# NetQ 5.0 Settings For NVLink Monitoring

NetQ is a scalable network monitoring and management tool for NVLink, Ethernet, or both. It can work with NVLink fabrics and Cumulus Linux switches. NetQ version 5.0 is unified with NMX-Manager, and uses NMX-Manager capabilities if used in NVLink mode.

## 2.1  NMX Settings For NVLink Monitoring

NMX is a product suite for HPC cluster network monitoring and management. The system is made up of:

* NMX Telemetry

* NMX Manager

* NMX Controller

* NMX Oasis

The NVIDIA Mission Control edition of BCM can monitor NMX telemetry services that run on:

* NVLinks (direct GPU interconnection within a server)

* NVLink switches (direct GPU interconnection across servers)

## 2.2  Installing NetQ 5.0 Using The Mission Control Wizard

### 2.2.1  Permanent License Generation And Application Guide

When installing NetQ, the system receives an evaluation license valid for 60 days. When the evaluation license expires, REST API access is blocked until a new license is applied.

#### 2.2.1.1  Generating a License File

Before generating the license file, the following must be prepared:

* A list of servers with the MAC address of each server on which the NetQ software is to be installed

* Access to the NVIDIA Licensing Portal (NLP) with valid credentials

The following steps generate the license file:

* The NLP is accessed, and logged into with the prepared credentials.

* The `Network Entitlements` tab is clicked. This displays a list of the serial licenses of all software products. For each software product, some license information details are shown, including the license status.

* The license can be selected from the list, and activated by clicking on the `Actions` button.

* The MAC addresses are configured.

  * In the MAC Address field, the MAC address of the delegated license-registered host is added.

  * If applicable, in the HA MAC Address field, the High Availability (HA) server MAC address is added.

  * **Note**: If there is more than one NIC installed on a UFM Server, then any of the MAC addresses can be used.

* The license is then generated and downloaded:

  * Clicking on `Generate License File` creates the license key file for the software.

  * Clicking on `Download License File` allows the license file to be saved on to a local computer.

#### 2.2.1.2  License Regeneration Notes

If the cluster administrator regenerates a license, then the following must be considered:

* If the NIC or server is replaced, then the steps to generate license file must be repeated for the new MAC address.

* Regeneration of the license can only be carried out two times. For further regeneration, support should be contacted at [enterprisesupport@nvidia.com](mailto:enterprisesupport@nvidia.com).

### 2.2.2  Downloading The NetQ Installation Package

The NetQ installation package can be downloaded from the NVIDIA Licensing Portal (NLP).

#### 2.2.2.1  Downloading NetQ

The following steps allow the package to be downloaded:

1. The NLP is accessed, and logged into with the prepared credentials.

2. `Software Downloads` is clicked, the product family is filtered to NetQ, the relevant version is found, and the “Appliance” platform package is downloaded.

3. `Download` is clicked.

4. The file is saved to the local drive.

5. `Close` is clicked.

The `.tar.gz` file is copied over to the BCM head node using `scp` or `rsync`.

The Debian packages can be downloaded from:

[https://download.nvidia.com/cumulus/apps3.cumulusnetworks.com/repos/deb/pool/netq-5.0/](https://download.nvidia.com/cumulus/apps3.cumulusnetworks.com/repos/deb/pool/netq-5.0/)

The relevant apps and agents package for `ubuntu24` and the relevant CPU architecture (`arm` or `amd`) should be searched for. These three files are required:

1. The NetQ tarball

2. The `netq-agent` .deb package

3. The `netq-apps` .deb package

#### 2.2.2.2  Installation

Running `cm-mission-control-setup` brings up the TUI installation wizard for NetQ. Deployment of NetQ is done by the cluster administrator with the following steps:

1. The NetQ installation is selected (figure [2.1](#fig-nvidia-mission-control-netq-deployment-install)):

![NetQ deployment: NetQ installation selection](/base-command-manager/product-manuals/_fern-img/8462086a698e0f590450a21485d8fa433a064a7bf7e1352842b91c5e1ea3403d.webp)

*Figure 2.1: NetQ deployment: NetQ installation selection*

2. The Kubernetes cluster where NetQ is to be installed is chosen (figure [2.2](#fig-nvidia-mission-control-netq-deployment-choose-cluster)):

![NetQ deployment: choosing a Kubernetes cluster](/base-command-manager/product-manuals/_fern-img/35a5d547f3177dcae71c28d65427c7c8c6fd5e502ebdfddf685e9b05aa7f20b5.webp)

*Figure 2.2: NetQ deployment: choosing a Kubernetes cluster*

3. The node category for the nodes where NetQ is to be installed is chosen (figure [2.3](#fig-nvidia-mission-control-netq-deployment-choose-category)):

