If you are using the current version of Cumulus Linux, the content on this page may not be up to date. The current version of the documentation is available here. If you are redirected to the main page of the user guide, then this page may have been renamed; please search for it there.

VXLAN Scale

On Broadcom Trident II and Tomahawk switches running Cumulus Linux, there is a limit to the number of VXLANs you can configure simultaneously. The limit most often given is 2000 VXLANs, but you might want to get more specific and know exactly the limit for your specific design.

While this limitation does apply to Trident II+, Trident3, or Maverick ASICs, Cumulus Linux supports the same number of VXLANs on these ASICs as it does for Trident II or Tomahawk ASICs.

Mellanox Spectrum ASICs do not have a limitation on the number of VXLANs that they can support.

The limit is a physical to virtual mapping where a switch can hold 15000 mappings in hardware before you encounter hash collisions. There is also an upper limit of around 3000 VLANs you can configure before you hit the reserved range (Cumulus Linux uses 3000-3999 by default). Cumulus Linux typically uses a soft number because the math is unique to each environment. An internal VLAN is consumed by each layer 3 port, subinterface, traditional bridge, and the VLAN-aware bridge. Therefore, the number of configurable VLANs is:

(total configurable 802.1q VLANs) - (reserved VLANS) - (physical or logical interfaces) =

4094-999-eth0-loopback = 3093 by default (without any other configuration)

The equation for the number of configurable VXLANs looks like this:

(number of trunks) * (VXLAN/VLANs per trunk) = 15000 - (Linux logical and physical interfaces)

For example, on a 10Gb switch with 48 * 10 G ports and 6 * 40G uplinks, you can calculate for X, the amount of configurable VXLANs:

48 * X = 15000 - (48 downlinks + 6 uplinks + 1 loopback + 1 eth0 + 1 bridge)

48 * X = 14943

X = 311 VXLANs

Similarly, you can apply this logic to a 32 port 100G switch where 16 ports are broken up to 4 * 25 Gbps ports, for a total of 64 * 25 Gbps ports:

64 * X = 15000 - (64 downlinks + 16 uplinks + 1 loopback + 1 eth0 + 1 bridge)

64 * X = 14917

X = 233 VXLANs

However, not all ports are trunks for all VXLANs (or at least not all the time). It is much more common for subsets of ports to be used for different VXLANs. For example, a 10G (48 * 10G + 6 * 40G uplinks) can have the following configuration:

PortsTrunks
swp1-20100 VXLAN/VLANs
swp21-30100 VXLAN/VLANs
swp31-48X VXLAN/VLANs

The equation now looks like this:

20 swps * 100 VXLANs + 10 swps * 100 VXLANs + 18 swps * X VXLANs + (48 downlinks + 6 uplinks + loopback + 1 eth0 + 1 bridge) = 15000

20 swps * 100 VXLANs + 10 swps * 100 VXLANs + 18 swps * X VXLANs = 14943

18 * X = 11943

663 = VXLANS (still configurable) for a total of 863