If you are using the current version of Cumulus Linux, the content on this page may not be up to date. The current version of the documentation is available here. If you are redirected to the main page of the user guide, then this page may have been renamed; please search for it there.

Equal Cost Multipath Load Sharing - Hardware ECMP

Cumulus Linux enables hardware ECMP by default. Load sharing occurs automatically for all routes with multiple next hops installed. ECMP load sharing supports both IPv4 and IPv6 routes.

How Does ECMP Work?

ECMP operates only on equal cost routes in the Linux routing table. In the following example, the 10.10.10.3/32 route has four possible next hops installed in the routing table:

cumulus@leaf01:mgmt:~$ net show route 10.10.10.3/32
RIB entry for 10.10.10.3/32
===========================
Routing entry for 10.10.10.3/32
  Known via "bgp", distance 20, metric 0, best
  Last update 00:57:26 ago
  * fe80::4638:39ff:fe00:1, via swp51, weight 1
  * fe80::4638:39ff:fe00:3, via swp52, weight 1
  * fe80::4638:39ff:fe00:5, via swp53, weight 1
  * fe80::4638:39ff:fe00:7, via swp54, weight 1


FIB entry for 10.10.10.3/32
===========================
10.10.10.3 nhid 150 proto bgp metric 20

For Cumulus Linux to consider routes equal, the routes must:

  • Originate from the same routing protocol. Routes from different sources are not considered equal. For example, a static route and an OSPF route are not considered for ECMP load sharing.
  • Have equal cost. If two routes from the same protocol are unequal, only the best route installs in the routing table.

When multiple routes are in the routing table, a hash determines through which path a packet follows. To prevent out of order packets, ECMP hashes on a per-flow basis; all packets with the same source and destination IP addresses and the same source and destination ports always hash to the same next hop. ECMP hashing does not keep a record of packets that hash to each next hop and does not guarantee that traffic to each next hop is equal.

Cumulus Linux enables the BGP maximum-paths setting by default and installs multiple routes. Refer to BGP and ECMP.

Custom Hashing

You can configure custom hashing to specify what to include in the hash calculation during load balancing between:

  • Multiple next hops of a layer 3 route (ECMP hashing).
  • Multiple interfaces that are members of the same bond (bond or LAG hashing). For bond hashing, see Bonding - Link Aggregation.

For ECMP load balancing between multiple next-hops of a layer 3 route, you can hash on these fields:

Field
Default Setting/etc/cumulus/datapath/traffic.conf File Parameter
IP protocolonhash_config.ip_prot
Source IP addressonhash_config.sip
Destination IP addressonhash_config.dip
Source portonhash_config.sport
Destination portonhash_config.dport
IPv6 flow labelonhash_config.ip6_label
Ingress interfaceoffhash_config.ing_intf
Inner IP protocoloffhash_config.inner_ip_prot
Inner source IP addressoffhash_config.inner_sip
Inner destination IP addressoffhash_config.inner_dip
Inner source portoffhash_config.inner-sport
Inner destination portoffhash_config.inner_dport
Inner IPv6 flow labeloffhash_config.inner_ip6_label

Cumulus Linux does not provide NVUE commands to configure custom hashing.

To set the hash fields:

  1. Edit the /etc/cumulus/datapath/traffic.conf file:
    • Uncomment the hash_config.enable = true option.
    • Set the hash field to true to include it in the hash calculation or false to omit it from the hash calculation.
  2. Run the echo 1 > /cumulus/switchd/ctrl/hash_config_reload command to reload the configuration. This command does not cause any traffic interruptions.

The following example commands omit the source port and destination port from the hash calculation:

cumulus@switch:~$ sudo nano /etc/cumulus/datapath/traffic.conf
...
# HASH config for  ECMP to enable custom fields
# Fields will be applicable for ECMP hash
# calculation
#Note : Currently supported only for MLX platform
# Uncomment to enable custom fields configured below
hash_config.enable = true

#hash Fields available ( assign true to enable)
#ip protocol
hash_config.ip_prot = true
#source ip
hash_config.sip = true
#destination ip
hash_config.dip = true
#source port
hash_config.sport = false
#destination port
hash_config.dport = false
...
cumulus@switch:~$ echo 1 > /cumulus/switchd/ctrl/hash_config_reload

Cumulus Linux enables symmetric hashing by default. Make sure that the settings for the source IP and destination IP fields match, and that the settings for the source port and destination port fields match; otherwise Cumulus Linux disables symmetric hashing automatically. If necessary, you can disable symmetric hashing manually in the /etc/cumulus/datapath/traffic.conf file by setting symmetric_hash_enable = FALSE.

