# RDMA / InfiniBand on AKS

# RDMA / InfiniBand on AKS

This guide covers setting up RDMA over InfiniBand on AKS for high-performance disaggregated inference with Dynamo. RDMA enables direct memory access between GPUs across nodes, bypassing CPU and kernel overhead — critical for low-latency KV cache transfer between prefill and decode workers.

Without RDMA, disaggregated inference falls back to TCP with severe performance degradation (~98s TTFT vs ~200-500ms with RDMA). See the [Disaggregated Communication Guide](/dynamo/dev/kubernetes-deployment/deployment-guide/disagg-communication) for details on transport options and performance expectations.

<Note>
The Network Operator and NicClusterPolicy steps in this guide are based on the [Azure AKS RDMA InfiniBand](https://github.com/Azure/aks-rdma-infiniband) repository. That project is open-source and not covered by Microsoft Azure support — file issues on the GitHub repository.
</Note>

## Prerequisites

**AKS cluster with RDMA-capable nodes:**

- At least **2 GPU nodes** to enable cross-node RDMA communication
- **ND-series VMs** with Mellanox ConnectX InfiniBand NICs (e.g., `Standard_ND96asr_v4`, `Standard_ND96isr_H100_v5`)
- **Ubuntu OS** on the node pool (required for NVIDIA driver compatibility)
- GPU driver installation **skipped** on the node pool (`--skip-gpu-driver-install`) — see [GPU Node Pool Setup](/dynamo/dev/kubernetes-deployment/cloud-provider-guides/azure/aks-setup#step-2-add-a-gpu-node-pool)

**Register the AKS InfiniBand feature** to ensure nodes land on the same physical InfiniBand network:

```bash
az feature register --namespace Microsoft.ContainerService --name AKSInfinibandSupport
az feature show --namespace Microsoft.ContainerService --name AKSInfinibandSupport --query "properties.state"
# Wait until "Registered"

az provider register --namespace Microsoft.ContainerService
```

## Overview

The RDMA setup involves five components installed in this order:

1. **Network Operator** — Deploys the Mellanox OFED driver and Node Feature Discovery
2. **NicClusterPolicy** — Configures the OFED driver on InfiniBand-capable nodes
3. **IB Node Configuration** — Loads InfiniBand kernel modules and sets memlock limits
4. **RDMA Shared Device Plugin** — Exposes InfiniBand NICs to pods as a Kubernetes resource
5. **GPU Operator** — Installed with RDMA-specific settings (NFD disabled, GPUDirect RDMA enabled, host MOFED)

## Step 1: Install the NVIDIA Network Operator

The [NVIDIA Network Operator](https://docs.nvidia.com/networking/display/cokan10/network+operator) automates deployment of networking components including Mellanox OFED drivers for InfiniBand support.

Create the namespace and label it for privileged workloads:

```bash
kubectl create ns network-operator
kubectl label --overwrite ns network-operator pod-security.kubernetes.io/enforce=privileged
```

Add the NVIDIA Helm repo (if not already added):

```bash
helm repo add nvidia https://helm.ngc.nvidia.com/nvidia
helm repo update
```

Create a `network-operator-values.yaml`:

```yaml
nfd:
  deployNodeFeatureRules: false
```

Install the Network Operator:

```bash
helm install network-operator nvidia/network-operator \
  --namespace network-operator \
  -f network-operator-values.yaml \
  --version v26.1.0
```

Verify the Network Operator pod is running:

```bash
kubectl get pods -n network-operator
```

## Step 2: Apply the NicClusterPolicy

The NicClusterPolicy configures the OFED driver (Mellanox OFED / DOCA driver) as a DaemonSet on all InfiniBand-capable nodes.

Apply the base NicClusterPolicy using kustomize:

```bash
kubectl apply -k https://github.com/Azure/aks-rdma-infiniband/configs/nicclusterpolicy/base
```

This targets nodes with Mellanox NICs (`feature.node.kubernetes.io/pci-15b3.present`) and installs the DOCA/OFED driver as a DaemonSet.

Wait for the MOFED driver DaemonSet to finish installing on all nodes (this may take several minutes):

```bash
kubectl get pods -n network-operator -l app=mofed-ubuntu22.04-ds -w
# Wait until all pods show Running
```

## Step 3: Deploy the IB Node Configuration DaemonSet

This DaemonSet loads InfiniBand kernel modules and sets unlimited memlock limits on GPU nodes. This is required for RDMA to function — without it, InfiniBand device files may not exist and memory pinning for RDMA transfers will fail.

