Interface
The nv unset
commands remove the configuration you set with the equivalent nv set
commands. This guide only describes an nv unset
command if it differs from the nv set
command.
nv set interface <interface-id> base-interface
Configures the specified interface to be the base interface.
Command Syntax
Syntax | Description |
---|---|
<interface-id> | The interface you want to configure. |
Version History
Introduced in Cumulus Linux 5.0.0
Example
cumulus@switch:~$ nv set interface swp5 base-interface
nv set interface <interface-id> bond down-delay
Configures the down delay on the bonded interface. You can set a value between 0 and 65535.
Command Syntax
Syntax | Description |
---|---|
<interface-id> | The interface you want to configure. |
Version History
Introduced in Cumulus Linux 5.0.0
Example
cumulus@switch:~$ nv set interface bond1 bond down-delay 100
nv set interface <interface-id> bond lacp-bypass
Turns LACP bypass on the specified bond to 802.3ad mode so that it becomes active and forwards traffic even when there is no LACP partner. You can specify on or off. The default setting is off.
Command Syntax
Syntax | Description |
---|---|
<interface-id> | The interface you want to configure. |
Version History
Introduced in Cumulus Linux 5.0.0
Example
cumulus@switch:~$ nv set interface bond1 bond lacp-bypass on
nv set interface <interface-id> bond lacp-rate
Configures the rate at which the link partner transmits LACP control packets. You can set a value of fast
or slow
. The default setting is fast
.
Command Syntax
Syntax | Description |
---|---|
<interface-id> | The interface you want to configure. |
Version History
Introduced in Cumulus Linux 5.0.0
Example
cumulus@switch:~$ nv set interface bond1 bond lacp-rate slow
nv set interface <interface-id> bond member <member-id>
Configures the bonded interface by specifying the bond members.
Command Syntax
Syntax | Description |
---|---|
<interface-id> | The interface you want to configure. |
<member-id> | The bond member names. |
Version History
Introduced in Cumulus Linux 5.0.0
Example
cumulus@switch:~$ nv set interface bond1 bond member swp1-4
nv set interface <interface-id> bond mode
Configures link aggregation mode on the bond to 802.3ad or balance-xor mode. You can specify lacp
(802.3ad) or static
(balance-xor mode). The default mode is 802.3ad.
Set balance-xor mode only if you cannot use LACP; LACP can detect mismatched link attributes between bond members and can even detect misconnections.
Command Syntax
Syntax | Description |
---|---|
<interface-id> | The interface you want to configure. |
Version History
Introduced in Cumulus Linux 5.0.0
Example
cumulus@switch:~$ nv set interface swp1 bond mode static
nv set interface <interface-id> bond up-delay
Configures the up delay on the bonded interface. You can set a value between 0 and 65535.
Command Syntax
Syntax | Description |
---|---|
<interface-id> | The interface you want to configure. |
Version History
Introduced in Cumulus Linux 5.0.0
Example
cumulus@switch:~$ nv set interface swp5 bond up-delay 100
nv set interface <interface-id> description
Configures a description for the specified interface.
Command Syntax
Syntax | Description |
---|---|
<interface-id> | The interface you want to configure. |
Version History
Introduced in Cumulus Linux 5.0.0
Example
cumulus@switch:~$ nv set interface swp1 description hypervisor_port_1
nv set interface <interface-id> ip
Configures IP addressing for an interface.
nv set interface <interface-id> ip address <ip-prefix-id>
Configures an IP address with a route prefix for the specified interface.
Command Syntax
Syntax | Description |
---|---|
<interface-id> | The interface you want to configure. |
<ip-prefix-id> | The IPv4 or IPv6 address and route prefix in CIDR notation. |
Version History
Introduced in Cumulus Linux 5.0.0
Example
cumulus@switch:~$ nv set interface swp1 ip address 10.0.0.1/30
nv set interface <interface-id> ip gateway <ip-address-id>
Configures the gateway IP address on the specified interface.
Command Syntax
Syntax | Description |
---|---|
<interface-id> | The interface you want to configure. |
<ip-address-id> | The IP address. |
Version History
Introduced in Cumulus Linux 5.0.0
Example
cumulus@switch:~$ nv set interface swp1 ip gateway 10.10.10.1
nv set interface <interface-id> ip ipv4
Configures IPv4 settings for the specified interface.
nv set interface <interface-id> ip ipv4 forward
Turns IPv4 forwarding on or off for the specified interface. The default setting is off
.
