s) of the switch being the DSP end.

    In the case of nodes that simply rely on fast interconnects to each other via switches, and do not have a resource box destination, both ends of the link are designated as USP.

* A *zone* can be thought of as being like a TCP/IP subnet. Just like for TCP/IP subnets, the transport layer packets that run over PCIe can be organized by the switch into separate zones, for speed and security. The packets from one zone are dealt with in their zone only, and only nodes and resources that are in the same zone can have a binding between them.

  * The *NTZone* (Non-Transparent Zone) is a special zone for node-to-node communication, effectively crossing zones for the nodes, but with the zone communications (which are transparent within a zone) still remaining inaccessible to other zones.

* A *topology* is how the physical interconnects are laid out across the nodes, switches, and resource boxes. Topologies are only available from a predefined selection. After selecting the topology, the bindings are defined on top of the topology by the cluster administrator, to complete the fabric configuration.

  For example, a topology with one node, one switch, and one resource box, would have no links, would have one or more USPs on the node side of the switch, and would have one or more DSPs on the resource side the switch. Setting a complete node-to-resource binding path in this example, would require a binding from the node to a USP on the switch, and another binding from the DSP on the switch to the resource box. This example is described more fully .

* A *fabric* is a configuration made up of a particular topology and binding. At a hardware level it is composed of a topology of fabric switches and resource boxes. There can be several fabrics in a cluster.

### 3.19.4  Standing Up A BCM Cluster With The GigaIO Fabric

This section covers the steps for standing up a BCM cluster with GigaIO composable infrastructure. The steps are:

1. **Cable as per required toplogy:** Once the devices have been installed in the rack(s), all devices must be cabled to match the desired topology.

2. **Install the head node:** The head node is installed using a BCM ISO based on CentOS 7 or Ubuntu 20.04. At the time of writing of this section (June 2022), CentOS 7 and Ubuntu 20.04 are the only validated Linux distributions.

3. **Define fabric switches**: Once the head node has an UP status, and is running, then the fabric switches can be defined using Base View or `cmsh`. The mininum required configuration is the hostname, IP address, username and password.

4. **Define nodes (hosts):** Using Base View or `cmsh`, nodes are defined that should be part of the composable infrastructure fabric.

5. **Define resource boxes:** Using Base View or `cmsh`, resource boxes are defined that comprise resources to be used for composing nodes (hosts).

6. **Power on the fabric switches:** The fabric switches that are used in managing the composability of resources are powered on.

7. **Configure topology:** The desired topology is configured in BCM and the settings are propagated to the switches. To do that:

   * Set fabric switches: The relevant switches defined in step 3 are selected.

   * Set hosts : The relevant hosts defined in step 4 are selected.

   * Set resource boxes : The resource boxes defined in step 5 are selected.

   * Apply topology : The desired topology changes are propagated to the fabric switches.

8. **Create GigaIO software image:** A software image is created that includes the GigaIO host software stack using the `cm-create-gigaio-image` tool. The software image is assigned to the appropriate nodes or node categories.

   **GigaIO host software stack installation:**  For the GigaIO composable infrastructure management to work, the nodes to which resources can be allocated must run the GigaIO FabreX host software stack. The FabreX software stack includes a custom kernel and additional utilities. The software stack must be installed into the software image used by the nodes.

   BCM provides a utility called `cm-create-gigaio-image` that allows users to install the FabreX software stack into a target software image, and also sets the correct kernel version for the software image.

   The FabreX sofware stack must be obtained via GigaIO support. It is usually provided as a commpressed tar archive. The path to the archive is passed an argument to `cm-create-gigaio-image` as the source of packages. An alternative is to specify a directory to where the archive has already been extracted.

   The help text for `cm-create-gigaio-image` is:

   ```bash
   [root@gigaio ~]# cm-create-gigaio-image  -h
   usage: cm-create-gigaio-image [-h] [--clonefrom CLONEFROM] [--verbose] packages targetimage

   Create gigaio software image

   positional arguments:
     packages              Path to directory or archive containing gigaio packages
     targetimage           Name of target software image

   optional arguments:
     -h, --help            show this help message and exit
     --clonefrom CLONEFROM
                           Name of software image to clone from
     --verbose             Enable verbose logging
   ```

   Some example of its use follow:

   1\. The FabreX software stack can be installed from the specified compressed archive to an already-existing image `giga-image-v25-r4`, with:

   ```bash
   cm-create-gigaio-image --verbose /root/FabreX_v2.5.0r4_CentOS7.tar.bz2 gigaio-image-v25-r4
   ```

   For an Ubuntu 20.04 distribution, the package is `FabreX_v2.5.0r4_Ubuntu20.tar.bz2`.

   2\. The image `default-image` is cloned to the target image `gigaio-image-v25-r4`, installed with the FabreX software stack from the specified directory, and the correct kernel version for the target image is set, with:

   ```bash
   export IGNORE_POST_INSTALL_FAILURES=1
   cm-create-gigaio-image --clonefrom default-image \
   /root/FabreX_v2.5.0r4_CentOS7 gigaio-image-v25-r4
   ```

   The `IGNORE_POST_INSTALL_FAILURES` environment variable is necessary at the time of writing (June 2022), because not all GigaIO packages currently install cleanly into a software image. This flag is expected to be not needed in a future version, probably v2.6.

9. **Boot nodes:** After the new image has been created, nodes can be set to use the GigaIO software image:

   **Example**

   ```bash
   root@gigaio2:~# cmsh
   [basecm10]% category use default
   [basecm10->category[default]]% set softwareimage gigaio-image-v25-r4
   [basecm10->category*[default*]]% commit
   [basecm10->category[default]]% device power reset -c default
   drac0 .................... [  RESET  ] node001
   drac0 .................... [  RESET  ] node002
   drac0 .................... [  RESET  ] node003
   drac0 .................... [  RESET  ] node004
   ```

10. **Verify that the nodes are part of the fabric:** The `fabrex-status.sh` utility can be used to check the status of the fabric connectivity and ensure that the host is part of the composable infrastructure. An example that runs the check on all compute nodes follows:

    ```bash
    [root@gigaio ~]# pdsh -g computenode "fabrex-status.sh | grep -A 3 PNUM"
    node004:    PNUM  STATE  PCCS  LLINK  POLL  PSTATE  PLINK  EPOCH  FLID        PEER ID
    node004:       0  rdy    cfg   up     slow  rdy     up         1  0x00000001  node001
    node004:       1  rdy    cfg   up     slow  rdy     up         1  0x00000002  node002
    node004:       2  rdy    cfg   up     slow  rdy     up         1  0x00000003  node003
    node002:    PNUM  STATE  PCCS  LLINK  POLL  PSTATE  PLINK  EPOCH  FLID        PEER ID
    node002:       0  rdy    cfg   up     slow  rdy     up         1  0x00000001  node001
    node002:       1  rdy    cfg   up     slow  rdy     up         1  0x00000003  node003
    node002:       2  rdy    cfg   up     slow  rdy     up         1  0x00000004  node004
    node001:    PNUM  STATE  PCCS  LLINK  POLL  PSTATE  PLINK  EPOCH  FLID        PEER ID
    node001:       0  rdy    cfg   up     slow  rdy     up         1  0x00000003  node003
    node001:       1  rdy    cfg   up     slow  rdy     up         1  0x00000004  node004
    node001:       2  rdy    cfg   up     slow  rdy     up         1  0x00000002  node002
    node003:    PNUM  STATE  PCCS  LLINK  POLL  PSTATE  PLINK  EPOCH  FLID        PEER ID
    node003:       0  rdy    cfg   up     slow  rdy     up         1  0x00000001  node001
    node003:       1  rdy    cfg   up     slow  rdy     up         1  0x00000002  node002
    node003:       2  rdy    cfg   up     slow  rdy     up         1  0x00000004  node004
    ```

#### 3.19.4.1  Setting Up The Fabric Switches And Resource Boxes In Composable Infrastructure As BCM Objects

In BCM, the fabric switches and resource boxes of composable infrastructure can be added via the `add` command ([here](/admin/clustermanagement#2532-working-with-objects-add-commit-remove)) within `device` mode, similarly to how it is done for regular nodes (section [5.7](/admin/provisioning#57-adding-new-nodes)) and other objects in BCM.

