VXLAN Active-Active Mode

VXLAN active-active mode allows a pair of MLAG switches to act as a single VTEP, providing active-active VXLAN termination for bare metal as well as virtualized workloads.

There are some differences whether you’re deploying this with EVPN or LNV. This chapter outlines the configurations for both options.

Terminology

TermDefinition
VTEPThe virtual tunnel endpoint. This is an encapsulation and decapsulation point for VXLANs.
active-active VTEPA pair of switches acting as a single VTEP.
ToRThe top of rack switch; also referred to as a leaf or access switch.
spineThe aggregation switch for multiple leafs. Specifically used when a data center is using a Clos network architecture. Read more about spine-leaf architecture in this white paper.
exit leafA switch dedicated to peering the Clos network to an outside network; also referred to as a border leaf, service leaf, or edge leaf.
anycastAn IP address that is advertised from multiple locations. Anycast enables multiple devices to share the same IP address and effectively load balance traffic across them. With VXLAN, anycast is used to share a VTEP IP address between a pair of MLAG switches.
RIOTRouting in and out of tunnels. A Broadcom feature for routing in and out of tunnels. Allows a VXLAN bridge to have a switch VLAN interface associated with it, and traffic to exit a VXLAN into the layer 3 fabric. Also called VXLAN Routing.
VXLAN routingThe industry standard term for the ability to route in and out of a VXLAN. Equivalent to the Broadcom RIOT feature.
clagd-vxlan-anycast-ipThe anycast address for the MLAG pair to share and bind to when MLAG is up and running.

Configure VXLAN Active-active Mode

VXLAN active-active mode requires the following underlying technologies to work correctly.

TechnologyMore Information
MLAGRefer to the MLAG chapter for more detailed configuration information. Configurations for the demonstration are provided below.
OSPF or BGPRefer to the OSPF chapter or the BGP chapter for more detailed configuration information. Configurations for the BGP demonstration are provided below.
STPYou must enable BPDU filter and BPDU guard in the VXLAN interfaces if STP is enabled in the bridge that is connected to the VXLAN. Configurations for the demonstration are provided below.

Active-active VTEP Anycast IP Behavior

You must provision each individual switch within an MLAG pair with a virtual IP address in the form of an anycast IP address for VXLAN data-path termination. The VXLAN termination address is an anycast IP address that you configure as a clagd parameter (clagd-vxlan-anycast-ip) under the loopback interface. clagd dynamically adds and removes this address as the loopback interface address as follows:

  1. When the switches boot up, ifupdown2 places all VXLAN interfaces in a PROTO_DOWN state. The configured anycast addresses are not configured yet.

  2. MLAG peering takes place and a successful VXLAN interface consistency check between the switches occurs.

  3. clagd (the daemon responsible for MLAG) adds the anycast address to the loopback interface as a second address. It then changes the local IP address of the VXLAN interface from a unique address to the anycast virtual IP address and puts the interface in an UP state.

In order for the anycast address to activate, you must configure a VXLAN interface on each switch in the MLAG pair.

Failure Scenario Behaviors

ScenarioBehavior
The peer link goes down.The primary MLAG switch continues to keep all VXLAN interfaces up with the anycast IP address while the secondary switch brings down all VXLAN interfaces and places them in a PROTO_DOWN state. The secondary MLAG switch removes the anycast IP address from the loopback interface.
One of the switches goes down.The other operational switch continues to use the anycast IP address.
clagd is stopped.All VXLAN interfaces are put in a PROTO_DOWN state. The anycast IP address is removed from the loopback interface and the local IP addresses of the VXLAN interfaces are changed from the anycast IP address to unique non-virtual IP addresses.
MLAG peering could not be established between the switches.clagd brings up all the VXLAN interfaces after the reload timer expires with the configured anycast IP address. This allows the VXLAN interface to be up and running on both switches even though peering is not established.
The peer link goes down but the peer switch is up (the backup link is active).All VXLAN interfaces are put into a PROTO_DOWN state on the secondary switch.
The anycast IP address is different on the MLAG peers.The VXLAN interface is placed into a PROTO_DOWN state on the secondary switch.

Check VXLAN Interface Configuration Consistency

The active-active configuration for a given VXLAN interface must be consistent between the MLAG switches for correct traffic behavior. MLAG ensures that the configuration consistency is met before bringing up the VXLAN interfaces

The consistency checks include:

  • The anycast virtual IP address for VXLAN termination must be the same on each pair of switches.
  • A VXLAN interface with the same VXLAN ID must be configured and administratively up on both switches.