Command Syntax
Syntax | Description |
---|---|
<interface-id> | The interface you want to configure. |
Version History
Introduced in Cumulus Linux 5.0.0
Example
cumulus@switch:~$ nv set interface swp1 ip ipv4 forward on
nv set interface <interface-id> ip ipv6
Configures IPv6 settings for an interface.
nv set interface <interface-id> ip ipv6 enable
Turns IPv6 on or off. The default setting is on
.
Command Syntax
Syntax | Description |
---|---|
<interface-id> | The interface you want to configure. |
Version History
Introduced in Cumulus Linux 5.0.0
Example
cumulus@switch:~$ nv set interface swp1 ip ipv6 enable off
nv set interface <interface-id> ip ipv6 forward
Turns IPv6 forwarding on or off. The default setting is on
.
Command Syntax
Syntax | Description |
---|---|
<interface-id> | The interface you want to configure. |
Version History
Introduced in Cumulus Linux 5.0.0
Example
cumulus@switch:~$ nv set interface swp1 ip ipv6 forward off
nv set interface <interface-id> link
Provides commands to configure physical interface settings, such as the link state, auto-negotiation, breakouts, FEC, MTU, speed, 802.1X, and MAC authentication bypass (MAB).
nv set interface <interface-id> link auto-negotiate
Configures auto-negotiation for the interface.
The default setting is on
.
Command Syntax
Syntax | Description |
---|---|
<interface-id> | The interface you want to configure. |
Version History
Introduced in Cumulus Linux 5.0.0
Example
cumulus@switch:~$ nv set interface swp1 link auto-negotiate off
nv set interface <interface-id> link breakout <mode-id>
Configures a port break out (split) with the following options:
- 1x does not split the port. This is the default port setting.
- 2x splits the port into two interfaces.
- 4x splits the port into four interfaces.
- 8x splits the port into eight interfaces.
If you split a 100G port into four interfaces and auto-negotiation is on (the default setting), Cumulus Linux advertises the speed for each interface up to the maximum speed possible for a 100G port (100/4=25G). You can override this configuration and set specific speeds for the split ports if necessary.
Command Syntax
Syntax | Description |
---|---|
<interface-id> | The interface you want to configure. |
<mode-id> | The breakout mode: 1x, 2x, 4x, 8x. |
Version History
Introduced in Cumulus Linux 5.4.0
Example
cumulus@switch:~$ nv set interface swp1 link breakout 4x
nv set interface <interface-id> link breakout <mode-id> lanes-per-port <lanes-per-port>
Configures the number of lanes per split port. By default, to calculate the split port width, Cumulus Linux uses the formula: split port width = full port width / breakout. For example, a port split into two interfaces (2x breakout) = 8 lanes width / 2x breakout = 4 lanes per split port. If you need to use a different port width than the default, you can set the number of lanes per port.
Command Syntax
Syntax | Description |
---|---|
<interface-id> | The interface you want to configure. |
<mode-id> | The breakout mode: 1x, 2x, 4x, 8x. |
<lanes-per-port> | The breakout mode: 1x, 2x, 4x, 8x. |
Version History
Introduced in Cumulus Linux 5.4.0
Example
cumulus@switch:~$ nv set interface swp1 link breakout 2x lanes-per-port 2
nv set interface <interface-id> link duplex
Configures duplex mode for the interface; full or half.
The default setting is full
.
Command Syntax
Syntax | Description |
---|---|
<interface-id> | The interface you want to configure. |
Version History
Introduced in Cumulus Linux 5.0.0
Example
cumulus@switch:~$ nv set interface swp1 link duplex half
nv set interface <interface-id> link fast-linkup
Configures fast linkup on interfaces on NVIDIA Spectrum 1 switches. Fast linkup enables you to bring up ports with cards that require links to come up fast, such as certain 100G optical network interface cards. You can specify on
or off
. The default setting is off
.
Command Syntax
Syntax | Description |
---|---|
<interface-id> | The interface you want to configure. |
Version History
Introduced in Cumulus Linux 5.3.0
Example
cumulus@switch:~$ nv set interface swp1 link fast-linkup on
nv set interface <interface-id> link fec
Configures Forward Error Correction (FEC) for the interface. FEC enables the switch to detect and correct bit errors introduced over the cable between two interfaces. The default setting is auto
.
