4621868
| NetQ might generate event notifications for BGP reset time changes even when no actual changes have occurred. | 4.14.0-4.15.1 | 5.0.0-5.1.0 |
4612457
| The process monitoring dashboard may display inaccurate CPU utilization values for the NetQ agent. | 4.11.0-4.15.1 | 5.0.0-5.1.0 |
4606694
| Switch discovery through the lifecycle management UI does not work for switch IP addresses whose last octet is 0 or 255. To work around this issue, manually add these switches to NetQ by configuring the switch to point to the OPTA IP address. | 4.15.0-4.15.1 | 5.0.0-5.1.0 |
4537675
| The NetQ UI might not display pagination controls for large tables with multiple entries. | 4.14.0-4.15.1 | 5.0.0-5.1.0 |
4532058
| When you run a validation for a past date, NetQ might display incorrect values for session counts and active links. | 4.15.0-4.15.1 | 5.0.0-5.1.0 |
4527529
| When there is a high volume of concurrent API requests to NetQ, some requests may fail. | 4.15.0-5.0.0 | 5.1.0 |
4521037
| The PTP violations summary in the UI might not render properly. To work around this issue, refresh the page in your browser. | 4.15.0-4.15.1 | 5.0.0-5.1.0 |
4131550
| When you run a topology validation, the full-screen topology validation view might not display the latest results. To work around this issue, refresh the page. | 4.12.0-4.15.1 | |
4100882
| When you attempt to export a file that is larger than 200MB, your browser might crash or otherwise prevent you from exporting the file. To work around this issue, use filters in the UI to decrease the size of the dataset that you intend to export. | 4.12.0-4.15.1, 5.0.0-5.1.0 | |
4023716
| NetQ might display duplicate validations results. | 4.11.0-4.15.1 | 5.0.0-5.1.0 |
3993538
| When you re-position a card on your workbench and then manually refresh the workbench, NetQ might reposition the cards. | 4.11.0-4.15.1 | 5.0.0-5.1.0 |
3800434
| When you upgrade NetQ from a version prior to 4.9.0, What Just Happened data that was collected before the upgrade is no longer present. | 4.9.0-4.15.1 | |
3772274
| After you upgrade NetQ, data from snapshots taken prior to the NetQ upgrade will contain unreliable data and should not be compared to any snapshots taken after the upgrade. In cluster deployments, snapshots from prior NetQ versions will not be visible in the UI. | 4.9.0-4.15.1 | |
3613811
| LCM operations using in-band management are unsupported on switches that use eth0 connected to an out-of-band network. To work around this issue, configure NetQ to use out-of-band management in the mgmt VRF on Cumulus Linux switches when interface eth0 is in use. | 4.8.0-4.15.1 | |