# Day-to-day Administration

Just as for regular Linux system administration, it is a best practice for cluster administration procedures to be documented as they are carried out.

Updating software packages for bug fixes or for security fixes is a substantial and important part of the tasks carried out in daily cluster administration. It has its own chapter (Chapter [9](/admin/softwareimagemanagement)).

This chapter discusses other tasks that may come up in day-to-day cluster administration with NVIDIA Base Command Manager.

Section [14.1](#141-parallel-shells-pdsh-and-pexec) discusses running shell commands in parallel over the cluster.

Section [14.2](#142-getting-support-with-bcm-issues-and-notifications-for-release-updates) discusses how a cluster administrator can ask the help of the BCM support team for guidance with an issue in an optimum manner.

Section [14.3](#143-backups) discusses how backups can be implemented for BCM.

Section [14.4](#144-revision-control-for-images) discusses revision control for images.

Section [14.5](#145-bios-and-firmware-management) discusses BIOS configuration with BCM.

Section [14.6](#146-hardware-match-check-with-the-hardware-profile-data-producer) discusses checking hardware matching across the nodes of the cluster.

Section [14.7](#147-serial-over-lan-console-access) discusses Serial Over LAN console access.

Section [14.8](#148-managing-raw-monitoring-data) discusses administrative aspects of handling the large amounts of raw monitoring data.

Section [14.9](#149-node-replacement) discusses node replacement.

Section [14.10](#1410-ansible-and-nvidia-base-command-manager) discusses using Ansible to configure the cluster via Ansible collections and playbooks.

## 14.1  Parallel Shells: `pdsh` And `pexec`

#### 14.1.0.1  What `pdsh` And `pexec` Do

The cluster management tools include two parallel shell execution commands:

* `pdsh` (parallel distributed shell, section [14.1.1](#1411-pdsh-in-the-os-shell)), runs from within the OS shell. That is, `pdsh` executes its commands from within `bash` by default.

* `pexec` (parallel execute, section [14.1.2](#1412-pexec-in-cmsh), runs from within CMDaemon. That is, `pexec` executes its commands from within the `cmsh` front end.

A one-time execution of `pdsh` or `pexec` can run one or more shell commands on a group of nodes in parallel.

#### 14.1.0.2  A Warning About Power Surge Risks With `pdsh` And `pexec`

Some care is needed when running `pdsh` or `pexec` with commands that affect power consumption. For example, running commands that power-cycle devices in parallel over a large number of nodes can be risky because it can put unacceptable surge demands on the power supplies.

Within `cmsh`, executing a `power reset` command from `device` mode to power cycle a large group of nodes is much safer than running a parallel command to do a reset using `pdsh` or `pexec`. This is because the CMDaemon power reset powers up nodes after a deliberate delay between nodes (section [4.2](/admin/power#42-power-operations)).

#### 14.1.0.3  Which Command To Use Out Of `pdsh` And `pexec`

The choice of using `pdsh` or `pexec` commands is mostly up to the administrator. The only time that running `pdsh` from `bash` is currently required instead of running `pexec` from within `cmsh`, is when stopping and restarting CMDaemon on a large number of regular nodes (section [2.6.1](/admin/clustermanagement#261-managing-and-inspecting-the-cluster-management-daemon)). This is because a command to stop CMDaemon on a regular node, that itself relies on being run from a running CMDaemon on a regular node, can obviously give unexpected results.

### 14.1.1  `pdsh` In The OS Shell

#### 14.1.1.1  Packages Required For `pdsh`

By default, the following packages must be installed from the BCM repositories to the head node for `pdsh` to function fully:

* `pdsh`

* `genders`

* `pdsh-mod-cmupdown`

* `pdsh-mod-genders`

* `pdsh-rcmd-exec`

* `pdsh-ssh`

The `pdsh` utility is modular, that is, it gets extra functionality through the addition of modules.

The `genders` package is used to generate a default `/etc/genders` configuration file. The file is used to decide what and how nodes are to be used or excluded by default, when used with `pdsh`. Configuration details can be found in `man pdsh(1)`. The configuration can probably best be understood by viewing the file itself and noting that BCM in the default configuration associates the following *genders* with a list of nodes:

* `all`: all the nodes in the cluster, head and regular nodes.

* `category=default`: the nodes that are in the default category

* `computenode`: regular nodes

* `headnode`: node or nodes that are head nodes.

In a newly-installed cluster using default settings, the genders `category=default` and `computenode` have the same list of nodes to begin with.

The default `/etc/genders` file has a section that is generated and maintained by CMDaemon, but the file can be altered by the administrator outside the CMDaemon-maintained section. However, it is not recommended to change the file manually frequently. For example, tracking node states with this file is not recommended. Instead, the package `pdsh-mod-cmupdown` provides the `-v` option for node state tracking functionality, and how to use this and other `pdsh` options is described in the next section.

#### 14.1.1.2  `pdsh` Options

In the OS shell, running `pdsh -h` displays the following help text:

```bash
Usage: pdsh [-options] command ...
-S                return largest of remote command return values
-h                output usage menu and quit
-V                output version information and quit
-q                list the option settings and quit
-b                disable ^C status feature (batch mode)
-d                enable extra debug information from ^C status
-l user           execute remote commands as user
-t seconds        set connect timeout (default is 10 sec)
-u seconds        set command timeout (no default)
-f n              use fanout of n nodes
-w host,host,...  set target node list on command line
-x host,host,...  set node exclusion list on command line
-R name           set rcmd module to name
-M name,...       select one or more misc modules to initialize first
-N                disable hostname: labels on output lines
-L                list info on all loaded modules and exit
-v                exclude targets if they are down
-g query,...      target nodes using genders query
-X query,...      exclude nodes using genders query
-F file           use alternate genders file `file'
-i                request alternate or canonical hostnames if applicable
-a                target all nodes except those with "pdsh_all_skip" attribute
-A                target all nodes listed in genders database
available rcmd modules: ssh,exec (default: ssh)
```

Further options and details are given in `man pdsh(1)`.

#### 14.1.1.3  Examples Of `pdsh` Use

For the examples in this section, a cluster can be considered that is set up with two nodes, with the state of node001 being `UP` and that of node002 being `DOWN`:

```bash
[root@basecm11 ~]# cmsh -c "device status"
node001 .................. [   UP   ]
node002 .................. [  DOWN  ]
basecm11 ................. [   UP   ]
```

In the examples, the outputs for `pdsh` could be as follows for the `pdsh` options considered:

**`-A`**: With this `pdsh` option an attempt is made to run the command on all nodes, regardless of the node state:

**Example**

```bash
[root@basecm11 ~]# pdsh -A hostname
node001: node001
node002: ssh: connect to host node002 port 22: No route to host
pdsh@basecm11: node002: ssh exited with exit code 255
basecm11: basecm11
```

**`-v`**: With this option an attempt is made to run the command only on nodes nodes that are in the state `UP`:

**Example**

```bash
[root@basecm11 ~]# pdsh -A -v hostname
node001: node001
basecm11: basecm11
```

**`-g`**: With this option, and using, for example, `computenode` as the genders query, only nodes within `computenode` in the `/etc/genders` file are considered for the command. The `-v` option then further ensures that the command runs only on a node in `computenode` that is up. In a newly-installed cluster, regular nodes are assigned to `computenode` by default, so the command runs on all regular nodes that are up in a newly-installed cluster:

**Example**

```bash
[root@basecm11 ~]# pdsh -v -g computenode hostname
node001: node001
```

**`-w`**: This option allows a node list (`man pdsh(1)`) to be specified on the command line itself:

**Example**

```bash
[root@basecm11 ~]# pdsh -w node00[1-2] hostname
node001: node001
node002: ssh: connect to host node002 port 22: No route to host
pdsh@basecm11: node002: ssh exited with exit code 255
```

**`-x`**: This option is the converse of `-w`, and excludes a node list that is specified on the command line itself:

**Example**

```bash
[root@basecm11 ~]# pdsh -x node002 -w node00[1-2] hostname
node001: node001
```

#### 14.1.1.4  The `dshbak` Command

The `dshbak` (distributed shell backend formatting filter) command is a filter that reformats `pdsh` output. It comes with the `pdsh` package.

Running `dshbak` with the `-h` option displays:

```bash
[root@basecm11 ~]# dshbak -h
Usage: dshbak [OPTION]...
 -h       Display this help message
 -c       Coalesce identical output from hosts
 -d DIR   Send output to files in DIR, one file per host
 -f       With -d, force creation of DIR
```

Further details can be found in `man dshbak(1)`.

For the examples in this section, it is assumed that all the nodes in the cluster are now up. That is, `node002` used in the examples of the preceding section is now also up. Some examples to illustrate how `dshbak` works are then the following: **Without `dshbak`:**

**Example**

```bash
[root@basecm11 ~]# pdsh -A ls /etc/services /etc/yp.conf
basecm11: /etc/services
basecm11: /etc/yp.conf
node001: /etc/services
node001: ls: cannot access /etc/yp.conf: No such file or directory
pdsh@basecm11: node001: ssh exited with exit code 2
node002: /etc/services
node002: /etc/yp.conf
```

**With `dshbak`, with no `dshbak` options:**

**Example**

```bash
[root@basecm11 ~]# pdsh -A ls /etc/services /etc/yp.conf | dshbak
node001: ls: cannot access /etc/yp.conf: No such file or directory
pdsh@basecm11: node001: ssh exited with exit code 2
----------------
basecm11
----------------
/etc/services
/etc/yp.conf
----------------
node001
----------------
/etc/services
----------------
node002
----------------
/etc/services
/etc/yp.conf
[root@basecm11 ~]#
```

**With `dshbak`, with the `-c` (coalesce) option:**

**Example**

```bash
[root@basecm11 ~]# pdsh -A ls /etc/services /etc/yp.conf | dshbak -c
node001: ls: cannot access /etc/yp.conf: No such file or directory
pdsh@basecm11: node001: ssh exited with exit code 2
----------------
node002,basecm11
----------------
/etc/services
/etc/yp.conf
----------------
node001
----------------
/etc/services
[root@basecm11 ~]#
```

The `dshbak` utility is useful for creating human-friendly output in clusters with larger numbers of nodes.

### 14.1.2  `pexec` In `cmsh`

In `cmsh`, the `pexec` command is run from `device` mode:

**Example**

```bash
[basecm11->device]% pexec -n node001,node002 "cd ; ls"

[node001] :
anaconda-ks.cfg
install.log
install.log.syslog

[node002] :
anaconda-ks.cfg
install.log
install.log.syslog

```

### 14.1.3  `pexec` In Base View

In Base View, `pexec` is hidden, but executed in a GUI wrapper, using the navigation path `Cluster` > `Run command`.

For large numbers of nodes, rendering the output into the node subpanes (little boxes) can take a long time. To improve the Base View experience, selecting the `Single text view` icon instead of the `Grouped view` icon speeds up the rendering significantly, but at the cost of removing the borders of the subpanes.

Ticking the `Join output` checkbox places output that is the same for particular nodes, into the same subpane.

Running parallel shell commands from `cmsh` instead of in Base View is faster in most cases, due to less graphics rendering overhead.

### 14.1.4  Using The `-j|--join` Option Of `pexec` In `cmsh`

The output of the `pexec` command by default can come out in a sequence depending on node response time. To make it more useful for an administrator, order can be imposed on the output. Checking consistency across nodes is then easier.

For example, in a cluster with 2 nodes, the `/etc/resolv.conf` files for each node could be displayed as:

**Example**

```bash
[basecm11->device]% pexec -c default "cat /etc/resolv.conf"

[node001] :
# This file was generated by the Node Installer.
search cm.cluster eth.cluster brightcomputing.com
nameserver 10.141.255.254

[node002] :
# This file was generated by the Node Installer.
search cm.cluster eth.cluster brightcomputing.com
nameserver 10.141.255.254
```

More order can be imposed on the preceding output by using the `-j|--join` option. This joins identical fields together in a way similar to the standard unix text utility, `join`, which makes the result easier to view:

**Example**

```bash
[basecm11->device]% pexec -j -c default "cat /etc/resolv.conf"
[node001,node002]
# This file was generated by the Node Installer.
search cm.cluster eth.cluster brightcomputing.com
nameserver 10.141.255.254
```

In the following example, a cluster with 10 nodes is inspected. In the cluster, `node002` is down, and the idea is to see if the remaining nodes have the same mounts:

**Example**

```bash
[basecm11->device]% pexec -j -c default "mount|sort"
Nodes down:         node002
[node002]
Node down

[node001,node003..node010]
/dev/hda1 on / type ext3 (rw,noatime,nodiratime)
/dev/hda2 on /var type ext3 (rw,noatime,nodiratime)
/dev/hda3 on /tmp type ext3 (rw,nosuid,nodev,noatime,nodiratime)
/dev/hda6 on /local type ext3 (rw,noatime,nodiratime)
master:/cm/shared on /cm/shared type nfs
(rw,rsize=32768,wsize=32768,hard,intr,addr=10.141.255.254)
master:/home on /home type nfs
(rw,rsize=32768,wsize=32768,hard,intr,addr=10.141.255.254)
none on /dev/pts type devpts (rw,gid=5,mode=620)
none on /dev/shm type tmpfs (rw)
none on /proc/sys/fs/binfmt_misc type binfmt_misc (rw)
none on /proc type proc (rw,nosuid)
none on /sys type sysfs (rw)
```

Here, even more order is imposed by sorting the output of each mount command within `bash` before the `-j` option operates from `cmsh`. The `-c` option executes the command on the `default` category of nodes.

### 14.1.5  Other Parallel Commands

Besides `pexec`, CMDaemon has several other parallel commands:

**pkill**: parallel kill\
Synopsis:\
`pkill [OPTIONS]` \<*tracker*>` [<`*tracker*> …` ]`

**plist**: List the parallel commands that are currently running, with their tracker ID\
Synopsis:\
`plist`

**pping**: ping nodes in parallel\
Synopsis:\
`pping [OPTIONS]`

**pwait**: wait for parallel commands that are running to complete\
Synopsis:\
`pwait [OPTIONS]` \<*tracker*>` [<`*tracker*> …`]`

Details on these parallel commands, including examples, can be seen by executing the `help` command within the `device` mode of `cmsh` for a parallel command, \<*pcommand*>, as follows:

`[basecm11->device]%``help` \<*pcommand*>

## 14.2  Getting Support With BCM Issues, And Notifications For Release Updates

The scope of BCM technical support is described in [Appendix C of the *Installation Manual*](/installation/bcmsupport).

### 14.2.1  The Support Portal For BCM

Support requests can be sent in via the support portal at

[https://enterprise-support.nvidia.com/s/create-case](https://enterprise-support.nvidia.com/s/create-case)

![Customer support portal: submitting a support request](/base-command-manager/product-manuals/_fern-img/c3cdbced031e963c31775dc1d05294be72f7e4fd1f45ddd08673976c3574c355.webp)

*Figure 14.1: Customer support portal: submitting a support request*

When creating a BCM support case at that URL:

* the `Product Type` that must be selected is `Software`.

* the `Product Category` that must be selected is:

  * `Bright Cluster Manager` for issues related to versions of BCM prior to BCM version 10.

  * `Base Command Manager` for issues related to BCM version 10 and beyond.

* Registered users are advised to log in to the support portal. It makes the user experience better because cluster-related data values are already filled in for a logged-in user.

* Unregistered users can also create a case via the same URL, to deal with registration issues.

The Enterprise Support Portal User Guide at

[https://enterprise-support.nvidia.com/s/article/NVIDIA-Enterprise-Support-Guide-for-New-Users](https://enterprise-support.nvidia.com/s/article/NVIDIA-Enterprise-Support-Guide-for-New-Users)

has further details on how users can submit support requests.

BCM support as implemented via the support portal is carried out primarily via e-mail. To help resolve issues, the `cm-diagnose` (section [14.2.2](#1422-reporting-cluster-manager-diagnostics-with-cm-diagnose)) utility is provided as a supplement, and is discussed next.

### 14.2.2  Reporting Cluster Manager Diagnostics With `cm-diagnose`

The diagnostic utility `cm-diagnose` is run from the head node. It gathers data on the cluster that may help diagnose issues. Running it as

`cm-diagnose --help`

displays its options, capabilities, and defaults.

For particular issues it may be helpful to change some of the default values to gather data in a more targeted way. For example, for larger clusters, the log file limit and the timeout values can both be increased to avoid logs being cropped and commands being killed during the gathering of diagnostic data:

**Example**

```bash
[root@basecm11 ~]# cm-diagnose --limit 100 --timeout 240
```

The preceding command increases the log limit from its default of `50`MB to `100`MB, and the timeout value from its default of `60`s to `240`s.

When carrying out a run to pick up diagnostic data, `cm-diagnose` runs interactively by default. The administrator can send the resultant diagnostics file to BCM support directly. The output of a `cm-diagnose` session looks something like the following (the output has been made less verbose for easy viewing):

**Example**

```bash
[root@basecm11 ~]# cm-diagnose
To be able to contact you about the issue, please provide
your e-mail address (or support ticket number, if applicable):
franknfurter@example.com

Please enter the related Support Request (SR) or NVIDIA Enterprise Support number and any other
related additional information: [SR-XXXXX] or [XXXXXXXX]
End input with ctrl-d
This has to do with SR-999999 that I submitted just now. In short:
I tried X, Y, and Z on the S2464 motherboard. When that didn't work, I
tried A, B, and C, but the florbish is grommicking.
Thank you.

Support Request number: SR-999999
Thank you.
If issues are suspected in the cmdaemon process, a gdb trace of that process
is useful. In general such trace is only needed if Bright Support asks for this.
Do you want to create a gdb trace of the running CMDaemon? [y/N]

Proceed to collect information? [Y/n]

Processing master
    Processing commands
        /bin/uname -a
        /usr/bin/top -b -n 1
        /sbin/ifconfig -a
        ...
    Processing file contents
        ...
    Processing large files and log files
        ...
    Collecting process information for CMDaemon
        gdb -p 1334
    Executing CMSH commands
        ...
    Finished executing CMSH commands

Processing default-image
    Processing commands
        ...
    Processing file contents
        ...
Creating log file: /root/SR-999999-basecm11__1234.tar.gz

Cleaning up

Automatically submit diagnostics file to http://support.brightcomputing.com/cm-diagnose/ ? [Y/n]

Uploaded file: SR-999999-basecm11__1234.tar.gz
Remove log file (/root/SR-999999-basecm11__1234.tar.gz)?  [y/N] y
[root@basecm11 ~]#
```

### 14.2.3  Getting Notified About Updates

Updates for the various NVIDIA Base Command Manager releases continue for some time after the initial release is made public. The updates typically have bugfixes and improvements, and an administrator may wish to install an update when it becomes publicly available.

The release notes for BCM can be found online at:

[https://docs.nvidia.com/base-command-manager/#release-notes](https://docs.nvidia.com/base-command-manager/#release-notes)

## 14.3  Backups

### 14.3.1  Cluster Installation Backup

BCM does not include facilities to create backups of a cluster installation. The cluster administrator is responsible for deciding on the best way to back up the cluster, out of the many possible choices.

A backup method is strongly recommended, and checking that restoration from backup actually works is also strongly recommended.

One option that may be appropriate for some cases is simply cloning the head node. A clone can be created by PXE booting the new head node, and following the procedure in section [15.4.8](/admin/ha#1548-re-cloning-a-head-node).

When setting up a backup mechanism, it is recommended that the full filesystem of the head node (i.e. including all software images) is backed up. Unless the regular node hard drives are used to store important data, it is not necessary to back them up.

If no backup infrastructure is already in place at the cluster site, the following open source (GPL) software packages may be used to maintain regular backups:

* **Bacula**: Bacula is a mature network based backup program that can be used to backup to a remote storage location. If desired, it is also possible to use Bacula on nodes to back up relevant data that is stored on the local hard drives. More information is available at [http://www.bacula.org](http://www.bacula.org)

  Bacula requires ports 9101-9103 to be accessible on the head node. The ports can be opened from an IP address of 93.184.216.34 on the external network using the `openports` mode of the `firewall` role in `cmsh`:

  **Example**

  ```bash
  [basecm11->device[basecm11]->roles[firewall]->openports]% add ACCEPT net 9101 tcp fw 93.184.216.34/32
  [basecm11->device[basecm11]->roles[firewall]->openports]% add ACCEPT net 9102 tcp fw 93.184.216.34/32
  [basecm11->device[basecm11]->roles[firewall]->openports]% add ACCEPT net 9103 tcp fw 93.184.216.34/32
  [basecm11->device[basecm11]->roles[firewall]->openports]% commit
  ```

  The `shorewall` service is restarted automatically to enforce the added rules.

* **rsnapshot**: rsnapshot allows periodic incremental filesystem snapshots to be written to a local or remote filesystem. Despite its simplicity, it can be a very effective tool to maintain frequent backups of a system. More information is available at [http://www.rsnapshot.org](http://www.rsnapshot.org).

  Rsnapshot requires access to port 22 on the head node.

### 14.3.2  Local Database And Data Backups And Restoration

The CMDaemon database is stored in the MySQL `cmdaemon` database, and contains most of the stored settings of the cluster.

Monitoring data values are stored as binaries in the filesystem, under `/var/spool/cmd/monitoring`.

The administrator is expected to run a regular backup mechanism for the cluster to allow restores of all files from a recent snapshot. As an additional, separate, convenience:

* For the CMDaemon database:

  * the entire database is, by default, also backed up nightly on the cluster filesystem itself (“local rotating backup”) for the last 7 days:

    **Example**

    ```bash
            [root@basecm11 ~]# ls -1t /var/spool/cmd/backup/
    backup-Wed.sql.gz
    backup-Tue.sql.gz
    backup-Mon.sql.gz
    backup-Sun.sql.gz
    backup-Sat.sql.gz
    backup-Fri.sql.gz
    backup-Thu.sql.gz
    ```

  * the CMDaemon database can also be manually backed up with the `cmdaemon-backup` command. This can be useful if the administrator would like to carry out an extensive change on the cluster and would like the reassuring possibility of getting back the old configuration. If no argument is supplied to `cmdaemon-backup`, then any existing default backup of the day is overwritten. If a string is supplied, then the default `backup-` prefix is replaced. The replacement becomes the supplied string concatenated with a timestamp. This is most easily illustrated with an example:

    **Example**

    ```bash
            [root@basecm11 ~]# cmdaemon-backup manual
            [root@basecm11 ~]# ls /var/spool/cmd/backup/manual*
                    manual-24-08-28_13-19-59_Wed.sql.gz
    ```

    The time stamp in the preceding example is of the form:

    -\<*two-digit year*>-\<*month*>-\<*date*>\_\<*hour*>-\<*minute*>-\<*seconds*>\_

* For the monitoring data, the raw data records are not backed up locally, since these can get very large. However, the configuration of the monitoring data, which is stored in the CMDaemon database, is backed up for the last 7 days too.