GTP Hashing

GTP hashing is an early access feature and open to customer feedback. This feature is not currently intended to run in production and is not supported through NVIDIA networking support.

GTP carries mobile data within the core of the mobile operator’s network. Traffic in the 5G Mobility core cluster, from cell sites to compute nodes, have the same source and destination IP address. The only way to identify individual flows is with the GTP TEID. Enabling GTP hashing adds the TEID as a hash parameter and helps the Cumulus Linux switches in the network to distribute mobile data traffic evenly across ECMP routes.

Cumulus Linux supports TEID-based ECMP hashing for:

  • GTP-U packets ingressing physical ports.
  • VXLAN encapsulated GTP-U packets terminating on egress VTEPs.

For TEID-based load balancing for traffic on a bond, see Bonding - Link Aggregation.

GTP TEID-based ECMP hashing is only applicable if the outer header egressing the port is GTP encapsulated and if the ingress packet is either a GTP-U packet or a VXLAN encapsulated GTP-U packet.

  • Cumulus Linux supports GTP Hashing on NVIDIA Spectrum-2 and later.
  • GTP-C packets are not part of GTP hashing.
  • Cumulus Linux does not provide NVUE commands to configure GTP hashing.

To enable TEID-based ECMP hashing:

  1. Edit the /etc/cumulus/datapath/traffic.conf file and change the lag_hash_config.gtp_teid parameter to true:

    cumulus@switch:~$ sudo nano /etc/cumulus/datapath/traffic.conf
    ...
    #GTP-U teid
    hash_config.gtp_teid = true
    
  2. Run the echo 1 > /cumulus/switchd/ctrl/hash_config_reload command. This command does not cause any traffic interruptions.

    cumulus@switch:~$ echo 1 > /cumulus/switchd/ctrl/hash_config_reload
    

To disable TEID-based ECMP hashing, set the hash_config.gtp_teid parameter to false, then reload the configuration.

There are no NVUE commands available to enable TEID-based ECMP hashing.

Unique Hash Seed

You can configure a unique hash seed for each switch to prevent hash polarization, a type of network congestion that occurs when multiple data flows try to reach a switch using the same switch ports.

You can set a hash seed value between 0 and 4294967295. If you do not specify a value, switchd creates a randomly generated seed.

To configure the hash seed:

Edit /etc/cumulus/datapath/traffic.conf file to change the ecmp_hash_seed parameter, then restart switchd.

cumulus@switch:~$ sudo nano /etc/cumulus/datapath/traffic.conf
...
#Specify the hash seed for Equal cost multipath entries
# and for custom ecmp and lag hash
# Default value: random
# Value Range: {0..4294967295}
ecmp_hash_seed = 50
...
cumulus@switch:~$ sudo systemctl restart switchd.service

Restarting the switchd service causes all network ports to reset, interrupting network services, in addition to resetting the switch hardware configuration.

Resilient Hashing

In Cumulus Linux, when a next hop fails or you remove the next hop from an ECMP pool, the hashing or hash bucket assignment can change. Resilient hashing is an alternate way to manage ECMP groups. Cumulus Linux assigns next hops to buckets using their hashing header fields and uses the resulting hash to index into the table of 2^n hash buckets. Because all packets in a given flow have the same header hash value, they all use the same flow bucket.

  • Resilient hashing supports both IPv4 and IPv6 routes.
  • Resilient hashing prevents disruption when you remove next hops but does not prevent disruption when you add next hops.

The NVIDIA Spectrum ASIC assigns packets to hash buckets and assigns hash buckets to next hops. The ASIC also runs a background thread that monitors buckets and can migrate buckets between next hops to rebalance the load.

  • When you remove a next hop, Cumulus Linux distributes the assigned buckets to the remaining next hops.
  • When you add a next hop, Cumulus Linux assigns no buckets to the new next hop until the background thread rebalances the load.
  • The load rebalances when the active flow timer expires only if there are inactive hash buckets available; the new next hop can remain unpopulated until the period set in active flow timer expires.
  • When the unbalanced timer expires and the load is not balanced, the thread migrates buckets to different next hops to rebalance the load.

Any flow can migrate to any next hop, depending on flow activity and load balance conditions. Over time, the flow can get pinned, which is the default setting and behavior.

When you enable resilient hashing, Cumulus Linux assigns next hops in round robin fashion to a fixed number of buckets. In this example, there are 12 buckets and four next hops.

