1 · An action sets a target angle
The policy outputs 14 values, one per servo. Each value is a joint-angle offset in radians added to the nominal pose. A new action arrives every 20 ms (50 Hz) and holds for four physics steps.
Click or tap a stage to read its explanation. With a stage focused, press Enter or Space to select it; Escape clears the explanation.
Select a step for its explanation.
The policy outputs 14 values, one per servo. Each value is a joint-angle offset in radians added to the nominal pose. A new action arrives every 20 ms (50 Hz) and holds for four physics steps.
The position controller compares the target with the measured joint angle. Its response is what the motor model receives, not the final joint torque.
The BAM (Better Actuator Models) model converts the controller response into motor behavior, including friction, electrical limits, battery voltage, and delayed commands.
The fit uses the m6 model, a 7.4 V nominal supply within a 6.5–8.2 V range, and a 3–6 physics-step command delay (15–30 ms).
The Newton solver advances motion and contact every 5 ms (200 Hz). The resulting joint angle is measured again, closing the loop back to the controller.