Network Breakdown IP Plan Subnetting Calculator#
Use this calculator to estimate subnet sizes for NVIDIA DGX SuperPOD IP plans. Select a System Type and Scalable Units value, then choose Calculate.
The calculator supports Vera Rubin NVL72, DGX Rubin NVL8, GB200, GB300, B200, and B300. A scalable unit (SU) is a group of systems whose size depends on the system type.
Vera Rubin Scale and BMC Assumptions#
For Vera Rubin NVL72 and DGX Rubin NVL8, you can select from 1 through 64 scalable units.
The calculator uses the following baseboard management controller (BMC) address counts:
Vera Rubin NVL72 uses one BMC management address per compute tray.
Vera Rubin NVL72 uses two management addresses per NVLink switch: BMC and OS eth0. Those addresses use
nvlinknet<s>, notcinbmcnet1.Vera Rubin NVL72 uses one management address per power shelf on
pdunet<s>.Vera Rubin NVL72 uses one BlueField BMC address per compute tray on
dgxbfbmcnet<s>in noDPU mode.DGX Rubin NVL8 uses one BMC management address per DGX Rubin NVL8 system.
DGX Rubin NVL8 includes built-in NVLink switches. The calculator does not allocate a separate NVLink Switch (NVLSW) network for NVL8.
Subnet Connection Guide#
TAN stands for tenant access network. TAN1 carries storage traffic over converged Ethernet and tenant or user access traffic. It also connects user-facing interfaces for control-plane services, such as Kubernetes, NVIDIA Run:ai, and Slurm. Keep the management interfaces for control-plane equipment, including Base Command Manager (BCM), Kubernetes administration nodes, and Slurm controllers, on the ADMIN networks.
Use the following mapping to connect each subnet to the intended devices and interfaces:
VRF |
Subnet |
Connected Devices and Interfaces |
Do Not Connect |
|---|---|---|---|
ADMIN |
|
BCM and cluster-management servers, Kubernetes administration nodes, Network File System (NFS) or storage-management servers, and infrastructure management interfaces such as M1, M2, or bonded management interfaces |
GPU data interfaces, chassis BMCs, or switch-management ports |
ADMIN |
|
BMCs for control-plane and infrastructure servers, HSS management, infrastructure BlueField BMC interfaces, data processing unit (DPU) operating-system management interfaces, and appliance management ports |
Compute-tray chassis BMCs unless the IP plan explicitly includes and counts them |
ADMIN |
|
Ethernet switch-management ports, leaf and spine management interfaces, top-of-rack (ToR) management ports, and out-of-band (OOB) management switches |
ConnectX-9 data-plane ports or production traffic |
ADMIN |
|
Compute interconnect network (CIN) switch ETH0 or MGMT ports and related fabric-management appliances |
NVLink switch BMC or OS eth0 ports. Those addresses use |
ADMIN |
|
Vera Rubin compute-tray chassis BMCs or DGX Rubin NVL8 chassis BMCs |
GPUs, ConnectX-9 data ports, host operating-system interfaces, or service virtual IP (VIP) addresses |
ADMIN |
|
NVLink switch BMC and OS eth0 (ComE) management ports for that scalable unit |
GPU NVLink data or CIN data-plane ports |
ADMIN |
|
Power shelf and PDU management interfaces for that scalable unit |
Compute-tray BMCs or Ethernet switch-management ports |
ADMIN |
|
Compute-tray BlueField BMC in noDPU mode. DPU mode uses two DPU-OOB addresses per tray. |
Chassis BMCs on |
TAN1 |
|
Kubernetes user services, NVIDIA Run:ai services, Slurm login nodes,
API endpoints, and user-facing service interfaces such as an M1 and M2
|
Chassis BMCs or fabric-management interfaces |
TAN1/EXIT |
|
Loopback addresses, service VIPs, load-balancer VIPs, DNS, NTP, monitoring, logging, and other shared infrastructure endpoints |
Bulk allocations for compute nodes |
TAN1/EXIT |
|
Point-to-point router, firewall, or external gateway interfaces |
Servers, BMCs, or large endpoint groups |
dgxbfbmcnet<s>, nvlinknet<s>, and pdunet<s> use IntraPod addressing
(default 100.64.0.0/10). They do not come from the customer ADMIN root.
Vera Rubin Connection and Counting Guidance#
Use the following counting rules to confirm that the selected subnet contains enough usable addresses:
Subnet |
Vera Rubin Devices |
Counting Rule |
|---|---|---|
|
Cluster-management, Kubernetes administration, and storage-management servers |
One IP address per attached management interface |
|
Control-plane BMCs, infrastructure BMCs, and infrastructure DPU-management interfaces |
Count each independently managed interface |
|
OOB, leaf, spine, and ToR switch-management ports |
One IP address per switch-management interface |
|
CIN switch-management interfaces when the site uses CIN |
One IP address per CIN switch-management interface |
|
Vera Rubin NVL72 compute-tray chassis BMCs or DGX Rubin NVL8 chassis BMCs |
Vera Rubin NVL72: 18 compute trays per rack × 8 racks per SU × SUs. DGX Rubin NVL8: 64 systems per SU × SUs. |
|
NVLink switch BMC and OS eth0 |
Two IP addresses per NVLink switch. Vera Rubin NVL72: 9 switches per
rack × 8 racks per SU × 2 addresses × SUs. Each SU uses a |
|
Power shelves and PDUs |
One IP address per power-shelf or PDU management interface. Vera Rubin
NVL72: 8 power shelves per rack × 8 racks per SU × SUs. Each SU uses a
|
|
Compute-tray BlueField BMCs |
One IP address per compute tray in noDPU mode. Vera Rubin NVL72: 18
trays per rack × 8 racks per SU × SUs. Each SU uses a |
|
Kubernetes user, NVIDIA Run:ai, Slurm, and shared service interfaces |
One IP address per service interface or bond |
|
Loopbacks, VIPs, and shared services |
One IP address per logical endpoint |
|
Router or firewall point-to-point link |
Normally two usable IP addresses |