NVIDIA NetQ 5.0 Release Notes

Download 5.0 Release Notes xls    Download all 5.0 release notes as .xls

5.0.1 Release Notes

Open Issues in 5.0.1

Issue IDDescriptionAffectsFixed
4786996
To use lifecycle management in NMC or BCM environments, you must edit the master node IP address in the configuration manager to match the cluster’s head node IP address. Use the kubectl edit cm -n netq-eth netq-master-node-ip command to edit the configuration. In the configuration file, change the data/master_node field to the cluster’s head node IP address.5.0.0-5.0.1
4687477
When you run a validation against a group of devices with specific labels, NetQ ignores any pre-configured filters.5.0.0-5.0.1
4687241
The activity log in the UI might display multiple entries with “unknown” or “anonymous” usernames.5.0.0-5.0.1
4683830
The Cable Validation Tool might fail to load in the NetQ UI. To work around this issue, log out of NetQ and then log back in.5.0.0-5.0.1
4681581
The netq bootstrap reset purge-db command might take up to 60 minutes to complete on Base Command Manager scale deployments.5.0.0-5.0.1
4668341
When you a create an LDAP server configuration, the NetQ UI incorrectly allows you to modify the default server ports. Only the standard ports (389 for insecure and 636 for secure) are permitted.5.0.0-5.0.1
4573427
The link health view utilization chart might display incorrect values for the top 5 links when multiple links share the same value.5.0.0-5.0.1
4399074
When connecting a switch to NMX-T or NMX-C through the service registration workflow, use either the IP address or the hostname. Using both creates duplicate registrations, and the operation does not fail as expected.5.0.0-5.0.1
4100882
When you attempt to export a file that is larger than 200MB, your browser might crash or otherwise prevent you from exporting the file. To work around this issue, use filters in the UI to decrease the size of the dataset that you intend to export.4.12.0-4.15.1, 5.0.0-5.0.1

Fixed Issues in 5.0.1

Issue IDDescriptionAffects
4784336
The NetQ for NVLink deployment option is not supported in air-gapped environments.5.0.0

5.0.0 Release Notes

Open Issues in 5.0.0

Issue IDDescriptionAffectsFixed
4786996
To use lifecycle management in NMC or BCM environments, you must edit the master node IP address in the configuration manager to match the cluster’s head node IP address. Use the kubectl edit cm -n netq-eth netq-master-node-ip command to edit the configuration. In the configuration file, change the data/master_node field to the cluster’s head node IP address.5.0.0
4784336
The NetQ for NVLink deployment option is not supported in air-gapped environments.5.0.0
4693161
In cluster and scale cluster deployments, the snapshot comparison feature may time out when comparing MAC addresses.5.0.0
4687477
When you run a validation against a group of devices with specific labels, NetQ ignores any pre-configured filters.5.0.0
4687241
The activity log in the UI might display multiple entries with “unknown” or “anonymous” usernames.5.0.0
4683830
The Cable Validation Tool might fail to load in the NetQ UI. To work around this issue, log out of NetQ and then log back in.5.0.0
4681581
The netq bootstrap reset purge-db command might take up to 60 minutes to complete on Base Command Manager scale deployments.5.0.0
4668341
When you a create an LDAP server configuration, the NetQ UI incorrectly allows you to modify the default server ports. Only the standard ports (389 for insecure and 636 for secure) are permitted.5.0.0
4667571
NetQ might return inconsistent results when queries use the regular expression wildcard.5.0.0
4640757
The enhanced duplicate IP address validation does not support filters.5.0.0
4637749
When the master node is down, the netq show status command might report an incorrect status.5.0.0
4573427
The link health view utilization chart might display incorrect values for the top 5 links when multiple links share the same value.5.0.0
4399074
When connecting a switch to NMX-T or NMX-C through the service registration workflow, use either the IP address or the hostname. Using both creates duplicate registrations, and the operation does not fail as expected.5.0.0
4100882
When you attempt to export a file that is larger than 200MB, your browser might crash or otherwise prevent you from exporting the file. To work around this issue, use filters in the UI to decrease the size of the dataset that you intend to export.4.12.0-4.15.1, 5.0.0

Fixed Issues in 5.0.0

Issue IDDescriptionAffects
4621868
NetQ might generate event notifications for BGP reset time changes even when no actual changes have occurred.4.14.0-4.15.1
4612457
The process monitoring dashboard may display inaccurate CPU utilization values for the NetQ agent.4.11.0-4.15.1
4606694
Switch discovery through the lifecycle management UI does not work for switch IP addresses whose last octet is 0 or 255. To work around this issue, manually add these switches to NetQ by configuring the switch to point to the OPTA IP address.4.15.0-4.15.1
4537675
The NetQ UI might not display pagination controls for large tables with multiple entries.4.14.0-4.15.1
4532058
When you run a validation for a past date, NetQ might display incorrect values for session counts and active links.4.15.0-4.15.1
4521037
The PTP violations summary in the UI might not render properly. To work around this issue, refresh the page in your browser.4.15.0-4.15.1
3993538
When you re-position a card on your workbench and then manually refresh the workbench, NetQ might reposition the cards.4.11.0-4.15.1