<Info>
This step is not covered in the Azure RDMA repo but is required for a working setup. The DaemonSet loads `ib_umad` and `rdma_ucm` kernel modules, sets unlimited memlock limits for containerd and kubelet, and restarts both services to apply the changes.
</Info>

Create `ib-node-config.yaml`:

```yaml
apiVersion: apps/v1
kind: DaemonSet
metadata:
  name: ib-node-config
  namespace: kube-system
spec:
  selector:
    matchLabels:
      app: ib-node-config
  template:
    metadata:
      labels:
        app: ib-node-config
    spec:
      hostPID: true
      nodeSelector:
        kubernetes.azure.com/agentpool: <GPU_NODE_POOL_NAME>
      tolerations:
      - operator: Exists
      initContainers:
      - name: ib-setup
        image: busybox:1.36
        securityContext:
          privileged: true
        command:
        - sh
        - -c
        - |
          echo "=== IB Node Configuration ==="

          nsenter -t 1 -m -u -i -n -- modprobe ib_umad
          nsenter -t 1 -m -u -i -n -- modprobe rdma_ucm 2>/dev/null || true
          nsenter -t 1 -m -u -i -n -- modprobe ib_ucm 2>/dev/null || true
          nsenter -t 1 -m -u -i -n -- lsmod | grep ib_umad && echo "OK: ib_umad" || echo "FAIL: ib_umad"
          nsenter -t 1 -m -u -i -n -- ls /dev/infiniband/rdma_cm && echo "OK: rdma_cm device" || echo "WARN: no rdma_cm device"

          nsenter -t 1 -m -u -i -n -- sh -c 'printf "ib_umad\nrdma_ucm\n" > /etc/modules-load.d/ib-umad.conf'
          nsenter -t 1 -m -u -i -n -- sh -c 'printf "* - memlock unlimited\nroot - memlock unlimited\n" > /etc/security/limits.d/99-ib-memlock.conf'

          nsenter -t 1 -m -u -i -n -- sh -c 'mkdir -p /etc/systemd/system/containerd.service.d && printf "[Service]\nLimitMEMLOCK=infinity\n" > /etc/systemd/system/containerd.service.d/memlock.conf'
          nsenter -t 1 -m -u -i -n -- sh -c 'mkdir -p /etc/systemd/system/kubelet.service.d && printf "[Service]\nLimitMEMLOCK=infinity\n" > /etc/systemd/system/kubelet.service.d/memlock.conf'

          nsenter -t 1 -m -u -i -n -- systemctl daemon-reload
          nsenter -t 1 -m -u -i -n -- systemctl restart containerd
          nsenter -t 1 -m -u -i -n -- systemctl restart kubelet

          sleep 10

          nsenter -t 1 -m -u -i -n -- systemctl is-active containerd && echo "OK: containerd active" || echo "FAIL: containerd"
          nsenter -t 1 -m -u -i -n -- systemctl is-active kubelet && echo "OK: kubelet active" || echo "FAIL: kubelet"

          echo "=== Setup Complete ==="
      containers:
      - name: keepalive
        image: busybox:1.36
        command: ["sh", "-c", "echo IB node config active; sleep infinity"]
```

<Note>Replace `<GPU_NODE_POOL_NAME>` with your GPU node pool name (e.g., `ndh100pool`).</Note>

```bash
kubectl apply -f ib-node-config.yaml
```

Wait for all pods to complete initialization:

```bash
kubectl get pods -n kube-system -l app=ib-node-config -w
```

**What this does:**
- **`ib_umad`** — InfiniBand user-space management datagram module, required for RDMA device access
- **`rdma_ucm`** — RDMA user-space connection manager
- **Memlock limits** — RDMA requires pinning memory pages; without unlimited memlock, large transfers fail
- **Service restarts** — containerd and kubelet must be restarted to pick up the new memlock limits

## Step 4: Deploy the RDMA Shared Device Plugin

The RDMA Shared Device Plugin exposes InfiniBand NICs as a Kubernetes extended resource so pods can request RDMA access.