Unlike default ECMP hashing, when you need to remove a next hop, the number of hash buckets does not change.

With 12 buckets and four next hops, instead of reducing the number of buckets, which impacts flows to known good hosts, the remaining next hops replace the failed next hop.

After you remove the failed next hop, the remaining next hops replace it. This prevents impact to any flows that hash to working next hops.

Resilient hashing does not prevent possible impact to existing flows when you add new next hops. Because there are a fixed number of buckets, a new next hop requires reassigning next hops to buckets.

As a result, some flows hash to new next hops, which can impact anycast deployments.

Cumulus Linux does not enable resilient hashing by default. When you enable resilient hashing, all ECMP groups share 65,536 buckets. An ECMP group is a list of unique next hops that multiple ECMP routes reference.

An ECMP route counts as a single route with multiple next hops.

All ECMP routes must use the same number of buckets (you cannot configure the number of buckets per ECMP route).

A larger number of ECMP buckets reduces the impact on adding new next hops to an ECMP route. However, the system supports fewer ECMP routes. If you install the maximum number of ECMP routes, new ECMP routes log an error and do not install.

You can configure route and MAC address hardware resources depending on ECMP bucket size changes. See NVIDIA Spectrum routing resources.

To enable resilient hashing:

Cumulus Linux does not provide NVUE commands for this setting.
  1. Edit the /etc/cumulus/datapath/traffic.conf file to uncomment and set the resilient_hash_enable parameter to TRUE.

    You can also set the resilient_hash_entries_ecmp parameter to the number of hash buckets to use for all ECMP routes. On Spectrum switches, you can set the number of buckets to 64, 512, 1024, 2048, or 4096. On NVIDIA Spectrum-2 and later, you can set the number of buckets to 64, 128, 256, 512, 1024, 2048, or 4096. The default value is 64.

    # Enable resilient hashing
    resilient_hash_enable = TRUE
    
    # Resilient hashing flowset entries per ECMP group
    # 
    # Mellanox Spectrum platforms:
    # Valid values - 64, 512, 1024, 2048, 4096
    #
    # Mellanox Spectrum2/3 platforms
    # Valid values -  64, 128, 256, 512, 1024, 2048, 4096
    #
    # resilient_hash_entries_ecmp = 64
    
  2. Restart the switchd service:

cumulus@switch:~$ sudo systemctl restart switchd.service

Restarting the switchd service causes all network ports to reset, interrupting network services, in addition to resetting the switch hardware configuration.

  1. Resilient hashing in hardware does not work with next hop groups; the switch remaps flows to new next hops when the set of nexthops changes. To work around this issue, configure zebra not to install next hop IDs in the kernel with the following vtysh command:
cumulus@switch:~$ sudo vtysh
switch# configure terminal
switch(config)# zebra nexthop proto only
switch(config)# exit
switch# write memory
switch# exit
cumulus@switch:~$

Adaptive Routing

Adaptive routing is an early access feature and open to customer feedback. This feature is not currently intended to run in production and is not supported through NVIDIA networking support.

Adaptive routing is a load balancing mechanism that improves network utilization by selecting routes dynamically based on the immediate network state, such as switch queue length and port utilization.

The benefits of using adaptive routing include:

  • The switch can forward RoCE traffic over all the available ECMP member ports to maximize the total traffic throughput.
  • For leaf to spine traffic flows, the switch distributes incoming traffic equally between the available spines, which helps to minimize latency and congestion on network resources.
  • If the cumulative rate of one or more RoCE traffic streams exceeds the link bandwidth of the individual uplink port, adaptive routing can distribute the traffic dynamically between multiple uplink ports; the available bandwidth for RoCE traffic is not limited to the link bandwidth of the individual uplink port.
  • If the link bandwidth of the individual uplink ports is lower than that of the ingress port, RoCE traffic can flow through; the switch distributes the traffic between the available ECMP member ports without affecting the existing traffic.

Cumulus Linux only supports adaptive routing with:

  • Switches on Spectrum-2 and later
  • RDMA with lossless RoCEv2 unicast traffic
  • Physical uplink (layer 3) ports; you cannot configure adaptive routing on subinterfaces, SVIs, bonds, or ports that are part of a bond.
  • Interfaces in the default VRF

  • Adaptive routing does not make use of resilient hashing.
  • You cannot use adaptive routing with EVPN or VXLAN.

With adaptive routing, packets are routed to the less loaded path on a per packet basis to best utilize the fabric resources and avoid congestion for the specific time duration. This mode is more time effective and restricts the port selection change decision to a predefined time.