![NetQ deployment: choosing a node category](/base-command-manager/product-manuals/_fern-img/a453aecbc8b304137a2ed33415c3d5a5300b1001fe221f2d0cf0277a84564362.webp)

*Figure 2.3: NetQ deployment: choosing a node category*

4. If no category is set, then 3 nodes can be chosen (figure [2.4](#fig-nvidia-mission-control-netq-deployment-choose-nodes)):

![NetQ deployment: choosing 3 nodes](/base-command-manager/product-manuals/_fern-img/a60613808c191fc50e771fcdbf24cc14c031ac95da648ab990c122a7d5d8dc95.webp)

*Figure 2.4: NetQ deployment: choosing 3 nodes*

5. The NetQ overlay name and priority are set. In most cases, there is no need to change the suggested values (figure [2.5](#fig-nvidia-mission-control-netq-deployment-choose-overlay)):

![NetQ deployment: choosing an overlay](/base-command-manager/product-manuals/_fern-img/acd48f748bed029fedc55452ada4f268033f8ebe37bd29f0bcbf491ea63c4003.webp)

*Figure 2.5: NetQ deployment: choosing an overlay*

6. A virtual IP address is set for NetQ access (figure [2.6](#fig-nvidia-mission-control-netq-deployment-choose-virtual-ip)):

![NetQ deployment: setting a virtual IP address](/base-command-manager/product-manuals/_fern-img/b4caae7e9ae37535ad41ce64bbab54a2cda03154aad18fed2f2ae2c9ba617bf3.webp)

*Figure 2.6: NetQ deployment: setting a virtual IP address*

7. The paths to the NetQ tarball and Debian packages are set (figure [2.7](#fig-nvidia-mission-control-netq-deployment-choose-file-paths)):

![NetQ deployment: setting paths to the installation packages](/base-command-manager/product-manuals/_fern-img/3a832ac5361d2e3b34fa5192e058b7e717c0170be5cfcc968dc89b4a72393e3f.webp)

*Figure 2.7: NetQ deployment: setting paths to the installation packages*

8. The NetQ deployment mode is set (figure [2.8](#fig-nvidia-mission-control-netq-deployment-choose-mode)):

![NetQ deployment: setting the NetQ deployment mode](/base-command-manager/product-manuals/_fern-img/f4a87cbe8beab0244ff8e896c51bc1f473bdd873d35d095b6779136d75d5e49d.webp)

*Figure 2.8: NetQ deployment: setting the NetQ deployment mode*

9. The Kong (NMX API) read/write password is set, if `NVL Mode` has been chosen (figure [2.9](#fig-nvidia-mission-control-netq-deployment-choose-kong-rw-passwd)):

![NetQ deployment: setting the read/write password](/base-command-manager/product-manuals/_fern-img/c28fb8949609be54b2e9d96c7cca347dbbdbe307b70353307c02c0bbe6317a03.webp)

*Figure 2.9: NetQ deployment: setting the read/write password*

10. The Kong (NMX API) read-only password is set, if `NVL Mode` has been chosen (figure [2.10](#fig-nvidia-mission-control-netq-deployment-choose-kong-passwd)):

![NetQ deployment: setting the read-only password](/base-command-manager/product-manuals/_fern-img/89f62098133f8438b4ab8c3a1977dda3b6e1e73df0a8cfc604f60f89a55884c1.webp)

*Figure 2.10: NetQ deployment: setting the read-only password*

11. The storage path for Longhorn (a replicated block storage system for Kubernetes) is set (figure [2.11](#fig-nvidia-mission-control-netq-deployment-choose-storage-path)):

![NetQ deployment: setting the storage path for Longhorn](/base-command-manager/product-manuals/_fern-img/ba980bbd5bede1f4845cce2aafa5e170cbdf8b157dc08ccd164880282ae06ea2.webp)

*Figure 2.11: NetQ deployment: setting the storage path for Longhorn*

12. The configuration is saved and deployed (figure [2.12](#fig-nvidia-mission-control-netq-deployment-save-deploy)):

![NetQ deployment: saving and deploying the configuration](/base-command-manager/product-manuals/_fern-img/afe67e1741eceba686385a8760c8f69297d403ca54c030d9c9a732428f5d753f.webp)

*Figure 2.12: NetQ deployment: saving and deploying the configuration*

Notes:

* Three nodes must be selected for NetQ deployment.

* If the selected nodes do not meet the necessary hardware requirement, then a warning is displayed.

* Kong passwords must be at least 8 characters long.

#### 2.2.2.3  Post Installation Validation

The pods can be examined to validate NetQ:

kubectl get pods -A

All pods should be in a `Running` or `Complete` state.

A connection can be made using the virtual IP address and a URL in the form:

`https://<Virtual IP>/nmx/swag/index.html`

To log in, the user name is `rw-user` for read/write access, or `ro-user` for read-only access. The password is the password that was set during the installation.