**Example**

```bash
[head->device]% add fabricswitch fswitch001
[head->device*[fswitch001*]]% show
Parameter                        Value
-------------------------------- ------------------------------------------------
Device height
Device position
Hostname                         fswitch001
Revision
Type                             FabricSwitch
Tag                              00000000a000
Mac                              00:00:00:00:00:00
Activation                       N/A
Rack
Container index                  0
Vendor
Ports                            24
Lanes per port                   4
Power control                    none
Custom power script
Custom power script argument
Power distribution units
Switch ports
Network
Ip                               0.0.0.0
User name
Password                         < not set >
Userdefined1
Userdefined2
User defined resources
Custom ping script
Custom ping script argument
Partition                        base
Notes                            <0B>
```

Similarly for a resource box:

```bash
[head->device]% add fabricresourcebox frbox001
[head->device*[my-io01*]]% show
Parameter                        Value
-------------------------------- ------------------------------------------------
Device height
Device position
Hostname                         frbox001
Revision
Type                             FabricResourceBox
Tag                              00000000a000
Mac                              00:00:00:00:00:00
Activation                       N/A
Rack
Container index                  0
Power control                    none
Custom power script
Custom power script argument
Power distribution units
Switch ports
Network
Ip                               0.0.0.0
User name
Password                         < not set >
Userdefined1
Userdefined2
User defined resources
Custom ping script
Custom ping script argument
Partition                        base
Notes                            <0B>
```

In general, adding objects that have been designed for integration into BCM means that the properties of such objects can be managed. Once their properities are correctly set up, then the objects can be managed by BCM. So, for composable infrastructure objects, this means that after the fabric switches and resource boxes have been added as objects, infrastructure composition can then be managed via BCM (section [3.19.5](#3195-using-bcm-for-composable-infrastructure-with-gigaio)).

Properties, such as the IP address, username, and password can be set for the composable infrastructure objects just added, as follows:

**Example**

```bash
[head->device*[fswitch001*]]% set ip 10.141.1.1
[head->device*[fswitch001*]]% set mac 00:22:3D:7D:00:B5
[head->device*[fswitch001*]]% set username admin@example.com
[head->device*[fswitch001*]]% set password password1
[head->device*[fswitch001*]]% set network internalnet
[head->device*[fswitch001*]]% set vendor gigaio
[head->device*[fswitch001*]]% commit
[head->device[fswitch001]]% exit

[head->device]% clone fswitch001 fswitch002          # fabric switch2 conveniently cloned
[head->device*[fswitch002*]]% set ip 10.141.1.2
[head->device*[fswitch002*]]% set mac 00:22:3D:7D:00:c5
[head->device*[fswitch002*]]% commit
[head->device[fswitch002]]% exit

[head->device]% add fabricresourcebox frbox001
[head->device*[frbox001*]]% set network internalnet
[head->device*[frbox001*]]% set ip 10.141.2.1
[head->device*[frbox001*]]% set mac 8C:AE:49:10:00:30
[head->device*[frbox001*]]% commit
```

If the MAC addresses have been set correctly, then the DHCP server on the BCM head node can assign IP address information to the GigaIO switches and resource boxes. A powercycle of all GigaIO switches and resource boxes triggers them to obtain a DHCP lease.

The device status command initally shows the newly-added devices as being down:

**Example**

```bash
[head->device]% device status
frbox001 ................. [  DOWN  ]
fswitch001 ............... [  DOWN  ]
fswitch002 ............... [  DOWN  ]
head ..................... [   UP   ]
node001 .................. [   UP   ]
node002 .................. [   UP   ]
node003 .................. [   UP   ]
node004 .................. [   UP   ]
```

After the powercycle, they are shown as being up:

**Example**

```bash
[head->device]% device status
frbox001 ................. [   UP   ]
fswitch001 ............... [   UP   ]
fswitch002 ............... [   UP   ]
head ..................... [   UP   ]
node001 .................. [   UP   ]
node002 .................. [   UP   ]
node003 .................. [   UP   ]
node004 .................. [   UP   ]
```

BCM can now use the fabric switches and resource boxes for composing the composable infrastructure.

### 3.19.5  Using BCM For Composable Infrastructure With GigaIO

This section assumes a GigaIO host software stack installation has been carried out, and that the fabric switches and resource boxes have been set up and are ready for composition (section [3.19.4](#3194-standing-up-a-bcm-cluster-with-the-gigaio-fabric)).

#### 3.19.5.1  Setting Up A Fabric Configuration

The `cmsh` modes tree has the following layout for composable infrastructure:

```bash
|-- partition
    `-- fabrics
        |-- bindings
        `-- topology
```

A fabric configuration can be specified by dropping into `fabrics` mode. This is a submode under the main `partition` mode. As is usual when working with `cmsh` objects (section [2.5.3](/admin/clustermanagement#253-working-with-objects)), a new fabric configuration object can be built using the `add` command. The bindings and topology for that fabric can then be set:

**Example**

```bash
[head->partition[base]->fabrics]% add gigaio-2
[head->partition*[base*]->fabrics*[gigaio-2*]]% show
Parameter                         Value
--------------------------------- ------------------------------------------------
Name                              gigaio-2
Revision
Binding method                    PATCH
Unbind all after topology apply   yes
Topology
Switches
Nodes
Resource boxes
[head->partition*[base*]->fabrics*[gigaio-2*]]% topology
[head->partition*[base*]->fabrics*[gigaio-2*]->topology]% show
Parameter                        Value
-------------------------------- ------------------------------------------------
Name
Revision
Template                         <4B>
Management switch                undefined
[head->partition*[base*]->fabrics*[gigaio-2*]->topology]% ..; bindings
[head->partition*[base*]->fabrics*[gigaio-2*]->bindings]% show

[head->partition*[base*]->fabrics*[gigaio-2*]->bindings]%
```

#### 3.19.5.2  Setting Up A Topology

**Topology selection:** To set a topology, a selection must be made in `topology` mode. A topology cannot be added, it can only be selected from the available topologies. The `available` command queries the GigaIO switch firmware and displays a summary of the available predefined topologies, while the `select` command allows tab-prompting to suggest the available topologies:

**Example**

```bash
[head->partition[base]->fabrics[gigaio-2]->topology]% available
Sources                 Name             Switches Zones    Links    Hosts    DSPs
----------------------- ---------------- -------- -------- -------- -------- --------
f-switch01..f-switch30  15S-12x24-1      15       7        27       12       24
f-switch01..f-switch30  1S-2x4-1         1        2        0        2        4
f-switch01..f-switch30  1S-6x0-1         1        2        0        6        0
f-switch01..f-switch30  2S-4x4-1         2        2        2        4        4
f-switch01..f-switch30  2S-4x4-3         2        2        4        4        4
f-switch01..f-switch30  30S-24x48-1      30       13       54       24       48
f-switch01..f-switch30  3S-12x0-1        3        2        3        12       0
f-switch01..f-switch30  7S-6x12-1        7        4        12       6        12

[head->partition[base]->fabrics[gigaio-2]->topology]% select <tab><tab>
15s-12x24-1  1s-2x4-1  1s-6x0-1   2s-4x4-1   2s-4x4-3   30s-24x48-1  3s-12x0-1   7s-6x12-1
[head->partition[base]->fabrics[gigaio-2]->topology]% select 1s-2x4-1
[head->partition*[base*]->fabrics*[gigaio-2*]->topology]% show
Parameter                        Value
-------------------------------- ------------------------------------------------
Name                             1S-2x4-1
Revision
Template                         <283B>
Management switch                Switch1
Zone 0                           NT
Zone 1                           zone1
Switch 1
Host switch 1, port 1
Host switch 1, port 5
DSP switch 1, port 9
DSP switch 1, port 13
DSP switch 1, port 17
DSP switch 1, port 21
```

The `available` query provides BCM with what is available in the pool for each topology, as well as the number of switches, links, and zones. The switches have defined host ports, and defined resource box ports. The cluster administrator has to set hosts for the USPs to connect to, and resource boxes (if any) for the DSPs to connect to. Links already have their names set based on the topology definition. Zones are also predefined, based on the topology definition

The names for the predefined topologies are based on the numbers in the format:

\<*switches*>`-<`*nodes*>×\<*resource boxes*>`-<`*serial*>

So, in the last session, the topology is a single switch, with 2 nodes connected to the switch, and 4 resource boxes connected to the switch. The serial number is an extra identifier label, to distinguish between otherwise identical topologies that are connected up in a different way.