The change decision for port selection is set to one microsecond; you cannot change it.

You must configure adaptive routing on all ports that are part of the same ECMP route. Make sure the ports are physical uplink ports.

To enable adaptive routing:

For each port on which you want to enable adaptive routing, run the nv set interface <interface> router adaptive-routing enable on command.

cumulus@switch:~$ nv set interface swp51 router adaptive-routing enable on
cumulus@switch:~$ nv config apply

When you run the above command, NVUE:

  • Enables the adaptive routing feature.
  • Sets adaptive routing on the specified port.
  • Sets the link utilization threshold percentage to the default value of 70. Adaptive routing considers the port congested based on the link utilization threshold.

To change the link utilization threshold percentage, run the nv set interface <interface> router adaptive-routing link-utilization-threshold command. You can set a value between 1 and 100.

cumulus@switch:~$ nv set interface swp51 router adaptive-routing link-utilization-threshold 100
cumulus@switch:~$ nv config apply

To disable adaptive routing globally, run the nv set router adaptive-routing enable off command. To disable adaptive routing on a port, run the nv set interface <interface> router adaptive-routing enable off command.

When you enable adaptive routing, NVUE restarts the switchd service, which causes all network ports to reset, interrupting network services, in addition to resetting the switch hardware configuration.

  1. Edit the /etc/cumulus/switchd.d/adaptive_routing.conf file:
    • Set the global adaptive_routing.enable parameter to TRUE.
    • For each port on which you want to enable adaptive routing, set the interface.<port>.adaptive_routing.enable parameter to TRUE.
    • For each port on which you want to enable adaptive routing, set the interface.<port>.adaptive_routing.link_util_thresh parameter to configure the link utilization threshold percentage (optional). Adaptive routing considers the port congested based on the link utilization threshold. You can set a value between 1 and 100. The default value is 70.
cumulus@switch:~$ sudo nano /etc/cumulus/switchd.d/adaptive_routing.conf
## Global adaptive-routing enable/disable setting 
adaptive_routing.enable = TRUE

## Supported AR profile modes : STICKY_FREE
#adaptive_routing.profile0.mode = STICKY_FREE

## Maximum value for buffer-congestion threshold is 16777216. Unit is in cells
#adaptive_routing.congestion_threshold.low = 100
#adaptive_routing.congestion_threshold.medium = 1000
#adaptive_routing.congestion_threshold.high = 10000

## Per-port configuration for adaptive-routing
interface.swp51.adaptive_routing.enable = TRUE
interface.swp51.adaptive_routing.link_util_thresh = 70
...

The /etc/cumulus/switchd.d/adaptive_routing.conf file contains the adaptive routing profile mode (STICKY_FREE) and default buffer congestion threshold settings; do not change these settings.

  1. Restart the switchd service:
cumulus@switch:~$ sudo systemctl restart switchd.service

Restarting the switchd service causes all network ports to reset, interrupting network services, in addition to resetting the switch hardware configuration.

To disable adaptive routing globally, set the adaptive_routing.enable parameter to FALSE in the /etc/cumulus/switchd.d/adaptive_routing.conf file.

To disable adaptive routing on a port, set the interface.<port>.adaptive_routing.enable parameter to FALSE in the /etc/cumulus/switchd.d/adaptive_routing.conf file.

To verify that adaptive routing is on, run the nv show router adaptive-routing command:

cumulus@leaf01:mgmt:~$ nv show router adaptive-routing
        applied  description
------  -------  ------------------------------------------------------
enable  on       Turn the feature 'on' or 'off'.  The default is 'off'.

To show adaptive routing configuration for an interface, run the nv show interface <interface> router adaptive-routing command:

cumulus@leaf01:mgmt:~$ nv show interface swp51 router adaptive-routing 
                            applied  description
--------------------------  -------  ------------------------------------------------------
enable                      on       Turn the feature 'on' or 'off'.  The default is 'off'.
link-utilization-threshold  100      Link utilization threshold percentage

cl-ecmpcalc

Run the cl-ecmpcalc command to determine a hardware hash result. For example, you can see which path a flow takes through a network. You must provide all fields in the hash, including the ingress interface, layer 3 source IP, layer 3 destination IP, layer 4 source port, and layer 4 destination port.

cl-ecmpcalc only supports input interfaces that convert to a single physical port in the port tab file, such as the physical switch ports (swp). You can not specify virtual interfaces like bridges, bonds, or subinterfaces.

cumulus@switch:~$ sudo cl-ecmpcalc -i swp1 -s 10.0.0.1 -d 10.0.0.1 -p tcp --sport 20000 --dport 80
ecmpcalc: will query hardware
swp3