You can use the clagctl command to check if any VXLAN switches are in a PROTO_DOWN state.

Configure the Anycast IP Address

With MLAG peering, both switches use an anycast IP address for VXLAN encapsulation and decapsulation. This allows remote VTEPs to learn the host MAC addresses attached to the MLAG switches against one logical VTEP, even though the switches independently encapsulate and decapsulate layer 2 traffic originating from the host. You can configure the anycast address under the loopback interface, as shown below.

auto lo
iface lo inet loopback
  address 10.0.0.11/32
  clagd-vxlan-anycast-ip 10.10.10.20

auto lo
iface lo inet loopback
  address 10.0.0.12/32
  clagd-vxlan-anycast-ip 10.10.10.20

Example VXLAN Active-Active Configuration

Note the configuration of the local IP address in the VXLAN interfaces below. They are configured with individual IP addresses, which clagd changes to anycast upon MLAG peering.

FRRouting Configuration

You can configure the layer 3 fabric using BGP or OSPF. The following example uses BGP unnumbered. The MLAG switch configuration for the topology above is shown below.

Layer 3 IP Addressing

The IP address configuration for this example:

auto lo
iface lo inet loopback
    address 10.0.0.21/32

auto eth0 iface eth0 inet dhcp

# downlinks auto swp1 iface swp1

auto swp2 iface swp2

auto swp3 iface swp3

auto swp4 iface swp4

auto swp29 iface swp29

auto swp30 iface swp30

auto lo
iface lo inet loopback
    address 10.0.0.22/32

auto eth0 iface eth0 inet dhcp

# downlinks auto swp1 iface swp1

auto swp2 iface swp2

auto swp3 iface swp3

auto swp4 iface swp4

auto swp29 iface swp29

auto swp30 iface swp30

auto lo
iface lo inet loopback
    address 10.0.0.11/32
    clagd-vxlan-anycast-ip 10.10.10.20

auto eth0 iface eth0 inet dhcp

# peerlinks auto swp49 iface swp49

auto swp50 iface swp50

auto peerlink iface peerlink bond-slaves swp49 swp50

auto peerlink.4094 iface peerlink.4094 address 169.254.1.1/30 clagd-peer-ip 169.254.1.2 clagd-backup-ip 10.0.0.12 clagd-sys-mac 44:38:39:FF:40:94

# Downlinks auto swp1 iface swp1

auto bond0 iface bond0 bond-slaves swp1 clag-id 1

auto bridge iface bridge bridge-vlan-aware yes bridge-ports peerlink bond0 vni10 vni20 bridge-vids 10 20

auto vlan10 iface vlan10

auto vlan20 iface vlan20

auto vni10 iface vni10 vxlan-id 10 vxlan-local-tunnelip 10.0.0.11 bridge-access 10 bridge-learning off mstpctl-bpduguard yes mstpctl-portbpdufilter yes bridge-arp-nd-suppress on

auto vni20 iface vni20 vxlan-id 20 vxlan-local-tunnelip 10.0.0.11 bridge-access 20 bridge-learning off mstpctl-bpduguard yes mstpctl-portbpdufilter yes bridge-arp-nd-suppress on

# uplinks auto swp51 iface swp51

auto swp52 iface swp52

auto lo
iface lo inet loopback
    address 10.0.0.12/32
    clagd-vxlan-anycast-ip 10.10.10.20

auto eth0 iface eth0 inet dhcp

# peerlinks auto swp49 iface swp49

auto swp50 iface swp50

auto peerlink iface peerlink bond-slaves swp49 swp50

auto peerlink.4094 iface peerlink.4094 address 169.254.1.2/30 clagd-peer-ip 169.254.1.1 clagd-backup-ip 10.0.0.11 clagd-sys-mac 44:38:39:FF:40:94

# Downlinks auto swp1 iface swp1

auto bond0 iface bond0 bond-slaves swp1 clag-id 1

auto bridge iface bridge bridge-vlan-aware yes bridge-ports peerlink bond0 vni10 vni20 bridge-vids 10 20

auto vlan10 iface vlan10

auto vlan20 iface vlan20

auto vni10 iface vni10 vxlan-id 10 vxlan-local-tunnelip 10.0.0.12 bridge-access 10 bridge-learning off mstpctl-bpduguard yes mstpctl-portbpdufilter yes bridge-arp-nd-suppress on

auto vni20 iface vni20 vxlan-id 20 vxlan-local-tunnelip 10.0.0.12 bridge-access 20 bridge-learning off mstpctl-bpduguard yes mstpctl-portbpdufilter yes bridge-arp-nd-suppress on