#### 14.3.2.1  Database Corruption Messages

A corrupted MySQL database is commonly caused by an improper shutdown of the node. To deal with this, when starting up, MySQL checks itself for corrupted tables, and tries to repair itself.

* If MySQL cannot start, then CMDaemon on the head node cannot start.

* If MySQL can start, but corruption is detected in the database later on, then it keeps running in read-only mode. The `mysql` health check on the head node fails, and an `info` message (section [10.10.4](/admin/monitoring#10104-infomessages)) with an indication of the issue is seen. More details can be found in `/var/log/cmdaemon` and using `service status mysql.service` or `journalctl -xeu mysql.service`.

  The `journalctl` output might show something similar to the following output extract, if corruption is detected in the data (some output ellipsized):

  **Example**

  ```bash
  [root@basecm11 ~]# journalctl -xeu mysql.service
  ...
  mysqld[179281]:..546 [ERROR] [MY-012224] [InnoDB] Checksum mismatch in datafile: ./cmdaemon/....
  mysqld[179281]:..546 [ERROR] [MY-012592] [InnoDB] Operating system error number 22 in a file....
  mysqld[179281]:..546 [ERROR] [MY-012596] [InnoDB] Error number 22 means 'Invalid argument'  ...
  mysqld[179281]:..546 [ERROR] [MY-012131] [InnoDB] Could not find a valid tablespace file for....
  mysqld[179281]:..546 [Warning] [MY-012049] [InnoDB] Cannot calculate statistics for table `c....
  mysqld[179281]:..1192 [Warning] [MY-012049] [InnoDB] Cannot calculate statistics for table `....
  mysqld[179281]:..1838 [ERROR] [MY-012224] [InnoDB] Checksum mismatch in datafile: ./cmdaemon....
  mysqld[179281]:..1838 [ERROR] [MY-012592] [InnoDB] Operating system error number 22 in a fil....
  mysqld[179281]:..1838 [ERROR] [MY-012596] [InnoDB] Error number 22 means 'Invalid argument' ...
  mysqld[179281]:..1838 [ERROR] [MY-012131] [InnoDB] Could not find a valid tablespace file fo....
  mysqld[179281]:..1838 [Warning] [MY-012049] [InnoDB] Cannot calculate statistics for table `....
  mysqld[179281]:..2485 [Warning] [MY-012049] [InnoDB] Cannot calculate statistics for table `....
  mysqld[179281]:..3131 [Warning] [MY-012049] [InnoDB] Cannot calculate statistics for table `....
  mysqld[179281]:..3778 [ERROR] [MY-012224] [InnoDB] Checksum mismatch in datafile: ./cmdaemon....
  mysqld[179281]:..3778 [ERROR] [MY-012592] [InnoDB] Operating system error number 22 in a fil....
  ```

A corrupt database can continue to run for a while, as write attempts pile up in cache. However, eventually the database crashes and then BCM and other systems that rely on the database cannot carry on. Preventing a database crash is therefore important, which is why automatic checks and repairs are carried out when a database starts up.

To fix a corrupted database, a restoration from backup can be carried out, as explained in the next section.

#### 14.3.2.2  Restoring From The Local Backup

If the MySQL InnoDB repair tools do not automatically fix the problem, then the issue can normally be resolved with some manual intervention for a failover or non-failover configuration.

If the head node is a part of a failover configuration, the `dbreclone` option (section [15.4.2](/admin/ha#1542-cmha-utility)) should normally provide a CMDaemon and Slurm database that is current. The `dbreclone` option does not clone the monitoring data.

**Cloning extra databases:** The file `/cm/local/apps/cluster-tools/ha/conf/extradbclone.xml.template` can be used as a template to create a file `extradbclone.xml` in the same directory. The `extradbclone.xml` file can then be used to define an additional database to be cloned.

The `/etc/my.cnf` file can then be updated with a new database by adding the lines:

```bash
        replicate-do-db=<name of database>
        binlog-do-db=<name of database>
```

The database can then be cloned with this new MySQL configuration by running `cmha dbreclone` \<*passive*>\
where \<*passive*> is the hostname of the passive head node.

If the head node is not part of a failover configuration, then a restoration from local backup can be done. The local backup directory is `/var/spool/cmd/backup`, with contents that look like (some text elided):

**Example**

```bash
[root@solaris ~]# cd /var/spool/cmd/backup/
[root@solaris backup]# ls -l
total 280
...
-rw------- 1 root root 33804 Oct 10 04:02 backup-Mon.sql.gz
-rw------- 1 root root 33805 Oct  9 04:02 backup-Sun.sql.gz
-rw------- 1 root root 33805 Oct 11 04:02 backup-Tue.sql.gz
...
```

The CMDaemon database snapshots are stored as `backup-` \<*`day of week`*>`.sql.gz` In the example, the latest backup available in the listing for CMDaemon turns out to be `backup-Tue.sql.gz`

The latest backup can then be ungzipped and piped into the MySQL database for the user `cmdaemon`. The password, \<*password*>, can be retrieved from `/cm/local/apps/cmd/etc/cmd.conf`, where it is configured in the `DBPass` directive (Appendix [C.18](/admin/cmdconf#c18-dbpass-directive)).

**Example**

`gunzip backup-Tue.sql.gz`\
`systemctl stop cmd #(just to make sure)`\
`mysql -ucmdaemon -p` \<*`password`*>` cmdaemon < backup-Tue.sql`

Running “`systemctl start cmd`” should have CMDaemon running again, this time with a restored database from the time the snapshot was taken. That means, that any changes that were done to BCM after the time the snapshot was taken are no longer implemented.

Monitoring data values are not kept in a database, but in files (section [14.8](#148-managing-raw-monitoring-data)).

## 14.4  Revision Control For Images

BCM version 7 introduced support for the implementations of Btrfs provided by the distributions. Btrfs makes it possible to carry out revision control for images efficiently.

### 14.4.1  Btrfs: The Concept And Why It Works Well In Revision Control For Images

Btrfs, often pronounced “butter FS”, is a Linux implementation of a copy-on-write (COW) filesystem.

A COW design for a filesystem follows the principle that, when blocks of old data are to be modified, then the new data blocks are written in a new location (the COW action), leaving the old, now superseded, copy of the data blocks still in place. Metadata is written to keep track of the event so that, for example, the new data blocks can be used seamlessly with the contiguous old data blocks that have not been superseded.

This is in contrast to the simple overwriting of old data that a non-COW filesystem such as Ext3fs carries out.

A result of the COW design means that the old data can still be accessed with the right tools, and that rollback and modification become a natural possible feature.

“Cheap” *revision control* is thus possible.

Revision control for the filesystem is the idea that changes in the file system are tracked and can be rolled back as needed. “Cheap” here means that COW makes tracking changes convenient, take up very little space, and quick. For an administrator of BCM, cheap revision control is interesting for the purpose of managing software images.

This is because for a non-COW filesystem such as Ext3fs, image variations take a large amount of space, even if the variation in the filesystem inside the image is very little. On the other hand, image variations in a COW filesystem such as Btrfs take up near-minimum space.

Thus, for example, the technique of using initialize and finalize scripts to generate such image variations on the fly (section [3.20.4](/admin/configuring#3204-adding-functionality-to-nodes-via-an-initialize-or-finalize-script)) in order to save space, can be avoided by using a Btrfs partition to save the full image variations instead.

“Expensive” revision control on non-COW filesystems is also possible. It is merely not recommended, since each disk image takes up completely new blocks, and hence uses up more space. The administrator will then have to consider that the filesystem may become full much earlier. The degree of restraint on revision control caused by this, as well as the extra consumption of resources, means that revision control on non-COW filesystems is best implemented on test clusters only, rather than on production clusters.

### 14.4.2  Btrfs Availability And Distribution Support

Btrfs has been part of the Linux kernel since kernel 2.6.29-rc1. Depending on which Linux distribution is being used on a cluster, it may or may not be a good idea to use Btrfs in a production environment, as in the worst case it could lead to data loss.

Btrfs has been officially removed from RHEL distributions since RHEL8.

Btrfs features are supported in SLES15, as described at [https://www.suse.com/releasenotes/x86_64/SUSE-SLES/15-SP1/index.html#TechInfo.Filesystems](https://www.suse.com/releasenotes/x86_64/SUSE-SLES/15-SP1/index.html#TechInfo.Filesystems).

While no problems have been noticed with storing software images on Btrfs using BCM, it is highly advisable to keep backups of important software images on a non-Btrfs filesystem when Btrfs is used.

An issue with using `cm-clone-install` with Btrfs is described [here](/admin/ha#15483-btrfs-and-cm-clone-install).

### 14.4.3  Installing Btrfs To Work With Revision Control Of Images In BCM

#### 14.4.3.1  Installation Of `btrfs-progs`

To install a Btrfs filesystem, the `btrfs-progs` packages must be installed from the distribution repository first (some lines elided):

**Example**

```bash
[root@basecm11 ~]# yum install btrfs-progs
...
Resolving Dependencies
--> Running transaction check
---> Package btrfs-progs.x86_64 0:4.9.1-1.el7 will be installed
...
Total download size: 678 k
Installed size: 4.0 M
...
Complete!
```

#### 14.4.3.2  Creating A Btrfs Filesystem

The original images directory can be moved aside first, and a new images directory created to serve as a future mount point for Btrfs:

**Example**

```bash
[root@basecm11 ~]# cd /cm/
[root@basecm11 cm]# mv images images2
[root@basecm11 cm]# mkdir images
```

A block device can be formatted as a Btrfs filesystem in the usual way by using the `mkfs.btrfs` command on a partition, and then mounted to the new images directory:

**Example**

```bash
[root@basecm11 cm]# mkfs.btrfs /dev/sdc1
[root@basecm11 cm]# mount /dev/sdc1 /cm/images
```

If there is no spare block device, then, alternatively, a file with zeroed data can be created, formatted as a Btrfs filesystem, and mounted as a loop device like this:

**Example**

```bash
[root@basecm11 cm]# dd if=/dev/zero of=butter.img bs=1G count=20
20+0 records in
20+0 records out
21474836480 bytes (21 GB) copied, 916.415 s, 23.4 MB/s
[root@basecm11 cm]# mkfs.btrfs butter.img

WARNING! - Btrfs Btrfs v0.20-rc1 IS EXPERIMENTAL
WARNING! - see http://btrfs.wiki.kernel.org before using

fs created label (null) on butter.img
        nodesize 4096 leafsize 4096 sectorsize 4096 size 20.00GB
Btrfs Btrfs v0.20-rc1
[root@basecm11 cm]# mount -t btrfs butter.img images -o loop
[root@basecm11 cm]# mount
...
/cm/butter.img on /cm/images type btrfs (rw,loop=/dev/loop0)
```

#### 14.4.3.3  Migrating Images With `cm-migrate-images`

The entries inside the `/cm/images/` directory are the software images (file trees) used to provision nodes.

Revision tracking of images in a Btrfs filesystem can be done by making the directory of a specific image a *subvolume*. Subvolumes in Btrfs are an extension of standard unix directories with versioning. The files in a subvolume are tracked with special internal Btrfs markers.

To have this kind of version tracking of images work, image migration cannot simply be done with a `cp -a` or a `mv` command. That is, moving images from the`images2` directory in the traditional filesystem, over to images in the `images` directory in the Btrfs filesystem command with the standard `cp` or `mv` command is not appropriate. This is because the images are to be tracked once they are in the Btrfs system, and are therefore not standard files any more, but instead extended, and made into subvolumes.

The migration for BCM software images can be carried out with the utility `cm-migrate-image`, which has the usage:

`cm-migrate-image` \<*`path to old image`*>` <`*`path to new image`*>

where the old image is a traditional directory, and the new image is a subvolume.

**Example**

```bash
[root@basecm11 cm]# cm-migrate-image /cm/images2/default-image /cm/images/default-image
```

The `default-image` directory, or more exactly, subvolume, must not exist in the Btrfs filesystem before the migration. The subvolume is created only for the image basename that is migrated, which is `default-image` in the preceding example.

In the OS, the `btrfs` utility is used to manage Btrfs. Details on what it can do can be seen in the `btrfs(8)` man page. The state of the loop filesystem can be seen, for example, with:

**Example**

```bash
[root@basecm11 cm]# btrfs filesystem show /dev/loop0
Label: none  uuid: 6f94de75-2e8d-45d2-886b-f87326b73474
        Total devices 1 FS bytes used 3.42GB
        devid    1 size 20.00GB used 6.04GB path /dev/loop0

Btrfs Btrfs v0.20-rc1
[root@basecm11 cm]# btrfs subvolume list /cm/images
ID 257 gen 482 top level 5 path default-image
```

The filesystem can be modified as well as merely viewed with `btrfs`. However, instead of using the utility to modify image revisions directly, it is recommended that the administrator use BCM to manage image version tracking, since the necessary functionality has been integrated into `cmsh` and Base View.

### 14.4.4  Using `cmsh` For Revision Control Of Images

#### 14.4.4.1  Revision Control Of Images Within `softwareimage` Mode

The following commands and extensions can be used for revision control in the `softwareimage` mode of `cmsh`:

* `newrevision` \<*parent software image name*>` "`*textual description*`"`\
  Creates a new revision of a specified software image. For that new revision, a revision number is automatically generated and saved along with time and date. The new revision receives a name of the form:

  * \<*parent software image name*>`@<`*revision number*>

  A new Btrfs subvolume:

  * `/cm/images/` \<*parent software image name*>`-<`*revision number*>

  is created automatically for the revision. From now on, this revision is a self-contained software image and can be used as such.

* `revisions [-a|--all]` \<*parent software image name*>\
  Lists all revisions of specified parent software image in the order they ware created, and associates the revision with the revision number under the header `ID`. The option `-a|--all` also lists revisions that have been removed.

* `list [-r|--revisions]`\
  The option `-r|--revisions` has been added to the `list` command. It lists all revisions with their name, path, and kernel version. A parent image is the one at the head of the list of revisions, and does not have `@` \<*revision number*> in its name.

* `setparent [`*parent software image name*`]` \<*revision name*>\
  Sets a revision as a new parent. The action first saves the image directory of the current, possibly altered, parent directory or subvolume, and then attempts to copy or snapshot the directory or subvolume of the revision into the directory or subvolume of the parent. If the attempt fails, then it tries to revert all the changes in order to get the directory or subvolume of the parent back to the state it was in before the attempt.

* `remove [-a|--all] [-d|--data]` \<*parent software image name*>\
  Runnning `remove` without options removes the parent software image. The option `-a|--all` removes the parent and all its revisions. The option `-d|--data` removes the actual data. To run the `remove` command, any images being removed should not be in use.

#### 14.4.4.2  Revision Control Of Images Within `category` Mode

The `category` mode of `cmsh` also supports revision control.

Revision control can function in 3 kinds of ways when set for the `softwareimage` property at category level.

To explain the settings, an example can be prepared as follows: It assumes a newly-installed cluster with Btrfs configured and `/cm/images` migrated as explained in section [14.4.3](#1443-installing-btrfs-to-work-with-revision-control-of-images-in-bcm). The cluster has a default software image `default-image`, and two revisions of the parent image are made from it. These are automatically given the paths `default-image@1` and `default-image@2`. A category called `storage` is then created:

**Example**

```bash
[basecm11->softwareimage]% newrevision default-image "some changes"
[basecm11->softwareimage]% newrevision default-image "more changes"
[basecm11->softwareimage]% revisions default-image
ID    Date                           Description
----- ------------------------------ ------------------------------
1     Fri, 04 Oct 2019 11:19:33 CEST some changes
2     Fri, 04 Oct 2019 11:19:52 CEST more changes
[basecm11->softwareimage]% list -r
Name (key)       Path                       Kernel version
---------------- -------------------------- --------------------------
default-image    /cm/images/default-image   3.10.0-957.1.3.el7.x86_64
default-image@1  /cm/images/default-image-1 3.10.0-957.1.3.el7.x86_64
default-image@2  /cm/images/default-image-2 3.10.0-957.1.3.el7.x86_64
[basecm11->softwareimage]% category add storage; commit
```

With the cluster set up like that, the 3 kinds of revision control functionalities in `category` mode can be explained as follows:

1. **Category revision control functionality is defined as unset**\
   If the administrator sets the `softwareimage` property for the category to an image without any revision tags:

   **Example**

   ```bash
   [basecm11->category]% set storage softwareimage default-image
   ```

   then nodes in the `storage` category take no notice of the revision setting for the image set at category level.

2. **Category revision control sets a specified revision as default**\
   If the administrator sets the `softwareimage` property for the category to a specific image, with a revision tag, such as `default-image@1`:

   **Example**

   ```bash
   [basecm11->category]% set storage softwareimage default-image@1
   ```

   then nodes in the `storage` category use the image `default-image@1` as their image if nothing is set at node level.

3. **Category revision control sets the latest available revision by default**\
   If the administrator sets the `softwareimage` property for the category to a parent image, but tagged with the reserved keyword tag `latest`:

   **Example**

   ```bash
   [basecm11->category]% set storage softwareimage default-image@latest
   ```

   then nodes in the `storage` category use the image `default-image@2` if nothing is set at node level. If a new revision of `default-image` is created later on, with a later tag (`@3`, `@4`, `@5`...) then the property takes the new value for the revision, so that nodes in the category will use the new revision as their image.

#### 14.4.4.3  Revision Control For Images—An Example Session

This section uses a session to illustrate how image revision control is commonly used, with commentary along the way. It assumes a newly installed cluster with Btrfs configured and `/cm/images` migrated as explained in section [14.4.3](#1443-installing-btrfs-to-work-with-revision-control-of-images-in-bcm).

First, a revision of the image is made to save its initial state:

```bash
[basecm11->softwareimage]% newrevision default-image "Initial state"
```

A new image `default-image@1` is automatically created with a path `/cm/images/default-image-1`. The path is also a subvolume, since it is on a Btrfs partition.

The administrator then makes some modifications to the parent image `/cm/images/default-image`, which can be regarded as a “trunk” revision, for those familiar with SVN or similar revision control systems. For example, the administrator could install some new packages, edit some configuration files, and so on. When finished, a new revision is created by the administrator:

```bash
[basecm11->softwareimage]% newrevision default-image "Some modifications"
```

This image is then automatically called `default-image@2` and has the path `/cm/images/default-image-2`. If the administrator then wants to test the latest revision on nodes in the `default` category, then this new image can be set at category level, without having to specify it for every node in that category individually:

```bash
[basecm11->category]% set default softwareimage default-image@2
```

At this point, the content of `default-image` is identical to `default-image@2`. But changes done in `default-image` will not affect what is stored in revision `default-image@2`.

After continuing on with the parent image based on the revision `default-image@2`, the administrator might conclude that the modifications tried are incorrect or not wanted. In that case, the administrator can roll back the state of the parent image `default-image` back to the state that was previously saved as the revision `default-image@1`:

```bash
[basecm11->softwareimage]% setparent default-image default-image@1
```

The administrator can thus continue experimenting, making new revisions, and trying them out by setting the `softwareimage` property of a category accordingly. Previously created revisions `default-image@1` and `default-image@2` will not be affected by these changes. If the administrator would like to completely purge a specific unused revision, such as `default-image@2` for example, then it can be done with the `-d|--data` option:

```bash
[basecm11->softwareimage]% remove -d default-image@2
```

The `-d` does a forced recursive removal of the `default-image-2` directory, while a plain `remove` without the `-d` option would simply remove the object from CMDaemon, but leave `default-image-2` alone. This CMDaemon behavior is not unique for Btrfs—it is true for traditional filesystems too. It is however usually very wasteful of storage to do this with non-COW systems.

## 14.5  BIOS And Firmware Management

### 14.5.1  Introduction

The main PC BIOS firmware is nowadays a subset of the more general firmware of a system. In older versions of BCM, BIOS and firmware management relied on proprietary vendor implementations. While such legacy implementations are still in use at the time of writing of this section (December 2023), the modern way of managing BIOS and firmware is with the Redfish standard.

The Redfish standard is an industry API standard intended for RESTful management of large numbers of nodes. It is supported by Dell, HPE, Intel, and others.

Redfish uses a pluggable framework architecture with JSON. This makes adding new properties easier, and also makes isolating, debugging, and fixing issues easier.

The CMDaemon front ends of `cmsh` and Base View provide a front end for BIOS and firmware management via Redfish.

