# Tutorial: Integrating Node Problem Detector

This tutorial installs Kubernetes
[node-problem-detector (NPD)](https://github.com/kubernetes/node-problem-detector),
configures NVSentinel to watch selected NPD Node Conditions, and validates the
integration.

By the end you will have:

- NPD running on each Linux node and monitoring kernel messages.
- Kubernetes Object Monitor (KOM) watching the opt-in `XfsShutdown`,
  `CperHardwareErrorFatal`, and `ReadonlyFilesystem` NPD conditions.
- A safe procedure for validating NPD detection and KOM publication.
- A pattern for monitoring additional Node Conditions from a custom NPD
  configuration.

> **Who is this for?** Cluster administrators who run NVSentinel and want to
> consume permanent Node Conditions produced by NPD.

> **Just want the AI to do it?** Jump to
> [Appendix: One-shot AI prompt](#appendix-one-shot-ai-prompt).

> **Safety:** The opt-in NPD policies recommend `REPLACE_VM`. Validate them
> only in a non-production cluster or while downstream quarantine and
> remediation components are disabled. Inject test messages only on a
> disposable node with no running jobs.

## Prerequisites

- Kubernetes 1.25 or later
- Helm 3 and `kubectl`.
- Cluster-admin access to install a privileged DaemonSet and patch Node status.
- Shell or SSH access to at least one disposable Linux node for end-to-end
  validation.
- An NVSentinel release that contains the NPD KOM policies.

See the [NVSentinel Helm chart guide](../../distros/kubernetes/README.md) for
the complete NVSentinel prerequisites.

---

## 1. Understand the integration

NPD detects a host problem and publishes a permanent condition in
`Node.status.conditions`. KOM watches the Node and publishes a fatal
NVSentinel `HealthEvent` when the condition type, status, and reason match a
configured policy.

```mermaid
flowchart LR
    HostLog["Host kernel log"] --> NPD["Node Problem Detector"]
    NPD -->|"Node Condition"| API["Kubernetes API"]
    API --> KOM["Kubernetes Object Monitor"]
    KOM -->|"HealthEvent"| PC["Platform Connector"]
```

This integration watches these condition and reason pairs:

| Condition type | Problem reason | KOM policy | Action |
| --- | --- | --- | --- |
| `XfsShutdown` | `XfsHasShutdown` | `NPDXfsShutdown` | `REPLACE_VM` |
| `CperHardwareErrorFatal` | `CperHardwareErrorFatal` | `NPDCperHardwareErrorFatal` | `REPLACE_VM` |
| `ReadonlyFilesystem` | `FilesystemIsReadOnly` | `NPDReadonlyFilesystem` | `REPLACE_VM` |

These three policies are provided in a separate opt-in overlay because their
conditions are enabled by default in the upstream NPD configuration and have
approved NVSentinel actions. KOM is not limited to these conditions. If a
custom NPD configuration publishes another permanent Node Condition, add a KOM
policy for its condition type, status, and reason as shown in
[Configure a custom NPD Node Condition](#configure-a-custom-npd-node-condition).

For the design rationale and limitations, see
[ADR-053](../designs/053-npd-checks-integration.md).

---

## 2. Install NPD if not already present

The following instructions cover deploying NPD as a Kubernetes DaemonSet. If
your cloud provider already runs NPD as a DaemonSet or host service, use the
provider's documentation for installation and upgrade instructions. Do not
deploy a second copy because multiple NPD instances can compete to own the same
Node Conditions.

Check for a Kubernetes installation:

```bash
kubectl get daemonsets,pods --all-namespaces | grep node-problem-detector
# Expected when NPD is installed:
# <namespace>   daemonset.apps/<daemonset-name>   <desired>   <current>   <ready>   ...
# <namespace>   pod/<pod-name>                    1/1         Running     ...
```

If NPD is already installed, do not install another instance. Provider-supplied
configurations can differ from upstream defaults, so confirm that the existing
installation defines all three condition and reason pairs listed above.

If NPD is not installed, follow the upstream
[NPD installation guide](https://github.com/kubernetes/node-problem-detector#installation)
for the installation method appropriate to your cluster. NVSentinel does not
install, configure, or manage NPD.