Command Syntax
Syntax | Description |
---|---|
<interface-id> | The interface you want to configure. |
Version History
Introduced in Cumulus Linux 5.0.0
Example
cumulus@switch:~$ nv set interface swp1 link fec baser
nv set interface <interface-id> link flap-protection enable
Enable (on
) and disables (off
) link flap protection on the specified interface. Cumulus Linux enables link flap detection by default. Link flap detection triggers when there are five link flaps within ten seconds, at which point the interface goes into a protodown state and shows linkflap
as the reason. The switchd
service also shows a log message.
Command Syntax
Syntax | Description |
---|---|
<interface-id> | The interface you want to configure. |
Version History
Introduced in Cumulus Linux 5.7.0
Example
cumulus@switch:~$ nv set interface swp1 link flap-protection enable off
nv set interface <interface-id> link lanes
Configures the number of lanes for a port to override the default behavior for supported speeds and platforms.
Command Syntax
Syntax | Description |
---|---|
<interface-id> | The interface you want to configure. |
Version History
Introduced in Cumulus Linux 5.4.0
Example
cumulus@switch:~$ nv set interface swp1 link lanes 1
nv set interface <interface-id> link mac-address <mac-address>
Configures a MAC address for the specified interface.
Command Syntax
Syntax | Description |
---|---|
<interface-id> | The interface you want to configure. |
<mac-address> | The MAC address you want to configure for the interface. |
Version History
Introduced in Cumulus Linux 5.10.0
Example
cumulus@switch:~$ nv set interface swp1 link mac-address 00:02:00:00:00:05
nv set interface <interface-id> link mtu
Configures the maximum transmission unit (MTU) for the interface. You can set a value between 552 and 9216. The default setting is 9216.
Command Syntax
Syntax | Description |
---|---|
<interface-id> | The interface you want to configure. |
Version History
Introduced in Cumulus Linux 5.0.0
Example
cumulus@switch:~$ nv set interface swp1 link mtu 1500
nv set interface <interface-id> link speed
Configures the speed for the interface.
Command Syntax
Syntax | Description |
---|---|
<interface-id> | The interface you want to configure. |
Version History
Introduced in Cumulus Linux 5.0.0
Example
cumulus@switch:~$ nv set interface swp1 link speed 10G
nv set interface <interface-id> link state
Brings an interface up or down administratively (admin up or admin down). You can specify up
or down
.
Command Syntax
Syntax | Description |
---|---|
<interface-id> | The interface you want to configure. |
Version History
Introduced in Cumulus Linux 5.0.0
Example
cumulus@switch:~$ nv set interface swp1 link state up
nv set interface <interface-id> storm-control
Configures storm control on the specified interface. Storm control provides protection against excessive inbound BUM (broadcast, unknown unicast, multicast) traffic on layer 2 switch port interfaces, which can cause poor network performance.
nv set interface <interface-id> storm-control broadcast
Configures the number of broadcast packets per second (pps) that signifies a broadcast storm. You can set a value between 1 and 4294967295.
Command Syntax
Syntax | Description |
---|---|
<interface-id> | The interface you want to configure. |
Version History
Introduced in Cumulus Linux 5.0.0
Example
cumulus@switch:~$ nv set interface swp1 storm-control broadcast 400
nv set interface <interface-id> storm-control multicast
Configures the number of multicast packets per second (pps) that signifies a multicast storm. You can set a value between 1 and 4294967295.
Command Syntax
Syntax | Description |
---|---|
<interface-id> | The interface you want to configure. |
Version History
Introduced in Cumulus Linux 5.0.0
Example
cumulus@switch:~$ nv set interface swp1 storm-control multicast 3000
nv set interface <interface-id> storm-control unknown-unicast
Configures the number of unknown unicast packets per second (pps) that signifies an unknown unicast storm. You can set a value between 1 and 4294967295.
Command Syntax
Syntax | Description |
---|---|
<interface-id> | The interface you want to configure. |
Version History
Introduced in Cumulus Linux 5.0.0
Example
cumulus@switch:~$ nv set interface swp1 storm-control unknown-unicast 2000
nv set interface <interface-id> tunnel
Configures GRE tunneling.
nv set interface <interface-id> tunnel dest-ip
Configures the destination IP address for the GRE tunnel on the specified interface.
