Simulation bring up allows users to check the Holoscan Sensor Bridge IP instantiation
and port connections. Modifications listed below are needed to bring up the HSB IP in a
configured state to stream sensor data out of the Host TX interface.

1. Comment out `define ENUM_EEPROM` in "HOLOLINK\_def.svh" In hardware, when
   `ENUM_EEPROM` is defined, the Holoscan Sensor Bridge IP reads the external EEPROM via
   I2C to fetch the unique MAC address and enumeration data. But this will require a Bus
   Functional Model of the EEPROM in the simulation testbench. When `ENUM_EEPROM` is not
   defined, MAC Address and Board Serial Number can be passed to the HSB IP as input
   ports.

2. Initialize the HSB IP for dataplane streaming. In hardware, the software APIs
   configure the Holoscan Sensor Bridge IP for dataplane stream on Host TX interface. In
   simulation, users can use the "init\_reg" in "HOLOLINK\_def.svh" to configure the
   Holoscan Sensor Bridge IP out of reset.

Below is a list of registers that can be added to "init\_reg" to initialize ethernet port
0\. Once the Sensor RX AXI-S interface is driven with `HOST_MTU` bytes or more, the
Holoscan Sensor Bridge IP will drive the dataplane stream on the Host TX interface.

```none
    //Address       Data
    {32'h0200_0304, 32'h0000_000B}, // dp_pkt_0  , dp_pkt_len
    {32'h0200_0308, 32'h0000_12B7}, // dp_pkt_0  , dp_pkt_host_udp_port
    {32'h0200_030C, 32'h0000_0001}, // dp_pkt_0  , dp_pkt_vip_mask
    {32'h0000_1020, 32'h0000_600D}, // sif_0     , dp_pkt_mac_addr_lo
    {32'h0000_1024, 32'h0000_0000}, // sif_0     , dp_pkt_mac_addr_hi
    {32'h0000_1028, 32'h0000_BEEF}, // sif_0     , dp_pkt_ip_addr
    {32'h0000_102C, 32'h0000_3000}, // sif_0     , dp_pkt_fpga_udp_port
    {32'h0000_1000, 32'h0000_0000}, // sif_0     , Destination QP
    {32'h0000_1004, 32'h0000_F00D}, // sif_0     , Remote Key
    {32'h0000_1008, 32'h0000_0000}, // sif_0     , Buffer 0 Virtual Address
    {32'h0000_1018, 32'h0001_0000}, // sif_0     , Bytes per Window
    {32'h0000_101C, 32'h0000_0001}, // sif_0     , Buffer Enable
    {32'h0200_0108, 32'h0000_0064}, // eth_pkt_0 , Eth pkt data plane priority
```

Above example is for 1 data path, for additional data paths

1. Add offset "0x0001\_0000" to the dp\_pkt register addresses and add offset
   "0x0000\_0040" to the sif register addresses.
2. Instantiate 2nd or more data paths in Holoscan Sensor Bridge IP HIF TX/RX Interface
   ports.
3. Increase N\_INIT\_REG by number of registers added to initialize.