# uplinks auto swp51 iface swp51

auto swp52 iface swp52

auto lo
iface lo inet loopback
  address 10.0.0.13/32
  clagd-vxlan-anycast-ip 10.10.10.30

auto eth0 iface eth0 inet dhcp

# peerlinks auto swp49 iface swp49

auto swp50 iface sw50p

auto peerlink iface peerlink bond-slaves swp49 swp50

auto peerlink.4094 iface peerlink.4094 address 169.254.1.1/30 clagd-peer-ip 169.254.1.2 clagd-backup-ip 10.0.0.14 clagd-sys-mac 44:38:39:FF:40:95

# Downlinks auto swp1 iface swp1

auto bond0 iface bond0 bond-slaves swp1 clag-id 1

auto bridge iface bridge bridge-vlan-aware yes bridge-ports peerlink bond0 vni10 vni20 bridge-vids 10 20

auto vlan10 iface vlan10

auto vlan20 iface vlan20

auto vni10 iface vni10 vxlan-id 10 vxlan-local-tunnelip 10.0.0.13 bridge-access 10 bridge-learning off mstpctl-bpduguard yes mstpctl-portbpdufilter yes bridge-arp-nd-suppress on

auto vni20 iface vni20 vxlan-id 20 vxlan-local-tunnelip 10.0.0.13 bridge-access 20 bridge-learning off mstpctl-bpduguard yes mstpctl-portbpdufilter yes bridge-arp-nd-suppress on

# uplinks auto swp51 iface swp51

auto swp52 iface swp52

auto lo
iface lo inet loopback
  address 10.0.0.14/32
  clagd-vxlan-anycast-ip 10.10.10.30

auto eth0 iface eth0 inet dhcp

# peerlinks auto swp49 iface swp49

auto swp50 iface swp50

auto peerlink iface peerlink bond-slaves swp49 swp50

auto peerlink.4094 iface peerlink.4094 address 169.254.1.2/30 clagd-peer-ip 169.254.1.1 clagd-backup-ip 10.0.0.13 clagd-sys-mac 44:38:39:FF:40:95

# Downlinks auto swp1 iface swp1

auto bond0 iface bond0 bond-slaves swp1 clag-id 1

auto bridge iface bridge bridge-vlan-aware yes bridge-ports peerlink bond0 vni10 vni20 bridge-vids 10 20

auto vlan10 iface vlan10

auto vlan20 iface vlan20

auto vni10 iface vni10 vxlan-id 10 vxlan-local-tunnelip 10.0.0.14 bridge-access 10 bridge-learning off mstpctl-bpduguard yes mstpctl-portbpdufilter yes bridge-arp-nd-suppress on

auto vni20 iface vni20 vxlan-id 20 vxlan-local-tunnelip 10.0.0.14 bridge-access 20 bridge-learning off mstpctl-bpduguard yes mstpctl-portbpdufilter yes bridge-arp-nd-suppress on

# uplinks auto swp51 iface swp51

auto swp52 iface swp52

Host Configuration

In this example, the servers are running Ubuntu 14.04. A layer2 bond must be mapped from server01 and server03 to the respective switch. In Ubuntu this is done with subinterfaces.

auto lo
iface lo inet loopback

auto lo iface lo inet static address 10.0.0.31/32

auto eth0 iface eth0 inet dhcp

auto eth1 iface eth1 inet manual bond-master bond0

auto eth2 iface eth2 inet manual bond-master bond0

auto bond0 iface bond0 inet static bond-slaves none bond-miimon 100 bond-min-links 1 bond-mode 802.3ad bond-xmit-hash-policy layer3+4 bond-lacp-rate 1 address 172.16.1.101/24

auto bond0.10 iface bond0.10 inet static address 172.16.10.101/24

auto bond0.20 iface bond0.20 inet static address 172.16.20.101/24

auto lo
iface lo inet loopback

auto lo iface lo inet static address 10.0.0.33/32

auto eth0 iface eth0 inet dhcp

auto eth1 iface eth1 inet manual bond-master bond0

auto eth2 iface eth2 inet manual bond-master bond0

auto bond0 iface bond0 inet static bond-slaves none bond-miimon 100 bond-min-links 1 bond-mode 802.3ad bond-xmit-hash-policy layer3+4 bond-lacp-rate 1 address 172.16.1.103/24

auto bond0.10 iface bond0.10 inet static address 172.16.10.103/24

auto bond0.20 iface bond0.20 inet static address 172.16.20.103/24

Using Active-active Mode with LNV

When using VXLAN active-active mode with lightweight network virtualization (LNV), follow the steps outlined above. In addition, the following configuration steps are needed:

  • Configuring the loopback interface for active-active mode
  • Enabling the registration daemon
  • Configuring a VTEP
  • Enabling the service node daemon
  • Configuring the service node

Terminology

Term

Definition

vxrd

The VXLAN registration daemon. The daemon runs on the switch that is mapping VLANs to VXLANs. You must configure the vxrd daemon to register to a service node. This turns the switch into a VTEP.

vxsnd

The VXLAN service node daemon that you can run to register multiple VTEPs.

vxrd-src-ip

The unique IP address to which the vxrd binds.

vxrd-svcnode-ip

The service node anycast IP address in the topology. In this demonstration, this is an anycast IP address shared by both spine switches.

anycast

When an IP address is advertised from multiple locations. Allows multiple devices to share the same IP and effectively load balance traffic across them. With VXLAN, anycast is used in two places:

  1. To share a VTEP IP address between a pair of MLAG switches.

  2. To load balance traffic for service nodes (for example, service nodes share an IP address).

Configure the Loopback Interface for Active-active Mode

You configure active-active mode as you would for EVPN, as described above, adding two more configuration options to the loopback interface: the vxrd IP address and the service node IP address.

Continuing with the example configuration above, the loopback interface configuration on the leaf switches would look like this:

cumulus@leaf01:~$ net add loopback lo vxrd-src-ip 10.0.0.11
cumulus@leaf01:~$ net add loopback lo vxrd-svcnode-ip 10.10.10.10
cumulus@leaf01:~$ net pending
cumulus@leaf01:~$ net commit
auto lo
iface lo inet loopback
    address 10.0.0.11/32
    vxrd-src-ip 10.0.0.11
    vxrd-svcnode-ip 10.10.10.10
    clagd-vxlan-anycast-ip 10.10.10.20 
cumulus@leaf02:~$ net add loopback lo vxrd-src-ip 10.0.0.12
cumulus@leaf02:~$ net add loopback lo vxrd-svcnode-ip 10.10.10.10
cumulus@leaf02:~$ net pending
cumulus@leaf02:~$ net commit
auto lo
iface lo inet loopback
    address 10.0.0.12/32
    vxrd-src-ip 10.0.0.12
    vxrd-svcnode-ip 10.10.10.10
    clagd-vxlan-anycast-ip 10.10.10.20
cumulus@leaf03:~$ net add loopback lo vxrd-src-ip 10.0.0.13
cumulus@leaf03:~$ net add loopback lo vxrd-svcnode-ip 10.10.10.10
cumulus@leaf03:~$ net pending
cumulus@leaf03:~$ net commit
auto lo
iface lo inet loopback
  address 10.0.0.13/32
  vxrd-src-ip 10.0.0.13
  vxrd-svcnode-ip 10.10.10.10
  clagd-vxlan-anycast-ip 10.10.10.30
cumulus@leaf04:~$ net add loopback lo vxrd-src-ip 10.0.0.14
cumulus@leaf04:~$ net add loopback lo vxrd-svcnode-ip 10.10.10.10
cumulus@leaf04:~$ net pending
cumulus@leaf04:~$ net commit
auto lo
iface lo inet loopback
  address 10.0.0.14/32
  vxrd-src-ip 10.0.0.14
  vxrd-svcnode-ip 10.10.10.10
  clagd-vxlan-anycast-ip 10.10.10.30

Enable the Registration Daemon

You must enable the registration daemon (vxrd) on each ToR switch acting as a VTEP that is participating in the VXLAN. The daemon is installed by default.

  1. Open the /etc/default/vxrd configuration file in a text editor.

  2. Enable the daemon, then save the file.

    START=yes
    
  3. Restart the vxrd daemon.

    cumulus@leaf0X:~$ sudo systemctl restart vxrd.service
    

Configure a VTEP

The registration node is already configured in /etc/network/interfaces; no additional configuration is typically needed. However, you can configure the VTEP in the /etc/vxrd.conf file instead, which has additional configuration knobs available.