The software representation of the topology defined in the object must match the hardware, or the fabric interconnects will fail when the configuration is applied.

**Topology parameter settings:** The topology representation can be set by defining the values for:

* the name of the fabric switch device

* the hosts that the switches connect to

* the resource boxes that the switches connect to

This does not specify the bindings. Bindings are how the devices connected to the switch are bound to each other. Only after the topology is set, can the bindings be set.

If selecting the 2s-4x4-3 topology, a session to set the parameter values of the topology might run as follows:

**Example**

```bash
[head->partition[base]->fabrics]% topology gigaio-1
[head->partition[base]->fabrics[GigaIO-1]->topology]% select 2s-4x4-3
[head->partition*[base*]->fabrics*[GigaIO-1*]->topology]% show
Parameter                        Value
-------------------------------- ------------------------------------------------
Name                             2S-4x4-3
Revision
Template                         <621B>
Management switch                Switch1
Zone 0                           NT
Zone 1                           zone1
Switch 1
Switch 2
s1p17dsp <-> s2p1usp             s1s2lk1
s1p19dsp <-> s2p3usp             s1s2lk2
s1p21dsp <-> s2p5usp             s1s2lk3
s1p23dsp <-> s2p7usp             s1s2lk4
Host switch 1, port 1
Host switch 1, port 5
Host switch 1, port 9
Host switch 1, port 13
DSP switch 2, port 9
DSP switch 2, port 13
DSP switch 2, port 17
DSP switch 2, port 21
```

The 2 switches, the 4 host node (USP) connections, and the 4 resource box port (DSP) connections, all need to be defined.

The host nodes are the usual regular nodes, so 4 can be allocated to the USP connections from existing node objects.

The switches are fabric switches, and 2 need to be represented. The switch objects can be added in `device` mode, if they do not already exist ([here](#31941-setting-up-the-fabric-switches-and-resource-boxes-in-composable-infrastructure-as-bcm-objects)). Similarly, the resource box objects can be added in `device` mode, if they do not already exist.

The definitions are carried out with the `set` command:

**Example**

```bash
[head->partition*[base*]->fabrics*[GigaIO-1*]->topology]% set host node001..node004
[head->partition*[base*]->fabrics*[GigaIO-1*]->topology*]% set switch f-switch01..f-switch02
[head->partition*[base*]->fabrics*[GigaIO-1*]->topology*]% set dsp io-01..io-04
[head->partition*[base*]->fabrics*[GigaIO-1*]->topology*]% commit
[head->partition*[base*]->fabrics*[GigaIO-1*]->topology]% show
Parameter                        Value
-------------------------------- ------------------------------------------------
Name                             2S-4x4-3
Revision
Template                         <621B>
Management switch                Switch1 (f-switch01)
Zone 0                           NT
Zone 1                           zone1
Switch 1                         f-switch01
Switch 2                         f-switch02
s1p17dsp <-> s2p1usp             s1s2lk1
s1p19dsp <-> s2p3usp             s1s2lk2
s1p21dsp <-> s2p5usp             s1s2lk3
s1p23dsp <-> s2p7usp             s1s2lk4
Host switch 1, port 1            node001
Host switch 1, port 5            node002
Host switch 1, port 9            node003
Host switch 1, port 13           node004
DSP switch 2, port 9             io-01
DSP switch 2, port 13            io-02
DSP switch 2, port 17            io-03
DSP switch 2, port 21            io-04
```

When the `commit` command is run the topology object is stored in BCM with the new settings, and the `show` command shows the stored settings. However, the new settings are not applied to the running composable system until the `apply` command is run.

**The `check` command in the `topology` submode:** It is possible to make mistakes in cabling configuration. The topology can be checked with the `check` command:

**Example**

```bash
[head->partition[base]->fabrics[GigaIO-1]->topology]% check
Hostname         UUID                                     Good     Information
------------     ---------------------------------- ---- -------   -----------
node001          4c4c4544-0048-4610-804a-b6c04f523532     yes
node002          4c4c4544-0044-3410-8035-c2c04f444b32     yes
node003          4c4c4544-0053-4810-8057-c4c04f434832     yes
node004          4c4c4544-0053-4a10-8056-c4c04f434835     yes
```

It may be helpful for troubleshooting to know that the field of the UUID after the last hyphen is the MAC address of the node.

**Verifying the live state with the `showlive` command in the `topology` submode:**

The cluster administrator can verify if the changes have actually been applied by running the `showlive` command to see the live state:

```bash
[head->partition[base]->fabrics[GigaIO-1]->topology]% showlive
{
  "manager": "f-switch01",
  "name": "1S-2x4-1",
  "settings": {
    "s1p13dsp": "io-02",
    "s1p17dsp": "io-03",
    "s1p1host": "node001",
    "s1p21dsp": "io-04",
    "s1p5host": "node002",
    "s1p9dsp": "io-01",
    "switch1": "f-switch01",
    "zone0": "NT",
    "zone1": "zone1"
  }
}
[head->partition[base]->fabrics[GigaIO-1]->topology]% apply
Some devices are UP, power them off or use --force
io-01, io-02, io-03, io-04, node001
```

After a reboot of affected nodes that are up, the live changes for the topology should show up:

```bash
[head->partition[base]->fabrics[GigaIO-1]->topology]% showlive
{
  "manager": "f-switch01",
  "name": "2S-4x4-3",
  "settings": {
    "s1p13host": "node004",
    "s1p17dsp": "s1s2lk1",
    "s1p19dsp": "s1s2lk2",
    "s1p1host": "node001",
    "s1p21dsp": "s1s2lk3",
    "s1p23dsp": "s1s2lk4",
    "s1p5host": "node002",
    "s1p9host": "node003",
    "s2p13dsp": "io-02",
    "s2p17dsp": "io-03",
    "s2p21dsp": "io-04",
    "s2p9dsp": "io-01",
    "switch1": "f-switch01",
    "switch2": "f-switch02",
    "zone0": "NT",
    "zone1": "zone1"
  }
}
```

The reason the `apply` command must be run explicitly is because a changed topology pushes drastic changes to the fabric, which, if incorrect, can cause the fabric to cease working. Separating the topology application from the topology representation helps prevent a cluster administrator from automatically carrying out the change.

**Setting up dynamic nodes:** Nodes in `topology` mode can be specified by the administrator to be part of a `static` or `dynamic` topology. Dynamic topology nodes in GigaIO are nodes that may change in properties quite often. The terms “static” or “dynamic” should not be confused with the use of the terms in other contexts—their use in topology remains specific to GigaIO topology.

To specify dynamic nodes, they are tagged with `:d[ynamic]`, for example (for the nodes `node001..node004` that were set earlier):

**Example**

```bash
[head->partition*[base]->fabrics[GigaIO-1]->topology]% get host
node001
node003
node003
node004
[head->partition*[base*]->fabrics*[GigaIO-1]->topology]% set host node001:d,node002,node003:d
[head->partition*[base*]->fabrics*[GigaIO-1*]->topology*]% commit
[head->partition*[base*]->fabrics*[GigaIO-1*]->topology*]% get host
node001:dynamic
node002
node003:dynamic
node004
```

The default specification—which is when there is no tag—means that the host is static, so that `node004` remains as is.

