Admission Control
Backend admission control limits requests inside each engine and queues excess work outside it. Configure the gate on the worker containers in your DynamoGraphDeployment (DGD). It supports both Dynamo Python and Dynamo Sidecar backends.
For behavior and tuning guidance, see Admission Control Architecture.
Configure the Worker
Start with a working DynamoGraphDeployment. These three settings apply per data-parallel (DP) rank:
Setting either engine limit enables admission control; an engine limit left unset stays unlimited. When either engine limit is reached, new requests wait in the gate queue. If the queue is full, the worker rejects them; overload reaches the client as HTTP 529 by default.
The following nvidia.com/v1beta1 fragment enables admission control with the recommended starting
limits for an engine whose max_num_seqs is 256: each engine limit at max_num_seqs, and a queue of
twice that. Add these entries to your worker container’s existing env list.
For a disaggregated deployment, configure prefill and decode workers separately. Set these variables on the workers, not the frontend. See Configuration for CLI precedence and aliases, and Best Practices for tuning from the starting limits.
Verify the Configuration
Check the worker logs for the effective limits. Under load, use the dynamo_backend_admission_*
metrics to observe engine occupancy, queued requests, rejections, and cancellations. These metrics
stay at zero while admission control is disabled. The dp_rank label identifies the rank;
unspecified covers unranked requests. Sum over dp_rank for worker totals.
See Metrics for metric names and labels.