### 14.5.2  BIOS Management With BCM JSON Configuration Templates In Redfish

For BIOS management via Redfish, the JSON configuration is specified per vendor. In BCM the files are kept under:

`/cm/local/apps/cm-bios-tools/templates/`

By default, BCM ships with the following configuration file templates:

* `dell_14g.json`

* `dell_15g-amd.json`

* `dell_15g-intel.json`

* `dell_r730.json`

* `hpe_dl110.json`

* `hpe_dl380g10.json`

**Example**

```bash
[root@basecm11 ~]# ls -al /cm/local/apps/cm-bios-tools/templates/
total 280
drwxr-xr-x 2 root root    148 Nov 15 08:24 .
drwxr-xr-x 6 root root     64 Nov 15 08:24 ..
-rw-r--r-- 1 root root   5008 Oct 25 19:24 dell_14g.json
-rw-r--r-- 1 root root   6411 Oct 25 19:24 dell_15g-amd.json
-rw-r--r-- 1 root root  20493 Oct 25 19:24 dell_15g-intel.json
-rw-r--r-- 1 root root   7052 Oct 25 19:24 dell_r730.json
-rw-r--r-- 1 root root 211366 Oct 25 19:24 hpe_dl110.json
-rw-r--r-- 1 root root  24448 Oct 25 19:24 hpe_dl380g10.json
[root@basecm11 templates]# cat dell_r730.json
```

```bash
{
  "displayName": "Dell Inc. - PowerEdge R730",
  "description": "Dell Inc. - PowerEdge R730 - BIOS settings template - v1.0.0",
  "properties": [
    {
      "name": "BootMode",
      "displayName": "Boot Mode",
      "description": "This field determines the boot mode of the system.\n\nSelecting 'UEFI' enables\
      booting to Unified Extensible Firmware Interface (UEFI) capable operating systems.\n\nSelecting\
      'BIOS' (the default) ensures compatibility with operating systems that do not support UEFI.",
      "type": "Enumeration",
      "options": [
        {
          "displayName": "BIOS",
          "value": "Bios"
        },
        {
          "displayName": "UEFI",
          "value": "Uefi"
        }
      ],
      "pos": {
        "g": 0,
        "r": 0,
        "o": 0,
        "w": 6
      }
    },
    {
      "name": "NodeInterleave",
      "displayName": "Node Interleaving",
      "description": "When set to Enabled, memory interleaving is supported if a symmetric memory\
      configuration is installed. When set to Disabled, the system supports Non-Uniform Memory Access\
      (NUMA) (asymmetric) memory configurations.\n\nOperating Systems that are NUMA-aware understand the\
      distribution of memory in a particular system and can intelligently allocate memory in an optimal\
      manner. Operating Systems that are not NUMA aware could allocate memory to a processor that is not\
      local resulting in a loss of performance. Node Interleaving should only be enabled for Operating\
      Systems that are not NUMA aware.\n\nDefault: Disabled",
      "type": "Enumeration",
      "options": [
        {
          "displayName": "Enabled",
          "value": "Enabled"
        },
        {
          "displayName": "Disabled",
          "value": "Disabled"
        }
      ],
      "pos": {
        "g": 0,
        "r": 0,
        "o": 1,
        "w": 6
      }
    },
    {
      "name": "SnoopMode",
      "displayName": "Snoop Mode",
      "description": "Allows tuning of memory performances under different memory bandwidths. The optimal\
      Snoop Mode setting is highly dependent on workload type.\n\nEarly Snoop is best used for latency sensitive\
      workloads. This setting offers the best balance between workload effects.\n\nHome Snoop is best used for\
      NUMA workloads that need maximum local and remote memory bandwidth.\n\nCluster on Die is best used for\
      highly NUMA optimized workloads. This setting offers the best case local memory latency, but worst case\
      remote latency.\n\nCluster On Die is only available when Node Interleaving is Disabled.\n\nOpportunistic\
      Snoop Broadcast, available on select processor models, works well for workloads of mixed NUMA optimization.\
      It offers a good balance of latency and bandwidth.\n\nDefault: Early Snoop",
      "type": "Enumeration",
      "options": [{
          "displayName": "Early Snoop",
          "value": "EarlySnoop"
        },
...
```

#### 14.5.2.1  BCM BIOS Configuration States And Operations Overview

In BCM, a BIOS configuration of a node or category can be thought of as being in one of 4 possible states, with 3 possible operations that apply the changes to the states. This is shown by the following schematic:

```bash

cmsh or       commit                        bios apply                     reboot
Base View  --------------> CMDaemon database -----------> BIOS (pending) -----------> BIOS (live)
```

For example, the cluster administrator might adjust the BIOS configuration for the node or category in `cmsh`. The state set within `cmsh` then becomes a state stored within the CMDaemon database after the `commit` operation of `cmsh` is carried out.

The cluster administrator can then apply the BIOS configuration that is stored in the CMDaemon database by running the `bios apply` operation from within `cmsh`. The BIOS configuration is then taken up as the `BIOS (pending)` state stored in the BIOS firmware of the node (or category).

Finally, the cluster administrator can implement the BIOS, so that it runs on the live node (or category). This happens when carrying out a `reboot` operation for that node (or category). The BIOS configuration that was a pending BIOS setting then becomes a live BIOS setting.

The details of how these changes can be carried out are explained in the following sections.

#### 14.5.2.2  Example BIOS Configuration Session In `cmsh`

In `cmsh`, the BIOS settings can be viewed, compared, and applied at the `device` mode level or `category` mode level.

The BIOS settings for the various states can alternatively be managed using the `cm-bios-manage` utility ([here](#14523-bios-configuration-via-cm-bios-manage)). However the `cmsh` or Base View front ends to `cm-bios-manage` are easier to use. **Model:** The model must be set for the BIOS settings before other BIOS settings can be managed. If it is not set, then the `status` command in `biossettings` displays an error, as indicated by the following `cmsh` session:

**Example**

```bash
[basecm11->device[node002]->biossettings]% status
Parameter                        Configured Pending Live
-------------------------------- ---------- ------- ----
Pending errors:
No model defined
```

It can be set with the help of tab-completion:

**Example**

```bash
[basecm11->device[node002]->biossettings]% set model<tab><tab>
dell_r730  hpe_dl380
[basecm11->device[node002]->biossettings]% set model hpe_dl380
[basecm11->device*[node002*]->biossettings*]% commit
```

**Viewing BIOS parameters:** Each BIOS parameter can now have its value listed and compared by state.

The `status` command shows a list of the parameters, and their values are displayed for each state. So, the state columns show:

1. the BIOS parameter as stored in the CMDaemon database (the `Configured` column),

2. the BIOS parameter as stored on the node itself (the `Pending` column),

3. the BIOS parameter as implemented on the node itself (the `Live` column)

**Example**

```bash
[basecm11->device[node002]]% biossettings
[basecm11->device[node002]->biossettings]% status
Parameter                                       Configured     Pending Live
----------------------------------------------- -------------- ------- -----------------------------
High Precision Event Timer (HPET) ACPI Support  < default >    -       Enabled
Adjacent Sector Prefetch                        < default >    -       Enabled
Boot Mode                                       < default >    -       UEFI Mode
Boot Order Policy                               < default >    -       Retry Boot Order Indefinitely
Channel Interleaving                            < default >    -       Enabled
Collaborative Power Control                     < default >    -       Enabled
Consistent Device Naming                        < default >    -       CDN Support for LOMs and Slots
Custom POST Message                             < default >    -
LLC Prefetch                                    < default >    -       Disabled
Local/Remote Threshold                          < default >    -       Auto
Maximum Memory Bus Frequency                    < default >    -       Auto
Maximum PCI Express Speed                       < default >    -       Per Port Control
Memory Mirroring Mode                           < default >    -       Full Mirror
Memory Patrol Scrubbing                         < default >    -       Enabled
Memory Refresh Rate                             < default >    -       1x Refresh
Minimum Processor Idle Power Package C-State    < default >    -       Package C6 (retention) State
Minimum Processor Idle Power Core C-State       < default >    -       C6 State
Mixed Power Supply Reporting                    < default >    -       Enabled
Network Boot Retry Support                      < default >    -       Enabled
Node Interleaving                               < default >    -       Disabled
NUMA Group Size Optimization                    < default >    -       Flat
Embedded NVM Express Option ROM                 < default >    -       Enabled
NVMe PCIe Resource Padding                      < default >    -       Normal
Persistent Memory Address Range Scrub           < default >    -       Enabled
POST Verbose Boot Progress                      < default >    -       Disabled
Power-On Delay                                  < default >    -       No Delay
Server Asset Tag                                < default >    -
Network Boot Retry Count                        < default >    -       20
```

In the preceding example, each parameter of the configured column has a setting of `< default >`. This means that the value for the configured setting is a null value, as achieved by running the `clear` command for that setting. A BIOS setting configured with `< default > ` as a value does nothing based on that configuration setting when doing BIOS management operations. Thus, for example, the setting for `Boot Mode` in the `Configured` column can only be made to cause a change in the `Pending` or `Live` columns if it takes a value that is not `default`.

**Changing and checking changes for BIOS parameters:** Thus, if the states for a node are as follows for the `Boot Mode` parameter:

**Example**

```bash
[basecm11->device[node002]->biossettings]% status |head -2 ; status |grep "Boot Mode"
Parameter                                       Configured       Pending         Live
----------------------------------------------- ---------------- --------------- ----------------
Boot Mode                                       < default >      -               UEFI Mode
```

then have the `Live` state value change from `UEFI Mode` to `Legacy BIOS Mode`:

1. the first step is to change the `Configured` state:

   **Example**

   ```bash
   [basecm11->device[node002]->biossettings]% set boot mode<tab><tab>
   legacy bios mode  uefi mode
   [basecm11->device[node002]->biossettings]% set boot mode legacy bios mode
   [basecm11->device*[node002]->biossettings*]% commit
   [basecm11->device[node002]->biossettings]% status |head -2 ; status |grep "Boot Mode"
   Parameter                                       Configured       Pending         Live
   ----------------------------------------------- ---------------- --------------- ----------------
   Boot Mode                                       Legacy BIOS Mode -               UEFI Mode
   ```

   * Beside using the `status` command within the `biossettings` submode, the existing BIOS states that are configured (in CMDaemon) and detected (on the live node) can also be checked with the `bios check` command at `node` or `category` level:

     **Example**

     ```bash
     [basecm11->device[node002]->biossettings]% ..
     [basecm11->device[node002]]% bios check
     Result     Parameter                        Configured                       Detected
     ---------- -------------------------------- -------------------------------- ----------
     different  BootMode                         LegacyBios                       Uefi
     ```

     The `bios check` command shows a result if there is a difference between the configured (CMDaemon) and detected (live) configuration.

2. The next step is to apply the configuration change to the `Pending` BIOS state:

   **Example**

   ```bash
   [basecm11->device[node002]]% bios apply
   Node             Result   Output                           Error
   ---------------- -------- -------------------------------- --------------------------------
   node002          good
   [basecm11->device[node002]]% biossettings
   [basecm11->device[node002]->biossettings]% status |head -2 ; status |grep "Boot Mode"
   Parameter                                       Configured       Pending          Live
   ----------------------------------------------- ---------------- ---------------- ---------------
   Boot Mode                                       Legacy BIOS Mode Legacy BIOS Mode UEFI Mode
   ```

3. Finally, a reboot causes the `Pending` value to be made live:

   **Example**

   ```bash
   [basecm11->device[node002]->biossettings]% ..
   [basecm11->device[node002]]% reboot
   [cluster administrator waits for the node to finish rebooting]
   ```

The BIOS change to the `Live` state is then complete. The `Pending` and `Configured` state values are cleared automatically too, so that the states for the `Boot Mode` parameter now show:

**Example**

```bash
[basecm11->device[node002]->biossettings]% status |head -2 ; status |grep "Boot Mode"
Parameter                                       Configured       Pending         Live
----------------------------------------------- ---------------- --------------- ----------------
Boot Mode                                       < default >      -               Legacy BIOS Mode
```

#### 14.5.2.3  BIOS Configuration Via `cm-bios-manage`

This section can usually be skipped because the administrator is not expected to use the `cm-bios-manage` utility directly.

This is because it is relatively low-level, and because the easiest way for a cluster administrator to manage the BIOS of a cluster via Redfish is usually via the `cmsh` ([here](#14522-example-bios-configuration-session-in-cmsh)) or Base View front ends.

The `cm-bios-manage` help text is:

```bash
[root@basecm11 ~]# /cm/local/apps/cm-bios-tools/bin/cm-bios-manage -h
usage: cm-bios-manage [-h]
                      [-a | -c | -f VENDOR_MODEL | -p VENDOR_MODEL | -P VENDOR_MODEL PROFILE | -t |
-T VENDOR_MODEL] [-l] [-d]

Script used by cmd to manage BIOS settings.

optional arguments:
  -h, --help            show this help message and exit
  -a, --apply           apply settings.
  -c, --check           check defined settings.
  -f VENDOR_MODEL, --fetch VENDOR_MODEL
                        fetch settings based on JSON template of specified model.
  -p VENDOR_MODEL, --profiles VENDOR_MODEL
                        list all profiles for the specified model.
  -P VENDOR_MODEL PROFILE, --profile VENDOR_MODEL PROFILE
                        display profile for the specified model and specified profile.
  -t, -m, --vendor-types, --models
                    list all supported HW models.
  -T VENDOR_MODEL, --template VENDOR_MODEL
                        display JSON template of specified HW model.
  -l, --live            fetch live settings, instead of pending settings.
                        used with --fetch and --check options.
  -d, --debug           enable debug messages.
```

A session with options might run as follows:

**Example**

```bash
[root@basecm11 ~]# /cm/local/apps/cm-bios-tools/python/cm-bios-manage -t
[
  "dell_r730",
  "hpe_dl380"
]
[root@basecm11 ~]# /cm/local/apps/cm-bios-tools/python/cm-bios-manage -p hpe_dl380
[
  "test"
]
[root@basecm11 ~]# /cm/local/apps/cm-bios-tools/python/cm-bios-manage -P hpe_dl380 test
{
  "test": "xyz"
}
[root@basecm11 ~]# /cm/local/apps/cm-bios-tools/python/cm-bios-manage -T hpe_dl380
[{
    "displayName": "High Precision Event Timer (HPET) ACPI Support",
    "name": "AcpiHpet",
    "pos": {
      "w": 12,
      "r": 0,
      "o": 0,
      "g": 0
    },
...
```

### 14.5.3  Updating BIOS And Firmware Versions

There are two ways that the firmware can be updated. A legacy way based on DOS tools ([here](#14531-updating-a-bios-via-dos-tools)), and a more recent way, based on CMDaemon and Redfish ([here](#14532-firmware-configuration-and-updates-via-cmdaemon)).

#### 14.5.3.1  Updating A BIOS Via DOS Tools

The legacy way of upgrading a BIOS to a new version involves using the DOS tools that were supplied with the BIOS to flash a new BIOS. The flash tool and the BIOS image must be copied to a DOS image. The file `autoexec.bat` should be altered to invoke the flash utility with the correct parameters. In case of doubt, it can be useful to boot the DOS image and invoke the BIOS flash tool manually. Once the correct parameters have been determined, they can be added to the `autoexec.bat`.

After a BIOS upgrade, the contents of the NVRAM may no longer represent a valid BIOS configuration because different BIOS versions may store a configuration in different formats. It is therefore recommended to also write updated NVRAM settings immediately after flashing a BIOS image.

The next section describes how to boot the DOS image.

**Booting the DOS image:**  To boot the DOS image over the network, it first needs to be copied to software image’s `/boot` directory, and must be world-readable.

**Example**

```bash
cp flash.img /cm/images/default-image/boot/bios/flash.img
chmod 644 /cm/images/default-image/boot/bios/flash.img
```

An entry is added to the PXE boot menu to allow the DOS image to be selected. This can easily be achieved by modifying the contents of `/cm/images/default-image/boot/bios/menu.conf`, which is by default included automatically in the PXE menu. By default, one entry `Example` is included in the PXE menu, which is however invisible as a result of the `MENU HIDE` option. Removing the `MENU HIDE` line will make the BIOS flash option selectable. Optionally the `LABEL` and `MENU LABEL` may be set to an appropriate description.

The option `MENU DEFAULT` may be added to make the BIOS flash image the default boot option. This is convenient when flashing the BIOS of many nodes.

**Example**

```bash
  LABEL FLASHBIOS
    KERNEL memdisk
    APPEND initrd=bios/flash.img
    MENU LABEL ^Flash BIOS
  #  MENU HIDE
    MENU DEFAULT
```

The `bios/menu.conf` file may contain multiple entries corresponding to several DOS images to allow for flashing of multiple BIOS versions or configurations.

#### 14.5.3.2  Firmware Configuration And Updates Via CMDaemon

For systems that support the Redfish protocol, such as HPE iLO and DGX H100, firmware management requires setting `firmwaremanagemode`, within a `bmcsettings` submode. HPE systems including DL380a Gen 12 are supported identically to earlier HPE generations under this same Redfish-based firmware management, with no separate procedure required.

In addition, for DGX hardware, after the firmware has been flashed over to it, an activation based on an AC power cycle is required. Details on this are given ([here](#ac-and-dc-power-cycling-for-the-dgx-h100)) as part of the DGX installation example later on ([here](#a-gpu-tray-upgrade-example-on-the-dgx-h100)).

**Setting `firmwaremanagemode`:** The value of `firmwaremanagemode` is selected appropriately by the administrator according to the node hardware:

**Example**

```bash
[basecm11->device*[node001*]->bmcsettings*]% set firmwaremanagemode <TAB><TAB>
auto     b200     b300     gb200    gb200sw  gb300    gb300sw  h100     iLO      none
```

The `bmcsettings` submode can be accessed and set within an instance of the `device`, `category`, or `partition` modes.

**Running `firmware` operations and options:** After `firmwaremanagemode` has been set, the `firmware` command can be run under the `device` mode of `cmsh` to carry out Redfish protocol updates. Firmware updated via Redfish need not be just the PC main system BIOS, but can also be the flashable software of subsystems, for example: NICs.

The `help firmware` command provides a help page covering the operations and options for the `firmware` command. Some of them are described next:

* The `firmware` command includes the following operations:

  * `info`: provides information on the firmwares available on the head node, available for uploading to nodes. By default these are files that the cluster administrator has picked up from the vendor and has placed under `/cm/local/apps/cmd/etc/htdocs/bios/firmware/`.

  * `list`: (only for iLO) provides a list of firmware states on specified nodes.

  * `upload`: (only for iLO) takes a specified firmware from the files listed by the `info` option, and copies it over to the specified nodes. For an HPE iLO system, the upload is carried out to a special flash storage, only visible to the BIOS and Redfish queries. After it is in that special flash location, it can be flashed to where the firmware is actually run.

  * `remove`: (only for iLO) removes a specified firmware from the special flash storage of specified nodes

  * `flash` : carries out the flashing of the firmware from the flash storage to the location where the firmware runs, for the specified nodes

  * `status`: shows the status of the flash operation. A table is displayed with rows listing the component, version, and state, among other items. The `State` column of the output can show the following values:

    * `pending`: the flash operation is pending

    * `exception`: the flash operation failed during execution

    * `flashing`: the flash operation is being executed

    * `completed`: the flash operation succeeded

    * `current`: the firmware of the listed component with the listed version is activated

* The `firmware` command also includes the following options:

  * `--targets`: (only for DGX hosts) specifies names for particular component firmware targets. Without this option, the default is that updates are carried out automatically only for newer firmware components from the firmware package files. Overriding the default should not be needed, and is typically not recommended. Specifying `--targets list -v` lists the possible components.

  * `--force`: (only for DGX hosts) needed to carry out a downgrade, and also needed for some other DGX firmware cases as described in [https://docs.nvidia.com/dgx/dgxh100-fw-update-guide/sequence.html#update-steps](https://docs.nvidia.com/dgx/dgxh100-fw-update-guide/sequence.html#update-steps)

  * `--dry-run`: (only for DGX hosts) pretends to carry out an installation, so that the administrator can get an idea of what components are affected from the output of the mock installation run

**An HP iLO5 firmware upgrade example:** The following session shows `node001` getting uploaded and flashed with a firmware, and then having the firmware removed.

**Example**

```bash
[basecm11->device]% firmware info
Device   Filename     Component        Version  State      Progress Result   Size     Date
-------- ------------ ---------------- -------- ---------- -------- -------- -------- ---------------------
basecm11 iLO5-2.42    iLO5             2.42     undefined  N/A               8.6MiB   02/28/2022, 11:22:55
basecm11 iLO5-2.43    iLO5             2.43     undefined  N/A               8.7MiB   02/28/2022, 11:22:55
basecm11 iLO5-2.44    iLO5             2.44     undefined  N/A               8.8MiB   02/28/2022, 11:22:55
basecm11 iLO5-2.45    iLO5             2.45     undefined  N/A               8.9MiB   02/28/2022, 11:22:55

[basecm11->device]% firmware list -n node001

[basecm11->device]% firmware upload iLO5-2.42 -n node001
Device   Result   Output                 Error
-------- -------- ---------------------- --------------------------------
node001  good     uploading: iLO5-2.42

[basecm11->device]% firmware list -n node001
Device   Filename     Component        Version  State      Progress Result   Size     Date
-------- ------------ ---------------- -------- ---------- -------- -------- -------- ---------------------
node001  iLO5-2.42    iLO5             2.42     completed  N/A               8.6MiB   02/28/2022, 11:23:31

[basecm11->device]% firmware flash iLO5-2.42 -n node001
Device   Result   Output                 Error
-------- -------- ---------------------- --------------------------------
node001  good     flashing: iLO5-2.42

[basecm11->device]% firmware status -n node001
Device   Filename     Component        Version  State     Progress Result   Size     Date
-------- ------------ ---------------- -------- --------- -------- -------- -------- ---------------------
node001               iLO5             2.42     flashing  35.6%             N/A      02/28/2022, 11:27:27

[basecm11->device]% firmware status -n node001
Device   Filename     Component        Version  State      Progress Result   Size     Date
-------- ------------ ---------------- -------- ---------- -------- -------- -------- ---------------------
node001               iLO5             2.42     completed  N/A               N/A      02/28/2022, 11:27:27

[basecm11->device]% firmware remove iLO5-2.42 -n node001
Device   Result   Output                 Error
-------- -------- ---------------------- --------------------------------
node001  good     removed: iLO5-2.42

[basecm11->device]% firmware list -n node001

```

**A GPU tray upgrade example on the DGX H100:**  The procedure to upgrade DGX firmware varies slightly across the different hardwares (H100, B200, GB200 ...). For the DGX H100 the upgrade procedure is as follows:

###### Obtaining and placing the firmware packages on the DGX H100 cluster:

Firmware for the DGX H100 is available for the motherboard tray (chassis) components, and for the GPU tray components.

Firmware packages for the DGX H100 can be obtained via the DGX support portal, which can be reached from:

[https://docs.nvidia.com/dgx/dgxh100-fw-update-guide/about.html#firmware-update-prerequisites](https://docs.nvidia.com/dgx/dgxh100-fw-update-guide/about.html#firmware-update-prerequisites).

The packages are available as `.fwpkg` packages. They should be placed in the head node directory at

`/cm/local/apps/cmd/etc/htdocs/bios/firmware/`

under the appropriate existing subdirectory for the platform type:

**Example**

```bash
[basecm11 ~]# ls -l /cm/local/apps/cmd/etc/htdocs/bios/firmware/h100
-rw-r--r-- 1 root root 135723563 Dec 12 14:27 nvfw_DGX-H100_0003_230817.1.1_custom_prod-signed.fwpkg
-rw-r--r-- 1 root root 135723563 Dec 12 14:27 nvfw_DGX-H100_0003_230905.1.0_custom_prod-signed.fwpkg
-rw-r--r-- 1 root root 135723563 Dec 12 14:27 nvfw_DGX-H100_0003_230920.1.0_custom_prod-signed.fwpkg
-rw-r--r-- 1 root root 106091440 Dec 12 14:27 nvfw_DGX-HGX-H100x8_0002_230705.1.1_prod-signed.fwpkg
```

###### Configuring BMC settings in BCM for the DGX H100:

The BMC interface and settings should be configured for the DGX H100. Typically this requires:

* adding a BMC network (section [3.2.2](/admin/configuring#322-adding-networks))

* configuring its BMC settings (section [3.7.2](/admin/configuring#372-bmc-authentication)) to be able to carry out the Redfish protocol. This means setting the:

  * username

  * userid

  * password

  * firmware mode for Redfish

* adding an interface to the network for the node (section [3.7.1](/admin/configuring#371-bmc-network-settings)).