Create the ConfigMap with the device plugin configuration:

```yaml
apiVersion: v1
kind: ConfigMap
metadata:
  name: rdma-devices
  namespace: kube-system
data:
  config.json: |
    {
        "periodicUpdateInterval": 300,
        "configList": [{
             "resourceName": "hca_shared_devices_a",
             "rdmaHcaMax": 1000,
             "selectors": {
               "vendors": ["15b3"],
               "drivers": ["mlx5_core"]
             }
           }
        ]
    }
```

Create the DaemonSet:

```yaml
apiVersion: apps/v1
kind: DaemonSet
metadata:
  name: rdma-shared-dp-ds
  namespace: kube-system
spec:
  selector:
    matchLabels:
      name: rdma-shared-dp-ds
  template:
    metadata:
      labels:
        name: rdma-shared-dp-ds
    spec:
      hostNetwork: true
      nodeSelector:
        kubernetes.azure.com/agentpool: <GPU_NODE_POOL_NAME>
      tolerations:
      - operator: Exists
      containers:
      - name: k8s-rdma-shared-dp-ds
        image: ghcr.io/mellanox/k8s-rdma-shared-dev-plugin:v1.5.3
        securityContext:
          privileged: true
        volumeMounts:
        - name: device-plugin
          mountPath: /var/lib/kubelet/device-plugins
        - name: plugins-registry
          mountPath: /var/lib/kubelet/plugins_registry
        - name: config
          mountPath: /k8s-rdma-shared-dev-plugin
        - name: devs
          mountPath: /dev/
      volumes:
      - name: device-plugin
        hostPath:
          path: /var/lib/kubelet/device-plugins
      - name: plugins-registry
        hostPath:
          path: /var/lib/kubelet/plugins_registry
      - name: config
        configMap:
          name: rdma-devices
      - name: devs
        hostPath:
          path: /dev/
```

<Note>Replace `<GPU_NODE_POOL_NAME>` with your GPU node pool name (e.g., `ndh100pool`).</Note>

```bash
kubectl apply -f rdma-configmap.yaml
kubectl apply -f rdma-shared-dp-ds.yaml
```

Wait for the device plugin pods to start:

```bash
kubectl get pods -n kube-system -l name=rdma-shared-dp-ds -w
```

## Step 5: Install the GPU Operator (RDMA-Enabled)

Install the GPU Operator with RDMA-specific values:

```bash
helm install gpu-operator nvidia/gpu-operator \
  --namespace gpu-operator --create-namespace \
  --set nfd.enabled=false \
  --set driver.rdma.enabled=true \
  --set driver.rdma.useHostMofed=true
```

Key differences from a standard GPU Operator install:

- `nfd.enabled=false` — Network Operator already deploys Node Feature Discovery; running two NFD instances causes conflicts
- `driver.rdma.enabled=true` — enables GPUDirect RDMA support; causes the driver daemonset to build and load `nvidia_peermem`
- `driver.rdma.useHostMofed=true` — tells the GPU Operator to use the MOFED driver installed by the Network Operator (Step 1) rather than its own; required when the Network Operator manages OFED

Wait for the GPU Operator pods to reach `Running` state:

```bash
kubectl get pods -n gpu-operator -w
```

## Verification

**1. Check that MOFED driver pods are running on all InfiniBand nodes:**

```bash
kubectl get pods -n network-operator -l app=mofed-ubuntu22.04-ds
```

**2. Check that IB node config pods completed initialization:**

```bash
kubectl get pods -n kube-system -l app=ib-node-config
```

**3. Check that the RDMA Shared Device Plugin is running:**

```bash
kubectl get pods -n kube-system -l name=rdma-shared-dp-ds
```

**4. Verify RDMA resources are available on GPU nodes:**

```bash
kubectl get nodes -o json | jq '.items[] | select(.status.allocatable["rdma/hca_shared_devices_a"] != null) | {name: .metadata.name, rdma: .status.allocatable["rdma/hca_shared_devices_a"], gpu: .status.allocatable["nvidia.com/gpu"]}'
```

Each InfiniBand-capable node should report `rdma/hca_shared_devices_a` resources (typically `1k` based on `rdmaHcaMax: 1000`).

**5. Check GPU Operator pods are healthy:**

```bash
kubectl get pods -n gpu-operator
```

## Pod Resource Requests

Dynamo pods that need RDMA access should request the `rdma/hca_shared_devices_a` resource. When using the Dynamo operator with DGDR, this is handled automatically for disaggregated deployments on RDMA-capable clusters.

For manual DGD specs, add the resource request to your container:

```yaml
resources:
  limits:
    nvidia.com/gpu: 8
    rdma/hca_shared_devices_a: 1
```

<Note>
**`IPC_LOCK` capability is not required** when this setup is followed. `IPC_LOCK` is historically needed for RDMA because `ibv_reg_mr` calls `mlock()` to pin memory pages — but `mlock()` only needs the capability if the memlock rlimit would otherwise block it. The `ib-node-config` DaemonSet (Step 3) sets `LimitMEMLOCK=infinity` on the kubelet and containerd systemd units, so all pods on GPU nodes inherit an unlimited memlock limit and RDMA memory pinning works without any capability in the pod spec.

