Monitoring Interfaces and Transceivers Using ethtool
The ethtool
command enables you to query or control the network driver
and hardware settings. It takes the device name (like swp1) as an
argument. When the device name is the only argument to ethtool
, it
prints the current settings of the network device. See man ethtool(8)
for details. Not all options are currently supported on switch port
interfaces.
Monitor Interface Status Using ethtool
To check the status of an interface using ethtool
:
cumulus@switch:~$ ethtool swp1
Settings for swp1:
Supported ports: [ FIBRE ]
Supported link modes: 1000baseT/Full
10000baseT/Full
Supported pause frame use: No
Supports auto-negotiation: No
Advertised link modes: 1000baseT/Full
Advertised pause frame use: No
Advertised auto-negotiation: No
Speed: 10000Mb/s
Duplex: Full
Port: FIBRE
PHYAD: 0
Transceiver: external
Auto-negotiation: off
Current message level: 0x00000000 (0)
Link detected: yes
The switch hardware contains the active port settings.
The output of ethtool swpXX
shows the port settings stored in the
kernel. The switchd
process keeps the hardware and kernel in sync for
the important port settings (speed, auto-negotiation, and link detected)
when they change. However, many of the fields in ethtool
, like
Supported Link Modes and Advertised Link Modes are not updated based on
the actual module inserted in the port and therefore are incorrect or
misleading.
To query interface statistics:
cumulus@switch:~$ sudo ethtool -S swp1
NIC statistics:
HwIfInOctets: 1435339
HwIfInUcastPkts: 11795
HwIfInBcastPkts: 3
HwIfInMcastPkts: 4578
HwIfOutOctets: 14866246
HwIfOutUcastPkts: 11791
HwIfOutMcastPkts: 136493
HwIfOutBcastPkts: 0
HwIfInDiscards: 0
HwIfInL3Drops: 0
HwIfInBufferDrops: 0
HwIfInAclDrops: 28
HwIfInDot3LengthErrors: 0
HwIfInErrors: 0
SoftInErrors: 0
SoftInDrops: 0
SoftInFrameErrors: 0
HwIfOutDiscards: 0
HwIfOutErrors: 0
HwIfOutQDrops: 0
HwIfOutNonQDrops: 0
SoftOutErrors: 0
SoftOutDrops: 0
SoftOutTxFifoFull: 0
HwIfOutQLen: 0
View and Clear Interface Counters
Interface counters contain information about an interface. You can view
this information when you run cl-netstat
, ifconfig
, or cat /proc/net/dev
. You can also use cl-netstat
to save or clear this
information:
cumulus@switch:~$ sudo cl-netstat
Kernel Interface table
Iface MTU Met RX_OK RX_ERR RX_DRP RX_OVR TX_OK TX_ERR TX_DRP TX_OVR Flg
---------------------------------------------------------------------------------------------
eth0 1500 0 611 0 0 0 487 0 0 0 BMRU
lo 16436 0 0 0 0 0 0 0 0 0 LRU
swp1 1500 0 0 0 0 0 0 0 0 0 BMU
cumulus@switch:~$ sudo cl-netstat -c
Cleared counters
Option | Description |
---|---|
-c | Copies and clears statistics. It does not clear counters in the kernel or hardware. The |
-d | Deletes saved statistics, either the The |
-D | Deletes all saved statistics. |
-l | Lists saved tags. |
-r | Displays raw statistics (unmodified output of |
-t <tag name> | Saves statistics with |
-v | Prints |
On Mellanox switches, Cumulus Linux updates physical counters to the kernel every two seconds and virtual interfaces (such as VLAN interfaces) every ten seconds. You cannot change these values. Because the update process takes a lower priority than other switchd
processes, the interval might be longer when the system is under a heavy load.
Monitor Switch Port SFP/QSFP Hardware Information Using ethtool
To see hardware capabilities and measurement information on the SFP or
QSFP module installed in a particular port, use the ethtool -m
command. If the SFP/QSFP supports Digital Optical Monitoring (that is,
the Optical diagnostics support
field in the output below is set to
Yes), the optical power levels and thresholds are also printed below
the standard hardware details.