**Example**

```bash
[basecm11 ~]# cmsh
[basecm11]% network
[basecm11->network]% add bmcnet
[basecm11->network*[bmcnet*]]% set baseaddress 10.148.0.0
[basecm11->network*[bmcnet*]]% set domainname bmc.cluster
[basecm11->network*[bmcnet*]]% commit
[basecm11->network[bmcnet]]% partition
[basecm11->partition[base]]% bmcsettings
[basecm11->partition[base]->bmcsettings]% set username admin
[basecm11->partition*[base*]->bmcsettings*]% set userid 0
[basecm11->partition*[base*]->bmcsettings*]% set password < password>
[basecm11->partition*[base*]->bmcsettings*]% set firmwaremanagemode <TAB><TAB>
auto     b200     b300     gb200    gb200sw  gb300    gb300sw  h100     iLO      none
[basecm11->partition*[base*]->bmcsettings*]% set firmwaremanagemode h100
[basecm11->partition*[base*]->bmcsettings*]% commit
[basecm11->partition[base]->bmcsettings]% device
[basecm11->device]% interfaces node001
[basecm11->device[node001]->interfaces]% add bmc
[basecm11->device[node001]->interfaces]% add bmc ipmi0
[basecm11->device*[node001*]->interfaces*[ipmi0*]]% set network bmcnet
[basecm11->device*[node001*]->interfaces*[ipmi0*]]% set ip 10.148.0.1
```

###### Managing, installing and updating the firmware package in BCM for the DGX H100:

BCM can then display information about the files in that head node firmware directory with the `firmware info` command:

**Example**

```bash
[basecm11->device]% firmware info
Device   Filename                      Component         Version             State      Progress  ...
-------- ----------------------------  ----------------- ------------------- ---------- --------
basecm11 nvfw_DGX-H100_...fwpkg        DGX-H100-Chassis  DGX-H100_0003_2...  available  N/A
basecm11 nvfw_DGX-H100_...fwpkg        DGX-H100-Chassis  DGX-H100_0003_2...  available  N/A
basecm11 nvfw_DGX-HGX-H100x8_...fwpkg  DGX-H100-GPU      DGX-HGX-H100x8_...  available  N/A
```

The `firmware status` command displays information on the state of the firmware components running on the node:

**Example**

```bash
[basecm11->device]% firmware status -n node001
Device  Filename Component                 Version              State   Progress  Result Size Date
------- -------- ------------------------- -------------------- ------- --------- ------ ---- ----
node001          CPLDMB_0                  0.2.1.0              current  N/A             N/A
node001          CPLDMID_0                 0.2.1.0              current  N/A             N/A
node001          EROT_BIOS_0               00.04.0020.0000_n00  current  N/A             N/A
node001          EROT_BMC_0                00.04.0020.0000_n00  current  N/A             N/A
node001          HGX_FW_BMC_0              HGX-22.10-1-rc1      current  N/A             N/A
node001          HGX_FW_ERoT_BMC_0         00.02.0100.0000_n00  current  N/A             N/A
node001          HGX_FW_ERoT_FPGA_0        00.02.0100.0000_n00  current  N/A             N/A
node001          HGX_FW_ERoT_NVSwitch_0    00.02.0100.0000_n00  current  N/A             N/A
node001          HGX_FW_ERoT_NVSwitch_1    00.02.0100.0000_n00  current  N/A             N/A
node001          HGX_FW_ERoT_NVSwitch_2    00.02.0100.0000_n00  current  N/A             N/A
node001          HGX_FW_ERoT_NVSwitch_3    00.02.0100.0000_n00  current  N/A             N/A
node001          HGX_FW_ERoT_PCIeSwitch_0  00.02.0100.0000_n00  current  N/A             N/A
node001          HGX_FW_FPGA_0             2.0A                 current  N/A             N/A
node001          HGX_FW_GPU_SXM_1          96.00.70.00.01       current  N/A             N/A
node001          HGX_FW_GPU_SXM_2          96.00.70.00.01       current  N/A             N/A
node001          HGX_FW_GPU_SXM_3          96.00.70.00.01       current  N/A             N/A
node001          HGX_FW_GPU_SXM_4          96.00.70.00.01       current  N/A             N/A
node001          HGX_FW_GPU_SXM_5          96.00.70.00.01       current  N/A             N/A
node001          HGX_FW_GPU_SXM_6          96.00.70.00.01       current  N/A             N/A
node001          HGX_FW_GPU_SXM_7          96.00.70.00.01       current  N/A             N/A
node001          HGX_FW_GPU_SXM_8          96.00.70.00.01       current  N/A             N/A
node001          HGX_FW_NVSwitch_0         96.00.3F.00.01       current  N/A             N/A
node001          HGX_FW_NVSwitch_1         96.00.3F.00.01       current  N/A             N/A
node001          HGX_FW_NVSwitch_2         96.00.3F.00.01       current  N/A             N/A
node001          HGX_FW_NVSwitch_3         96.00.3F.00.01       current  N/A             N/A
node001          HGX_FW_PCIeRetimer_0      2.7.0                current  N/A             N/A
node001          HGX_FW_PCIeRetimer_1      2.7.0                current  N/A             N/A
node001          HGX_FW_PCIeRetimer_2      2.7.0                current  N/A             N/A
node001          HGX_FW_PCIeRetimer_3      2.7.0                current  N/A             N/A
node001          HGX_FW_PCIeRetimer_4      2.7.0                current  N/A             N/A
node001          HGX_FW_PCIeRetimer_5      2.7.0                current  N/A             N/A
node001          HGX_FW_PCIeRetimer_6      2.7.0                current  N/A             N/A
node001          HGX_FW_PCIeRetimer_7      2.7.0                current  N/A             N/A
node001          HGX_FW_PCIeSwitch_0       1.7.5A               current  N/A             N/A
node001          HostBIOS_0                01.00.00             current  N/A             N/A
node001          HostBMC_0                 23.00.00             current  N/A             N/A
node001          PCIeRetimer_0             1.30.0               current  N/A             N/A
node001          PCIeRetimer_1             1.30.0               current  N/A             N/A
node001          PCIeSwitch_0              0.0.1                current  N/A             N/A
node001          PCIeSwitch_1              1.0.1                current  N/A             N/A
node001          PSU_0                     0202.0200.0200       current  N/A             N/A
node001          PSU_1                     0202.0200.0200       current  N/A             N/A
node001          PSU_2                     0202.0200.0200       current  N/A             N/A
node001          PSU_3                     0202.0201.0202       current  N/A             N/A
node001          PSU_4                     0202.0201.0203       current  N/A             N/A
node001          PSU_5                     0202.0200.0200       current  N/A             N/A
```

Components can be updated by installing associated firmware packages with the `firmware flash` command. For example, the GPU tray firmware can be installed with one of the `nvfw_dgx-hgx-h100x8*` packages:

**Example**

```bash
[basecm11->device[node001]]% firmware flash <TAB><TAB>
nvfw_dgx-h100_0003_230817.1.1.fwpkg
nvfw_dgx-h100_0003_230920.1.0.fwpkg
nvfw_dgx-hgx-h100x8_0002_230705.1.1.fwpkg
[basecm11->device[node001]]% firmware flash nvfw_dgx-hgx-h100x8_0002_230705.1.1.fwpkg
Device           flashing                                   Result   Error
---------------- ------------------------------------------ -------- ----------
node001          nvfw_DGX-HGX-H100x8_0002_230705.1.1.fwpkg  good
```

The `firmware status` command then shows the installation progress for the GPU tray components during flashing:

**Example**

```bash
[basecm11->device]% firmware -n node001 status
Device  Filename             Component                 Version              State     Progress...
------- -------------------- ------------------------- -------------------- --------- --------
node001                      CPLDMB_0                  0.2.1.0              current   N/A
node001                      CPLDMID_0                 0.2.1.0              current   N/A
node001                      EROT_BIOS_0               00.04.0020.0000_n00  current   N/A
node001                      EROT_BMC_0                00.04.0020.0000_n00  current   N/A
node001                      HostBIOS_0                01.00.00             current   N/A
node001                      HostBMC_0                 23.00.00             current   N/A
node001                      PCIeRetimer_0             1.30.0               current   N/A
node001                      PCIeRetimer_1             1.30.0               current   N/A
node001                      PCIeSwitch_0              0.0.1                current   N/A
node001                      PCIeSwitch_1              1.0.1                current   N/A
node001                      PSU_0                     0202.0200.0200       current   N/A
node001                      PSU_1                     0202.0200.0200       current   N/A
node001                      PSU_2                     0202.0200.0200       current   N/A
node001                      PSU_3                     0202.0201.0202       current   N/A
node001                      PSU_4                     0202.0201.0203       current   N/A
node001                      PSU_5                     0202.0200.0200       current   N/A
node001 nvfw_DGX-HG...fwpkg  HGX_FW_BMC_0              HGX-22.10-1-rc1      flashing  39.1%
node001 nvfw_DGX-HG...fwpkg  HGX_FW_ERoT_BMC_0         00.02.0100.0000_n00  flashing  39.1%
node001 nvfw_DGX-HG...fwpkg  HGX_FW_ERoT_FPGA_0        00.02.0100.0000_n00  flashing  39.1%
node001 nvfw_DGX-HG...fwpkg  HGX_FW_ERoT_NVSwitch_0    00.02.0100.0000_n00  flashing  39.1%
node001 nvfw_DGX-HG...fwpkg  HGX_FW_ERoT_NVSwitch_1    00.02.0100.0000_n00  flashing  39.1%
node001 nvfw_DGX-HG...fwpkg  HGX_FW_ERoT_NVSwitch_2    00.02.0100.0000_n00  flashing  39.1%
node001 nvfw_DGX-HG...fwpkg  HGX_FW_ERoT_NVSwitch_3    00.02.0100.0000_n00  flashing  39.1%
node001 nvfw_DGX-HG...fwpkg  HGX_FW_ERoT_PCIeSwitch_0  00.02.0100.0000_n00  flashing  39.1%
node001 nvfw_DGX-HG...fwpkg  HGX_FW_FPGA_0             2.0A                 flashing  39.1%
node001 nvfw_DGX-HG...fwpkg  HGX_FW_GPU_SXM_1          96.00.70.00.01       flashing  39.1%
node001 nvfw_DGX-HG...fwpkg  HGX_FW_GPU_SXM_2          96.00.70.00.01       flashing  39.1%
node001 nvfw_DGX-HG...fwpkg  HGX_FW_GPU_SXM_3          96.00.70.00.01       flashing  39.1%
node001 nvfw_DGX-HG...fwpkg  HGX_FW_GPU_SXM_4          96.00.70.00.01       flashing  39.1%
node001 nvfw_DGX-HG...fwpkg  HGX_FW_GPU_SXM_5          96.00.70.00.01       flashing  39.1%
node001 nvfw_DGX-HG...fwpkg  HGX_FW_GPU_SXM_6          96.00.70.00.01       flashing  39.1%
node001 nvfw_DGX-HG...fwpkg  HGX_FW_GPU_SXM_7          96.00.70.00.01       flashing  39.1%
node001 nvfw_DGX-HG...fwpkg  HGX_FW_GPU_SXM_8          96.00.70.00.01       flashing  39.1%
node001 nvfw_DGX-HG...fwpkg  HGX_FW_NVSwitch_0         96.00.3F.00.01       flashing  39.1%
node001 nvfw_DGX-HG...fwpkg  HGX_FW_NVSwitch_1         96.00.3F.00.01       flashing  39.1%
node001 nvfw_DGX-HG...fwpkg  HGX_FW_NVSwitch_2         96.00.3F.00.01       flashing  39.1%
node001 nvfw_DGX-HG...fwpkg  HGX_FW_NVSwitch_3         96.00.3F.00.01       flashing  39.1%
node001 nvfw_DGX-HG...fwpkg  HGX_FW_PCIeRetimer_0      2.7.0                flashing  39.1%
node001 nvfw_DGX-HG...fwpkg  HGX_FW_PCIeRetimer_1      2.7.0                flashing  39.1%
node001 nvfw_DGX-HG...fwpkg  HGX_FW_PCIeRetimer_2      2.7.0                flashing  39.1%
node001 nvfw_DGX-HG...fwpkg  HGX_FW_PCIeRetimer_3      2.7.0                flashing  39.1%
node001 nvfw_DGX-HG...fwpkg  HGX_FW_PCIeRetimer_4      2.7.0                flashing  39.1%
node001 nvfw_DGX-HG...fwpkg  HGX_FW_PCIeRetimer_5      2.7.0                flashing  39.1%
node001 nvfw_DGX-HG...fwpkg  HGX_FW_PCIeRetimer_6      2.7.0                flashing  39.1%
node001 nvfw_DGX-HG...fwpkg  HGX_FW_PCIeRetimer_7      2.7.0                flashing  39.1%
node001 nvfw_DGX-HG...fwpkg  HGX_FW_PCIeSwitch_0       1.7.5A               flashing  39.1%
```

The non-GPU-related firmware components are not updated.

If the `firmware flash` command stage has completed its run, then when the `firmware status` command is run, the `Component` and `Version` columns show output indicating that the firmware version is transitioning. The rows that have to do with the GPU firmware status are the rows with the string `nvfw_DGX-HG` in the `Filename` column. Those GPU firmware rows have `Component` and `Version` column entries such as:

**Example**

```bash
[basecm11->device[node001]]% firmware status| head -2| cut -b66-133; firmware status| grep nvfw| cut -b66-133
Component                 Version
------------------------- ------------------------------------------
HGX_FW_BMC_0              HGX-22.10-1-rc1 -> HGX-22.10-1-rc44
HGX_FW_ERoT_BMC_0         00.02.0100.0000_n00 -> 00.02.0134.0000_n00
HGX_FW_ERoT_FPGA_0        00.02.0100.0000_n00 -> 00.02.0134.0000_n00
HGX_FW_ERoT_NVSwitch_0    00.02.0100.0000_n00 -> 00.02.0134.0000_n00
HGX_FW_ERoT_NVSwitch_1    00.02.0100.0000_n00 -> 00.02.0134.0000_n00
HGX_FW_ERoT_NVSwitch_2    00.02.0100.0000_n00 -> 00.02.0134.0000_n00
HGX_FW_ERoT_NVSwitch_3    00.02.0100.0000_n00 -> 00.02.0134.0000_n00
HGX_FW_ERoT_PCIeSwitch_0  00.02.0100.0000_n00 -> 00.02.0134.0000_n00
HGX_FW_FPGA_0             2.0A -> 2.2C
HGX_FW_GPU_SXM_1          96.00.70.00.01 -> 96.00.74.00.01
HGX_FW_GPU_SXM_2          96.00.70.00.01 -> 96.00.74.00.01
HGX_FW_GPU_SXM_3          96.00.70.00.01 -> 96.00.74.00.01
HGX_FW_GPU_SXM_4          96.00.70.00.01 -> 96.00.74.00.01
HGX_FW_GPU_SXM_5          96.00.70.00.01 -> 96.00.74.00.01
HGX_FW_GPU_SXM_6          96.00.70.00.01 -> 96.00.74.00.01
HGX_FW_GPU_SXM_7          96.00.70.00.01 -> 96.00.74.00.01
HGX_FW_GPU_SXM_8          96.00.70.00.01 -> 96.00.74.00.01
HGX_FW_NVSwitch_0         96.00.3F.00.01 -> 96.10.3F.00.01
HGX_FW_NVSwitch_1         96.00.3F.00.01 -> 96.10.3F.00.01
HGX_FW_NVSwitch_2         96.00.3F.00.01 -> 96.10.3F.00.01
HGX_FW_NVSwitch_3         96.00.3F.00.01 -> 96.10.3F.00.01
HGX_FW_PCIeRetimer_0      2.7.0 -> 2.7.9
HGX_FW_PCIeRetimer_1      2.7.0 -> 2.7.9
HGX_FW_PCIeRetimer_2      2.7.0 -> 2.7.9
HGX_FW_PCIeRetimer_3      2.7.0 -> 2.7.9
HGX_FW_PCIeRetimer_4      2.7.0 -> 2.7.9
HGX_FW_PCIeRetimer_5      2.7.0 -> 2.7.9
HGX_FW_PCIeRetimer_6      2.7.0 -> 2.7.9
HGX_FW_PCIeRetimer_7      2.7.0 -> 2.7.9
HGX_FW_PCIeSwitch_0       1.7.5A -> 1.7.5F
```

In the preceding, the `grep` command is to select just the GPU-related rows, and the `cut` commands are used to remove some columns, to make the output clearer to the reader.

The `firmware status` GPU firmware rows also have the following output columns:

* the `State` column, which shows `Pending` if there are activation steps still required to complete the firmware update

* the `Result` column, which suggests the recommended action to take to activate the firmware

**Example**

```bash
[basecm11->device[node001]]% firmware status   #other rows and columns omitted for readability
State    Progress Result                               Size     Date
-------- -------- ------------------------------------ -------- --------
pending  N/A      success: AC power cycle to activate  1.22KiB
pending  N/A      success: AC power cycle to activate  1.22KiB
pending  N/A      success: AC power cycle to activate  1.22KiB
...
```

###### AC and DC power cycling for the DGX H100:

As suggested in the `Result` column in the preceding example, an `AC power cycle` must then be carried out on the node to activate the GPU firmware with the new versions. The `AC power cycle` tag is a part of Redfish terminology, and it implies that all the AC power inputs need to be cut off. This can be carried out via a PDU powering off the entire system, or it can be done physically, by hand, by pulling out all the mains (AC) power leads to the system.

A regular `power reset` command run from the `device` mode of `cmsh`, which is a board level (DC) power cycle by default, is not enough to initialize some of the components for the DGX H100.

Details on firmware activation for the DGX H100 can be found at [https://docs.nvidia.com/dgx/dgxh100-fw-update-guide/about.html#firmware-update-activation](https://docs.nvidia.com/dgx/dgxh100-fw-update-guide/about.html#firmware-update-activation).

###### Successful activation and completed state confirmations for the DGX H100:

After the power cycle, the output from `firmware status` indicates that the firmware now active on the node matches that of the `.fwpkg` file version.

It does this by displaying a value of

`success: activated`

in the `Result` column.

The output also now shows the new version value for the firmware component in the `Version` column, and indicates the firmware transition is now over with a value of `completed` in the `State` column:

```bash
[basecm11->device]% firmware -n node001 status
Device   Filename       Component                 Version               State      Progress Result
-------- -------------- ------------------------- -------------------------------- -------- -------------------
node001                 CPLDMB_0                  0.2.1.0               current    N/A
node001                 CPLDMID_0                 0.2.1.0               current    N/A
node001                 EROT_BIOS_0               00.04.0020.0000_n00   current    N/A
node001                 EROT_BMC_0                00.04.0020.0000_n00   current    N/A
node001                 HostBIOS_0                01.00.00              current    N/A
node001                 HostBMC_0                 23.00.00              current    N/A
node001                 PCIeRetimer_0             1.30.0                current    N/A
node001                 PCIeRetimer_1             1.30.0                current    N/A
node001                 PCIeSwitch_0              0.0.1                 current    N/A
node001                 PCIeSwitch_1              1.0.1                 current    N/A
node001                 PSU_0                     0202.0200.0200        current    N/A
node001                 PSU_1                     0202.0200.0200        current    N/A
node001                 PSU_2                     0202.0200.0200        current    N/A
node001                 PSU_3                     0202.0201.0202        current    N/A
node001                 PSU_4                     0202.0201.0203        current    N/A
node001                 PSU_5                     0202.0200.0200        current    N/A
node001  nvfw_...fwpkg  HGX_FW_BMC_0              HGX-22.10-1-rc44      completed  N/A      success: activated
node001  nvfw_...fwpkg  HGX_FW_ERoT_BMC_0         00.02.0134.0000_n00   completed  N/A      success: activated
node001  nvfw_...fwpkg  HGX_FW_ERoT_FPGA_0        00.02.0134.0000_n00   completed  N/A      success: activated
node001  nvfw_...fwpkg  HGX_FW_ERoT_NVSwitch_0    00.02.0134.0000_n00   completed  N/A      success: activated
node001  nvfw_...fwpkg  HGX_FW_ERoT_NVSwitch_1    00.02.0134.0000_n00   completed  N/A      success: activated
node001  nvfw_...fwpkg  HGX_FW_ERoT_NVSwitch_2    00.02.0134.0000_n00   completed  N/A      success: activated
node001  nvfw_...fwpkg  HGX_FW_ERoT_NVSwitch_3    00.02.0134.0000_n00   completed  N/A      success: activated
node001  nvfw_...fwpkg  HGX_FW_ERoT_PCIeSwitch_0  00.02.0134.0000_n00   completed  N/A      success: activated
node001  nvfw_...fwpkg  HGX_FW_FPGA_0             2.2C                  completed  N/A      success: activated
node001  nvfw_...fwpkg  HGX_FW_GPU_SXM_1          96.00.74.00.01        completed  N/A      success: activated
node001  nvfw_...fwpkg  HGX_FW_GPU_SXM_2          96.00.74.00.01        completed  N/A      success: activated
node001  nvfw_...fwpkg  HGX_FW_GPU_SXM_3          96.00.74.00.01        completed  N/A      success: activated
node001  nvfw_...fwpkg  HGX_FW_GPU_SXM_4          96.00.74.00.01        completed  N/A      success: activated
node001  nvfw_...fwpkg  HGX_FW_GPU_SXM_5          96.00.74.00.01        completed  N/A      success: activated
node001  nvfw_...fwpkg  HGX_FW_GPU_SXM_6          96.00.74.00.01        completed  N/A      success: activated
node001  nvfw_...fwpkg  HGX_FW_GPU_SXM_7          96.00.74.00.01        completed  N/A      success: activated
node001  nvfw_...fwpkg  HGX_FW_GPU_SXM_8          96.00.74.00.01        completed  N/A      success: activated
node001  nvfw_...fwpkg  HGX_FW_NVSwitch_0         96.10.3F.00.01        completed  N/A      success: activated
node001  nvfw_...fwpkg  HGX_FW_NVSwitch_1         96.10.3F.00.01        completed  N/A      success: activated
node001  nvfw_...fwpkg  HGX_FW_NVSwitch_2         96.10.3F.00.01        completed  N/A      success: activated
node001  nvfw_...fwpkg  HGX_FW_NVSwitch_3         96.10.3F.00.01        completed  N/A      success: activated
node001  nvfw_...fwpkg  HGX_FW_PCIeRetimer_0      2.7.9                 completed  N/A      success: activated
node001  nvfw_...fwpkg  HGX_FW_PCIeRetimer_1      2.7.9                 completed  N/A      success: activated
node001  nvfw_...fwpkg  HGX_FW_PCIeRetimer_2      2.7.9                 completed  N/A      success: activated
node001  nvfw_...fwpkg  HGX_FW_PCIeRetimer_3      2.7.9                 completed  N/A      success: activated
node001  nvfw_...fwpkg  HGX_FW_PCIeRetimer_4      2.7.9                 completed  N/A      success: activated
node001  nvfw_...fwpkg  HGX_FW_PCIeRetimer_5      2.7.9                 completed  N/A      success: activated
node001  nvfw_...fwpkg  HGX_FW_PCIeRetimer_6      2.7.9                 completed  N/A      success: activated
node001  nvfw_...fwpkg  HGX_FW_PCIeRetimer_7      2.7.9                 completed  N/A      success: activated
node001  nvfw_...fwpkg  HGX_FW_PCIeSwitch_0       1.7.5F                completed  N/A      success: activated
```

**A DGX GB200 and GB300 firmware update:**  Procedures to upgrade DGX firmware components on the DGX GB200 and DGX GB300 hardware can be carried out after the hardware components (the compute trays, NVLink switch trays, and power shelves) are seen as being up in BCM. The procedure generally follows the firmware upgrade outlined for DGX H100 hardware ([here](#a-gpu-tray-upgrade-example-on-the-dgx-h100)). More details specific to the GB200 and GB300 hardware can be found at:

[https://docs.nvidia.com/mission-control/docs/rack-bring-up-install/2.0.0/rack-firmware-update.html#](https://docs.nvidia.com/mission-control/docs/rack-bring-up-install/2.0.0/rack-firmware-update.html#).

