Network Validation for North-South Network#
Once all of the switches are up, verify hardware health and configuration before declaring the North-South network ready for workloads.
Prerequisites and inputs#
Confirm network planning and addressing align with your site and DGX model; refer to Network planning and design and subnet guidance in that chapter where applicable.
Complete BCM bootstrap through head-node and rack-side OOB so switches can be reached for provisioning; follow BCM bootstrap workflow.
Run netautogen and related tooling so BCM holds the expected devices, categories, and addressing; refer to Application workflow and Input file format and manifest.
Fabric underlay routing#
Check the following components for fabric underlay routing:
EVPN Anycast Gateway
Anycast gateway is enabled on all VTEPs.
All VTEPs share:
Same gateway IP.
Same virtual MAC (for example,
00:00:5E:00:01:<fabric-id>).
Hosts see a consistent default gateway across all racks.
Traffic is routed locally at the ingress VTEP (symmetric IRB).
ARP/ND information is distributed via EVPN Type-2 routes (MAC/IP).
Fabric overlay routing (EVPN)#
To show the Ethernet segments across all VNIs, run the following command:
To show the Ethernet segments across all VNIs:
nv show evpn multihoming
Figure 19 Ethernet segments across all VNIs#
Show Ethernet segment information#
The following steps show how to show the Ethernet segments across all VNIs, information about a specific ESI, the Ethernet segments for a specific VNI, the Ethernet segments across all VNIs learned through type-1 and type-4 routes, and verify ESI to VRF information.
To show the Ethernet segments across all VNIs, run the following command:
$ nv show evpn multihoming esi
Figure 20 Ethernet segments across all VNIs#
To show information about a specific ESI, run the following command:
$ nv show evpn multihoming esi <ESI_ID>
Figure 21 Ethernet segments across all VNIs#
To show the Ethernet segments for a specific VNI, run the following command:
$ nv show evpn vni <VLAN> multihoming esi
Figure 22 Ethernet segments across all VNIs#
To show the Ethernet segments across all VNIs learned through type-1 and type-4 routes, run the NVUE command:
$ nv show evpn multihoming bgp-info esi
Figure 23 Ethernet segments across all VNIs#
To verify ESI to VRF information, run the following command:
$ sudo vtysh -c 'show bgp l2vpn evpn es-vrf'
Figure 24 Ethernet segments across all VNIs#
To verify EVPN type-1 and type-4 routes learned, run the following command:
$ sudo vtysh -c 'show bgp l2vpn evpn route type ead'
Figure 25 Ethernet segments across all VNIs#
To verify NVE interface (VTEP) state and configuration, run the following command:
$ nv show nve vxlan
Figure 26 Ethernet segments across all VNIs#
Customer network reachability#
Check the following components for customer network reachability:
Customer edge to cluster border
BGP IPv4 AF neighbors
BGP prefix exchange
Next-hop reachability
Packet loss
Customer (external) to cluster (internal)
End-to-end reachability (if available), dependent on end hosts connected to the fabric (for example, DGX)
Packet loss
Negative testing#
Check the following components for negative testing:
Customer edge failover
Disable switch(es) / link(s) / BGP neighbor(s)
End-to-end reachability
Packet loss / recovery time
Cluster fabric failover
Disable switch(es) / link(s) / BGP neighbor(s)
End-to-end reachability
Packet loss / recovery time
EVPN multihoming troubleshooting reference#
The following table summarizes common issues, symptoms, root causes, and fixes when validating EVPN multihoming and related fabric behavior.
Issue |
Symptoms |
Root cause |
How to fix |
|---|---|---|---|
LACP mismatch / one-sided |
Only one link forwarding, low bandwidth |
LACP mode mismatch (active/passive), config mismatch |
Ensure both sides use LACP active, same speed/MTU, same port-channel config |
One link down |
Loss of redundancy, traffic imbalance |
Physical issue, cabling, optics |
Check link state, optics, cabling; verify interface is up on both sides |
ESI mismatch |
EVPN-MH not forming |
Different ESI configured on each switch |
Configure identical ESI on both switches |
Missing ES routes (Type-1) |
MH not recognized by peers |
EVPN not advertising ES routes |
Verify BGP EVPN is enabled and ES routes are advertised |
Missing Type-4 routes |
DF election not working |
Control-plane issue or EVPN config missing |
Check BGP EVPN neighbors, ensure Type-4 routes exchanged |
DF election failure |
Traffic blackhole or duplication |
Both switches think DF or no DF |
Verify Type-4 routes, check DF state, ensure consistent config |
MAC flapping |
Logs show MAC moving between switches |
Loop, incorrect cabling, or MH misconfig |
Fix cabling, verify ESI consistency, check for loops |
Split-brain |
Both switches act independently |
Peer/control-plane failure |
Check peer-link or EVPN control plane, restore synchronization |
No MAC learning (Type-2 missing) |
Host unreachable from remote racks |
MAC not advertised via EVPN |
Verify EVPN Type-2 routes, check MAC learning on local switch |
ARP/ND failure |
Cannot resolve IP → MAC |
ARP suppression or sync issue |
Check ARP table, verify EVPN Type-2 routes |
Asymmetric routing |
Traffic enters one switch, exits another |
Incorrect hashing or routing design |
Verify ECMP/hash settings, check routing consistency |
Traffic blackholing |
Intermittent or total traffic loss |
Missing DF, wrong VNI, or routing issue |
Check DF election, VNI mapping, and routing tables |
VXLAN/VNI mismatch |
No connectivity across fabric |
Wrong VNI or VLAN mapping |
Verify VNI-to-VLAN mapping on all VTEPs |
Host hashing imbalance |
One link heavily used |
LACP hashing behavior |
Adjust hashing algorithm (L3/L4), validate traffic distribution |
MTU mismatch |
Packet drops, performance issues |
Different MTU across path |
Align MTU across host, leaf, and fabric (VXLAN requires larger MTU) |