* If, as in the preceding session, a switchport is not specified for the node, then dynamic tags are allocated by the `set` command in the order that the values for `host` are specified.

  The `commit` command is executed to complete the setting of the specified tag. In particular, the topology must not be applied—that is, the `apply` command must not be run.

* If a switchport is specified for the node, then it can be set and committed separately. For example (continuing with the preceding session):

  ```bash
  [head->partition[base]->fabrics[GigaIO-1]->topology]% set host s1p5 node002:d
  [head->partition*[base*]->fabrics*[GigaIO-1*]->topology*]% commit
  [head->partition[base]->fabrics[GigaIO-1]->topology]% get host
  node001:dynamic
  node002:dynamic
  node003:dynamic
  node004
  ```

#### 3.19.5.3  Setting Up Bindings

Once the topology is set up, the bindings can be set up.

**Bindings—a simple conceptual example**

For example, using the single switch topology, 1S-2x4-1, the USPs and DSPs of the switch are meant to be allocated to nodes and resource boxes:

```bash
node001        node002

      usp1      usp2
               /
      ____switch___
     /   /        \
  dsp1  dsp2   dsp3 dsp4

io-01 io-02  io-03 io-04
```

The nodes and resource boxes may be connected physically with `node001` connected to `usp1`, and `node002` connected to `usp2`, and also `dsp1` connected to `io-01`, and so on. This is represented by setting the parameters (`set host node001..node002; set dsp io-01..io-04`). The resulting connectivity can then be represented with:

```bash
node001        node002
                |
      usp1      usp2
               /
      ____switch___
     /   /        \
  dsp1  dsp2   dsp3 dsp4
    |    |      |   |
io-01 io-02  io-03 io-04
```

How the resource is allocated to a node is known as the binding. Thus if `io-01` and `io-02` are bound to `node001`, and `io-03` and `io-04` are bound to `node02`, that is a particular binding configuration. The bindings are virtual, which means at the binding level the exact switch path is abstracted away. The configuration can then be represented with:

```bash
node001        node002
                |
      usp1      usp2
       |         |
     /         /  \
  dsp1  dsp2   dsp3 dsp4
    |    |     |    |
io-01 io-02  io-03 io-04
```

or simplifying it even further, as:

```bash
node001        node002
                |
     /         /  \
    |    |     |    |
io-01 io-02  io-03 io-04
```

**Bindings—running the `bind` command, and interpreting the bindings shown in `cmsh`:** Continuing on with the 2S-4x4-3 topology session of earlier, the bindings of a fabric configuration can be seen with the `show` command:

```bash
[head->partition[base]->fabrics[GigaIO-1]->topology]% ..;bindings
[head->partition[base]->fabrics[GigaIO-1]->bindings]% show
Zone         USP          Links             DSPs
------------ ------------ ----------------- -------------
zone1        -            s1s2lk1..s1s2lk4  io-01..io-04
zone1        node001
zone1        node002
zone1        node003
zone1        node004
zone1        s1s2lk1
zone1        s1s2lk2
zone1        s1s2lk3
zone1        s1s2lk4
```

In the preceding, there are no bindings as yet, and all the links and resources of the zone1 pool are listed. The line showing the pool itself is the entry without a USP, as indicated by the setting of “`-`” for the USP. A color-coded visual display for bindings can be seen with the `show -v|--visual` command (figure [3.33](#fig-colorizedcomposablebindings1)):

![Colorized Bindings: Nothing bound yet](/base-command-manager/product-manuals/_fern-files/nvidia-bcm-manuals.docs.buildwithfern.com/70af6f946ec4c23f318df8b3217c260d26ed0b255786456540e62b4f6e765d15/_dot_dot_/_dot_dot_/_dot_dot_/_dot_dot_/_dot_dot_/_dot_dot_/tmp/tmp-465-AR0SE6FbhiT1/latextofern/fern/assets/v10/figures/colorizedcomposablebindings1.png)

*Figure 3.33: Colorized Bindings: Nothing bound yet*

Continuing with the session, the `node001` switch port can be bound to the link `s1s2lk1` with:

```bash
[head->partition[base]->fabrics[GigaIO-1]->bindings]% bind node001 s1s2lk1
```

The `show` command then shows that `s1s2lk1` is now out of the pool, and is bound to `node001`.

```bash
[head->partition[base]->fabrics[GigaIO-1]->bindings*]% show
Zone         USP          Links             DSPs
------------ ------------ ----------------- -------------
zone1        -            s1s2lk2..s1s2lk4  io-02..io-04
zone1        node001      s1s2lk1
zone1        node002
zone1        node003
zone1        node004
zone1        s1s2lk1
zone1        s1s2lk2
zone1        s1s2lk3
zone1        s1s2lk4
```

The `show -v` command for this configuration shows (figure [3.34](#fig-colorizedcomposablebindings2)):

![Colorized Bindings: node001 switch port bound to link s1s2lk1](/base-command-manager/product-manuals/_fern-files/nvidia-bcm-manuals.docs.buildwithfern.com/647c11c56fa6cefcd9c36f245378036521818aa68bd7efa0e7bd7a63fcb4558a/_dot_dot_/_dot_dot_/_dot_dot_/_dot_dot_/_dot_dot_/_dot_dot_/tmp/tmp-465-AR0SE6FbhiT1/latextofern/fern/assets/v10/figures/colorizedcomposablebindings2.png)

*Figure 3.34: Colorized Bindings: node001 switch port bound to link s1s2lk1*

The binding path that has just been created is displayed in the same color.

Continuing the session, the `io-01` switch port can be bound to the link `s1s2lk1` with:

```bash
[head->partition[base]->fabrics[GigaIO-1]->bindings]% bind s1s2lk1 io-01
```

The `show` command then shows that the `io-01` resource box is out of the pool too, and is bound to `s1s2lk1`:

```bash
Zone         USP          Links             DSPs
------------ ------------ ----------------- -------------
zone1        -            s1s2lk2..s1s2lk4  io-02..io-04
zone1        node001      s1s2lk1
zone1        node002
zone1        node003
zone1        node004
zone1        s1s2lk1                        io-01
zone1        s1s2lk2
zone1        s1s2lk3
zone1        s1s2lk4
```

The `show -v` command for the state of the bindings then shows (figure [3.35](#fig-colorizedcomposablebindings3)):

![Colorized Bindings: Switch Link s1s2lk1 bound to resource box io-01](/base-command-manager/product-manuals/_fern-files/nvidia-bcm-manuals.docs.buildwithfern.com/606da66bf8dcb5edcd27fde72b225501a7e92319e656bc29d2b66bf4603d77cc/_dot_dot_/_dot_dot_/_dot_dot_/_dot_dot_/_dot_dot_/_dot_dot_/tmp/tmp-465-AR0SE6FbhiT1/latextofern/fern/assets/v10/figures/colorizedcomposablebindings3.png)

*Figure 3.35: Colorized Bindings: Switch Link s1s2lk1 bound to resource box io-01*

The binding path is seen displayed in the same color, all the way from the node to the resource.