The `cm-nvfwupd` module is used by `cmsh` in `firmware` command operations. BCM point release version 11.34.0 introduces module version 2.1.2, which adds support for the GB200 NVL72 rack and Rubin-generation platforms.

**Setting `firmwaremanagemode` for the DGX GB200 and GB300:** The `gb200` and `gb300` values ([here](#gb200-rack-firmware-updates)) apply to the compute tray, while `gb200sw` and `gb300sw` apply to the NVLink switch tray in the NVL72 rack.

###### Obtaining and placing the firmware packages for the DGX GB200 and GB300:

Firmware for the compute tray is available as two `.fwpkg` packages: one for the DGX-side components (BMC, EROT, CPLD) and one for the HGX-side components (BMC, CPU, GPU, EROT, FPGA, CPLD). Firmware for the NVLink switch tray is available as three `.fwpkg` packages, covering BMC/EROT/FPGA, SBIOS/EROT, and CPLD respectively.

The packages should be placed in the head node directory at

`/cm/local/apps/cmd/etc/htdocs/bios/firmware/`

under the `gb200` subdirectory for compute-tray packages, and the `gb200sw` subdirectory for switch-tray packages (the same two subdirectories are also used for GB300, since GB300 uses the same package-naming and directory scheme):

**Example**

```bash
[basecm11 ~]# ls -l /cm/local/apps/cmd/etc/htdocs/bios/firmware/gb200
-rw-r--r-- 1 root root  67349914 Nov 10 11:26 nvfw_DGX-GBX00_0023_250901.1.0_custom_prod-signed.fwpkg
-rw-r--r-- 1 root root 119706314 Nov 10 11:26 nvfw_HGX-GBX00_0023_250908.1.0_custom_prod-signed.fwpkg
[basecm11 ~]# ls -l /cm/local/apps/cmd/etc/htdocs/bios/firmware/gb200sw
-rw-r--r-- 1 root root  78998965 Nov 10 11:27 nvfw_GB200-P4978_0004_250821.1.0_prod-signed.fwpkg
-rw-r--r-- 1 root root  17018227 Nov 10 11:27 nvfw_GB200-P4978_0006_250710.1.1_prod-signed.fwpkg
-rw-r--r-- 1 root root   1729367 Nov 10 11:27 nvfw_GB200-P4978_0007_250831.1.0_prod-signed.fwpkg
```

###### Configuring access for the NVLink switch tray:

In addition to setting `firmwaremanagemode` to `gb200sw` (or `gb300sw`), the NVLink switch tray needs a further access-settings configuration step, since its firmware commands are carried out via the NVOS REST API rather than the Redfish protocol used by the compute tray. This is configured in the `accesssettings` submode (the same submode used to configure switch access elsewhere in this manual, section [3.9.1.1](/admin/configuring#3911-cumulus-switches-access-configuration)), by setting a username and password:

**Example**

```bash
[basecm11->device[switch001]]% accesssettings
[basecm11->device[switch001]->accesssettings]% set username admin
[basecm11->device*[switch001*]->accesssettings*]% set password < password>
[basecm11->device*[switch001*]->accesssettings*]% commit
```

###### Managing, installing and updating the firmware package in BCM for the DGX GB200 and GB300:

BCM can display information about the uploaded firmware files with the `firmware info` command, for both a compute tray device and a switch tray device:

**Example**

```bash
[basecm11->device[node001]]% firmware info
Device   Filename                        Component      Version                          State
-------- ------------------------------- -------------- -------------------------------- --------
node001  nvfw_DGX-GBX00_...fwpkg         GB200-BMC      DGX-GBX00_0023_250901.1.0_cus...  available
node001  nvfw_HGX-GBX00_...fwpkg         GB200-Compute  HGX-GBX00_0023_250908.1.0_cus...  available
[basecm11->device[switch001]]% firmware info
Device     Filename                      Component      Version                          State
---------- ----------------------------- -------------- -------------------------------- --------
switch001  nvfw_GB200-P4978_0004_...     GB200-Switch   GB200-P4978_0004_250821.1.0       available
switch001  nvfw_GB200-P4978_0006_...     GB200-Switch   GB200-P4978_0006_250710.1.1       available
switch001  nvfw_GB200-P4978_0007_...     GB200-Switch   GB200-P4978_0007_250831.1.0       available
```

The `firmware status` command displays the current firmware versions for the compute tray:

**Example**

```bash
[basecm11->device]% firmware status -n node001
Device   Filename Component               Version                    State    Progress
-------- -------- ----------------------- -------------------------- -------- --------
node001           CX8_0                   40.46.3048                 current  N/A
node001           CX8_1                   40.46.3048                 current  N/A
node001           CX8_2                   40.46.3048                 current  N/A
node001           CX8_3                   40.46.3048                 current  N/A
node001           FW_BMC_0                GB200Nvl-25.06-A            current  N/A
node001           FW_CPLD_0               0x00 0x0b 0x04 0x02         current  N/A
node001           FW_CPLD_1               0x00 0x0b 0x04 0x02         current  N/A
node001           FW_ERoT_BMC_0           01.04.0031.0000_n04         current  N/A
node001           HGX_FW_BMC_0            GB200Nvl-25.06-A            current  N/A
node001           HGX_FW_CPLD_0           0.22                        current  N/A
node001           HGX_FW_CPU_0            02.04.12                    current  N/A
node001           HGX_FW_CPU_1            02.04.12                    current  N/A
node001           HGX_FW_ERoT_BMC_0       01.04.0031.0000_n04         current  N/A
node001           HGX_FW_ERoT_CPU_0       01.04.0031.0000_n04         current  N/A
node001           HGX_FW_ERoT_CPU_1       01.04.0031.0000_n04         current  N/A
node001           HGX_FW_ERoT_FPGA_0      01.04.0008.0000_n04         current  N/A
node001           HGX_FW_ERoT_FPGA_1      01.04.0008.0000_n04         current  N/A
node001           HGX_FW_FPGA_0           1.20                        current  N/A
node001           HGX_FW_FPGA_1           1.20                        current  N/A
node001           HGX_FW_GPU_0            97.00.B9.00.68              current  N/A
node001           HGX_FW_GPU_1            97.00.B9.00.68              current  N/A
node001           HGX_FW_GPU_2            97.00.B9.00.68              current  N/A
node001           HGX_FW_GPU_3            97.00.B9.00.68              current  N/A
node001           HGX_InfoROM_GPU_0       G548.0201.00.06             current  N/A
node001           HGX_InfoROM_GPU_1       G548.0201.00.06             current  N/A
node001           HGX_InfoROM_GPU_2       G548.0201.00.06             current  N/A
node001           HGX_InfoROM_GPU_3       G548.0201.00.06             current  N/A
node001           HGX_PCIeSwitchConfig_0  01151024                    current  N/A
node001           NIC_1                   32.43.2408                  current  N/A
node001           UEFI                    buildbrain-gcid-41193377    current  N/A
```

For the GB300, the output is nearly identical; the only difference is that `NIC_1` in the preceding table is reported as `NIC_0` on the GB300 compute tray.

The NVLink switch tray reports its own, shorter set of components:

**Example**

```bash
[basecm11->device]% firmware status -n switch001
Device     Filename Component    Version              State    Progress
---------- -------- ------------ -------------------- -------- --------
switch001           ASIC         35.2014.1724          current  N/A
switch001           BIOS         0ACTV_00.01.017       current  N/A
switch001           BMC          88.0002.1040          current  N/A
switch001           CPLD1        CPLD000370_REV0300    current  N/A
switch001           CPLD2        CPLD000377_REV0500    current  N/A
switch001           CPLD3        CPLD000373_REV0205    current  N/A
switch001           CPLD4        CPLD000390_REV0200    current  N/A
switch001           EROT         01.04.0026.0000_n04   current  N/A
switch001           EROT-ASIC1   01.04.0026.0000_n04   current  N/A
switch001           EROT-ASIC2   01.04.0026.0000_n04   current  N/A
switch001           EROT-BMC     01.04.0026.0000_n04   current  N/A
switch001           EROT-CPU     01.04.0026.0000_n04   current  N/A
switch001           EROT-FPGA    01.04.0026.0000_n04   current  N/A
switch001           FPGA         0.1A                  current  N/A
switch001           SSD          CE00A400              current  N/A
switch001           transceiver  N/A                   current  N/A
```

The NVLink switch tray hardware, and so this output, is the same for GB200 and GB300 racks.

Components are updated the same way as for the DGX H100, using the `firmware flash` command. Each firmware package must be flashed with its own `firmware flash` invocation: the compute tray has two packages to flash (`DGX-GBX00` for the BMC, EROT, and CPLD; then `HGX-GBX00` for the HGX components), and the NVLink switch tray has three (`GB200-P4978_0004` for the BMC, EROT, and FPGA; `GB200-P4978_0006` for the SBIOS and EROT; then `GB200-P4978_0007` for the CPLD). Flashing only some of the packages leaves the tray partially updated.

**Example**

```bash
[basecm11->device[node001]]% firmware flash nvfw_DGX-GBX00_0023_250901.1.0_custom_prod-signed.fwpkg
Device           flashing                                                Result   Error
---------------- ------------------------------------------------------- -------- ----------
node001          nvfw_DGX-GBX00_0023_250901.1.0_custom_prod-signed.fwpkg good

[basecm11->device[node001]]% firmware flash nvfw_HGX-GBX00_0023_250908.1.0_custom_prod-signed.fwpkg
Device           flashing                                                Result   Error
---------------- ------------------------------------------------------- -------- ----------
node001          nvfw_HGX-GBX00_0023_250908.1.0_custom_prod-signed.fwpkg good
```

The NVLink switch tray is flashed the same way, once per package:

**Example**

```bash
[basecm11->device[switch001]]% firmware flash nvfw_GB200-P4978_0004_250821.1.0_prod-signed.fwpkg
Device           flashing                                           Result   Error
---------------- -------------------------------------------------- -------- ----------
switch001        nvfw_GB200-P4978_0004_250821.1.0_prod-signed.fwpkg good

[basecm11->device[switch001]]% firmware flash nvfw_GB200-P4978_0006_250710.1.1_prod-signed.fwpkg
Device           flashing                                           Result   Error
---------------- -------------------------------------------------- -------- ----------
switch001        nvfw_GB200-P4978_0006_250710.1.1_prod-signed.fwpkg good

[basecm11->device[switch001]]% firmware flash nvfw_GB200-P4978_0007_250831.1.0_prod-signed.fwpkg
Device           flashing                                           Result   Error
---------------- -------------------------------------------------- -------- ----------
switch001        nvfw_GB200-P4978_0007_250831.1.0_prod-signed.fwpkg good
```

Activation after flashing follows the same AC power cycle procedure as for the DGX H100 ([here](#ac-and-dc-power-cycling-for-the-dgx-h100)).

**Managing iLO Firmware Via Base View:**  Firmware for HPE iLO nodes can also be managed from Base View, using the same underlying firmware upload and flash operations as the `cmsh` `firmware` command described earlier in this section. There is no dedicated navigation item for firmware management. Instead, `Manage Firmware` is offered as a bulk action from any device grid in Base View (for example `Devices`, or the device list within a category, node group, or configuration overlay), as well as from the `Categories`, `Node Groups`, and `Configuration Overlays` list pages themselves. On those list pages, more than one category, node group, or configuration overlay can be selected at once. Base View then expands the selection to every compute node the selected items contain, and manages firmware across that whole set in a single pass. This is typically a more convenient way to flash firmware across many nodes at once than selecting them individually from a device grid.

Selecting one or more nodes and clicking `Manage Firmware` opens a dialog with the following steps:

1. **Select Firmware Repository:** a grid lists the firmware package files available on the head node. More than one package can be selected at once, one file per hardware component. Click `Upload` to continue.

2. **Firmware Upload Summary:** a totals panel (Total, Unchanged, Pending, Finished, Failed) and a grid of the selected nodes and components are shown, with their current and upload firmware versions and status. Once the upload has finished, click `Flash` to continue.

3. **Firmware Flash Summary:** a grid shows live flashing progress for each node and component as a percentage, until each component reaches its final state. The dialog cannot be closed until flashing completes.

No Dry Run step is offered in this dialog for iLO.

**Managing GB200, GB300 And DGX Firmware Via Base View:**  Firmware for GB200, GB300, and DGX nodes can also be managed from Base View, using the same `Manage Firmware` bulk action, and the same underlying firmware flash operations as the `cmsh` `firmware` command described earlier in this section. Flashing fails without an active NVIDIA Mission Control license, and the error returned states this.

Selecting one or more nodes and clicking `Manage Firmware` opens the same **Select Firmware Repository** screen used for iLO, but only one firmware package can be selected at a time here, matching the one-component-at-a-time flashing the `cmsh` `firmware` command also requires for these platforms. Two buttons are offered instead of `Upload`:

* **Dry Run:** pretends to carry out the flash, and opens a **Dry Run** screen. This screen shows a grid of the affected nodes and components, with their current version, the package version, and whether each is already up to date. Rows that are not up to date are highlighted. A **Force Install** checkbox is offered here, equivalent to the `cmsh` `firmware` command’s `--force` option and needed to force a downgrade or a re-flash. Checking it requires confirming a warning first. From this screen, click `Flash` to continue.

* **Flash:** can be clicked directly from the **Select Firmware Repository** screen, skipping Dry Run, or from the Dry Run screen once its results have been reviewed. Either way, flashing itself is tracked to completion on the same **Firmware Flash Summary** screen used for iLO.

For 11.34.0, Dry Run does not work correctly on these platforms; this is fixed in 11.35.0. Until then, Flash should be used directly rather than Dry Run.

Base View does not currently offer an equivalent of the `cmsh` `firmware` command’s `remove` operation for iLO, or a way to narrow a flash to named component targets the way the `cmsh` `firmware` command’s `--targets` option does for these platforms; both operations are only available via `cmsh`.

**DGX B200 and B300 firmware updates:**

Procedures to upgrade DGX firmware components on the DGX B200 and B300 hardware can be carried out once the hardware is recognized in BCM. The procedure generally follows the firmware upgrade outlined for DGX H100 hardware ([here](#a-gpu-tray-upgrade-example-on-the-dgx-h100)). More details specific to the hardware can be found at:

* [https://docs.nvidia.com/dgx/dgxb200-fw-update-guide/about.html](https://docs.nvidia.com/dgx/dgxb200-fw-update-guide/about.html)

* [https://docs.nvidia.com/dgx/dgxb300-fw-update-guide/index.html](https://docs.nvidia.com/dgx/dgxb300-fw-update-guide/index.html)

## 14.6  Hardware Match Check With The `hardware-profile` Data Producer

Often a large number of identical nodes may be added to a cluster. In such a case it is a good practice to check that the hardware matches what is expected. This can be done easily as follows:

1. The new nodes, say node129 to node255, are committed to a newly-created category `newbunch` as follows (output truncated):

   ```bash
   [root@basecm11 ~]# cmsh -c "category add newbunch; commit"
   [root@basecm11 ~]# for i in {129..255}
   > do
   > cmsh -c "device; set node00$i category newbunch; commit"
   > done
   Successfully committed 1 Devices
   Successfully committed 1 Devices
   ```

   The preceding loop is easy to construct, and works, but it is quite slow for larger clusters, due to the time wasted in opening up `cmsh` and carrying out a `commit` command during each iteration of the for loop.

   For larger clusters the offending `for` loop can be replaced with a more elegant, but slightly trickier:

   ```bash
   (echo device;
    for i in {129..255}; do
    echo "set node00$i category newbunch"
    done
    echo "commit") | cmsh
   ```

2. The hardware profile of one of the new nodes, say node129, is saved into the category `newbunch`. This is done using the `node-hardware-profile` health check script:

   **Example**

   ```bash
   [root@basecm11 ~]# /cm/local/apps/cmd/scripts/healthchecks/node-hardware-profile -n node129 -s newbunch
   ```

   The profile is intended to be the reference hardware against which all the other nodes should match, and is saved under the directory `/cm/shared/apps/cmd/hardware-profiles/`, and further under the directory name specified by the `-s` option, which in this case is `newbunch`.

3. The `hardware-profile` data producer (section [10.2.10](/admin/monitoring#10210-data-producer)) can then be enabled, and the sampling frequency set as follows:

   ```bash
   [root@basecm11 ~]# cmsh
   [basecm11]% monitoring setup use hardware-profile
   [basecm11->monitoring->setup[hardware-profile]]% set interval 600; set disabled no; commit
   ```

   The `hardware-profile` data producer should also be set to the category `newbunch` created in the earlier step. This can be done by creating a category group within the `nodeexecutionfilters` submode. Within that group, categories can be set for where the hardware check is to run. For the example, it is just run on one category, `newbunch`:

   ```bash
   [basecm11->monitoring->setup[hardware-profile]]% nodeexecutionfilters
   [basecm11->...-profile]->nodeexecutionfilters]% add category filterhwp
   [basecm11->...-profile]->nodeexecutionfilters*[filterhwp*]]% set categories newbunch
   [basecm11->...-profile]->nodeexecutionfilters*[filterhwp*]]% commit
   ```

4. CMDaemon then automatically alerts the administrator if one of the nodes does not match the hardware of that category during the first automated check. In the unlikely case that the reference node is itself faulty, then that will also be obvious because all—or almost all, if more nodes are faulty—of the other nodes in that category will then be reported “faulty” during the first check.

## 14.7  Serial Over LAN Console Access

Direct console access to nodes is not always possible. Other possibilities to access the node are:

1. **SSH access via an ssh client.** This requires that an `ssh` server runs on the node and that it is accessible via the network. Access can be via one of the following options:

   * a regular SSH client, run from a `bash` shell

   * via an `ssh` command run from the `device` mode of `cmsh`

   * via an `ssh` terminal launched from Base View via the navigation path:

     `Devices` > `Nodes` > *node* > `Connect` > `ssh`.

2. **Remote shell via CMDaemon.** This is possible if CMDaemon is running on the node and accessible via Base View or `cmsh`.

   * In Base View, An interactive root shell session can be started up on a node via the navigation path:

     `Devices` > `Nodes` > *node* > `Connect` > `Root shell`.

     This session is connected to the node via CMDaemon, and runs `bash` by default.

   * For `cmsh`, in `device` mode, running the command `rshell node001` launches an interactive bash session connected to node001 via CMDaemon.

3. **Connecting via a serial over LAN console.** If a serial console is configured, then a serial over LAN (SOL) console can be accessed from `cmsh` (`rconsole`).

Item 3 in the preceding list, SOL access, is a useful low-level access method that is covered next more thoroughly with:

* some background notes on serial over LAN console access (section [14.7.1](#1471-background-notes-on-serial-console-and-sol))

* the configuration of SOL with Base View (section [14.7.2](#1472-sol-console-configuration-with-base-view))

* the configuration of SOL with `cmsh` (section [14.7.3](#1473-sol-console-configuration-and-access-with-cmsh))

* the `conman` SOL logger and viewer (section [14.7.4](#1474-the-conman-serial-console-logger-and-viewer))

### 14.7.1  Background Notes On Serial Console And SOL

Serial ports are data ports that can usually be enabled or disabled for nodes in the BIOS.

If the serial port of a node is enabled, it can be configured in the node kernel to redirect a console to the port. The serial port can thus provide what is called serial console access. That is, the console can be viewed using a terminal software such as minicom (in Linux) or Hyperterminal (in Windows) on another machine to communicate with the node via the serial port, using a null-modem serial cable. This has traditionally been used by system administrators when remote access is otherwise disabled, for example if ssh access is not possible, or if the TCP/IP network parameters are not set up right.

While traditional serial port console access as just described can be useful, it is inconvenient, because of having to set arcane serial connection parameters, use the relatively slow serial port and use a special serial cable. Serial Over LAN (SOL) is a more recent development of serial port console access, which uses well-known TCP/IP networking over a faster Ethernet port, and uses a standard Ethernet cable. SOL is thus generally more convenient than traditional serial port console access. The serial port DB-9 or DB-25 connector and its associated 16550 UART chip rarely exist on modern servers that support SOL, but they are nonetheless usually implied to exist in the BIOS, and can be “enabled” or “disabled” there, thus enabling or disabling SOL.