Before continuing, confirm that the NPD installation:

- runs on every node that NVSentinel should monitor;
- loads the upstream `kernel-monitor.json` and `readonly-monitor.json`
  definitions;

For a DaemonSet installation, use the namespace and DaemonSet name shown by
the check above or selected during installation. Derive its pod selector, check
that its desired and ready counts match, and list the nodes running its pods:

```bash
NPD_NAMESPACE="<npd-namespace>"
NPD_DAEMONSET="<npd-daemonset-name>"

NPD_SELECTOR=$(kubectl get daemonset "$NPD_DAEMONSET" \
  --namespace "$NPD_NAMESPACE" \
  -o go-template='{{range $key, $value := .spec.selector.matchLabels}}{{printf "%s=%s," $key $value}}{{end}}')
NPD_SELECTOR=${NPD_SELECTOR%,}

kubectl get daemonset "$NPD_DAEMONSET" \
  --namespace "$NPD_NAMESPACE" \
  -o custom-columns=DESIRED:.status.desiredNumberScheduled,READY:.status.numberReady
# Expected:
# DESIRED   READY
# <eligible-node-count>   <same-count>

kubectl get pods --namespace "$NPD_NAMESPACE" \
  --selector "$NPD_SELECTOR" \
  -o 'custom-columns=NAME:.metadata.name,NODE:.spec.nodeName,READY:.status.containerStatuses[0].ready'
# Expected: one row per eligible node, with READY=true
# NAME                         NODE          READY
# node-problem-detector-<id>   <node-name>   true
```
---

## 3. Configure NVSentinel and KOM policies

NPD policies are intentionally excluded from the default KOM values because
NVSentinel does not install NPD or control how an operator handles its
conditions. The repository provides an explicit
[NPD remediation overlay](../../distros/kubernetes/nvsentinel/values-npd-remediation.yaml)
for clusters where NVSentinel should own these conditions.

Download or copy `values-npd-remediation.yaml` and use it as the values file.
It enables KOM, retains the default `ReplaceNotReadyNode` policy, and adds the three
supported NPD policies.

### Configure a custom NPD Node Condition

NPD can publish additional permanent Node Conditions from custom monitor
configurations. Once NPD publishes a condition, add a matching policy to the
existing `kubernetes-object-monitor.policies` list in your copy of
`values-npd-remediation.yaml`.

For example, suppose a custom NPD monitor publishes:

```yaml
type: FileSystemErr
status: "True"
reason: FileSystemError
```

Add this policy to the existing list:

```yaml
- name: NPDFileSystemErr
  enabled: true
  resource:
    group: ""
    version: v1
    kind: Node
  predicate:
    expression: |
      resource.status.conditions.exists(c,
        c.type == "FileSystemErr" &&
        c.status == "True" &&
        c.reason == "FileSystemError")
  healthEvent:
    componentClass: Node
    isFatal: true
    message: "A NPD monitor reported the filesystem error"
    recommendedAction: CONTACT_SUPPORT
    errorCode:
      - NPD_FILESYSTEM_ERR
```

For custom condition policies:

- Use a stable, unique policy name; it becomes the HealthEvent `checkName`.
- Match the exact condition type and reason emitted by the custom NPD monitor.
- Assign a unique error code and validate the policy in a non-production
  cluster before enabling downstream remediation.
- Have NPD set the same condition to `False` only after recovery is validated.

See [KOM policy configuration](/nvsentinel/configuration/kubernetes-object-monitor)
for more CEL expression examples.

### Install or upgrade NVSentinel

Use one command for both installation and upgrade. For an existing release,
`--reuse-values` preserves its current user-supplied values before applying the
NPD overlay. For a new release, Helm has no previous values to reuse and
installs from the chart defaults plus the overlay.

```bash
NVSENTINEL_VERSION="<release-containing-the-NPD-policies>"

helm upgrade --install nvsentinel oci://ghcr.io/nvidia/nvsentinel \
  --version "$NVSENTINEL_VERSION" \
  --namespace nvsentinel \
  --create-namespace \
  --reuse-values \
  --values values-npd-remediation.yaml \
  --wait
```

Verify KOM:

```bash
kubectl rollout status deployment/kubernetes-object-monitor \
  --namespace nvsentinel \
  --timeout=5m
# Expected:
# deployment "kubernetes-object-monitor" successfully rolled out
```

---

## 4. Validate the integration

Validate NPD and KOM end to end by injecting a synthetic kernel message. This
publishes a synthetic fatal HealthEvent, so confirm that this is a
non-production cluster or that downstream quarantine, drain, and remediation
components are disabled.