**Bindings—connection rules for bindings:** Bindings on a switch occur between entities that are links, resources, or nodes. The following connection rules must be followed for bindings for the two entities being bound, if both are in the same zone:

* Resources (DSP) can be bound to nodes on the same switch

* Links can be bound to a single node on the same switch

* Resources (DSP) can be bound to a single link on the same switch

* Links can be bound to links (these should not be circular in nature)

For example, binding connection attempts as indicated by the following diagrams fail:

* binding two nodes to one link:

* binding a node via a link back to the same node:

* binding a node to a resource via two links:

On the other hand, the bindings indicated by the following diagrams succeed:

* binding one node to two links, and having the two links then each connect to a resource:

* binding one node to a single link, and that link in turn connects to two resources:

**Bindings—applying and removing the bindings:**

* The `bindings` mode does not have a `commit` command, to help prevent the cluster administrator from automatically committing the change. The command used to carry out the binding is the `apply` command. This is because a binding change means that the PCI bus has changed, which is likely to upset the kernel of the host operating system of any attached system that is running, and cause severe issues. If the devices that are to be bound are on, then it is normally a good idea to power off the devices first, as suggested by a warning message:

  ```bash
  [head->partition[base]->fabrics[GigaIO-1]->bindings*]% apply
  Some devices are UP, power them off or use --force
  io-01, io-02, io-03, io-04, node001
  ```

  Using the `-f|--force` option is very unlikely to end well.

* To remove bindings, the `unbind` command can be used

  * per resource:

    ```bash
    [head->partition[base]->fabrics[GigaIO-1]->bindings*]% unbind io-01
    ```

  * over a resource range

    ```bash
    [head->partition[base]->fabrics[GigaIO-1]->bindings*]% unbind io-01..io-02
    ```

  * over a zone

    ```bash
    [head->partition[base]->fabrics[GigaIO-1]->bindings*]% unbind zone1
    ```

  * over a zone range

    ```bash
    [head->partition[base]->fabrics[GigaIO-1]->bindings*]% unbind zone1..zone2
    ```

  * over all resources:

    ```bash
    [head->partition[base]->fabrics[GigaIO-1]->bindings*]% unbind --all
    ```

### 3.19.6  Fabric Details With `portmap`

For regular switches, the `showport` command (section [3.10.4](#3104-the-showport-mac-address-to-port-matching-tool)) can be used to find information about the switch ports used in a network.

For fabrics, the `portmap` command is used to get information about the fabric switch ports used in a fabric. Details on the links aed PCI-e generations used can also be found:

```bash
[gigaio2]% partition fabrics base
[gigaio2->partition[base]->fabrics]% use myfabric
[gigaio2->partition[base]->fabrics[myfabric]]% portmap
Switch      Partition Ports    Speed    Negotiated speed Status   Direction LTSSM    Rate       Configured
----------- --------- -------- -------- ---------------- -------- --------- -------- ---------- ----------
fswitch002  0         1-2      8        0                DOWN     USP       Detect   25.0GiT/s  16.0GiT/s
fswitch002  1         3-4      8        0                DOWN     USP       Detect   25.0GiT/s  16.0GiT/s
fswitch002  2         5-6      8        0                DOWN     USP       Detect   25.0GiT/s  16.0GiT/s
fswitch002  3         7-8      8        0                DOWN     USP       Detect   25.0GiT/s  16.0GiT/s
fswitch002  4         17-20    16       16               UP       USP       L0       16.0GiT/s  16.0GiT/s
fswitch002  5         21-24    16       16               UP       USP       L0       16.0GiT/s  16.0GiT/s
fswitch002  6         25       4        1                UP       USP       L0       5.0GiT/s   16.0GiT/s
fswitch001  0         1-2      8        8                UP       USP       L0       16.0GiT/s  16.0GiT/s
fswitch001  1         3-4      8        8                UP       USP       L0       16.0GiT/s  16.0GiT/s
fswitch001  2         5-6      8        8                UP       USP       L0       16.0GiT/s  16.0GiT/s
fswitch001  3         7-8      8        8                UP       USP       L0       16.0GiT/s  16.0GiT/s
fswitch001  4         17-20    16       16               UP       USP       L0       16.0GiT/s  16.0GiT/s
fswitch001  5         21-24    16       16               UP       USP       L0       16.0GiT/s  16.0GiT/s
fswitch001  6         25       4        1                UP       USP       L0       5.0GiT/s   16.0GiT/s
[gigaio2->partition[base]->fabrics[myfabric]]%

[gigaio2->partition[base]->fabrics[myfabric]]% portmap --leds
Switch      Port  Parti- Neighbor Cable ID  Present  Link Direction Maximum Negotiat- Rate Color
                  tion                                 UP             width ed width
----------- ----- ------ ------- ---------- -------- ---- --------- ------- --------  ---- ------
fswitch002  1     0      0                  no       no   USP       8       0         gen1 o----o
fswitch002  2     1      0                  no       no   DSP       0       0              o----o
fswitch002  3     1      0                  no       no   USP       8       0         gen1 o----o
fswitch002  4     1      0                  no       no   DSP       0       0              o----o
fswitch002  5     2      0                  no       no   USP       8       0         gen1 o----o
fswitch002  6     1      0                  no       no   DSP       0       0              o----o
fswitch002  7     3      0                  no       no   USP       8       0         gen1 o----o
fswitch002  8     1      0                  no       no   DSP       0       0              o----o
fswitch002  9     1      0       APF5011FBA yes      no   DSP       0       0              o----o
fswitch002  10    1      0       APF5011F2P yes      no   DSP       0       0              o----o
fswitch002  11    1      0       APF5011F81 yes      no   DSP       0       0              o----o
fswitch002  12    1      0       APF5011FBC yes      no   DSP       0       0              o----o
fswitch002  13    1      0                  no       no   DSP       0       0              o----o
fswitch002  14    1      0                  no       no   DSP       0       0              o----o
fswitch002  15    1      0                  no       no   DSP       0       0              o----o
fswitch002  16    1      0                  no       no   DSP       0       0              o----o
fswitch002  17    4      0       APF3940431 yes      yes  USP       16      16        gen4 o----o
fswitch002  18    1      1       APF3940430 yes      no   DSP       0       0              o----o
fswitch002  19    1      2       APF3940435 yes      no   DSP       0       0              o----o
fswitch002  20    1      3       APF3940432 yes      no   DSP       0       0              o----o
fswitch002  21    5      0       APF3940439 yes      yes  USP       16      16        gen4 o----o
fswitch002  22    1      1       APF4947GKK yes      no   DSP       0       0              o----o
fswitch002  23    1      2       APF3940436 yes      no   DSP       0       0              o----o
fswitch002  24    1      3       APF3940433 yes      no   DSP       0       0              o----o
fswitch001  1     0      0       APF5021FD3 yes      yes  USP       8       8         gen4 o----o
fswitch001  2     1      1       APF5021FCH yes      no   DSP       0       0              o----o
fswitch001  3     1      0       APF5021FC6 yes      yes  USP       8       8         gen4 o----o
fswitch001  4     1      1       APF5021FDU yes      no   DSP       0       0              o----o
fswitch001  5     2      0       APF5021FDB yes      yes  USP       8       8         gen4 o----o
fswitch001  6     1      1       APF5021FC5 yes      no   DSP       0       0              o----o
fswitch001  7     3      0       APF5021FDN yes      yes  USP       8       8         gen4 o----o
fswitch001  8     1      1       APF5021FDH yes      no   DSP       0       0              o----o
fswitch001  9     1      0       APF5011FBP yes      no   DSP       0       0              o----o
fswitch001  10    1      0       APF5011F85 yes      no   DSP       0       0              o----o
fswitch001  11    1      0       APF5011F2E yes      no   DSP       0       0              o----o
fswitch001  12    1      0       APF5011FBE yes      no   DSP       0       0              o----o
fswitch001  13    1      0                  no       no   DSP       0       0              o----o
fswitch001  14    1      0                  no       no   DSP       0       0              o----o
fswitch001  15    1      0                  no       no   DSP       0       0              o----o
fswitch001  16    1      0                  no       no   DSP       0       0              o----o
fswitch001  17    4      0       APF3940431 yes      yes  USP       16      16        gen4 o----o
fswitch001  18    1      1       APF3940430 yes      no   DSP       0       0              o----o
fswitch001  19    1      2       APF3940435 yes      no   DSP       0       0              o----o
fswitch001  20    1      3       APF3940432 yes      no   DSP       0       0              o----o
fswitch001  21    5      0       APF3940439 yes      yes  USP       16      16        gen4 o----o
fswitch001  22    1      1       APF4947GKK yes      no   DSP       0       0              o----o
fswitch001  23    1      2       APF3940436 yes      no   DSP       0       0              o----o
fswitch001  24    1      3       APF3940433 yes      no   DSP       0       0              o----o
```

The color column shows the led status at the FabreX port. In that column, an “o” represents an LED. The LED can be one of several colors, and it can be blinking. The meaning of the LED lights is covered by GigaIO documentation.

