Using the Tool When an Unknown Platform Error Occurs#
When an unknown platform error occurs on an MGX or a GH200 system, to resolve the error, in the --target
option, use the servertype suboption.
Note
The suboption can be used with all commands that use --target
option (see the sample output).
For MGX platforms, use servertype=MGX
and for GB200 NVL platforms use servertype=GB200
.
$ nvfwupd --target ip=1.1.1.1 user=*** password=*** servertype=GH200 show_version –p nvfw_P4764_0001_240405.1.0_dbg-signed.fwpkg
System Model: P3809
Part number: 699-13809-0400-500
Serial number: 1585023610207
Packages: ['P4764_0001_240405.1.0']
System IP: XXXX
Firmware Devices:
AP Name Sys Version Pkg Version Up-To-Date
------- ----------- -----------
Cpld0 0.00 N/A No
FW_BMC_0 GH-24.01-6 N/A No
FW_ERoT_BMC_0 01.03.0131.0000_n01 N/A No
HGX_CPU_0 01.02.00 01.02.04 No
HGX_CPU_1 01.02.00 01.02.04 No
HGX_Cpld0 0.13 0.17 No
HGX_ERoT_CPU_0 01.03.0131.0000_n01 01.03.0136.0000_n01 No
HGX_ERoT_CPU_1 01.03.0131.0000_n01 01.03.0136.0000_n01 No
HGX_ERoT_FPGA_0 01.03.0131.0000_n01 01.03.0136.0000_n01 No
HGX_ERoT_GPU_0 01.03.0131.0000_n01 01.03.0136.0000_n01 No
HGX_ERoT_GPU_1 01.03.0131.0000_n01 01.03.0136.0000_n01 No
HGX_FW_BMC_0 GH-24.01-6 24.03.C No
HGX_FW_FPGA_0 0.32 0.3A No
HGX_HMC_ERoT_HMC_0 01.03.0131.0000_n01 01.03.0136.0000_n01 No
-------------------------------------------------------------------------------------------
Error Code: 0