NVIDIA NetQ 4.11 Release Notes

Download 4.11 Release Notes xls    Download all 4.11 release notes as .xls

4.11.0 Release Notes

Open Issues in 4.11.0

Issue IDDescriptionAffectsFixed
4001098
When you use NetQ LCM to upgrade a Cumulus Linux switch from version 5.9 to 5.10, and if the upgrade fails, NetQ rolls back to version 5.9 and reverts the cumulus user password to the default password. After rollback, reconfigure the password with the nv set system aaa user cumulus password <password> command.4.11.0-4.13.0
3995266
When you use NetQ LCM to upgrade a Cumulus Linux switch with NTP configured using NVUE in a VRF that is not mgmt, the upgrade fails to complete. To work around this issue, first unset the NTP configuration with the nv unset service ntp and nv config apply commands, and reconfigure NTP after the upgrade completes.4.11.0-4.13.0
3993243
When you upgrade your NetQ VM, RoCE validation data might not contain all RoCE-enabled switches in your network. This condition will clear within 24 hours of the NetQ upgrade.4.10.0-4.13.0
3985598
When you configure multiple threshold-crossing events for the same TCA event ID on the same device, NetQ will only display one TCA event for each hostname per TCA event ID, even if both thresholds are crossed or status events are triggered.4.11.0-4.13.0
3983871
When you run the netq install command on a VM with an IP address configured that overlaps the NetQ pod or service IP subnets 10.244.0.0/16 or 10.96.0.0/16, the install prechecks will fail but subsequent attempts to run netq install will fail even after changing the VM IP address to not conflict with these subnets. To work around this issue, run the netq bootstrap reset purge-db command and rerun the netq install command.4.11.0-4.13.0
3981655
When you upgrade your NetQ VM, some devices in the NetQ inventory might appear as rotten. To work around this issue, restart NetQ agents on devices or upgrade them to the latest agent version after the NetQ VM upgrade is completed.4.11.0-4.13.0
3858210
When you upgrade your NetQ VM, DPUs in the inventory are not shown. To work around this issue, restart the DTS container on the DPUs in your network.4.10.0-4.13.0
3854467
When a single NetQ cluster VM is offline, the NetQ kafka-connect pods are brought down on other cluster nodes, preventing NetQ data from collecting data. To work around this issue, bring all cluster nodes back into service.4.10.0-4.13.0
3847280
The netq-opta package fails to install on Cumulus Linux 5.9.0. On-switch OPTA is not supported on Cumulus Linux 5.9.0.4.10.0-4.13.0
3800434
When you upgrade NetQ from a version prior to 4.9.0, What Just Happened data that was collected before the upgrade is no longer present.4.9.0-4.13.0
3772274
After you upgrade NetQ, data from snapshots taken prior to the NetQ upgrade will contain unreliable data and should not be compared to any snapshots taken after the upgrade. In cluster deployments, snapshots from prior NetQ versions will not be visible in the UI.4.9.0-4.13.0
3771279
When an interface speed is changed in the network, NetQ might not reflect the new speed until up to an hour after the change.4.11.0-4.13.0
3769936
When there is a NetQ interface validation failure for admin state mismatch, the validation failure might clear unexpectedly while one side of the link is still administratively down.4.9.0-4.13.0
3752422
When you run a NetQ trace and specify MAC addresses for the source and destination, NetQ displays the message “No valid path to destination” and does not display trace data.4.9.0-4.13.0
3613811
LCM operations using in-band management are unsupported on switches that use eth0 connected to an out-of-band network. To work around this issue, configure NetQ to use out-of-band management in the mgmt VRF on Cumulus Linux switches when interface eth0 is in use.4.8.0-4.13.0

Fixed Issues in 4.11.0

Issue IDDescriptionAffects
4011713
When you run a duplicate address validation, NetQ might report a validation failure indicating 127.0.1.1 is duplicated on Cumulus Linux 5.10.0 switches. To suppress this validation failure, run the netq add check-filter check_filter_id addr_1 check_name addr test_name IPV4_Duplicate_Address scope ‘[{“Prefix”: “127.0.1.1”}]' CLI command, or use the NetQ UI to add duplicate address filter for address 127.0.1.1.
3948198
When you upgrade a Cumulus Linux switch configured with NVUE using NetQ LCM, the upgrade might fail due to NVUE configuration validation if the NVUE object model was changed between the current and new Cumulus Linux version. When this failure occurs, NetQ is unable to rollback to the prior configuration and the switch remains running the default Cumulus Linux configuration.4.10.1
3863195
When you perform an LCM switch discovery on a Cumulus Linux 5.9.0 switch in your network that was already added in the NetQ inventory on a prior Cumulus Linux version, the switch will appear as Rotten in the NetQ UI. To work around this issue, decommission the switch first,and run LCM discovery again after the switch is upgraded.4.10.0-4.10.1
3851922
After you run an LCM switch discovery in a NetQ cluster environment, NetQ CLI commands on switches might fail with the message Failed to process command.4.10.0-4.10.1
3721754
After you decommission a switch, the switch’s interfaces are still displayed in the NetQ UI in the Interfaces view.4.9.0-4.10.1