Enable the Service Node Daemon

  1. Open the /etc/default/vxsnd configuration file in a text editor.

  2. Enable the daemon, then save the file:

    START=yes
    
  3. Restart the daemon.

    cumulus@spine0X:~$ sudo systemctl restart vxsnd.service
    

Configure the Service Node

To configure the service node daemon, edit the /etc/vxsnd.conf configuration file:

svcnode_ip = 10.10.10.10

src_ip = 10.0.0.21

svcnode_peers = 10.0.0.21 10.0.0.22

Full configuration of vxsnd.conf
[common]
# Log level is one of DEBUG, INFO, WARNING, ERROR, CRITICAL
#loglevel = INFO

# Destination for log message. Can be a file name, 'stdout', or 'syslog' #logdest = syslog

# log file size in bytes. Used when logdest is a file #logfilesize = 512000

# maximum number of log files stored on disk. Used when logdest is a file #logbackupcount = 14

# The file to write the pid. If using monit, this must match the one # in the vxsnd.rc #pidfile = /var/run/vxsnd.pid

# The file name for the unix domain socket used for mgmt. #udsfile = /var/run/vxsnd.sock

# UDP port for vxfld control messages #vxfld_port = 10001

# This is the address to which registration daemons send control messages for # registration and/or BUM packets for replication svcnode_ip = 10.10.10.10

# Holdtime (in seconds) for soft state. It is used when sending a # register msg to peers in response to learning a <vni, addr> from a # VXLAN data pkt #holdtime = 90

# Local IP address to bind to for receiving inter-vxsnd control traffic src_ip = 10.0.0.21

[vxsnd] # Space separated list of IP addresses of vxsnd to share state with svcnode_peers = 10.0.0.21 10.0.0.22

# When set to true, the service node will listen for vxlan data traffic # Note: Use 1, yes, true, or on, for True and 0, no, false, or off, # for False #enable_vxlan_listen = true

# When set to true, the svcnode_ip will be installed on the loopback # interface, and it will be withdrawn when the vxsnd is no longer in # service. If set to true, the svcnode_ip configuration # variable must be defined. # Note: Use 1, yes, true, or on, for True and 0, no, false, or off, # for False #install_svcnode_ip = false

# Seconds to wait before checking the database to age out stale entries #age_check = 90

svcnode_ip = 10.10.10.10

src_ip = 10.0.0.22

svcnode_peers = 10.0.0.21 10.0.0.22

Full configuration of vxsnd.conf
[common]
# Log level is one of DEBUG, INFO, WARNING, ERROR, CRITICAL
#loglevel = INFO

# Destination for log message. Can be a file name, 'stdout', or 'syslog' #logdest = syslog

# log file size in bytes. Used when logdest is a file #logfilesize = 512000

# maximum number of log files stored on disk. Used when logdest is a file #logbackupcount = 14

# The file to write the pid. If using monit, this must match the one # in the vxsnd.rc #pidfile = /var/run/vxsnd.pid

# The file name for the unix domain socket used for mgmt. #udsfile = /var/run/vxsnd.sock

# UDP port for vxfld control messages #vxfld_port = 10001

# This is the address to which registration daemons send control messages for # registration and/or BUM packets for replication svcnode_ip = 10.10.10.10

# Holdtime (in seconds) for soft state. It is used when sending a # register msg to peers in response to learning a <vni, addr> from a # VXLAN data pkt #holdtime = 90

# Local IP address to bind to for receiving inter-vxsnd control traffic src_ip = 10.0.0.22

[vxsnd] # Space separated list of IP addresses of vxsnd to share state with svcnode_peers = 10.0.0.21 10.0.0.22

# When set to true, the service node will listen for vxlan data traffic # Note: Use 1, yes, true, or on, for True and 0, no, false, or off, # for False #enable_vxlan_listen = true

# When set to true, the svcnode_ip will be installed on the loopback # interface, and it will be withdrawn when the vxsnd is no longer in # service. If set to true, the svcnode_ip configuration # variable must be defined. # Note: Use 1, yes, true, or on, for True and 0, no, false, or off, # for False #install_svcnode_ip = false

# Seconds to wait before checking the database to age out stale entries #age_check = 90

Troubleshooting

In addition to troubleshooting single-attached configurations, there is now the MLAG daemon (clagd) to consider. The clagctl command gives the output of MLAG behavior and any inconsistencies that might arise between a MLAG pair.