If you omit a field, cl-ecmpcalc fails.

cumulus@switch:~$ sudo cl-ecmpcalc -i swp1 -s 10.0.0.1 -d 10.0.0.1 -p tcp
ecmpcalc: will query hardware
usage: cl-ecmpcalc [-h] [-v] [-p PROTOCOL] [-s SRC] [--sport SPORT] [-d DST]
                   [--dport DPORT] [--vid VID] [-i IN_INTERFACE]
                   [--sportid SPORTID] [--smodid SMODID] [-o OUT_INTERFACE]
                   [--dportid DPORTID] [--dmodid DMODID] [--hardware]
                   [--nohardware] [-hs HASHSEED]
                   [-hf HASHFIELDS [HASHFIELDS ...]]
                   [--hashfunction {crc16-ccitt,crc16-bisync}] [-e EGRESS]
                   [-c MCOUNT]
cl-ecmpcalc: error: --sport and --dport required for TCP and UDP frames

When there are multiple routes in the routing table, Cumulus Linux assigns each route to an ECMP bucket. When the ECMP hash executes, the result of the hash determines which bucket to use.

In the following example, four next hops exist. Three different flows hash to different hash buckets. Each next hop goes to a unique hash bucket.

The addition of a next hop creates a new hash bucket. The assignment of next hops to hash buckets, as well as the hash result, sometimes changes with the addition of next hops.

With the addition of a new next hop, there is a new hash bucket. As a result, the hash and hash bucket assignment changes, so the existing flows go to different next hops.

When you remove a next hop, the remaining hash bucket assignments can change, which can also change the next hop selected for an existing flow.

A next hop fails, which removes the next hop and hash bucket. It is possible that Cumulus Linux reassigns the remaining next hops.

In most cases, modifying hash buckets has no impact on traffic flows as the switch forwards traffic to a single end host. In deployments where multiple end hosts use the same IP address (anycast), you must use resilient hashing.

Considerations

When the router adds or removes ECMP paths, or when the next hop IP address, interface, or tunnel changes, the next hop information for an IPv6 prefix can change. FRR deletes the existing route to that prefix from the kernel, then adds a new route with all the relevant new information. In certain situations, Cumulus Linux does not maintain resilient hashing for IPv6 flows.

To work around this issue, you can enable IPv6 route replacement.

For certain configurations, IPv6 route replacement can lead to incorrect forwarding decisions and lost traffic. For example, it is possible for a destination to have next hops with a gateway value with the outbound interface or just the outbound interface itself, without a gateway address. If both types of next hops for the same destination exist, route replacement does not operate correctly; Cumulus Linux adds an additional route entry and next hop but does not delete the previous route entry and next hop.

To enable the IPv6 route replacement option:

  1. In the /etc/frr/daemons file, add the configuration option --v6-rr-semantics to the zebra daemon definition. For example:

    cumulus@switch:~$ sudo nano /etc/frr/daemons
    ...
    vtysh_enable=yes
    zebra_options=" -M cumulus_mlag -M snmp -A 127.0.0.1 --v6-rr-semantics -s 90000000"
    bgpd_options=" -M snmp  -A 127.0.0.1"
    ospfd_options=" -M snmp -A 127.0.0.1"
    ...
    
  1. Restart FRR with this command:

    cumulus@switch:~$ sudo systemctl restart frr.service

    Restarting FRR restarts all the routing protocol daemons that are enabled and running.

To verify that IPv6 route replacement, run the systemctl status frr command:

cumulus@switch:~$ systemctl status frr

    ● frr.service - FRRouting
      Loaded: loaded (/lib/systemd/system/frr.service; enabled; vendor preset: enabled)
      Active: active (running) since Mon 2020-02-03 20:02:33 UTC; 3min 8s ago
        Docs: https://frrouting.readthedocs.io/en/latest/setup.html
      Process: 4675 ExecStart=/usr/lib/frr/frrinit.sh start (code=exited, status=0/SUCCESS)
      Memory: 14.4M
      CGroup: /system.slice/frr.service
            ├─4685 /usr/lib/frr/watchfrr -d zebra bgpd staticd
            ├─4701 /usr/lib/frr/zebra -d -M snmp -A 127.0.0.1 --v6-rr-semantics -s 90000000
            ├─4705 /usr/lib/frr/bgpd -d -M snmp -A 127.0.0.1
            └─4711 /usr/lib/frr/staticd -d -A 127.0.0.1