If you are using the current version of Cumulus Linux, the content on this page may not be up to date. The current version of the documentation is available here. If you are redirected to the main page of the user guide, then this page may have been renamed; please search for it there.

VXLAN Devices

Cumulus Linux supports both single and traditional VXLAN devices.

  • You can configure single VXLAN devices in VLAN-aware bridge mode only.
  • You cannot use a combination of single and traditional VXLAN devices.
  • A traditional VXLAN device configuration supports up to 2000 VNIs and a single VXLAN device configuration supports up to 4000 VNIs.

Traditional VXLAN Device

With a traditional VXLAN device, each VNI is a separate device (for example, vni10, vni20, vni30). You can configure traditional VXLAN devices with NCLU or by manually editing the /etc/network/interfaces file.

The following example configuration:

  • Creates two unique VXLAN devices (vni10 and vni20)
  • Adds each VXLAN device (vni10 and vni20) to the bridge bridge
  • Configures the local tunnel IP address to be the loopback address of the switch
cumulus@leaf01:~$ net add interface swp1 bridge access 10
cumulus@leaf01:~$ net add interface swp2 bridge access 20
cumulus@leaf01:~$ net add vxlan vni10 vxlan id 10
cumulus@leaf01:~$ net add vxlan vni20 vxlan id 20
cumulus@leaf01:~$ net add bridge bridge ports vni10,vni20
cumulus@leaf01:~$ net add bridge bridge vids 10,20
cumulus@leaf01:~$ net add vxlan vni10 bridge access 10
cumulus@leaf01:~$ net add vxlan vni20 bridge access 20
cumulus@leaf01:~$ net add loopback lo vxlan local-tunnelip 10.10.10.1
cumulus@leaf01:~$ net pending
cumulus@leaf01:~$ net commit
You cannot use NVUE commands to configure traditional VXLAN devices.

Edit the /etc/network/interfaces file, then run the ifreload -a command.

cumulus@leaf01:~$ sudo nano /etc/network/interfaces
...
auto lo
iface lo inet loopback
    address 10.10.10.1/32
    vxlan-local-tunnelip 10.10.10.1

auto mgmt
iface mgmt
    address 127.0.0.1/8
    vrf-table auto

auto swp1
iface swp1
    bridge-access 10

auto swp2
iface swp2
    bridge-access 20

auto vni10
iface vni10
    bridge-access 10
    mstpctl-bpduguard yes
    mstpctl-portbpdufilter yes
    vxlan-id 10

auto vni20
iface vni20
    bridge-access 20
    mstpctl-bpduguard yes
    mstpctl-portbpdufilter yes
    vxlan-id 20

auto bridge
iface bridge
    bridge-ports swp1 swp2 vni10 vni20
    bridge-vlan-aware yes
    bridge-vids 10 20
    bridge-pvid 1
cumulus@leaf01:~$ ifreload -a

Single VXLAN Device

With a single VXLAN device, a set of VNIs represent a single device model. The single VXLAN device has a set of attributes that belong to the VXLAN construct. Individual VNIs include a VLAN to VNI mapping and you can specify which VLANs map to the associated VNIs. Single VXLAN device simplifies the configuration and reduces the overhead by replacing multiple traditional VXLAN devices with a single VXLAN device.

Cumulus Linux supports multiple single VXLAN devices when configured with multiple VLAN-aware bridges. You configure multiple single VXLAN devices in the same way you configure a single VXLAN device. Make sure not to duplicate VNIs across single VXLAN device configurations.

The limitations listed for multiple VLAN-aware bridges also apply to multiple single VXLAN devices.

You can configure a single VXLAN device with NVUE or by manually editing the /etc/network/interfaces file. When you configure a single VXLAN device with NVUE, Cumulus Linux creates a unique name for the device in the format vxlan<id>. Cumulus Linux generates the ID using the bridge name as the hash key.