The upstream NPD
[Try It Out guide](https://github.com/kubernetes/node-problem-detector#try-it-out)
documents injecting synthetic messages into the kernel message stream when
testing rules. This does not damage the filesystem or hardware, but it creates
real NPD conditions. Run only one test at a time.

Choose a disposable node:

```bash
NODE="<node-name>"
```

SSH to `$NODE` and inject one of these messages:

```bash
# XfsShutdown
sudo sh -c \
  "echo 'kernel: XFS (test): Shutting down filesystem' >> /dev/kmsg"

# CperHardwareErrorFatal
sudo sh -c \
  "echo 'kernel: mce: [Hardware Error]: event severity: fatal' >> /dev/kmsg"

# ReadonlyFilesystem
sudo sh -c \
  "echo 'kernel: EXT4-fs (test): Remounting filesystem read-only' >> /dev/kmsg"
```

From your workstation, inspect the resulting source conditions:

```bash
kubectl get node "$NODE" \
  -o jsonpath='{range .status.conditions[*]}{.type}={.status}{" reason="}{.reason}{"\n"}{end}' |
  grep -E '^(XfsShutdown|CperHardwareErrorFatal|ReadonlyFilesystem)='
# Expected for the messages that were injected:
# XfsShutdown=True reason=XfsHasShutdown
# CperHardwareErrorFatal=True reason=CperHardwareErrorFatal
# ReadonlyFilesystem=True reason=FilesystemIsReadOnly
```

Confirm that KOM published each matched policy and platform-connector applied
the resulting NVSentinel Node Condition:

```bash
kubectl get node "$NODE" \
  -o jsonpath='{range .status.conditions[*]}{.type}={.status}{" reason="}{.reason}{"\n"}{end}' |
  grep -E '^(NPDXfsShutdown|NPDCperHardwareErrorFatal|NPDReadonlyFilesystem)='
# Expected for the messages that were injected:
# NPDXfsShutdown=True reason=NPDXfsShutdownIsNotHealthy
# NPDCperHardwareErrorFatal=True reason=NPDCperHardwareErrorFatalIsNotHealthy
# NPDReadonlyFilesystem=True reason=NPDReadonlyFilesystemIsNotHealthy
```

> **Note:** If the downstream remediation components are enabled, each matched
> fatal policy should also cause the affected node to be cordoned. Because
> these policies recommend `REPLACE_VM`, fault-remediation should create a
> `TerminateNode` remediation custom resource for the node.

`SystemLogMonitor` permanent conditions are latched. Injected messages remain
eligible during the default five-minute lookback, so wait at least five minutes
after the final injection before restarting NPD. Do not restart the DaemonSet:
that restarts NPD on every eligible node and resets all process-owned
conditions. Delete only the NPD pod scheduled on the tested node, then wait for
its replacement. Reuse `NPD_NAMESPACE` and `NPD_SELECTOR` from step 2:

```bash
NPD_POD=$(kubectl get pods \
  --namespace "$NPD_NAMESPACE" \
  --selector "$NPD_SELECTOR" \
  --field-selector "spec.nodeName=$NODE" \
  -o jsonpath='{.items[0].metadata.name}')

kubectl delete pod "$NPD_POD" --namespace "$NPD_NAMESPACE"
# Expected:
# pod "<old-npd-pod>" deleted

kubectl wait --for=create pod \
  --namespace "$NPD_NAMESPACE" \
  --selector "$NPD_SELECTOR" \
  --field-selector "spec.nodeName=$NODE" \
  --timeout=2m
# Expected:
# pod/<new-npd-pod> created
```

A `False` condition after restart only shows that the NPD process reset its
state; it does not prove recovery from a real failure. Restarting NPD can also
cause KOM to observe a healthy transition and cancel active break-fix
processing, so limit this procedure to the test node after validation.