SOL is a feature of the BMC (Baseboard Management Controller) for IPMI 2.0 and iLO. For DRAC, CIMC, and Redfish, SOL via IPMI is used. SOL is enabled by configuring the BMC BIOS. When enabled, data that is going to the BMC serial port is sent to the BMC LAN port. SOL clients can then process the LAN data to display the console. As far as the node kernel is concerned, the serial port is still just behaving like a serial port, so no change needs to be made in kernel configuration in doing whatever is traditionally done to configure serial connectivity. However, the console is now accessible to the administrator using the SOL client on the LAN.

SOL thus allows SOL clients on the LAN to access the Linux serial console if

1. SOL is enabled and configured in the BMC BIOS

2. the serial console is enabled and configured in the node kernel

3. the serial port is enabled and configured in the node BIOS

The BMC BIOS, node kernel, and node BIOS therefore all need to be configured to implement SOL console access.

#### 14.7.1.1  Background Notes: BMC BIOS Configuration

The BMC BIOS SOL values are usually enabled and configured as a submenu or pop-up menu of the node BIOS. These settings must be manually made to match the values in BCM, or vice versa.

During a factory reset of the node, it is likely that a SOL configuration in BCM will no longer match the configuration on the node BIOS after the node boots. This is because BCM cannot configure these. This is in contrast to the IP address and user authentication settings of the BMC (section [3.7](/admin/configuring#37-configuring-bmc-ipmiilodraccimcredfish-interfaces)), which BCM is able to configure on reboot.

#### 14.7.1.2  Background Notes: Node Kernel Configuration

Sections [14.7.2](#1472-sol-console-configuration-with-base-view) and [14.7.3](#1473-sol-console-configuration-and-access-with-cmsh) explain how SOL access configuration is set up for the node kernel using Base View or `cmsh`. SOL access configuration on the node kernel is serial access configuration on the node kernel as far as the system administrator is concerned; the only difference is that the word “serial” is replaced by “SOL” in BCM’s Base View and `cmsh` front ends to give a cluster perspective on the configuration.

#### 14.7.1.3  Background Notes: Node BIOS Configuration

Since BIOS implementations vary, and serial port access is linked with SOL access in various ways by the BIOS designers, it is not possible to give short and precise details on how to enable and configure them. The following rules-of-thumb, if followed carefully, should allow most BMCs to be configured for SOL access with BCM:

* Serial access, or remote access via serial ports, should be enabled in the BIOS, if such a setting exists.

* The node BIOS serial port settings should match the node configuration SOL settings ( section [14.7.3](#1473-sol-console-configuration-and-access-with-cmsh)). That means, items such as “`SOL speed`”, “`SOL Flow Control`”, and “`SOL port`” in the node configuration must match the equivalent in the node BIOS. Reasonable values are:

  * SOL speed: 115200bps. Higher speeds are sometimes possible, but are more likely to have problems.

  * SOL flow control: On. It is however unlikely to cause problems if flow control is off in both.

  * SOL port: COM1 (in the BIOS serial port configuration), corresponding to ttyS0 (in `x86_64`) or ttyAMA0 (in `aarch64`) in the node kernel serial port configuration. Alternatively, COM2, corresponding to ttyS1 or ttyAMA1. Sometimes, the BIOS configuration display indicates SOL options with options such as: “`COM1 as SOL`”, in which case such an option should be selected for SOL connectivity.

  * Terminal type: VT100 or ANSI.

* If there is an option for BIOS console redirection after BIOS POST, it should be disabled.

* If there is an option for BIOS console redirection before or during BIOS POST, it should be enabled.

* The administrator should be aware that the BMC LAN traffic, which includes SOL traffic, can typically run over a dedicated NIC or over a shared NIC. The choice of dedicated or shared is toggled, either in the BIOS, or via a physical toggle, or both. If BMC LAN traffic is configured to run on the shared NIC, then just connecting a SOL client with an Ethernet cable to the dedicated BMC NIC port shows no console.

* The node BIOS values should manually be made to match the values in BCM, or vice versa.

### 14.7.2  SOL Console Configuration With Base View

In Base View, SOL configuration settings can be carried out per image via the navigation path `Provisioning` > `Software Images` > *image* > `Edit` > `Settings`

If the `Enable SOL` option is set to `Yes` then the kernel option to make the Linux serial console accessible is used after the node is rebooted.

This means that if the serial port and SOL are enabled for the node hardware, then after the node reboots the Linux serial console is accessible over the LAN via an SOL client.

If SOL is correctly configured in the BIOS and in the image, then access to the Linux serial console is possible via the `minicom` serial client running on the computer (from a `bash` shell for example), or via the `rconsole` serial client running in `cmsh`.

### 14.7.3  SOL Console Configuration And Access With `cmsh`

In `cmsh`, the serial console kernel option for a software image can be enabled within the `softwareimage` mode of `cmsh`. For the default image of `default-image`, this can be done as follows:

**Example**

```bash
[root@basecm11 ~]# cmsh
[basecm11]% softwareimage use default-image

[basecm11->softwareimage[default-image]]% set enablesol yes
[basecm11->softwareimage*[default-image*]]% commit
```

The SOL settings for a particular image can be seen with the `show` command:

```bash
[basecm11->softwareimage[default-image]]% show | grep SOL
Parameter                      Value
------------------------------ --------------
Enable SOL                     yes
SOL Flow Control               yes
SOL Port                       ttyS1
SOL Speed                      115200
```

Values can be adjusted if needed with the `set` command. The value for `SOL Port` is normally `ttyS0` for `x86_64` images, and `ttyAMA0` for `arch64` images.

On rebooting the node, the new values are used.

To access a node via an SOL client, the node can be specified from within the `device` mode of `cmsh`, and the `rconsole` command run on `cmsh` on the head node:

**Example**

```bash
[root@basecm11 ~]# cmsh
[basecm11]% device use node001
[basecm11->device[node001]]% rconsole
screen cleared and the following conman output is displayed:
===============================================================================
conman
To exit IPMI SOL, type <ENTER> "&" "."
===============================================================================

<ConMan> Connection to console [node001] opened.
```

If at this point, there is no further response in `conman` on the console after pressing the `<ENTER>` key, then there is a communication failure, probably due to a misconfigured communication parameter. This could happen, for example, if the serial port `ttyS1` has been set, but the node is connected on `ttyS0`. Setting the value of `SOL Port` to `ttyS0` and rebooting the node to pick up the new value, would solve that issue, so that pressing the `<ENTER>` key, would display the node console:

**Example**

```bash
Ubuntu 18.04.2 LTS node001 ttyS0

node001 login:
```

### 14.7.4  The `conman` Serial Console Logger And Viewer

In BCM, the console viewer and logger service `conman` is used to connect to an SOL console and log the console output. If the “`Enable SOL`” option in Base View, or if the `enablesol` parameter in `cmsh` is enabled for the software image, then the `conman` configuration is written out and the `conman` service is started.

#### 14.7.4.1  Logging The Serial Console

The data seen at the serial console is then logged via SOL to the head node after reboot. For each node that has logging enabled, a log file is kept on the head node. For example, for `node001` the log file would be at `/var/log/conman/node001.log`. To view the logged console output without destroying terminal settings, using `less` with the `-R` option is recommended, as in: `less -R /var/log/conman/node001.log`.

#### 14.7.4.2  Using The Serial Console Interactively

**Viewing quirk during boot:** In contrast to the logs, the console viewer shows the initial booting stages of the node as it happens. There is however a quirk the system administrator should be aware of:

Normally the display on the physical console is a copy of the remote console. However, during boot, after the remote console has started up and been displaying the physical console for a while, the physical console display freezes. For the Linux 2.6 kernel series, the freeze occurs just before the ramdisk is run, and means that the display of the output of the launching `init.d` services is not seen on the physical console (figure [14.2](#fig-solphysicalconsolefreeze)).

![Physical Console Freeze During SOL Access](/base-command-manager/product-manuals/_fern-files/nvidia-bcm-manuals.docs.buildwithfern.com/fbd703d2b464182b85ac9ac20742556e243a92beb49b63b096ed37ef72de04c6/_dot_dot_/_dot_dot_/_dot_dot_/_dot_dot_/_dot_dot_/_dot_dot_/tmp/tmp-465-wPoXzKKBLZez/latextofern/fern/assets/figures/solphysicalconsolefreeze.png)

*Figure 14.2: Physical Console Freeze During SOL Access*

The freeze is only a freeze of the display, and should not be mistaken for a system freeze. It occurs because the kernel is configured during that stage to send to only one console, and that console is the remote console. The remote console continues to display its progress (figure [14.3](#fig-solremoteconsoleprogress)) during the freeze of the physical console display.

![Remote Console Continues During SOL Access During Physical Console Freeze](/base-command-manager/product-manuals/_fern-img/bb1df747724f5f1a27f86a78aad866f5d93098f1855adccd4f2789cc785b7e56.webp)

*Figure 14.3: Remote Console Continues During SOL Access During Physical Console Freeze*

Finally, just before login is displayed, the physical console once more (figure [14.4](#fig-solphysicalconsoleunfreeze)) starts to display what is on the remote console (figure [14.5](#fig-solremoteconsoleendstate)).

![Physical Console Resumes After Freeze During SOL Access](/base-command-manager/product-manuals/_fern-img/bc97029b4e77074e437d0587fa43d866cadb0190fe270a9b0ca15fd19c0dba63.webp)

*Figure 14.4: Physical Console Resumes After Freeze During SOL Access*

![Remote Console End Display After Boot](/base-command-manager/product-manuals/_fern-img/7779b5e4299c9ed4684f8c402afed296bd20410ca347d08a9a1fefcd92beb36d.webp)

*Figure 14.5: Remote Console End Display After Boot*

The physical console thus misses displaying several parts of the boot progress.

**Exit sequence:** The `conman` console viewer session can be exited with the sequence `&.` (the last entry in the sequence being a period). Strictly speaking, the `&.` sequence must actually be preceded by an \<*ENTER*>.

**The console buffer issue when accessing the remote console:** A feature of SOL console clients is that the administrator is not presented with any text prompt from the node that is being accessed. This is useful in some cases, and can be a problem in others.

An example of the issue is the case where the administrator has already logged into the console and typed in a command in the console shell, but has no intention of pressing the \<*ENTER*> key until some other tasks are first carried out. If the connection breaks at this point, then the command typed in is held in the console shell command buffer, but is not displayed when a remote serial connection is re-established to the console—the previously entered text is invisible to the client making the connection. A subsequent \<*ENTER*> would then attempt to execute the command. This is why an \<*ENTER*> is not sent as the last key sequence during automated SOL access, and it is left to the administrator to enter the appropriate key strokes.

To avoid commands in the console shell buffer inadvertently being run when taking over the console remotely, the administrator can start the session with a \<*CTRL*>`-u` to clear out text in the shell before pressing \<*ENTER*>.

## 14.8  Managing Raw Monitoring Data

From NVIDIA Base Command Manager version 8.0 onward, the raw monitoring data values are stored as binary data under `/var/spool/cmd/monitoring` instead of as binary data within MySQL or MariaDB. The reason behind this change was to significantly increase performance. The monitoring subsystem in BCM was thoroughly rewritten for this change.

### 14.8.1  Monitoring Subsystem Disk Usage With The `monitoringinfo --storage` Option

The disk usage by the monitoring subsystem can be viewed using the `monitoringinfo` command with the `--storage` option:

**Example**

```bash
[basecm11->device]% monitoringinfo master --storage
Storage                     Elements   Disk size    Usage    Free disk
--------------------------- ---------- ------------ -------- ------------
Mon::Storage::Engine        1,523      1.00 GiB     1.28%    14.1 GiB
Mon::Storage::Message       1          16.0 MiB     0.000%   -
Mon::Storage::RepositoryId  1,528      47.7 KiB     100.0%   -
```

The Engine component stores the raw monitoring data. It grows in 1GB increments each time its usage reaches 100%.

### 14.8.2  Estimating The Required Size Of The Storage Device

The final size of the monitoring directory can be estimated with the script `cm-monitoring-disk-usage.py`.

The size estimate assumes that there are no changes in configuration, such as enabling advanced metrics for jobs, or increasing the maximum number of labeled entities, or large numbers of running jobs.

The size estimate value is the maximum value it will take if the cluster runs forever. It is therefore an over-estimate in practice.

**Example**

```bash
[root@basecm11 ~]# /cm/local/apps/cmd/scripts/monitoring/cm-monitoring-disk-usage.py
Number of used entities:      10
Number of used measurables:   286
Number of measurables:        286
Number of data producers:     98
Number of consolidators:      2

Current monitoring directory: /var/spool/cmd/monitoring
Monitoring directory size:    1.024 GB
Maximal directory size:       1.409 GB
```

### 14.8.3  Moving Monitoring Data Elsewhere

A procedure to move monitoring data from the default `/var/spool/cmd/monitoring/` directory to a new directory is as follows:

1. A new directory in which monitoring should be saved is picked.

   The block storage device for the directory should not be a shared DAS (Direct Attached Storage, such as a locally attached drive) or a NAS (Network Attached Storage, such as NFS or Lustre which work over a network connection). That is because if there is an outage, then:

   * If such a DAS storage becomes unavailable at some time, then CMDaemon assumes that no monitoring data values exist, and creates an empty data file on the local storage. If the DAS storage comes back and is mounted again, then it hides the underlying files, which would lead to discontinuous values and related issues.

   * If such a NAS storage is used, then an outage of the NAS can make CMDaemon unresponsive as it waits for input and output. In addition, when CMDaemon starts with a NAS storage, and if the NAS is unavailable for some reason, then an inappropriate mount may happen as in the DAS storage case, leading to discontinuous values and related issues.

2. The `MonitoringPath` directive ([here](/admin/cmdconf#c85-monitoringpath-directive)) is given the new directory as its value.

3. CMDaemon is stopped (`systemctl stop cmd`).

4. The `/var/spool/cmd/monitoring/` directory is moved to the new directory.

5. CMDaemon is restarted (`systemctl start cmd`).

### 14.8.4  Reducing Monitoring Data By Reducing Samples

Options to reduce the amount of monitoring data gathered include reducing the `Maximal age` and `Maximal samples` for data producers (section [10.4.1](/admin/monitoring#1041-monitoring-configuration-data-producers)) to smaller, but still non-zero values. The reduction automatically re-initializes the monitoring data collection in the background, after 30 minutes or so, so that existing data is removed, and the values reported by the `cm-monitoring-disk-usage.py` script (section [14.8.2](#1482-estimating-the-required-size-of-the-storage-device)) then show the new storage estimates for the monitoring data.

### 14.8.5  Deleting All Monitoring Data

A procedure to delete all monitoring data from the default `/var/spool/cmd/monitoring/` directory is as follows:

1. The CMDaemon service on all nodes can be stopped by running the following on the active head node:\
   `pdsh -g all systemctl stop cmd `

2. On both head nodes, the monitoring data is removed with:

   ```bash
                   rm -f /var/spool/cmd/monitoring/*
                   rm -f /var/spool/cmd/backup/*/var/spool/cmd/monitoring/*
   ```

3. On both head nodes, the associated database tables for the CMDaemon user must be cleared. These tables are linked at a low level with the files under the `.../spool/cmd/monitoring/` directories, which means that the tables and the directories must both be cleared or CMDaemon is likely to crash when restarted. Clearing the tables can be done with a MySQL session run on each head node.

   The CMDaemon database user is `cmdaemon` by default, but the value can be checked with a grep on the `cmd.conf` file:

   ```bash
   [root@basecm11 ~]# grep ^DBUser /cm/local/apps/cmd/etc/cmd.conf
   DBUser = "cmdaemon"
   ```

   Similarly, the password for the `cmdaemon` user can be found with a grep as follows:

   ```bash
   [root@basecm11 ~]# grep ^DBPass /cm/local/apps/cmd/etc/cmd.conf
   DBPass = "slarti8813bartfahrt"
   ```

   The monitoring measurables can then be deleted by running a session on each head node as follows:

   **Example**

   ```bash
   [root@basecm11 ~]# mysql -ucmdaemon -p
   Enter password:
   Welcome to the MariaDB monitor.  Commands end with ; or \g.
   Your MariaDB connection id is 2909
   Server version: 5.5.56-MariaDB MariaDB Server

   Copyright (c) 2000, 2017, Oracle, MariaDB Corporation Ab and others.

   Type 'help;' or '\h' for help. Type '\c' to clear the current input statement.

   MariaDB [(none)]> use cmdaemon;
   Database changed
   MariaDB [cmdaemon]> truncate MonitoringMeasurables;
   MariaDB [cmdaemon]> truncate MonitoringMeasurableMetrics;
   MariaDB [cmdaemon]> truncate MonitoringMeasurableHealthChecks;
   MariaDB [cmdaemon]> truncate MonitoringMeasurableEnums;
   MariaDB [cmdaemon]> truncate EntityMeasurables;
   MariaDB [cmdaemon]> truncate EnumMetricValues;
   MariaDB [cmdaemon]> truncate LabeledEntities;
   MariaDB [cmdaemon]> truncate JobInformation;
   MariaDB [cmdaemon]> truncate WlmJobPowerUsageSettingsCpuPowerMetrics;
   MariaDB [cmdaemon]> truncate WlmJobPowerUsageSettingsGpuPowerMetrics;
   MariaDB [cmdaemon]> truncate WlmJobPowerUsageSettingsNodePowerMetrics;
   MariaDB [cmdaemon]> truncate WlmJobPowerUsageSettingsPowerUnderAllocationMetrics;
   MariaDB [cmdaemon]> exit
   repeat on other head node
   ```

4. On both head nodes, CMDaemon can then be restarted with:\
   `systemctl start cmd`

5. On the active head node, after the command:\
   `cmha status`\
   shows all is `OK`, the CMDaemon service can be started on all regular nodes again. The `OK` state should be achieved in about 15 seconds.

   The CMDaemon service is started with, for example:\
   `pdsh -g computenode systemctl start cmd`

## 14.9  Node Replacement

To replace an existing node with a new node, the node information can be updated via `cmsh`.

If the new MAC address is known, then it can set that for the node. If the MAC address is not known, then the existing entry can be cleared.

If the MAC address is not known ahead of time, then the node name for the machine should be selected when it is provisioning for the first time. The steps for a new node `node031` would be as follows:

**Example**

```bash
[root@basecm11 ~]# cmsh
[basecm11]% device use node0031
 if new mac address is known, then:
[basecm11->device[node031]]% set mac <new mac address>
 else if new mac address is not known:
[basecm11->device[node031]]% clear mac
 the changed setting in either case must be committed:
[basecm11->device[node031]]% commit
```

If the disk is the same size as the one that is being replaced, and everything else matches up, then this should be all that needs to be done

There is more information on the node installing system in section [5.4](/admin/provisioning#54-node-installer). How to add a large number of nodes at a time efficiently is described in that section. The methods used can include the `newnodes` command of `cmsh` ([here](/admin/provisioning#5423-the-newnodes-command)) and the `Nodes Identification` resource of Base View ([here](/admin/provisioning#5424-device-identification)).

## 14.10  Ansible And NVIDIA Base Command Manager

This section describes using Ansible with BCM. Using Ansible to install NVIDIA Base Command Manager is described in [section 3.4 of the *Installation Manual*](/installation/installing#34-head-node-installation-ansible-add-on-method).

### 14.10.1  An Overview Of Ansible

Ansible is a popular automated configuration management software.

The BCM administrator is expected to have some experience already with Ansible. The basic concepts are covered in the official Ansible documentation at [https://docs.ansible.com/ansible/latest/user_guide/basic_concepts.html](https://docs.ansible.com/ansible/latest/user_guide/basic_concepts.html), and further details are accessible from that site too.

As a reminder:

* Ansible is designed to administer groups of machines from an [*inventory*](https://docs.ansible.com/ansible/latest/user_guide/basic_concepts.html#inventory) of machines.

* An [Ansible *module*](https://docs.ansible.com/ansible/latest/user_guide/basic_concepts.html#modules) is code, usually in Python, that is executed by Ansible to carry out [Ansible *tasks*](https://docs.ansible.com/ansible/latest/user_guide/basic_concepts.html#tasks), usually on a remote node. The module returns values.

* An [Ansible *playbook*](https://docs.ansible.com/ansible/latest/user_guide/playbooks.html) is a YAML file. The file declares a configuration that is to be executed (“the playbook is followed”) on selected machines. The execution is usually carried out over SSH, by placing modules on the remote machine.

* Traditionally, official Ansible content was obtained as a part of milestone releases of Ansible Engine, (the Red Hat version of Ansible for the enterprise).

* Since Ansible version 2.10, the official way to distribute content is via Ansible content [*collections*](https://docs.ansible.com/ansible/latest/user_guide/basic_concepts.html#collections). Collections are composed of Ansible playbooks, modules, module utilities and plugins. The collection is a formatted set of tools used to achieve automation with Ansible.

* The official Ansible list of collections is at [https://docs.ansible.com/ansible/latest/collections/index.html#list-of-collections](https://docs.ansible.com/ansible/latest/collections/index.html#list-of-collections). At the time of writing of this section (March 2022) there were 100 collections.

* Community-supported collections are also available, at `galaxy.ansible.com`.

#### 14.10.1.1  Picking Up The BCM Ansible Collections

In particular, the web interface at [https://galaxy.ansible.com/brightcomputing](https://galaxy.ansible.com/brightcomputing) shows the updated list of BCM Ansible collections.

From version 9.1 onward of BCM, the BCM Ansible collection naming scheme has been changed so that the name now indicates the BCM version number. This now makes it simpler for the cluster administrator to choose the right Ansible collection.

For example, to install the latest version of the BCM Ansible collection for a NVIDIA Base Command Manager 11 cluster, the following command can now be run:

```bash
    [root@basecm11 ~]# ansible-galaxy collection install brightcomputing.bcm110
```

### 14.10.2  A Simple Playbook Example

In this section, a playbook from the BCM collection is run.

#### 14.10.2.1  Preparations

To start with, Python is loaded, and Ansible installed:

```bash
[root@basecm11 ~]# module load python3
[root@basecm11 ~]# pip install ansible
```

#### 14.10.2.2  Running A Simple Playbook

The directory `/cm/local/examples/cmd/ansible` has several BCM Ansible playbook examples.