Command Syntax
Syntax | Description |
---|---|
<interface-id> | The interface you want to configure. |
Version History
Introduced in Cumulus Linux 5.1.0
Example
cumulus@switch:~$ nv set interface tunnelR2 tunnel dest-ip 10.10.10.3
nv set interface <interface-id> tunnel interface <interface-name>
Configures the GRE tunnel interface name.
Version History
Introduced in Cumulus Linux 5.1.0
Example
cumulus@switch:~$ nv set interface tunnelR2 tunnel interface MYGRETUNNEL
nv set interface <interface-id> tunnel mode gre
Enables GRE mode for the specified interface.
Command Syntax
Syntax | Description |
---|---|
<interface-id> | The interface you want to configure. |
Version History
Introduced in Cumulus Linux 5.1.0
Example
cumulus@switch:~$ nv set interface tunnelR2 tunnel mode gre
nv set interface <interface-id> tunnel source-ip
Configures the source IP address for the GRE tunnel on the specified interface.
Command Syntax
Syntax | Description |
---|---|
<interface-id> | The interface you want to configure. |
Version History
Introduced in Cumulus Linux 5.1.0
Example
cumulus@switch:~$ nv set interface tunnelR2 tunnel source-ip 10.10.10.1
nv set interface <interface-id> tunnel ttl
Configures the TTL for the GRE tunnel on the specified interface. You can set a value between 1 and 255.
Command Syntax
Syntax | Description |
---|---|
<interface-id> | The interface you want to configure. |
Version History
Introduced in Cumulus Linux 5.1.0
Example
cumulus@switch:~$ nv set interface tunnelR2 tunnel ttl 50
nv set interface <interface-id> type
Configures the interface type. The type can be swp
, eth
, bond
, loopback
, svi
, sub
, peerlink
, tunnel
, bridge
or vrf
.
Command Syntax
Syntax | Description |
---|---|
<interface-id> | The interface you want to configure. |
Version History
Introduced in Cumulus Linux 5.0.0
Example
cumulus@switch:~$ nv set interface swp1 type swp
nv set interface <interface-id> vlan
Configures the VLAN on the interface.
Command Syntax
Syntax | Description |
---|---|
<interface-id> | The interface you want to configure. |
Version History
Introduced in Cumulus Linux 5.0.0
Example
cumulus@switch:~$ nv set interface swp1 vlan 10
nv set system link flap-protection interval
Configures the duration in seconds during which a link must flap the number of times set in the link flap threshold before link flap protection triggers. You can specify a value between 0 (off) and 60. The default setting is 10.
Cumulus Linux enables link flap detection by default. By default, link flap detection triggers when there are five link flaps within ten seconds, at which point the interface goes into a protodown state and shows link flap as the reason. The switchd
service also shows a log message.
Command Syntax
Syntax | Description |
---|---|
<interface-id> | The interface you want to configure. |
Version History
Introduced in Cumulus Linux 5.7.0
Example
cumulus@switch:~$ nv set interface swp1 link flap-protection interval 30
nv set system link flap-protection threshold 0-30
Configures the number of times the link can flap within the link flap window before link flap protection triggers. You can specify a value between 0 (off) and 30. The default setting is 5.
Cumulus Linux enables link flap detection by default. By default, link flap detection triggers when there are five link flaps within ten seconds, at which point the interface goes into a protodown state and shows link flap as the reason. The switchd
service also shows a log message.
Command Syntax
Syntax | Description |
---|---|
<interface-id> | The interface you want to configure. |
Version History
Introduced in Cumulus Linux 5.7.0
Example
cumulus@switch:~$ nv set interface swp1 link flap-protection threshold 8
nv set vrf <vrf-id> loopback
Configures the loopback address in the specified VRF.
nv set vrf <vrf-id> loopback ip
Configures the loopback in the specified VRF.
nv set vrf <vrf-id> loopback ip address <ip-prefix-id>
Configures the loopback IP address in the specified VRF.
For the default VRF, use the nv set interface lo ip address <ip-prefix-id>
command.
Command Syntax
Syntax | Description |
---|---|
<vrf-id> | The VRF name. |
<ip-prefix-id> | The IPv4 or IPv6 address and route prefix in CIDR notation. |
Version History
Introduced in Cumulus Linux 5.0.0
Example
cumulus@switch:~$ nv set vrf RED loopback ip address 10.10.10.1/32