In the sample output below, you can see that this module is a
1000BASE-SX short-range optical module, manufactured by JDSU, part
number PLRXPL-VI-S24-22. The second half of the output displays the
current readings of the Tx power levels (Laser output power
) and Rx
power (Receiver signal average optical power
), temperature, voltage
and alarm threshold settings.
cumulus@switch$ sudo ethtool -m swp3
Identifier : 0x03 (SFP)
Extended identifier : 0x04 (GBIC/SFP defined by 2-wire interface ID)
Connector : 0x07 (LC)
Transceiver codes : 0x00 0x00 0x00 0x01 0x20 0x40 0x0c 0x05
Transceiver type : Ethernet: 1000BASE-SX
Transceiver type : FC: intermediate distance (I)
Transceiver type : FC: Shortwave laser w/o OFC (SN)
Transceiver type : FC: Multimode, 62.5um (M6)
Transceiver type : FC: Multimode, 50um (M5)
Transceiver type : FC: 200 MBytes/sec
Transceiver type : FC: 100 MBytes/sec
Encoding : 0x01 (8B/10B)
BR, Nominal : 2100MBd
Rate identifier : 0x00 (unspecified)
Length (SMF,km) : 0km
Length (SMF) : 0m
Length (50um) : 300m
Length (62.5um) : 150m
Length (Copper) : 0m
Length (OM3) : 0m
Laser wavelength : 850nm
Vendor name : JDSU
Vendor OUI : 00:01:9c
Vendor PN : PLRXPL-VI-S24-22
Vendor rev : 1
Optical diagnostics support : Yes
Laser bias current : 21.348 mA
Laser output power : 0.3186 mW / -4.97 dBm
Receiver signal average optical power : 0.3195 mW / -4.96 dBm
Module temperature : 41.70 degrees C / 107.05 degrees F
Module voltage : 3.2947 V
Alarm/warning flags implemented : Yes
Laser bias current high alarm : Off
Laser bias current low alarm : Off
Laser bias current high warning : Off
Laser bias current low warning : Off
Laser output power high alarm : Off
Laser output power low alarm : Off
Laser output power high warning : Off
Laser output power low warning : Off
Module temperature high alarm : Off
Module temperature low alarm : Off
Module temperature high warning : Off
Module temperature low warning : Off
Module voltage high alarm : Off
Module voltage low alarm : Off
Module voltage high warning : Off
Module voltage low warning : Off
Laser rx power high alarm : Off
Laser rx power low alarm : Off
Laser rx power high warning : Off
Laser rx power low warning : Off
Laser bias current high alarm threshold : 10.000 mA
Laser bias current low alarm threshold : 1.000 mA
Laser bias current high warning threshold : 9.000 mA
Laser bias current low warning threshold : 2.000 mA
Laser output power high alarm threshold : 0.8000 mW / -0.97 dBm
Laser output power low alarm threshold : 0.1000 mW / -10.00 dBm
Laser output power high warning threshold : 0.6000 mW / -2.22 dBm
Laser output power low warning threshold : 0.2000 mW / -6.99 dBm
Module temperature high alarm threshold : 90.00 degrees C / 194.00 degrees F
Module temperature low alarm threshold : -40.00 degrees C / -40.00 degrees F
Module temperature high warning threshold : 85.00 degrees C / 185.00 degrees F
Module temperature low warning threshold : -40.00 degrees C / -40.00 degrees F
Module voltage high alarm threshold : 4.0000 V
Module voltage low alarm threshold : 0.0000 V
Module voltage high warning threshold : 3.6450 V
Module voltage low warning threshold : 2.9550 V
Laser rx power high alarm threshold : 1.6000 mW / 2.04 dBm
Laser rx power low alarm threshold : 0.0100 mW / -20.00 dBm
Laser rx power high warning threshold : 1.0000 mW / 0.00 dBm
Laser rx power low warning threshold : 0.0200 mW / -16.99 dBm