The Ansible playbook to add a user can be run. The playbook is simply:

```bash
[root@basecm11 ~]# cat /cm/local/examples/cmd/ansible/add-user.yaml
---
- hosts: all
  gather_facts: false
  tasks:
  collections:
    - brightcomputing.bcm110
  tasks:
  - name: create test-user
    user:
      name: test-user
      password: test-user-password
      profile: readonly
```

The latest NVIDIA Base Command Manager 11-compatible version of [the BCM Ansible collection is at `https://galaxy.ansible.com/brightcomputing/bcm110`](https://galaxy.ansible.com/brightcomputing/bcm110). It can be installed with the `ansible-galaxy` tool from the `galaxy.ansible.com` repository directly with:

```bash
    [root@basecm11 ~]# ansible-galaxy collection install brightcomputing.bcm110
```

#### 14.10.2.3  Documentation For The BCM Collection

The `brightcomputing.bcm110` documentation for modules can be explored using `ansible-doc` in the usual way, using the namespace. For example, for the `user` module in the `brightcomputing.bcm110` namespace, this would be (output truncated):

```bash
    [root@basecm11 ~]# ansible-doc brightcomputing.bcm110.user
> BRIGHTCOMPUTING.BCM110.USER
> (/root/.ansible/collections/ansible_collections/brightcomputing/bcm110/plugins/modules/user.py)

        User

    ADDED IN: version 9.2.0 of brightcomputing.bcm110

  * note: This module has a corresponding action plugin.

OPTIONS (= is mandatory):

- ID
        User ID number
        [Default: (null)]
        type: str

- cloneFrom
        The id or name of the entity that the new entity will be cloned from.
         (take effect only at entity creation)
        [Default: ]
        type: str

- email
...
```

The list of modules in the `brightcomputing.bcm110` collection can be viewed with `ansible-doc -l brightcomputing.bcm110`.

Almost all the modules are available as a pair. For such a pair, one module out of the pair is to query the attributes of the entity being dealt with by the pair, while the other module is to set the attributes.

#### 14.10.2.4  Running The Ansible Playbook

The `add-user` playbook can now be run with:

**Example**

```bash
[root@basecm11 ~]# ansible-playbook -ilocalhost, /cm/local/examples/cmd/ansible/add-user.yaml

PLAY [all]
*********************************************************************************************

TASK [create test-user]
*********************************************************************************************
changed: [localhost]

PLAY RECAP
*********************************************************************************************
localhost                  : ok=1    changed=1    unreachable=0    failed=0    skipped=0
rescued=0    ignored=0

```

The YAML code shows a user should be created after execution of the playbook. If unsure, the playbook can be run again. This should do no harm since well-formed playbooks are idempotent.

The new list of users can be verified with:

```bash
[root@basecm11 ~]# cmsh -c "user list"
Name (key)       ID (key)         Primary group    Secondary groups
---------------- ---------------- ---------------- ----------------
cmsupport        1000             cmsupport
test-user        1001             test-user
```

### 14.10.3  An Intermediate Playbook Example: Setting Up A Cluster For Demonstration Purposes

The simple playbook in the preceding section has the advantage of being a quick way for the administrator to be reasonably sure that Ansible is running as it should be.

An administrator who is intending to use Ansible is typically going to need to be more familiar with how Ansible playbooks can be used to define BCM infrastructure.

This section ([14.10.3](#14103-an-intermediate-playbook-example-setting-up-a-cluster-for-demonstration-purposes)) and the next ([14.10.4](#14104-a-more-complicated-playbook-example-creating-an-edge-site-and-related-properties)) aim to provide this familiarity. They should be a guide for users when they go about defining their own BCM infrastructure with Ansible, as well as a model for how to carry out Ansible tasks for BCM.

The example session in this section (section [14.10.3](#14103-an-intermediate-playbook-example-setting-up-a-cluster-for-demonstration-purposes)) is about a cluster administrator who wishes to prepare a playbook so that the default image is updated, and then have the cluster set up some new objects with default values. This is useful for testing out changes in the new objects. The idea being that the administrator has up-to-date nodes with default settings in the new objects, and which work to begin with. That makes the new objects suitable for demonstrations and for making changes to see how it affects the standard settings. It also provides the convenience of being able to refer back to the working defaults in the original objects if things go wrong with the demonstration objects.

The tasks to bring the cluster to the “demo” state are described next.

#### 14.10.3.1  Cloning The Image

The administrator now clones the default image. The idea being that further changes can be made on the cloned image later on, with the default image instance remaining unchanged, and available for comparison.

The YAML example `clone-software-image.yaml` provided with BCM can be displayed and used to carry out the cloning as shown in the following session:

```bash
[root@basecm11 ~]# cat /cm/local/examples/cmd/ansible/clone-software-image.yaml
---
- hosts: all
  gather_facts: false
  tasks:
    - name: clone a software image
      brightcomputing.bcm110.software_image:
        name: cloned-image
        cloneFrom: default-image
        path: /cm/images/cloned-image

[root@basecm11 ~] ansible-playbook -i localhost, /cm/local/examples/cmd/ansible/clone-software-image.yaml
```

#### 14.10.3.2  Cloning The Category

A clone of the `default` category, `democategory`, can be built with the `brightcomputing.bcm110.category` module:

```bash
[root@basecm11 ~]# cat clonedefaultcat.yaml
- hosts: all
  gather_facts: false

  tasks:
    - name: clone category
      brightcomputing.bcm110.category:
        name: democategory
        cloneFrom: default
[root@basecm11 ~] ansible-playbook -i localhost, clonedefaultcat.yaml
```

#### 14.10.3.3  Setting The Software Image In The Cloned Category To Be The Cloned Image

The software image in the cloned category can then be set to the `cloned-image` from earlier with:

```bash
[root@basecm11 ~]# cat setimageincat.yaml
- hosts: all
  gather_facts: false

  tasks:
    - name: set image in category
      brightcomputing.bcm110.category:
        name: democategory
        softwareImageProxy:
          parentSoftwareImage: cloned-image
[root@basecm11 ~] ansible-playbook -i localhost, setimageincat.yaml
```

#### 14.10.3.4  Setting The Regular Nodes To Be In The Cloned Category

The regular nodes `node001` and `node002` can be placed in the cloned category with:

```bash
[root@basecm11 ~]# cat setcatofnodes.yaml
- hosts: all
  gather_facts: false

  tasks:
    - name: list all nodes
      brightcomputing.bcm110.node_info:
        format: dict
        include_id: false
        for_update: true
      register: result

    - name: set head_node
      set_fact:
        all_nodes: "{{ result.nodes }}"

    - name: assign compute nodes to cloned category
      brightcomputing.bcm110.physical_node:
        hostname: "{{ item }}"
        mac: "{{ all_nodes[item].mac }}"
        category: democategory
      loop:
        - node001
        - node002
[root@basecm11 ~] ansible-playbook -i localhost, setcatofnodes.yaml
```

Without using Ansible, and using `cmsh` directly instead, the preceding placement could be carried out with:

```bash
[root@basecm11 ~] for i in {001..002}
do cmsh -c "device use node$i; set category democategory; commit"
done
```

### 14.10.4  A More Complicated Playbook Example: Creating An Edge Site And Related Properties

This section provides a more complicated BCM Ansible collection-based playbook, and elaborates upon how it is used.

The collection is first shown as a whole in the following section. Then less obvious portions from it are explained, with the help of number labels, in the sections after that, starting [here](#141042-topmost-part).

#### 14.10.4.1  The Collection

The full collection is as follows:

```bash
---
- hosts: all
  gather_facts: false
  vars:
    site:
      name: test-site
      secret: SECRET

    director:
      hostname: test-site-director
      mac: 00:11:22:33:44:55
      eth0_ip: 10.152.0.254
      eth1_ip: 10.161.0.254

    nodes:
      - hostname: edge-node-01
        mac: 00:11:22:33:44:01
        eth0_ip: 10.161.0.1

      - hostname: edge-node-02
        mac: 00:11:22:33:44:02
        eth0_ip: 10.161.0.2

      - hostname: edge-node-03
        mac: 00:11:22:33:44:03
        eth0_ip: 10.161.0.3

  pre_tasks:

    - name: set compute nodes for site
      set_fact:
        site_compute_nodes: "{{nodes | map(attribute='hostname') | list}}"

    - name: set nodes for site
      set_fact:
        site_nodes: "{{[director.hostname] + site_compute_nodes}}"

  tasks:
    # Network creation
    - name: create an external network
      brightcomputing.bcm110.network:
        state: present
        name: test-site-external_network
        type: EDGE_EXTERNAL
        baseAddress: 10.152.0.0
        broadcastAddress: 10.152.255.255
        netmaskBits: 16
        domainName: test-site-external_network
        management: true

    - name: create an internal network
      brightcomputing.bcm110.network:
          state: present
          type: EDGE_INTERNAL
          name: test-site-internal_network
          baseAddress: 10.161.0.0
          broadcastAddress: 10.161.255.255
          dynamicRangeStart: 10.161.16.0
          dynamicRangeEnd: 10.161.19.255
          netmaskBits: 16
          domainName: test-site-internal_network
          management: true
          bootable: true

    - name: create edge site software image
      brightcomputing.bcm110.software_image:
        name: my-software-image
        path: /cm/images/my-software-image
        cloneFrom: default-image

    - name: create edge director category
      brightcomputing.bcm110.category:
        name: edge_director_category
        softwareImageProxy:
          parentSoftwareImage: my-software-image
        fsmounts:
          - device: $localnfsserver:/cm/shared
            mountpoint:  /cm/shared
            filesystem: nfs
          - device: $localnfsserver:/home
            mountpoint:  /home
            filesystem: nfs
        state: present

    # Edge Director
    - name: create director physical node
      brightcomputing.bcm110.physical_node:
        state: present
        hostname: "{{director.hostname}}"
        partition: base
        interfaces_NetworkPhysicalInterface:
          - name: eth0
            ip: "{{ director.eth0_ip }}"
            network: test-site-external_network
          - name: eth1
            ip: "{{ director.eth1_ip }}"
            network: test-site-internal_network

        category: edge_director_category
        mac: "{{director.mac}}"
        managementNetwork: test-site-external_network
        provisioningInterface: eth0
        installBootRecord: true
        roles_EdgeDirectorRole:
          - name: edge_director_role
            openTCPPortsOnHeadNode: [636]
            externallyVisibleIp: 0.0.0.0
            externallyVisibleHeadNodeIp: 0.0.0.0
        roles_BootRole:
          - name: boot_role
            allowRamdiskCreation: true
        roles_StorageRole:
          - name: storage_role
        roles_ProvisioningRole:
          - name: provisioning_role
            allImages: LOCALDISK

    # Edge Nodes
    - name: create edge nodes
      brightcomputing.bcm110.physical_node:
        hostname: "{{item.hostname}}"
        softwareImageProxy:
          parentSoftwareImage: default-image
        interfaces_NetworkPhysicalInterface:
          - name: eth0
            ip: "{{item.eth0_ip}}"
            network: test-site-internal_network
        category: default
        mac: "{{item.mac}}"
        managementNetwork: test-site-internal_network
        installBootRecord: false
        provisioningInterface: eth0
        partition: base
      loop: "{{ nodes }}"

    - name: add test edge site
      brightcomputing.bcm110.edge_site:
        name: "{{site.name}}"
        secret: "{{site.secret}}"
        address: Springfield
        adminEmail: admin-west@email.com
        city: San Francisco
        contact: Admin
        country: USA
        notes: Note about the site
        state: present
        nodes: "{{site_nodes}}"
```

#### 14.10.4.2  Topmost Part

```bash
- hosts: all #(1)
  gather_facts: false #(2)
```

1. This is a standard Ansible playbook configuration item. It defines the group or host that the playbook is run on.

2. Fact gathering is skipped here, because there is no need to use any facts that Ansible usually gathers pre-playbook-run. As a bonus, skipping it makes execution faster.

#### 14.10.4.3  Pre_tasks Part

The `pre_tasks` section could have been made a part of the tasks section. However, making it a separate section has the benefit of separating real action from simple fact definition:

```bash
    - name: set compute nodes for site
      set_fact:
        site_compute_nodes: "{{nodes | map(attribute='hostname') | list}}" #(1)

    - name: set nodes for site
      set_fact:
        site_nodes: "{{[director.hostname] + site_compute_nodes}}" #(2)
```

1. In the preceding code, the Ansible templating capability is used to get the list of `compute_nodes` for the site that is to be created. The hostname attribute is extracted from every element of the `nodes` variable and then transformed into a list, and assigned to the `site_compute_nodes` variable.

2. The list that is created has all the nodes that are part of the site, which means the compute nodes as well as the director.

#### 14.10.4.4  The Tasks Part

**External and internal networks configuration:** The tasks section starts with networking definitions (tagged here with (1) and (2)). These are the external and internal networks that are needed for the edge site that is to be created.

```bash
    - name: create an external network    #(1)
      brightcomputing.bcm110.network:
        state: present
        name: test-site-external_network
        type: EDGE_EXTERNAL
        baseAddress: 10.152.0.0
        broadcastAddress: 10.152.255.255
        netmaskBits: 16
        domainName: test-site-external_network
        management: true

    - name: create an internal network     #(2)
      brightcomputing.bcm110.network:
          state: present
          type: EDGE_INTERNAL
          name: test-site-internal_network
          baseAddress: 10.161.0.0
          broadcastAddress: 10.161.255.255
          dynamicRangeStart: 10.161.16.0
          dynamicRangeEnd: 10.161.19.255
          netmaskBits: 16
          domainName: test-site-internal_network
          management: true
          bootable: true
```

The possible values for each entity attribute can be seen by running the `ansible-doc` command:

**Example**

```bash
$ ansible-doc brightcomputing.bcm110.network
```

**Director creation:** A category must exist for the edge director, or must be created before the director can be created. The following snippet takes care of that:

```bash
    - name: create edge site software image
      brightcomputing.bcm110.software_image:
        name: my-software-image
        path: /cm/images/my-software-image
        cloneFrom: default-image   #(1)

    - name: create edge director category
      brightcomputing.bcm110.category:
        name: edge_director_category
        softwareImageProxy:
          parentSoftwareImage: my-software-image    #(2)
        fsmounts:     #(3)
          - device: $localnfsserver:/cm/shared
            mountpoint:  /cm/shared
            filesystem: nfs
          - device: $localnfsserver:/home
            mountpoint:  /home
            filesystem: nfs
        state: present    #(4)
```

1. The `cloneFrom` attribute is used to create the new software image from the existing one, to avoid copying over all the values that are part of the original image. The `default-image` is used here, since it is guaranteed to be defined in a new cluster.

   The `cloneFrom` attribute only takes effect when the resource is not defined. This means that if the software image is already present, then using `cloneFrom` has no effect. Removing the image allows it to be re-created again using the cloneFrom attribute.

2. The declared software image (here it is `my-software-image`) is then used to define the director category.

3. The edge directory category attributes in the snippet are standard values that are normally assigned to a director category that is to be used by director nodes.

4. The default value for `state` is `present`, so the task has the same behavior if the `state` field is left out.

**Values for the director node:** The edge director node values can now be set

```bash
    - name: create director physical node
      brightcomputing.bcm110.physical_node:
        state: present
        hostname: "{{director.hostname}}"
        partition: base
        interfaces_NetworkPhysicalInterface:
          - name: eth0
            ip: "{{ director.eth0_ip }}"
            network: test-site-external_network
          - name: eth1
            ip: "{{ director.eth1_ip }}"
            network: test-site-internal_network

        category: edge_director_category
        mac: "{{director.mac}}"
        managementNetwork: test-site-external_network
        provisioningInterface: eth0
        installBootRecord: true
        roles_EdgeDirectorRole:  # (1)
          - name: edge_director_role
            openTCPPortsOnHeadNode: [636]
            externallyVisibleIp: 0.0.0.0
            externallyVisibleHeadNodeIp: 0.0.0.0
        roles_BootRole:
          - name: boot_role
            allowRamdiskCreation: true
        roles_StorageRole:
          - name: storage_role
        roles_ProvisioningRole:
          - name: provisioning_role
            allImages: LOCALDISK
```

In the preceding snippet, values are set for the physical node so that it functions correctly as a director on an edge site.

1. The director, just like the edge nodes, is just a physical node, with the role `EdgeDirectorRole` assigned to it, along with other relevant roles.

**The edge (compute) nodes definition:**

1. In the following snippet, the looping mechanism defines a physical node that corresponds to each declared compute node.

Each edge node belongs to the correct network.

```bash
    - name: create edge nodes
      brightcomputing.bcm110.physical_node:
        hostname: "{{item.hostname}}"
        softwareImageProxy:
          parentSoftwareImage: default-image
        interfaces_NetworkPhysicalInterface:
          - name: eth0
            ip: "{{item.eth0_ip}}"
            network: test-site-internal_network
        category: default
        mac: "{{item.mac}}"
        managementNetwork: test-site-internal_network
        installBootRecord: false
        provisioningInterface: eth0
        partition: base
      loop: "{{ nodes }}"  #(1)
```

**Edge site object creation:** The last part of the playbook creates the edge site object.

```bash
    - name: add test edge site
      brightcomputing.bcm110.edge_site:
        name: "{{site.name}}"
        secret: "{{site.secret}}"
        address: Springfield
        adminEmail: admin-west@email.com
        city: San Francisco
        contact: Admin
        country: USA
        notes: Note about the site
        state: present
        nodes: "{{site_nodes}}"    #(1)
```

The `site_nodes` variable, defined by the `set_fact` task, is assigned to the `nodes` attribute of an `edge_site` action.

Running this playbook on a fresh cluster should be enough to create a new edge site with the declared properties, even if the nodes are not physically present.

The state of the edge site can be checked with `cmsh` queries. It should be noted that the image creation step may take a few minutes, depending on how big `default-image` is.

## 14.11  Querying Hardware Information

Querying device hardware information is about finding information about the hardware details of nodes and devices managed within the cluster. Understanding device hardware information is essential for inventory management, troubleshooting, and ensuring proper hardware configuration.

The `sysinfo` command (section [3.19.4](/admin/configuring#3194-sysinfo-custom-scripts)) returns basic hardware information for a node, mostly from the OS, and using cached information.

Hardware information can also be queried using other commands available in `cmsh` device mode. These queries retrieve component details directly from the device management interfaces.

Section [14.11.1](#14111-hardware-inventory-information-hardwareinventoryinfo) describes using `hardwareinventoryinfo` to obtain a hardware inventory.

Section [14.11.2](#14112-pci-device-information-lspci) describes using the BCM `lspci` command to query PCI device information.

Section [14.11.3](#14113-eeprom-information-lseeprom) describes using the `lseeprom` command to query EEPROM interface information.

Section [14.11.4](#14114-accelerator-count-accelerators) describes using the `accelerators` command to query accelerator count information.

### 14.11.1  Hardware Inventory Information: `hardwareinventoryinfo`

A hardware inventory in accounting is taken to mean a list of items in stock in an office, a warehouse, a ship, or similar unit. In BCM `device` mode context, a hardware inventory is taken to mean the physical components installed in the cluster devices of a cluster. These physical components are components installed in a node or a switch. They can be CPUs, GPUs, network adapters, memory modules, as well as other hardware components.

The inventory data can be used for asset tracking, capacity planning, and verifying hardware configurations.

The `hardwareinventoryinfo` command uses Redfish protocol queries to display detailed hardware inventory information for a device. The information about hardware components includes the manufacturer, model, serial number, and part number for each component:

**Example**

```bash
[basecm11->device[node001]]% hardwareinventoryinfo
Device   Name     Manufacturer  Model                 Serial number      ...         Part number
-------  -------- ------------- --------------------- -------------------...-------  ---------------------
node001           NVIDIA        GB200 NVL             1870425000202      ...         699-25859-0311-200
node001  BMC      NVIDIA        GB200 NVL             1320325065530      ...         699-24764-0001-200
node001  CBC-0    Nvidia        18x1RU CBL Cartridge  1820025170551      ...         750-0591-000
node001  CBC-1    Nvidia        18x1RU CBL Cartridge  1820025170557      ...         750-0591-000
node001  CBC-2    Nvidia        18x1RU CBL Cartridge  1820025170552      ...         750-0591-000
node001  CBC-3    Nvidia        18x1RU CBL Cartridge  1820125170045      ...         750-0591-000
node001  CPLD-0   Intel         MAX10 10M08           NA                 ...         115-3953-000
node001  CPLD-0   Lattice       BP                    0x0044387556108c26 ...         999-0099-000
node001  CPLD-1   Lattice       BP                    0x0044387556107637 ...         999-0099-000
node001  CPLD-2   Lattice       IPEX                  0x0044387824104e2b ...         999-0099-000
node001  CPLD-3   Lattice       IPEX                  0x00443885661c8c3a ...         999-0099-000
node001  CPU0     NVIDIA        Grace A02P            0x000000017830A0420...7008100  692-2G548-0001-000
node001  CPU1     NVIDIA        Grace A02P            0x000000017830A0012...5000280  692-2G548-0001-000
node001  GPU0     NVIDIA        GB200 186GB HBM3e     1650625019617      ...         NA
node001  GPU1     NVIDIA        GB200 186GB HBM3e     1650625019617      ...         NA
node001  GPU2     NVIDIA        GB200 186GB HBM3e     1650625019220      ...         NA
node001  GPU3     NVIDIA        GB200 186GB HBM3e     1650625019220      ...         NA
node001  PDB      NVIDIA        P5859 B01             1870425000202      ...         699-25859-0311-200
```

The `hardwareinventoryinfo` command has options to run it per node, category, rack, and so on. The help text to the command (`help hardwareinventoryinfo`) provides details on these and other options.

### 14.11.2  PCI Device Information: `lspci`

The `lspci` command is run from `device` mode, and displays information about PCI devices connected to a device. The information includes the PCI device class, vendor, PCI device IDs, and whether the PCI device is a DPU or accelerator:

**Example**

```bash
[basecm11->device[node001]]% lspci
Hostname Class ID  Class          ... Vendor   ... Vendor ID  Device ID  Name        ... DPU  Accelerator
-------- --------- ---------------... ---------... ---------- ---------- ------------... ---- ------------
node001  0200      Ethernet contro... Intel Cor... 8086       1533       I210 Gigabit... no   no
node001  0200      Ethernet contro... Mellanox ... 15b3       a2dc       MT43244 Blue... no   no
node001  0200      Ethernet contro... Mellanox ... 15b3       a2dc       MT43244 Blue... no   no
node001  0207      Infiniband cont... Mellanox ... 15b3       1023       CX8 Family [... no   no
node001  0207      Infiniband cont... Mellanox ... 15b3       1023       CX8 Family [... no   no
node001  0207      Infiniband cont... Mellanox ... 15b3       1023       CX8 Family [... no   no
node001  0207      Infiniband cont... Mellanox ... 15b3       1023       CX8 Family [... no   no
node001  0300      VGA compatible ... ASPEED Te... 1a03       2000       ASPEED Graph... no   no
node001  0302      3D controller  ... NVIDIA Co... 10de       31c2       B300        ... no   yes
node001  0302      3D controller  ... NVIDIA Co... 10de       31c2       B300        ... no   yes
...
```

The `lspci` command has options to run it per node, category, rack, and so on. The help text to the command (`help lspci`) provides details on these and other options.