The following example configuration:

  • Creates a single VXLAN device (vxlan48)
  • Maps VLAN 10 to VNI 10 and VLAN 20 to VNI 20
  • Adds the VXLAN device to the default bridge br_default
  • Sets the flooding multicast group for VNI 10 to 239.1.1.110 and the multicast group for VNI 20 to 239.1.1.120
NCLU commands are not supported.
cumulus@leaf01:~$ nv set bridge domain br_default vlan 10 vni 10
cumulus@leaf01:~$ nv set bridge domain br_default vlan 20 vni 20
cumulus@leaf01:~$ nv set nve vxlan source address 10.10.10.1
cumulus@leaf01:~$ nv set bridge domain br_default vlan 10 vni 10 flooding multicast-group 239.1.1.110
cumulus@leaf01:~$ nv set bridge domain br_default vlan 20 vni 20 flooding multicast-group 239.1.1.120
cumulus@leaf01:~$ nv set interface swp1 bridge domain br_default access 10
cumulus@leaf01:~$ nv set interface swp2 bridge domain br_default access 20
cumulus@leaf01:~$ nv config apply

The nv config save command creates the following configuration snippet in the /etc/nvue.d/startup.yaml file:

cumulus@leaf01:~$ sudo cat /etc/nvue.d/startup.yaml
- set:
    bridge:
      domain:
        br_default:
          vlan:
            '10':
              vni:
                '10':
                  flooding:
                    multicast-group: 239.1.1.110
                    enable: on
            '20':
              vni:
                '20':
                  flooding:
                    multicast-group: 239.1.1.120
                    enable: on
    nve:
      vxlan:
        enable: on
        source:
          address: 10.10.10.1
    interface:
      swp1:
        bridge:
          domain:
            br_default:
              access: 10
        type: swp
      swp2:
        bridge:
          domain:
            br_default:
              access: 20
        type: swp

Edit the /etc/network/interfaces file then run the ifreload -a command.

cumulus@leaf01:~$ sudo nano /etc/network/interfaces
...
auto swp1
iface swp1
    bridge-access 10

auto swp2
iface swp2
    bridge-access 20

auto vxlan48
iface vxlan48
    vxlan-mcastgrp-map 10=239.1.1.110 20=239.1.1.120
    bridge-vlan-vni-map 10=10 20=20
    bridge-vids 10 20
    bridge-learning off

auto br_default
iface br_default
    bridge-ports swp1 swp2 vxlan48
    hwaddress 44:38:39:22:01:ab
    bridge-vlan-aware yes
    bridge-vids 10 20
    bridge-pvid 1
cumulus@leaf01:~$ ifreload -a

TC Filters

NVIDIA recommends you run TC filter commands on each VLAN interface on the VTEP to install rules to protect the UDP port that Cumulus Linux uses for VXLAN encapsulation against VXLAN hopping vulnerabilities. If you have VRR configured on the VLAN, add a similar rule for the VRR device.

The following example installs an IPv4 and an IPv6 filter on vlan10 to protect the default port 4879:

cumulus@switch:mgmt:~$ tc filter add dev vlan10 prio 1 protocol ip ingress flower ip_proto udp dst_port 4879 action drop
cumulus@switch:mgmt:~$ tc filter add dev vlan10 prio 2 protocol ipv6 ingress flower ip_proto udp dst_port 4879 action drop

The following example installs an IPv4 and an IPv6 filter on VRR device vlan10-v0 to protect port 4879:

cumulus@switch:mgmt:~$ tc filter add dev vlan10-v0 prio 1 protocol ip ingress flower ip_proto udp dst_port 4879 action drop
cumulus@switch:mgmt:~$ tc filter add dev vlan10-v0 prio 2 protocol ipv6 ingress flower ip_proto udp dst_port 4879 action drop
  • For information about VXLAN devices and static VXLAN tunnels, see Static VXLAN Tunnels.
  • For information about VXLAN devices and EVPN, see EVPN.