Disaggregated Serving
Disaggregated serving separates the two phases of LLM inference into their own worker pools so you can scale, size, and place them independently:
In an aggregated deployment, one worker does both phases. In a disaggregated deployment, prefill and decode are separate pools on separate GPUs: Dynamo routes each request through prefill first, transfers the KV cache to the decode worker, then streams the response from decode.
Structurally, that difference is one worker versus two. The rest of the
DynamoGraphDeployment (DGD) is the same:
Aggregated (1 worker)
Disaggregated (prefill + decode)
This guide walks through writing the disaggregated spec end to end. If you have not authored a DGD before, read the Deploy with DGD guide first — this page assumes you know the overall shape and focuses on what disaggregation adds.
Should you disaggregate?
Disaggregation helps most when prefill and decode need different resource shapes:
- long prompts or retrieval-heavy traffic make prefill expensive
- long generations or high concurrency make decode the bottleneck
- you want to scale prefill and decode replicas independently
- large models need different parallelism for prompt processing and generation
It is not automatically better. For small models, short prompts, low concurrency, or clusters without a fast KV-transfer fabric, an aggregated deployment is simpler and often faster. Use Sizing with AIConfigurator to compare aggregated vs. disaggregated layouts before committing.
This guide uses a single-node, multi-GPU example — prefill and decode run on separate GPUs in the same node (for instance, a node with 8×H100 serving Qwen3-32B, one GPU per worker). Each worker runs in its own pod. By default, Kubernetes isolation stops the KV cache from moving over NVLink between two pods, even on the same node, so the transfer uses RDMA if the pods request it and TCP otherwise. The Enable KV transfer step explains why, and Use NVLink between pods on one node describes the opt-in. Scaling prefill and decode across multiple nodes adds RDMA networking; see Enable multi-node transfer at the end.
Write the deployment
Check prerequisites
For the single-node example in this guide you need:
- A node with multiple GPUs — one per prefill and decode worker (this
example uses 8×H100 with
gpu: "1"per worker). - ETCD and NATS deployed for Dynamo coordination.
- A HuggingFace token secret (
hf-token-secret) if the model is gated.
Model caching (the PVC and HF_HOME wiring the workers mount) is configured
separately — see Model caching. This
guide omits those fields for clarity; without them the model downloads to the
container’s default cache.
Scaling across multiple nodes additionally requires an RDMA-capable network and device plugin — covered in Enable multi-node transfer.
Start the spec: the frontend
Begin with the DGD skeleton — just a frontend. This is identical to an aggregated deployment; nothing about disaggregation changes it.
Add the prefill worker
The prefill worker runs the prompt phase. Two things make it a prefill worker rather than a plain worker:
subComponentType: prefilltags the role for the operator and router.--disaggregation-mode prefilltells the engine to stop after producing the KV cache instead of generating tokens.
Qwen3-32B fits on a single H100, so each worker takes gpu: "1" with no tensor
parallelism. replicas: 3 gives three prefill workers; size the count for your
prompt load independently of decode. (sharedMemory is explained in the KV
transfer step.)
Add the decode worker
The decode worker continues generation after prefill hands off the KV cache. It
mirrors the prefill worker with subComponentType: decode and
--disaggregation-mode decode, and its replica count is sized for concurrency
rather than prompt load.
Prefill and decode workers must pass the same --model (and, if you set
them, the same dtype, block size, and KV layout). A mismatch means the KV cache
prefill produces cannot be consumed by decode — you get transfer errors or
silently corrupt output.
Enable KV transfer
Because prefill and decode run on different GPUs, the KV cache prefill produces has to be copied into the decode worker’s GPU memory before decode can generate. Dynamo’s transfer layer, NIXL, does this automatically, and with its UCX backend, UCX picks the transport.
UCX moves the cache GPU-to-GPU over NVLink with CUDA IPC only when both of these hold for the two worker processes:
- They share a PID namespace. Starting with UCX 1.23 (openucx/ucx#11514), UCX treats CUDA IPC as unreachable across PID namespaces unless both GPUs support fabric handles (IMEX). HGX systems such as 8×H100 nodes do not have them.
- The importing process can see the peer GPU. With the default one GPU per pod, opening the peer’s CUDA IPC handle fails.
Default worker pods meet neither condition, even when they run on the same
node. UCX then uses RDMA if the pods request RDMA devices, and TCP otherwise.
NIXL logs no error when this happens. TCP is slow enough that transfers of long
prompts can exceed the engine’s KV transfer timeout, and requests fail. Setting
UCX_TLS does not change this. To get NVLink between pods, see
Use NVLink between pods on one node. To
check which transport a deployment uses, see the next step.
The field you always set is shared memory, already in the worker specs above:
With these fields the KV transfer works: two workers tagged prefill/decode,
matching --model, and enough shared memory for NIXL. The transport it uses
depends on the pod settings described above.