If you see `ENOMEM` errors from `ibv_reg_mr` and `ib-node-config` is running, verify that containerd and kubelet were restarted after the limits were applied (check the init container logs). If `ib-node-config` is not deployed, add `IPC_LOCK` to your pod's `securityContext.capabilities.add`.
</Note>

## Troubleshooting

**MOFED pods stuck in `Init` or `CrashLoopBackOff`:**
- Verify nodes are Ubuntu OS: `kubectl get nodes -o custom-columns="NAME:.metadata.name,OS:.status.nodeInfo.osImage"`
- Check MOFED pod logs: `kubectl logs -n network-operator <mofed-pod> -c mofed-container`

**`rdma/hca_shared_devices_a` not showing on nodes:**
- Check the RDMA device plugin pods are running: `kubectl get pods -n kube-system -l name=rdma-shared-dp-ds`
- Check device plugin logs: `kubectl logs -n kube-system <rdma-shared-dp-pod>`
- Verify the `rdma-devices` ConfigMap exists: `kubectl get configmap rdma-devices -n kube-system`

**IB kernel modules not loading:**
- Check the ib-node-config init container logs: `kubectl logs -n kube-system <ib-node-config-pod> -c ib-setup`
- Verify the MOFED driver is installed first (Step 2 must complete before Step 3)

**Memlock errors during RDMA transfers (`ENOMEM` from `ibv_reg_mr`):**
- Verify the ib-node-config DaemonSet has run on all GPU nodes and init containers completed
- Check that containerd and kubelet were restarted: `kubectl logs -n kube-system <ib-node-config-pod> -c ib-setup`
- Confirm the limits took effect on the kubelet process:
  ```bash
  # On a GPU node (via kubectl debug or ssh)
  cat /proc/$(pgrep -x kubelet)/limits | grep -i memlock
  # Should show: Max locked memory  unlimited  unlimited
  ```
- If limits are not unlimited, the ib-node-config DaemonSet needs to be re-applied and services restarted

**GPUDirect RDMA not working — `nvidia_peermem` module missing:**

ND-series nodes (including ND H100 v5) do **not** ship `nvidia_peermem` in the host OS. This module is required for InfiniBand adapters to directly read/write GPU memory — without it, RDMA transfers fall back to staging through host memory.

Verify whether the module is loaded:

```bash
# Check on a GPU node via a privileged pod or node shell
lsmod | grep nvidia_peermem
# If empty, the module is not loaded

modinfo nvidia_peermem
# If "Module not found", it is also not present in the host's /lib/modules
```

With the GPU Operator managing drivers (`driver.rdma.enabled=true`), `nvidia_peermem` is built and loaded by the `nvidia-driver-daemonset` — it lives in the driver pod's `/lib/modules`, not the host's native kernel modules. Verify the driver daemonset is loading it:

```bash
kubectl exec -n gpu-operator $(kubectl get pod -n gpu-operator -l app=nvidia-driver-daemonset -o jsonpath='{.items[0].metadata.name}') -- lsmod | grep nvidia_peermem
```

If this returns empty, ensure `driver.rdma.enabled=true` and `driver.rdma.useHostMofed=true` are set in your GPU Operator Helm values (see [Step 5](#step-5-install-the-gpu-operator-rdma-enabled) above), then restart the driver daemonset:

```bash
kubectl rollout restart daemonset/nvidia-driver-daemonset -n gpu-operator
```

<Note>
The [nvidia-peermem-reloader](https://github.com/Azure/aks-rdma-infiniband/tree/main/configs/nvidia-peermem-reloader) DaemonSet from the Azure RDMA repo is designed for clusters using **AKS-managed GPU drivers** (without the GPU Operator). It simply runs `modprobe nvidia-peermem` — which will fail on ND H100 v5 nodes because the host OS doesn't include the module. When using the GPU Operator (recommended), the operator handles `nvidia_peermem` automatically via `driver.rdma.enabled=true`.
</Note>

## See Also

- [Azure AKS RDMA InfiniBand — GitHub](https://github.com/Azure/aks-rdma-infiniband)
- [Set up InfiniBand on Azure HPC VMs — Microsoft Learn](https://learn.microsoft.com/en-us/azure/virtual-machines/setup-infiniband)
- [Enable InfiniBand VM extension — Microsoft Learn](https://learn.microsoft.com/en-us/azure/virtual-machines/extensions/enable-infiniband)
- [NVIDIA Network Operator Documentation](https://docs.nvidia.com/networking/display/cokan10/network+operator)
- [Disaggregated Communication Guide](/dynamo/dev/kubernetes-deployment/deployment-guide/disagg-communication) — transport options, UCX configuration, performance expectations