### 3.19.7  Monitoring Data Metrics For A Fabric

There are a number of fabric-related metrics that can be plotted to learn about how the fabric is being used over time.

```bash
[gigaio2]% partition use base
[gigaio2->partition[base]]% latestmetricdata | grep Fabric
FabricTopologies                             Fabric       1            9.01s
FabricTopologyHostUsage                      Fabric       25.0%        9.01s
FabricTopologyResourceBoxUsage               Fabric       33.3%        9.01s
[gigaio2->partition[base]]% device use frbox001
[gigaio2->device[frbox001]]% dumpmonitoringdata -1d now fabricbindings
# Start          - Tue May 17 11:41:52 2022 (1652780512)
# End            - Wed May 18 11:41:52 2022 (1652866912)
# FabricBindings - Number of bindings made in the fabric
Timestamp                  Value      Info
-------------------------- ---------- ----------
2022/05/17 15:07:00        0
2022/05/17 15:41:00        0
2022/05/17 15:43:00        1
2022/05/18 11:41:00        1
[gigaio2->device[frbox001]]%
```

### 3.19.8  Adding FabreX NTB Interfaces

The FabreX cards can also optionally be used for point to point communication, as a Non-Transparent Bridge (NTB) on the PCI-e network. For this to work, a network with an IP address range is defined, and `ntb0` interfaces are defined on all nodes:

```bash
[gigaio2]% network add fabrex
[gigaio2->network*[fabrex*]]% set baseaddress 10.147.0.0
[gigaio2->network*[fabrex*]]% set netmaskbits 16
[gigaio2->network*[fabrex*]]% set domainname fabrex.cluster
[gigaio2->network*[fabrex*]]% commit
[gigaio2->network[fabrex]]% device
[gigaio2->device]% addinterface -n node[001-004] physical ntb0 fabrex 10.147.0.1
[gigaio2->device*]% commit
Successfully committed 4 Devices
[gigaio2->device]% device power reset -n node[001-004]
```

When the nodes come back up, a connectivity check can be carried out to verify node-to-node communications are working the FabreX interface, by using the `connectivity` command from within `device` mode:

```bash
[gigaio2]% device
[gigaio2->device]% connectivity --network fabrex --fabric myfabric
Source   Destination Result       ID   Latency
-------- ----------- ------------ ---- ------------
node001  node001     Ok           0    0.1ms
node001  node002     Ok           0    0.2ms
node001  node003     Ok           0    0.2ms
node001  node004     Ok           0    0.2ms
node002  node001     Ok           0    0.2ms
node002  node002     Ok           0    0.1ms
node002  node003     Ok           0    0.2ms
node002  node004     Ok           0    0.2ms
node003  node001     Ok           0    0.2ms
node003  node002     Ok           0    0.2ms
node003  node003     Ok           0    0.1ms
node003  node004     Ok           0    0.2ms
node004  node001     Ok           0    0.3ms
node004  node002     Ok           0    0.2ms
node004  node003     Ok           0    0.2ms
node004  node004     Ok           0    0.1ms

[gigaio2->device]%
```

The data values for latency are found using a non-optimized method. The values reported should therefore not be used as a latency benchmark for the interconnect.

### 3.19.9  Diagnosing FabreX Problems On The Nodes

If there are problems with connectivity over the FabreX network, then the easiest way to gain an insight into what is wrong is to log into a node and run the `fabrex-status.sh` utility:

```bash
root@node001:~# fabrex-status.sh
============================================================
                     Host Details
 - Hostname................: node001
 - IP......................: 10.141.0.1
 - IOMMU...................: Enabled
 - Uptime..................: 5:06,1
 - CPU usage...............: 0.08, 0.08, 0.03 (1, 5, 15 min)
 - Memory used.............: 1885 MB / 128764 MB
 - Space on /..............:
============================================================
                     Fabric Details
 - Manager: fswitch001    Switchtec NTB Control Plane Link Status
   Nodename "node001": FLID: 0x00000005
    NIC IDX: 0
    NTB NIC GUID: 0x0000050111200010
    Partition 0
    Peers: 3
   PNUM  STATE  PCCS  LLINK  POLL  PSTATE  PLINK  EPOCH  FLID        PEER ID
      0  rdy    cfg   up     slow  rdy     up         1  0x00000006  node002
      1  rdy    cfg   up     slow  rdy     up         1  0x00000008  node003
      2  rdy    cfg   up     slow  rdy     up         1  0x00000007  node004
============================================================
                     NTB Netdev Network
```

## 3.20  Cluster Configuration Without Execution By CMDaemon

### 3.20.1  Cluster Configuration: The Bigger Picture

The configurations carried out in this chapter so far are based almost entirely on configuring nodes, via a CMDaemon front end (`cmsh` or Base View), using CMDaemon to execute the change. Indeed, much of this manual is about this too because it is the preferred technique. It is preferred:

* because it is intended by design to be the easiest way to do common cluster tasks,

* and also generally keeps administration overhead minimal in the long run since it is CMDaemon rather than the system administrator that then takes care of tracking the cluster state.

There are however other cluster configuration techniques besides execution by CMDaemon. To get some perspective on these, it should be noted that cluster configuration techniques are always fundamentally about modifying a cluster so that it functions in a different way. The techniques can then for convenience be separated out into modification techniques that rely on CMDaemon execution and techniques that do not, as follows:

1. **Configuring nodes with execution by CMDaemon:** As explained, this is the preferred technique. The remaining techniques listed here should therefore usually only be considered if the task cannot be done with Base View or `cmsh`.

2. **Replacing the node image:** The image on a node can be replaced by an entirely different one, so that the node can function in another way. This is covered in section [3.20.2](#3202-making-nodes-function-differently-by-image). It can be claimed that since it is CMDaemon that selects the image, this technique should perhaps be classed as under item 1. However, since the execution of the change is really carried out by the changed image without CMDaemon running on the image, and because changing the entire image to implement a change of functionality is rather extreme, this technique can be given a special mention outside of CMDaemon execution.

3. **Using a `FrozenFile` directive:** Applied to a configuration file, this directive prevents CMDaemon from executing changes on that file for nodes. During updates, the frozen configuration may therefore need to be changed manually. The prevention of CMDaemon acting on that file prevents the standard cluster functionality that would run based on a fully CMDaemon-controlled cluster configuration. The `FrozenFile` directive is introduced in section [2.6.5](/admin/clustermanagement#265-configuration-file-modification-and-the-frozenfile-directive), and covered in the configuration context in section [3.20.3](#3203-making-all-nodes-function-differently-from-normal-cluster-behavior-with-frozenfile).

4. **Using an `initialize` or `finalize` script:** This type of script is run during the initrd stage, much before CMDaemon on the regular node starts up. It is run if the functionality provided by the script is needed before CMDaemon starts up, or if the functionality that is needed cannot be made available later on when CMDaemon is started on the regular nodes. CMDaemon does not execute the functionality of the script itself, but the script is accessed and set on the initrd via a CMDaemon front end (Appendix [E.2](/admin/finalize#e2-accessing-from-base-view-and-cmsh)), and executed during the initrd stage. It is often convenient to carry out minor changes to configuration files inside a specific image in this way, as shown by the example in Appendix [E.5](/admin/finalize#e5-storing-a-configuration-to-a-filesystem). The `initialize` and `finalize` scripts are introduced in section [3.20.4](#3204-adding-functionality-to-nodes-via-an-initialize-or-finalize-script).