---

## Troubleshooting

### NPD does not publish the source condition

- Confirm `/dev/kmsg` is mounted in the NPD pod.
- Confirm the process loads `kernel-monitor.json` and
  `readonly-monitor.json`.
- Confirm the injected message contains the `kernel: ` prefix and exactly
  matches the expected capitalization.

```bash
kubectl logs "daemonset/$NPD_DAEMONSET" --namespace "$NPD_NAMESPACE"
# Expected when healthy: NPD starts without monitor configuration or
# /dev/kmsg access errors.
```

### KOM does not publish a HealthEvent

- Confirm `global.kubernetesObjectMonitor.enabled: true`.
- Confirm the relevant policy has `enabled: true`.
- Compare the Node Condition type, status, and reason with the CEL predicate.

```bash
kubectl logs deployment/kubernetes-object-monitor --namespace nvsentinel
# Expected when healthy: "Loaded policy configuration",
# "Registered controller", and "Starting manager" entries.
```

### A source condition remains `True`

This is expected for permanent conditions produced by `SystemLogMonitor`.
Validate remediation, allow the monitor lookback window to expire, and then
restart NPD. Never use an NPD restart alone as proof that the host recovered.

---

## Appendix: One-shot AI prompt

Paste this prompt into an AI coding agent with access to your NVSentinel
checkout. Replace the bracketed values before running it.

```text
Help me integrate Kubernetes node-problem-detector (NPD) with NVSentinel in this cluster:

- Kubernetes context: [context]
- Existing NPD installation: [provider-managed, DaemonSet, or not installed]
- NPD namespace: [namespace, if known]
- NPD DaemonSet: [name, if known]
- NVSentinel version: [version]
- Validation node: [node]
- Downstream remediation enabled: [yes or no]

Follow these requirements:

1. Inspect before changing anything.
   - Check whether NPD already runs as a DaemonSet.
   - If the provider manages NPD as a DaemonSet or host service, do not install
     another copy. Tell me to use the provider's install and upgrade procedure.
   - If NPD is absent, install it by following the upstream installation guide:
     https://github.com/kubernetes/node-problem-detector#installation
   - For a DaemonSet, use its actual namespace, name, and
     .spec.selector.matchLabels. Confirm desired and ready counts match and
     that one ready pod runs on every eligible node.

2. Verify the healthy NPD baseline before fault injection:
   - XfsShutdown=False, reason XfsHasNotShutDown
   - CperHardwareErrorFatal=False, reason CperHardwareHasNoFatalError
   - ReadonlyFilesystem=False, reason FilesystemIsNotReadOnly
   Confirm that the NPD installation loads upstream kernel-monitor.json and
   readonly-monitor.json definitions and can read the host kernel log. Verify
   the corresponding True status and problem reason only after injecting its
   synthetic matching message in step 5.

3. Configure NVSentinel.
   - Start from
     distros/kubernetes/nvsentinel/values-npd-remediation.yaml.
   - Preserve every existing KOM policy that the cluster needs. Helm replaces
     the complete policies list, so merge existing custom policies into this
     file before installation or upgrade.
   - Use one `helm upgrade --install` command with --reuse-values and the NPD
     values file.
   - Wait for deployment/kubernetes-object-monitor to roll out.

4. Optionally add a custom NPD Node Condition policy when I provide a condition
   type, problem reason, policy name, fatality, action, message, and error code.
   The CEL predicate must match the exact condition type, status "True", and
   reason. Add it to the existing policies list rather than creating a second
   list.

5. Validate end to end only after confirming the node is disposable and either
   the cluster is non-production or downstream remediation is disabled.
   - Follow the upstream NPD synthetic-kernel-message testing method.
   - Inject only one matching /dev/kmsg message at a time on the selected node.
   - Confirm the matching problem condition:
     XfsShutdown=True with reason XfsHasShutdown,
     CperHardwareErrorFatal=True with reason CperHardwareErrorFatal, or
     ReadonlyFilesystem=True with reason FilesystemIsReadOnly.
   - Confirm the matching NVSentinel Node Condition is True:
     NPDXfsShutdown, NPDCperHardwareErrorFatal, or NPDReadonlyFilesystem.
   - If remediation is intentionally enabled, also confirm that the node is
     cordoned and a TerminateNode resource is created for REPLACE_VM.

6. Clean up safely.
   - Wait for NPD's five-minute startup lookback to expire.
   - Never restart the entire NPD DaemonSet.
   - Select only the NPD pod scheduled on the validation node, delete it, and
     wait for its replacement.
   - Explain that restarting NPD resets process-owned permanent conditions and
     does not prove that a real fault recovered.

Show each command before executing it. Do not run Helm, kubectl mutation, SSH,
or kernel-message injection commands until I confirm the Kubernetes context,
target node, and remediation safety.
```