### 14.11.3  EEPROM Information: `lseeprom`

The `lseeprom` command is run from `device` mode, and displays EEPROM information for network interaces on a device. The information about transceiver modules includes the interface type, vendor, part number, serial number, connector type, and manufacturing date code:

**Example**

```bash
[basecm11->device[node001]]% lseeprom
Hostname  Interface       Type         Vendor  P/N            S/N            Connector    Date Code
--------- --------------- ------------ ------- -------------- -------------- ------------ ---------
node001   enP22p3s0f0np0  0x1e (QSFP+) NVIDIA  MMA1Z00-NS400  MT2526FT06847  MPO Parallel 250623
node001   enP22p3s0f1np1  0x1e (QSFP+) NVIDIA  MMA1Z00-NS400  MT2445FT09229  MPO Parallel 241105
...
```

The `lseeprom` command has options to run it per node, category, rack, and so on. The help text to the command (`help lseeprom`) provides details on these and other options.

### 14.11.4  Accelerator Count: `accelerators`

The `accelerators` command is run from `device` mode, and displays an overview of the number of accelerators, such as GPUS, on each device:

**Example**

```bash
[basecm11->device]% accelerators
Node                  Count
--------------------- -----
head1                 0
head2                 0
schedulernode         0
...
computenode001        4
computenode002        4
computenode003        4
...
```

The `accelerators` command has options to run it per node, category, rack, and so on. The help text to the command (`help accelerators`) provides details on these and other options.

## 14.12  The `cm-mysql-setup` Utility

### 14.12.1  Introduction

In order to manage `MySQL` databases on compute nodes, the NVIDIA Base Command Manager `cm-mysql-setup` utility has been introduced. It is a plugin that comes with the `cm-setup` package. It supports installation and configuration of MySQL on a single node, or on a primary/replica setup.

All distributions except Ubuntu 24 onward need a MySQL repository setup package to be downloaded from the MySQL site in advance to install the repositories for `MySQL Community Edition`. For Ubuntu, from Ubuntu 24 onward, the distribution MySQL packages are used.

The `cm-mysql-setup` plugin has been developed with `Slurm` integration (figure [7.12](/admin/workloadmanagement#7324-slurm-accounting-database-configuration)) in mind, but it is usable with other applications too, with some manual configuration.

All the nodes referred to in this section must be UP at the time of the command line run, otherwise commands will fail.

#### 14.12.1.1  High availability Design

When high availability is needed, two nodes can be selected for deployment. The `cm-mysql-setup` utiility sets up a `ReplicaSet` with a single primary and a single replica. Replication between the primary and replica is asynchronous, for faster writes.

Replication uses GTID (Global Transaction ID) to achieve the best reliability possible. This setup installs `mysql-router` on the client nodes, to achieve transparency for the client daemon such as `slurmdbd`, when `MySQL server replication` is configured . This setup requires `mysql-shell` to be installed on the head node and on client nodes, when `MySQL server replication` is configured, and therefore `mysql-router` is also required.

If the chosen configuration is high availability, then in `/root/mysql-ha-config.conf` there is a configuration file containing all the passwords needed to set up the configuration. It is the root user’s responsibility to keep that configuration file safe from non-root-users.

### 14.12.2  Installation Through The Wizard

Running `cm-mysql-setup` brings up the TUI installation wizard for MySQL. Deployment of MySQL is done by the cluster administrator with the following steps:

1. First screen: If MySQL is already installed on the cluster, then the screen offers an uninstallation option.

![Base ViewMySQL Installation: first screen of the wizard](/base-command-manager/product-manuals/_fern-img/70a2be8bafdaf82006997355458266fa230bb9206f2a62ecc6b19ac0cc01c021.webp)

*Figure 14.6: Base ViewMySQL Installation: first screen of the wizard*

2. Setting a configuration overlay name for the MySQL overlay. The default value is usually fine.

![Base View MySQL Installation: MySQL overlay](/base-command-manager/product-manuals/_fern-img/af975bcaeceb8f9a45410dff077d58ef80c3ac3f3e1c84345a1868138950e9a3.webp)

*Figure 14.7: Base View MySQL Installation: MySQL overlay*

3. Selecting a category in which to install MySQL. Only categories with one or two nodes can be selected, and only one category can be selected.

![Base View MySQL Installation: Select category](/base-command-manager/product-manuals/_fern-img/9082fa724dc195dbd714689dd0e639a5b7e1f51fdeb503b079b4d8a3f35fb5c6.webp)

*Figure 14.8: Base View MySQL Installation: Select category*

4. If a category was not selected in the previous step, then one or two compute nodes can be selected now instead.

![Base View MySQL Installation: Select nodes](/base-command-manager/product-manuals/_fern-img/47771b05ae0bb32df513fd9ccec31e11545366db2be20634c76cfbbe7f630475.webp)

*Figure 14.9: Base View MySQL Installation: Select nodes*

5. If two nodes were selected in the previous step, a further screen appears to select which of the two nodes is the primary. The other node becomes the replica. Exactly one node must be selected; selecting none or both is rejected. This corresponds to the `--primary-node` option described in Section [14.12.3](#14123-installation-from-cli).

![Base View MySQL Installation: Select primary node](/base-command-manager/product-manuals/_fern-img/db0231d0a4bf3681be453fa424981bfb75c89c875ddc49069ebbe5169d28800b.webp)

*Figure 14.10: Base View MySQL Installation: Select primary node*

6. On Ubuntu24, MySQL binds only to `localhost`. Here the cluster administrator can choose whether to have it bind it to all interfaces. This is what is expected if applications such as `slurmdbd` are running on other hosts.

![Base View MySQL Installation: Bind all interfaces](/base-command-manager/product-manuals/_fern-img/7c6c7d427e2164513cb4655d8447c33229b6c7d088bb2df67a2fc38341a572e8.webp)

*Figure 14.11: Base View MySQL Installation: Bind all interfaces*

7. If this is a reinstallation with an existing data directory, the old root password is needed to configure the system, and will be changed later. If not reinstalling, the old root password is left empty.

![Base View MySQL Installation: give old root password](/base-command-manager/product-manuals/_fern-img/2841e0bc1551c049c4edc04099d39b8a96a255b79420b912fd8535c67b714d93.webp)

*Figure 14.12: Base View MySQL Installation: give old root password*

8. The new root password for MySQL can be set.

![Base View MySQL Installation: set new root password](/base-command-manager/product-manuals/_fern-img/f975d560875c2a7fe1b98fa347b250d544b0ab41c9073355580af012d3852a8e.webp)

*Figure 14.13: Base View MySQL Installation: set new root password*

9. After these steps, the configuration can be:

   * saved and installed right away with the `Save config & deploy` option

   * saved without installing right away, and the installation carried out with that configuration later, using various other options available in the TUI

In the final summary screen, as with other scripts that come with the `cm-setup` package, the configuration setting can be one of the following kinds:

* `minimal config`: For this minimal kind of configuration setting, the configuration consists only of the settings that differ from the default application configuration. The remaining default application configuration settings are not included in the configuration.

* `config`: For this non-minimal kind of configuration setting, the configuration consists of the minimal configuration settings (the ones changed by BCM), as well as the remaining default configuration settings (the ones provided with the application). That is to say: the remaining default configuration application settings are included in the configuration. The default application configuration settings may change as the upstream packages change.

### 14.12.3  Installation From CLI

This command line format that is used to install `MySQL` on one or two cluster nodes is:

```bash
[root@basecm11 ~]# cm-mysql-setup --setup --nodes=node001,node002 --root-password='YourSecureP@ss1'
[--overlay-name=cm-mysql] [--category=db-category] [--primary-node=node001] [--skip-packages]
```

* `--nodes` and `--category` are mutually exclusive

* `--nodes` takes two existing hostnames at the most

* The category selected with `--category` must exist and must have either one or two nodes in it.

* The option `--primary-node` is compulsory if `MySQL` is to be installed on two nodes.

* The password in option `--root-password` sets the root password for the new MySQL configuration. It must be at least 8 characters long, with at least: one uppercase letter, one lowercase letter, one number, and one special character.

* `--skip-packages` skips the installation of the packages and the repository. The packages must always be present on the target machines.

#### 14.12.3.1  Installation in an Air-Gapped Environment

In an air-gapped environment, the installation process is slightly different, and differs slightly for each distribution.

For Ubuntu 22.04, SLES and RHEL, the `MySQL Community Edition` packages are needed, while For Ubuntu 26.04 and Ubuntu 24.04, the distribution `MySQL` packages are used.

After that, in every case, you need to use the option `--skip-packages` to skip the installation of the packages and the repository package. All cm-mysql-setup commands are still valid with that addition.

It is important to note that you have to install the packages in specific software images.

* mysql-server packages are needed in server nodes’ software image.

* mysql-router packages are needed in client nodes’ software image, to run the helper script from there to check the routers. They are not necessary if there is a single server node selected for installation of MySQL server.

* mysql-shell packages are needed in the head nodes’ software image. They are not necessary if mysql-router is not installed on the head node.

* mysql-shell packages are needed in the client nodes’ software images, when mysql-router is installed on them. They are not necessary if mysql-router is not installed on the client nodes.

Before actually starting the installation with the cm-mysql-setup utility, you need to run the following commands in `cmsh`:

```bash
    [root@basecm11 ~]# cmsh
[basecm11->root]% device
[basecm11->device]% foreach -n node001..node004 (imageupdate -w)
[basecm11->device]% exit
```

In the example, node001..node004 is a list of all nodes involved in the installation, which should be replaced with the actual list of nodes needing the packages to be installed.

**Ubuntu 24.04 and Ubuntu 26.04**

For Ubuntu 24.04 and Ubuntu 26.04, the distribution `MySQL` packages are used and of course they must be downloaded in advance, along with their dependencies.

You need to run the following commands to download the packages, in an online system:

```bash
[root@basecm11 ~]# apt-get download
    $(apt-cache depends --recurse -i mysql-server | grep '^\{}w' | sort -u)
[root@basecm11 ~]# apt-get download
    $(apt-cache depends --recurse -i mysql-router | grep '^\{}w' | sort -u)
[root@basecm11 ~]# apt-get download
$(apt-cache depends --recurse -i mysql-shell | grep '^\{}w' | sort -u)
```

After that you need to move them to the software image and installing the packages in a chroot environment.

```bash
[root@basecm11 ~]# mv *.deb /path/to/software/image/
[root@basecm11 ~]# cm-chroot-sw-img /path/to/software/image/
[root@basecm11 software/image]% dpkg -i *.deb
[root@basecm11 software/image]% exit
```

There are a few caveats:

* If you are getting errors about conflicting packages with mariadb-connector-c or other client packages, do not remove them, as they might be needed for `slurmdbd` package. Force the installation if necessary.

* The commands in the examples for Ubuntu 22.04 work also on Ubuntu 24.04 and Ubuntu 26.04, even though the package names are different.

**Ubuntu 22.04**

MySQL Server Community Edition packages are used and they must be downloaded in advance. You can download packages from [https://dev.mysql.com/downloads/repo/apt/](https://dev.mysql.com/downloads/repo/apt/). Version 8.0, 8.4 and 9.7 LTS are supported.

Otherwise, you can install in an online system the package configuring the MySQL Community Edition repository [https://dev.mysql.com/get/mysql-apt-config_0.8.34-1_all.deb](https://dev.mysql.com/get/mysql-apt-config_0.8.34-1_all.deb) as it is required in the online installation.

```bash
[root@basecm11 ~] # wget https://dev.mysql.com/get/mysql-apt-config_0.8.34-1_all.deb
[root@basecm11 ~] # dpkg -i mysql-apt-config_0.8.34-1_all.deb
[root@basecm11 ~] # apt-get update
[root@basecm11 ~] # apt install -d -o Dir::Cache::archives=/tmp/debs mysql-community-server
[root@basecm11 ~] # apt install -d -o Dir::Cache::archives=/tmp/debs mysql-router-community
[root@basecm11 ~] # apt install -d -o Dir::Cache::archives=/tmp/debs mysql-shell
```

The previous commands must be run in an online system. When installing the repository package, chose mysql-8.0, mysql-8.4-lts or mysql-9.7-lts. Keep Connectors enabled. The commands in example download packages in the /tmp/debs directory.

There are a few caveats:

* If you are getting errors about conflicting packages with mariadb-connector-c or other client packages, do not remove them, as they might be needed for `slurmdbd` package. Force the installation if necessary.

* Before installing the server packages, apply the package installation workarounds on Ubuntu described in paragraph [14.12.3.1](#subsubsectmysql-package-installation-workarounds).

* The commands in the examples for Ubuntu 24.04 and Ubuntu 26.04 work also on Ubuntu 22.04, even though the package names are different.

**RHEL**

MySQL Server Community Edition packages are used and they must be downloaded in advance. You can download the repository package from [https://dev.mysql.com/downloads/repo/yum/](https://dev.mysql.com/downloads/repo/yum/). After that you can install the package in an online system and download the packages with yum from there.

```bash
[root@basecm11 ~] # rpm -ivh mysql84-community-release-el9-4.noarch.rpm
[root@basecm11 ~] # yum module -y disable mysql
[root@basecm11 ~] # dnf download --resolve --destdir=/tmp/rpms mysql-community-server
[root@basecm11 ~] # dnf download --resolve --destdir=/tmp/rpms mysql-router-community
[root@basecm11 ~] # dnf download --resolve --destdir=/tmp/rpms mysql-shell
```

The previous commands must be run in an online system.

**SLES**

MySQL Server Community Edition packages are used and they must be downloaded in advance. You can download the repository package from [https://dev.mysql.com/downloads/repo/suse/](https://dev.mysql.com/downloads/repo/suse/). After that you can install the package in an online system and download the packages with zypper from there.

```bash
[root@basecm11 ~] # rpm -ivh mysql84-community-release-sl15-3.noarch.rpm
[root@basecm11 ~] # zypper --installroot /root/mysql-server \
  --pkg-cache-dir /tmp/rpms \
  in -d --no-recommends mysql-community-server
[root@basecm11 ~] # zypper --installroot /root/mysql-server \
  --pkg-cache-dir /tmp/rpms \
  in -d --no-recommends mysql-router-community
[root@basecm11 ~] # zypper --installroot /root/mysql-server \
--pkg-cache-dir /tmp/rpms \
in -d --no-recommends mysql-shell
```

In the previous examples, /root/mysql-server and /tmp/rpms should be already existing.

**Ubuntu Server Package Installation Workaround**

Before installing the server packages, you need to:

* Create `/etc/mysql/mysql.conf.d/temp_skip_networking.cnf` in the image.

* Add the following content to the file:

  ```bash
  [mysqld]
  skip-networking=1
  ```

* Install the server packages.

* Remove the file `/etc/mysql/mysql.conf.d/temp_skip_networking.cnf` from the image. Failure to do so will cause the installation to fail.

### 14.12.4  Removal From CLI

```bash
[root@basecm11 ~]# cm-mysql-setup --disable --overlay-name=cm-mysql --yes-i-really-mean-it
```

`--overlay-name` must be an existing overlay. This command does not uninstall packages and it does not remove data from the disk. Afterwards, a new configuration can be resumed on the same nodes, with the same root password and the same data, running the same configuration. If the new configuration is different, errors might occur and manual recovery might be necessary.

### 14.12.5  Clean Up

```bash
[root@basecm11 ~]# cm-mysql-setup --cleanup --nodes=node001,node002 --yes-i-really-mean-it [--keep-helper-config]
```

The purpose of the `--cleanup` option is to allow MySQL to be reinstalled when the existing data is not wanted, or when the old root password is not available. As described in Section [14.12.2](#14122-installation-through-the-wizard), the old root password is needed when a reinstallation is carried out over an existing data directory. If the data directory is removed first, then the reinstallation is started from scratch, and the old root password is no longer needed.

This command is used to remove the MySQL data from the node disks. No overlay must exist on the nodes for `MySQL` before running the command. This command cannot be undone and it is destructive. It should not be used on head nodes, and elsewhere should be used only when the existing data is genuinely no longer needed. The `--keep-helper-config` option is added if the helper configuration file is to be kept across the installations. *Important:* If the plan is to reinstall, then either all nodes should be cleaned, or all nodes should be kept unchanged. A mixed state, where some nodes contain existing data and others do not, can cause unexpected issues and potential data loss.

### 14.12.6  Maintenance

A helper script, `cm-slurm-mysql-ha`, is installed under `/cm/shared/apps/cm-slurm-mysql-ha/bin/` by `cm-mysql-setup` when two nodes are used for MySQL.

Its help text can be viewed with the `-h|--help` option. The usage is:

```bash
usage: cm-slurm-mysql-ha [-h] [--config CONFIG] [--no-save] [--generate-passwords]
                         [--generated-password-length N] [-v]
                         {setup-admin-user,setup-replicaset,setup-router,status,failover,
                         remediate,migrate-to-gtid,migrate-from-mariadb}
                         ...
```

The `cm-slurm-mysql-ha` utility uses the helper configuration file in `/root/mysql-ha-config.conf`

#### 14.12.6.1  Failover

Manual intervention is necessary for failover, and the helper script can then be used, as in the following example:

```bash
cm-slurm-mysql-ha --config /root/mysql-ha-config.conf failover --host node001
```

The `--host` argument is set by the administrator to point to the node to connect to, i.e., the current primary node. It automatically selects the other MySQL node (the current replica) as the next primary.

If the primary node has crashed, then it is possible to connect to the secondary node instead, but in that case the parameter `--force` must be used.

#### 14.12.6.2  Remediation

Remediation is the operation needed to re-synchronize a replica server (secondary) with the primary after the replica has been offline or has fallen out of sync. It removes the replica from the ReplicaSet, clones the current data from the primary onto the replica, and then rejoins the replica to the ReplicaSet. The command must be run from the head node:

```bash
cm-slurm-mysql-ha --config /root/mysql-ha-config.conf remediate --host primary --target secondary
```

where `--host` is the current primary node and `--target` is the replica node to be re-synchronized. Remediation is non-destructive to the primary’s data, but replaces all data on the target node with a fresh clone from the primary.

#### 14.12.6.3  Post-Failover Recovery

After a forced failover (section [14.12.6.1](#141261-failover)) in which the old primary has crashed and the replica has been promoted to primary, the old primary node must be re-integrated when it comes back online. At that point the old primary is out of sync and must be remediated as a replica of the new primary. The steps to be taken are:

1. Confirming that the new primary is healthy and that the old primary node is back online and reachable.

2. Running remediation, specifying the new primary as `--host` and the recovered node as `--target`:

   ```bash
   cm-slurm-mysql-ha --config /root/mysql-ha-config.conf remediate --host node002 --target node001
   ```

   where `node002` is the new primary (promoted during failover) and `node001` is the recovered former primary, now rejoining as replica.

3. Verifying the ReplicaSet status:

   ```bash
   cm-slurm-mysql-ha --config /root/mysql-ha-config.conf status
   ```

   Both nodes should show as members of the ReplicaSet, with `node002` as primary and `node001` as replica.

The administrator may then optionally fail back to the original primary if the original node assignment is preferred, by running a normal (non-forced) failover:

```bash
cm-slurm-mysql-ha --config /root/mysql-ha-config.conf failover --host node002
```

#### 14.12.6.4  Disk Failure Recovery

The recovery procedure depends on which node’s disk has failed.

**Disk failure on the replica (secondary):**

The primary continues serving normally. When the replica’s disk is repaired or the node is rebuilt remediation is run to re-sync the replica from the primary:

```bash
cm-slurm-mysql-ha --config /root/mysql-ha-config.conf remediate --host node001 --target node002
```

**Disk failure on the primary:**

This is equivalent to a primary crash. This should require the forced failover and post-failover recovery procedure:

1. The replica is promoted to primary with a forced failover (section [14.12.6.1](#141261-failover)):

   ```bash
   cm-slurm-mysql-ha --config /root/mysql-ha-config.conf failover --host node002 --force
   ```

   Any transactions that were not yet replicated to the replica at the time of the crash will be lost, since replication is asynchronous.

2. The failed primary node drive must then be repaired or rebuilt

3. MySQL is reinstalled on the repaired node.

4. The repaired node is re-integrated as a replica using remediation, as described in Post-Failover Recovery section [14.12.6.3](#141263-post-failover-recovery).

#### 14.12.6.5  Split Brain

A split brain situation arises when both nodes lose connectivity to each other but both remain running and potentially serving clients independently. In a two-node MySQL ReplicaSet, this can occur if the network link between the nodes is interrupted while both nodes are healthy.

**Detection:**

A split brain can be suspected when:

* Both nodes are reachable from the head node but cannot reach each other.

* The ReplicaSet status reports an error on one or both members.

* Applications report inconsistent query results or connection errors.

The ReplicaSet status should be checked from the head node:

```bash
cm-slurm-mysql-ha --config /root/mysql-ha-config.conf status
```

**Resolution:**

The goal is to designate one node as the authoritative primary and discard any divergent writes on the other. Because replication is asynchronous, writes that reached only one node during the split cannot be automatically reconciled, which means that manual intervention is needed. Steps in the intervention are:

1. Deciding which node’s data is authoritative. Normally this is the node that was the primary before the split.

2. Stopping MySQL on the node whose data is to be discarded, to prevent further writes.

3. Restoring network connectivity between the nodes.

4. Running remediation to re-clone the authoritative node’s data onto the discarded node:

   ```bash
   cm-slurm-mysql-ha --config /root/mysql-ha-config.conf remediate --host node001 --target node002
   ```

5. Restartin MySQL on the remediated node and verifying ReplicaSet status.

Any writes that occurred on the discarded node during the split are permanently lost. If those writes must be recovered, a manual data reconciliation using MySQL binary logs is required before running remediation. The MySQL documentation can be consulted for this procedure.

#### 14.12.6.6  Adding Custom Applications To A Compute Node

If adding a custom application to a compute node, then `mysql-router` must be set up on the node where the application is to run. `mysql-router` can be set up with:

```bash
cm-slurm-mysql-ha --config /root/mysql-ha-config.conf setup-router
```

The configuration file will have to be copied manually to the target node, and back, to keep the configuration synchronized between all applications.

#### 14.12.6.7  Backup