#### 2.2.2.4  Uninstall NetQ

A NetQ installation can be uninstalled by running `cm-mission-control-setup` and selecting `NVIDIA Mission Control NetQ uninstallation` (figure [2.13](#fig-nvidia-mission-control-netq-deployment-uninstall)):

![NetQ uninstallation: selecting the uninstallation](/base-command-manager/product-manuals/_fern-img/79e6e0abf12259932a72e1d2ee16212c32cdbdf1da15b8b4781357ffdf47935b.webp)

*Figure 2.13: NetQ uninstallation: selecting the uninstallation*

## 2.3  NMX Server Authentication Configuration In BCM

NMX service authentication settings can be configured from within `partition` mode, within the `nmxmsettings` submode:

```bash
[basecm11->partition[base]->nmxmsettings]% show
Parameter                        Value
-------------------------------- --------------------------------------------
Revision
Server                           10.140.0.41
User name                        rw-user
Password                         ********
Port                             443
Verify SSL                       no
CA certificate
Certificate
Private key
Prometheus metric forwarders     <0 in submode>
```

The corresponding Base View navigation path for this is using:

`Cluster > Settings > BMC Settings > NMX settings> +`

After BCM has provisioned the NMX Controller and the NMX Telemetry services on the NVSwitches, then the `sample_nmxm` data producer produces the NMX measurables. These can be viewed from `partition` mode:

**Example**

```bash
[basecm11->partition[base]]% latestmetricdata| head -2; latestmetricdata| grep nmx
Measurable                      Parameter       Type    Value  Age   State Info
------------------------------- --------------  ------- ------ ----- ----- -----
nmxm_chassis_count                              NMX-M   9      30.9s
nmxm_compute_allocation_count   all             NMX-M   54     30.9s
nmxm_compute_allocation_count   free            NMX-M   48     30.9s
nmxm_compute_allocation_count   full            NMX-M   6      30.9s
nmxm_compute_allocation_count   partial         NMX-M   0      30.9s
nmxm_compute_health_count       degraded        NMX-M   0      30.9s
nmxm_compute_health_count       healthy         NMX-M   0      30.9s
nmxm_compute_health_count       unhealthy       NMX-M   6      30.9s
nmxm_compute_health_count       unknown         NMX-M   63     30.9s
nmxm_compute_nodes_count                        NMX-M   69     30.9s
nmxm_domain_health_count        degraded        NMX-M   0      30.9s
nmxm_domain_health_count        healthy         NMX-M   0      30.9s
nmxm_domain_health_count        unhealthy       NMX-M   0      30.9s
nmxm_domain_health_count        unknown         NMX-M   3      30.9s
nmxm_gpu_health_count           degraded        NMX-M   0      30.9s
nmxm_gpu_health_count           degraded_bw     NMX-M   0      30.9s
nmxm_gpu_health_count           healthy         NMX-M   0      30.9s
nmxm_gpu_health_count           nonvlink        NMX-M   24     30.9s
nmxm_gpu_health_count           unknown         NMX-M   16     30.9s
nmxm_gpus_count                                 NMX-M   40     30.9s
nmxm_ports_count                                NMX-M   152    30.9s
nmxm_switch_health_count        healthy         NMX-M   0      30.9s
nmxm_switch_health_count        missing_nvlink  NMX-M   8      30.9s
nmxm_switch_health_count        unhealthy       NMX-M   0      30.9s
nmxm_switch_health_count        unknown         NMX-M   0      0.9s
nmxm_switch_nodes_count                         NMX-M   46     30.9s
```

### 2.3.1  NMX Manager Metrics Forwarding Via BCM And `prometheusmetricforwarders`

Prometheus servers can be used to pick up NMX Manager metrics via Prometheus exporters. However in a typical BCM configuration, such as in a BCM type 1 network ([section 3.3.9 of the *Installation Manual*](/installation/installing#339-network-topology)), the Prometheus exporter is behind the BCM head node firewall. This means that by default an external Prometheus server cannot reach the exporter endpoint.

In such a case the `prometheusmetricforwarders` submode can be used to define the endpoint URL and HTTP method that the exporter uses. This forwards the exporter endpoint to the external network interface of the head node. The external Prometheus server can then reach the forwarded exporter endpoint.

**Example**

```bash
[basecm11->partition[base]->nmxmsettings->prometheusmetricforwarders[all]]% show
Parameter                        Value
-------------------------------- ------------------------------------------------
Name                             all
Revision
Urls                             http://10.140.0.41:9091/metrics
Method                           GET
```

The corresponding Base View navigation path for configuring Prometheus metrics forwarding is using:

<code>
  Cluster > Settings > BMC Settings > NMX settings > 

   \> Prometheus metric forwarders > 
</code>