5. **A shared directory:** Nodes can be configured to access and execute a particular software stored on a shared directory of the cluster. CMDaemon does not execute the functionality of the software itself, but is able to mount and share directories, as covered in section [3.13](#313-configuring-nfs-volume-exports-and-mounts).

Finally, outside the stricter scope of cluster configuration adjustment, but nonetheless a broader way to modify how a cluster functions, and therefore mentioned here for more completeness, is:

1. **Software management:** the installation, maintenance, and removal of software packages. Standard post-installation software management based on repositories is covered in sections [11.2](/admin/softwareimagemanagement#112-managing-packages-on-the-head-node)–[11.6](/admin/softwareimagemanagement#116-creating-a-custom-software-image). Third-party software management from outside the repositories, for software that is part of BCM is covered in [Chapter 7 of the *Installation Manual*](/installation/thirdparty).

   Third-party software that is not part of BCM can be managed on the head node as on any other Linux system, and is often placed under `/opt` or other recommended locations. If required by the other nodes, then the software should typically be set up by the administrator so that it can be accessed via a shared filesystem.

### 3.20.2  Making Nodes Function Differently By Image

#### 3.20.2.1  Making All Nodes Function Differently By Image

To change the name of the image used for an entire cluster, for example after cloning the image and modifying it (section [3.20.2.2](#32022-making-some-nodes-function-differently-by-image)), the following methods can be used:

* in Base View, via `Cluster` > `Settings` > `Cluster name`

* or in `cmsh` from within the `base` object of `partition` mode

A system administrator more commonly sets the software image on a per-category or per-node basis (section [3.20.2.2](#32022-making-some-nodes-function-differently-by-image)).

#### 3.20.2.2  Making Some Nodes Function Differently By Image

For minor changes, adjustments can often be made to node settings via initialize and finalize scripts so that nodes or node categories function differently (section [3.20.4](#3204-adding-functionality-to-nodes-via-an-initialize-or-finalize-script)).

For major changes on a category of nodes, it is usually more appropriate to have nodes function differently from each other by simply carrying out image changes per node category with CMDaemon. Carrying out image changes per node is also possible. As usual, node settings override category settings.

**Modifying images via cloning primitives for a node or category:** Setting a changed image for a category can be done as follows with `cmsh`:

1. The image on which the new one will be based is cloned. The cloning operation not only copies all the settings of the original (apart from the name), but also the data of the image:

   **Example**

   ```bash
   [root@basecm10 ~]# cmsh
   [basecm10]% softwareimage
   [basecm10->softwareimage]% clone default-image imagetwo
   [basecm10->softwareimage*[imagetwo*]]% commit
   ... [notice] basecm10: Started to copy: /cm/images/default-image -> /cm/images/imagetwo
   [basecm10->softwareimage*[imagetwo*]]%
   ... [notice] basecm10: Copied: /cm/images/default-image -> /cm/images/imagetwo
   [basecm10->softwareimage[imagetwo]]%
   ```

2. After cloning, the settings can be modified in the new object. For example, if the kernel needs to be changed to suit nodes with different hardware, kernel modules settings are changed (section [5.3.2](/admin/provisioning#532-selecting-kernel-driver-modules-to-load-onto-nodes)) and committed. This creates a new image with a new ramdisk.

   Other ways of modifying and committing the image for the nodes are also possible, as discussed in sections [11.2](/admin/softwareimagemanagement#112-managing-packages-on-the-head-node)–[11.6](/admin/softwareimagemanagement#116-creating-a-custom-software-image).

3. The modified image that is to be used by the differently functioning nodes is placed in a new category in order to have the nodes be able to choose the image. To create a new category easily, it can simply be cloned. The image that the category uses is then set:

   ```bash
   [basecm10->softwareimage[imagetwo]]% category
   [basecm10->category]% clone default categorytwo
   [basecm10->category*[categorytwo*]]% set softwareimage imagetwo
   [basecm10->category*[categorytwo*]]% commit
   [basecm10->category[categorytwo]]%
   ```

4. * For just one node, or a few nodes, the node can be set from `device` mode to the new category (which has the new image):

     ```bash
     [basecm10->category[categorytwo]]% device
     [basecm10->device]% use node099
     [basecm10->device[node099]]% set category categorytwo
     [basecm10->device*[node099*]]% commit; exit
     ```

   * If there are many nodes, for example node100 sequentially up to node200, they can be set to that category using a `foreach` loop like this:

     **Example**

     ```bash
     [basecm10->device]% foreach -n node100..node200 (set category categorytwo)
     [basecm10->device*]% commit
     ```

5. Rebooting restarts the nodes that are assigned to the new category with the new image.

**Modifying images by adding files in the `cm/conf` directory, for a category, node, or MAC address:** The preceding 5-step method is understandable. For just a few file changes it is perhaps overkill and not very elegant. BCM has a more structured and efficient way to make some nodes function differently by image if only a few file additions are to be carried out. The specification adds the files in the image via a target path that is specified in special configuration locations in the image. It can be configured per node, but also per category and MAC address.

* For a category, the specification takes the form:

  `/cm/images/` \<*image*>`/cm/conf/category/<`*category*>/ \<*target*>

  Thus, if some file on the node is to be placed so that on a running node it is at `/path/to/some.file`, and this needs to be configured for an image `default-image`, and a category `default`, then it would be placed at this location on the head node:

  **Example**

  ```bash
     /cm/images/default-image/cm/conf/category/default/path/to/some.file
  ```

  The file on the target node would be placed in the absolute directory `/path/to/some.file`

  Multiple categories can be configured per image. Thus, for example, beside the `default` category, an additional `gpu` category can exist:

  **Example**

  ```bash
     /cm/images/default-image/cm/conf/category/gpu/path/to/some.file
  ```

  Also, multiple files can be specified per category per image. Thus, beside the file `some.file`, an additional file `some.other.file` could be placed:

  **Example**

  ```bash
     /cm/images/default-image/cm/conf/category/gpu/path/to/some.file
     /cm/images/default-image/cm/conf/category/gpu/path/to/some.other.file
  ```

* For a node, the configuration form is:

  `/cm/images/` \<*image*>`/cm/conf/node/<`*node name*>/ \<*target*>

  An example for a node called `node001` could then be:

  **Example**

  ```bash
     /cm/images/default-image/cm/conf/node/node001/path/to/some.file
  ```

* For a MAC address, the configuration form is:

  `/cm/images/` \<*image*>`/cm/conf/node/<`*MAC address*>/ \<*target*>

  An example for a node with MAC address `00:aa:bb:cc:dd:ee` could then be:

  **Example**

  ```bash
     /cm/images/default-image/cm/conf/node/00-aa-bb-cc-dd-ee/path/to/some.file
  ```

The copying of the specified files to the image is done just before the finalize stage of the node-installer (section [5.4.11](/admin/provisioning#5411-running-finalize-scripts)) during node provisioning.

A common theme in BCM is that node-level configuration overrides category-level configuration. In keeping with this behavior, a file configuration at category level could be applied to the many nodes in a category. And, a file configuration copy at node level (for a node that is in the category) overrides the category level value for just that particular node.

### 3.20.3  Making All Nodes Function Differently From Normal Cluster Behavior With `FrozenFile`

Configuration changes carried out by Base View or `cmsh` often generate, restore, or modify configuration files (Appendix [A](/admin/generatedfiles)).

However, sometimes an administrator may need to make a direct change (without using Base View or `cmsh`) to a configuration file to set up a special configuration that cannot otherwise be done.

The `FrozenFile` directive to CMDaemon (Appendix [C.69](/admin/cmdconf#c69-frozenfile-directive), [here](/admin/cmdconf#c69-frozenfile-directive)) applied to such a configuration file stops CMDaemon from altering the file. The frozen configuration file is generally applicable to all nodes and is therefore a possible way of making all nodes function differently from their standard behavior.