Apply and verify the transfer path
Apply the assembled spec:
Then confirm NIXL initialized its transfer backend — the key check for a disaggregated deployment. Grep a prefill worker’s logs:
You want to see NIXL bring up a backend, for example:
If NIXL fails to initialize, the usual cause is sharedMemory.size left at the
default. Symptoms of a broken transfer path include high TTFT despite free
prefill capacity, decode workers sitting idle while prefill is busy, or
disaggregated throughput falling below your aggregated baseline.
This check does not show which transport UCX chose. To see it, add
UCX_PROTO_INFO=y to the env of both workers, send a request, and read the
protocol lines in the decode worker’s log:
For a GPU-to-GPU KV read, cuda_ipc means CUDA IPC, an RDMA device such as
rc_mlx5 means RDMA, and tcp means the transfer goes over TCP. CUDA IPC uses
NVLink only when the two GPUs are connected by NVLink; otherwise it goes over
PCIe. To check, run nvidia-smi topo -m on the node: NV# between the two
GPUs means NVLink. For example, with vLLM, two default pods on one node show
this line for the KV read:
Remove UCX_PROTO_INFO after the check; it adds log output for every new
connection.
Enable multi-node transfer
Everything above keeps prefill and decode on one node. When a worker’s parallelism exceeds the GPUs on a node, or you want prefill and decode pools on separate machines, the KV cache travels over the network, and that path needs RDMA (InfiniBand or RoCE). Systems with multi-node NVLink, such as GB200 or GB300 racks with IMEX, can instead move the KV cache over NVLink between nodes in one NVLink domain; that setup is not covered here. Without either, transfers fall back to TCP and KV movement can dominate TTFT and throughput. The same RDMA setup also serves separate pods on one node when you do not use the NVLink opt-in.
Multi-node adds RDMA fields to each worker (rdma/ib resource requests, the
IPC_LOCK capability, and UCX_* transport env vars) plus an RDMA device plugin
on the cluster. That setup is out of scope here — see the
RDMA Setup
for the transport configuration and Multinode Orchestration
for spanning workers across machines.
Use NVLink between pods on one node
To move the KV cache over NVLink between prefill and decode pods on the same node, each worker pod must share the host PID namespace and see the other worker’s GPU. One pattern that does this and keeps GPU scheduling under the device plugin:
This pattern runs workers with hostPID: true and privileged: true. The
namespace must allow Pod Security level privileged, and each worker can see
every process and device on the host. It helps only when prefill and decode
run on the same node; across nodes you still need RDMA or multi-node NVLink.
Decide with your cluster administrator whether this trade-off is acceptable.
Apply the same change to the prefill worker, and keep its own replicas and
envFromSecret.
The workers can use CUDA IPC only when they run on the same node. On a cluster
with more than one GPU node, place all prefill and decode replicas on one node,
for example with a nodeSelector on kubernetes.io/hostname in each worker’s
extraPodSpec. That node needs a free GPU for every replica: seven for this
example (three prefill, four decode).
The pieces work together:
hostPID: truelets UCX treat CUDA IPC as reachable between the two pods.privileged: truemakes the peer GPU visible, so the importing worker can open its CUDA IPC handle.- The init container requests the same GPU count as the worker. The kubelet
gives the main container the same devices, so the init container’s
nvidia-smioutput lists the GPUs allocated to this pod. - The command wrapper sets
CUDA_VISIBLE_DEVICESto those GPUs, so each worker still uses only the GPUs the scheduler assigned to it.
After you apply it, run the UCX_PROTO_INFO=y check from
Apply and verify the transfer path. The
GPU-to-GPU KV read should show cuda_ipc:
GitHub issue #16646 has the measurements behind this pattern and tracks first-class support in the operator.
Faster starting points
Typing the full spec from scratch is rarely the fastest path. Copy a validated template and adapt it:
Good recipe starting points:
Backend deployment examples with concrete worker flags:
How disaggregation relates to KV-aware routing
These are separate features that pair well. Disaggregation splits prefill and decode. KV-aware routing chooses workers based on cache locality. Many production deployments use both, but you can reason about them independently.
For router behavior, see Router: Disaggregated Serving and KV Cache Aware Routing.
Before production
- Confirm NIXL initialized on each worker (the log check above).
- Confirm the KV transfer uses the transport you expect (
cuda_ipc, RDMA, ortcp) with theUCX_PROTO_INFO=ycheck above. Separate pods on one node use TCP unless they request RDMA or use the NVLink opt-in. - Confirm prefill and decode workers agree on model, dtype, block size, and KV layout.
- Confirm pods have the required GPU and shared memory.
- Confirm frontend/router flags match your routing strategy.
- Run benchmarks inside the cluster, not through local port-forwarding.
- If you scale across nodes, validate the RDMA transfer path — see Enable multi-node transfer.
Use Dynamo Benchmarking to compare aggregated and disaggregated configurations under the same workload.
Next steps
- Start from a matching Dynamo Recipe when one exists.
- Read the backend-specific
disagg.yamlfor your engine. - Use Sizing with AIConfigurator or DGDR to choose prefill/decode sizing.
- Validate with Dynamo Benchmarking.