cumulus@leaf01$ clagctl
The peer is alive
     Our Priority, ID, and Role: 32768 44:38:39:00:00:35 primary
    Peer Priority, ID, and Role: 32768 44:38:39:00:00:36 secondary
          Peer Interface and IP: peerlink.4094 169.254.1.2
               VxLAN Anycast IP: 10.10.10.30
                      Backup IP: 10.0.0.14 (inactive)
                     System MAC: 44:38:39:ff:40:95
CLAG Interfaces
Our Interface      Peer Interface     CLAG Id   Conflicts              Proto-Down Reason
----------------   ----------------   -------   --------------------   -----------------
           bond0   bond0              1         -                      -
         vxlan20   vxlan20            -         -                      -
          vxlan1   vxlan1             -         -                      -
         vxlan10   vxlan10            -         -                      -

The additions to normal MLAG behavior are the following:

OutputExplanation
VXLAN Anycast IP: 10.10.10.30The anycast IP address being shared by the MLAG pair for VTEP termination is in use and is 10.10.10.30.
Conflicts: -There are no conflicts for this MLAG Interface.
Proto-Down Reason: -The VXLAN is up and running (there is no Proto-Down).

In the next example the vxlan-id on VXLAN10 is switched to the wrong vxlan-id. When the clagctl command is run, you see that VXLAN10 goes down because this switch is the secondary switch and the peer switch takes control of VXLAN. The reason code is vxlan-single indicating that there is a vxlan-id mis-match on VXLAN10.

cumulus@leaf02$ clagctl
The peer is alive
    Peer Priority, ID, and Role: 32768 44:38:39:00:00:11 primary
     Our Priority, ID, and Role: 32768 44:38:39:00:00:12 secondary
          Peer Interface and IP: peerlink.4094 169.254.1.1
               VxLAN Anycast IP: 10.10.10.20
                      Backup IP: 10.0.0.11 (inactive)
                     System MAC: 44:38:39:ff:40:94
CLAG Interfaces
Our Interface      Peer Interface     CLAG Id   Conflicts              Proto-Down Reason
----------------   ----------------   -------   --------------------   -----------------
           bond0   bond0              1         -                      -
         vxlan20   vxlan20            -         -                      -
          vxlan1   vxlan1             -         -                      -
         vxlan10   -                  -         -                      vxlan-single

Caveats and Errata

Do not reuse the VLAN used for the peer link layer 3 subinterface for any other interface in the system. A high VLAN ID value is recommended. For more information on VLAN ID ranges, refer to the VLAN-aware bridge chapter.

Bonds with Vagrant in Cumulus VX

Bonds (or LACP Etherchannels) fail to work in a Vagrant setup unless the link is set to promiscuous mode. This is a limitation on virtual topologies only, and is not needed on real hardware.

auto swp49
iface swp49
  #for vagrant so bonds work correctly
  post-up ip link set $IFACE promisc on
 
auto swp50
iface swp50
  #for vagrant so bonds work correctly
  post-up ip link set $IFACE promisc on

For more information on using Cumulus VX and Vagrant, refer to the Cumulus VX documentation.

With LNV, Unique Node ID Required for vxrd in Cumulus VX

vxrd requires a unique node_id for each individual switch. This node_id is based off the first interface’s MAC address; when using certain virtual topologies like Vagrant, both leaf switches within an MLAG pair can generate the same exact unique node_id. You must configure one of the node_ids manually (or make sure the first interface always has a unique MAC address), as they are not unique.

To verify the node_id that gets configured by your switch, use the vxrdctl get config command:

cumulus@leaf01$ vxrdctl get config
{
    "concurrency": 1000,
    "config_check_rate": 60,
    "debug": false,
    "eventlet_backdoor_port": 9000,
    "head_rep": true,
    "holdtime": 90,
    "logbackupcount": 14,
    "logdest": "syslog",
    "logfilesize": 512000,
    "loglevel": "INFO",
    "max_packet_size": 1500,
    "node_id": 13,
    "pidfile": "/var/run/vxrd.pid",
    "refresh_rate": 3,
    "src_ip": "10.2.1.50",
    "svcnode_ip": "10.10.10.10",
    "udsfile": "/var/run/vxrd.sock",
    "vxfld_port": 10001
}

To set the node_id manually:

  1. Open /etc/vxrd.conf in a text editor.

  2. Set the node_id value within the common section, then save the file:

    [common]
    node_id = 13
    

Ensure that each leaf has a separate node_id so that active-active mode can function correctly.

Network virtualization chapter, Cumulus Linux user guide