Freezing files is however best avoided, if possible, in favor of a CMDaemon-based method of configuring nodes, for the sake of administrative maintainability.

### 3.20.4  Adding Functionality To Nodes Via An `initialize` Or `finalize` Script

CMDaemon can normally be used to allocate different images per node or node category as explained in section [3.20.2.2](#32022-making-some-nodes-function-differently-by-image). However, some configuration files do not survive a reboot (Appendix [A](/admin/generatedfiles)), sometimes hardware issues can prevent a consistent end configuration, and sometimes drivers need to be initialized before provisioning of an image can happen. In such cases, an `initialize` or `finalize` script (sections [5.4.5](/admin/provisioning#545-running-initialize-scripts), [5.4.11](/admin/provisioning#5411-running-finalize-scripts), and Appendix [E.5](/admin/finalize#e5-storing-a-configuration-to-a-filesystem)) can be used to initialize or configure nodes or node categories.

These scripts are also useful because they can be used to implement minor changes across nodes:

**Example**

Supposing that some nodes with a particular network interface have a problem auto-negotiating their network speed, and default to 100Mbps instead of the maximum speed of 1000Mbps. Such nodes can be set to ignore auto-negotiation and be forced to use the 1000Mbps speed by using the `ETHTOOL_OPTS` configuration parameter in their network interface configuration file: `/etc/sysconfig/network-scripts/ifcfg-eth0` (or `/etc/sysconfig/network/ifcfg-eth0` in SUSE).

The `ETHTOOL_OPTS` parameter takes the options to the “`ethtool -s` \<*`device`*>” command as options. The value of \<*device*> (for example `eth0`) is specified by the filename that is used by the configuration file itself (for example `/etc/sysconfig/network-scripts/ifcfg-eth0`). The `ethtool` package is installed by default with BCM. Running the command:

```bash
ethtool -s autoneg off speed 1000 duplex full
```

turns out after some testing to be enough to reliably get the network card up and running at 1000Mbps on the problem hardware.

However, since the network configuration file is overwritten by node-installer settings during reboot, a way to bring persistence to the file setting is needed. One way to ensure persistence is to append the configuration setting to the file with a `finalize` script, so that it gets tagged onto the end of the configuration setting that the node-installer places for the file, just before the network interfaces are taken down again in preparation for `init`.

The script may thus look something like this for a Red Hat system:

```bash
#!/bin/bash

## node010..node014 get forced to 1000 duplex
if [[ $CMD_HOSTNAME = node01[0-4] ]]
then
echo 'ETHTOOL_OPTS="speed 1000 duplex full"'>>/localdisk/etc/sysconfig/network-scripts/ifcfg-eth0
fi
```

The method of enforcing an interface space just outlined is actually just for educational illustration, and is not a recommended method.

In practice, the recommended way to enforce an interface speed is to simply set it in the CMDaemon database. For example, for the boot interface of `node001` it could be via the Base View navigation path:

`Devices` > `Nodes[node001]` > `Edit` > `Settings` > `Interfaces[BOOTIF]` > `Edit` > `Speed`

### 3.20.5  Examples Of Configuring Nodes With Or Without CMDaemon

A node or node category can often have its software configured in CMDaemon via Base View or `cmsh`:

**Example**

**Configuring a software for nodes using Base View or `cmsh`:** If the software under consideration is CUPS, then a node or node category can manage it from Base View or `cmsh` as outlined in section [3.14.2](#3142-managing-and-configuring-servicesexamples).

A counterexample to this is:

**Example**

**Configuring a software for nodes without using Base View or `cmsh`, using an image:** Software images can be created with and without CUPS configured, without using Base View or `cmsh` except to link nodes to their appropriate image via the associated category. Setting up nodes to load one of these two images via a node category is an alternative way of letting nodes run CUPS.

Whether node configuration for a particular functionality is done with CMDaemon, or directly with the software, depends on what an administrator prefers. In the preceding two examples, the first example, that is the one with Base View or `cmsh` setting the CUPS service, is likely to be preferred over the second example, where an entire separate image must be maintained. A new category must also be created in the second case.

Generally, sometimes configuring the node via BCM, and not having to manage images is better, sometimes configuring the software and making various images to be managed out of it is better, and sometimes only one of these techniques is possible anyway.

#### 3.20.5.1  Configuring Nodes Using Base View Or `cmsh`: Category Settings

When configuring nodes using Base View or `cmsh`, configuring particular nodes from a node category to overrule the state of the rest of its category (as explained in section [2.1.3](/admin/clustermanagement#213-node-categories)) is sensible for a small number of nodes. For larger numbers it may not be organizationally practical to do this, and another category can instead be created to handle nodes with the changes conveniently.

The CUPS service in the next two examples is carried out by implementing the changes via Base View or `cmsh` acting on CMDaemon.

**Example**

**Setting a few nodes in a category:** If only a few nodes in a category are to run CUPS, then it can be done by enabling CUPs just for those few nodes, thereby overriding (section [2.1.3](/admin/clustermanagement#213-node-categories)) the category settings.

**Example**

**Setting many nodes to a category:** If there are many nodes that are to be set to run CUPS, then a separate, new category can be created (cloning it from the existing one is easiest) and those many nodes are moved into that category, while the image is kept unchanged. The CUPS service setting is then set at category level to the appropriate value for the new category.

In contrast to these two examples, the software image method used in section [3.20.2.2](#32022-making-some-nodes-function-differently-by-image) to implement a functionality such as CUPS would load up CUPS as configured in an image, and would not handle it via CMDaemon (except to link nodes to their appropriate image via the associated category). So, in section [3.20.2.2](#32022-making-some-nodes-function-differently-by-image), software images prepared by the administrator are set for a node category. Since, by design, images are only selected for a category, a node cannot override the image used by the category other than by creating a new category, and using it with the new image. The administrative overhead of this can be inconvenient.

Administrators would therefore normally prefer letting CMDaemon track software functionality across nodes as in the last two examples, rather than having to deal with tracking software images manually. Indeed, the `roles` assignment option (section [2.1.5](/admin/clustermanagement#215-roles)) is just a special pre-configured functionality toggle that allows CMDaemon to set categories or regular nodes to provide certain functions, typically by enabling services.

## 3.21  Saving A Backup Of Configuration Files With `versionconfigfiles`

If `versionconfigfiles` is set to the value `yes` for a node or a category, then if configuration files changed for that node or category due to CMDaemon, then the old configuration files are saved.

**Example**

```bash
[root@basecm10 ~]# cmsh
[basecm10]% device use node001
[basecm10->device[node001]]% set versionconfigfiles yes; commit
```

This is useful, for example, if an administrator would like to know what the configuration was just before it was changed.

If a configuration change takes place, then the old configuration files are automatically sent from the node where they changed, to the active head node. The configuration files:

* are saved on the active head node under the directory `/var/spool/cmd/config_file_versions`, under their node name.

* have a modification time that indicates the time of the change.

* are given a suffix in the form of the local unix epoch time.

**Example**

```bash
[root@basecm10 ~]# cd /var/spool/cmd/
[root@basecm10 cmd]# tree -a --charset=C config_file_versions/
config_file_versions/
|-- node001
|   |-- cm
|   |   `-- local
|   |       `-- modulefiles
|   |           `-- slurm
|   |               |-- .modulerc.lua.1970-01-01_01:00:00
|   |               `-- slurm
|   |                   `-- 21.08.8.1970-01-01_01:00:00
...

[root@basecm10 cmd]# cd config_file_versions/node001/cm/local/modulefiles/slurm/
[root@basecm10 slurm]# ls -al .modulerc.lua.1970-01-01_01:00:00
-rw-r--r-- 1 root root 43 Mar 14 17:22 .modulerc.lua.1970-01-01_01:00:00
[root@basecm10 slurm]#
```