Networking Planning and Design#

Network architecture planning for GB200 and GB300 systems following the SuperPOD reference design framework. The majority of networking requirements are comprehensively addressed in the Ethernet reference documentation. The SuperPOD reference design for GB200/GB300 adopts an EVPN Multihoming VXLAN architecture with Head-End Replication for North-South networking, leveraging symmetric routing for optimal traffic flow. Additional supporting information is provided in this document.

GB200/GB300 EVPN w/ Head-End Replication

Figure 3 GB200/GB300 EVPN w/ Head-End Replication#

EVPN Symmetric routing with Cumulus Linux: Each VTEP automatically uses a unique MAC address by default.

Pros

Cons

Simple — each VTEP uses its own MAC. No coordination required for a shared address. Easier to troubleshoot per-node traffic.

When a host MAC moves (e.g. failover), remote VTEPs must update their MAC tables for the new VTEP’s MAC.

North-South Ethernet Networking#

Data and OOB prefix layout#

Networks are allocated from a data prefix (in-band and related subnets) and an OOB prefix (out-of-band management). Example root ranges appear in the table titles; use your site’s actual prefixes. Sizes, VLAN IDs, and names are reference examples—align all values with your design and BCM configuration.

Table 3 From the data prefix (example 192.168.0.0/21)#

Network

Size

VLAN

Purpose

internalnet

/24

100

InBand (data) control plane

dgxnet[1-n]

/25

10[1-n]

Group of 4 GB200 racks

dgxnet[1-n]

/24

10[1-n]

Group of 8 GB300 racks

inband_loopbacks

/27

—

Loopbacks for inband VRFs

Table 4 From the OOB prefix (example 192.168.8.0/21)#

Network

Size

VLAN

Purpose

ipminet0

/23

201

Primary OOB, switch eth0

ipminet1

/22

202

DGX BMC, IB switch COMe

oob_loopbacks

/27 or /26

—

OOB VRF loopback pool

ipminet2

/25

203

Secondary control plane OOB

Subnetting Breakout#

For subnetting breakout based on DGX system type and scale unit, refer to the Network Breakdown IP Plan Subnetting Calculator.

Ethernet Planning#

This section provides a comprehensive guide for planning and designing the Ethernet networking for the GB200/GB300 SuperPOD.

Verify the hardware components for accuracy in model and quantity#

  • Ethernet switches (SN5600)

  • Transceivers (optical)

  • Cables (DAC / AOC)

Confirm Required Cumulus Linux Software Version#

The SBOM for your Mission Control release lists the required Cumulus Linux version.

Obtain Customer Network Requirements#

Content/Consideration List#

  • Customer-Edge to Cluster connectivity

  • Transceiver type, compatibility and HW order status

  • Electrical signaling/encoding (NRZ vs PAM4)

  • Speed/Bandwidth

  • Uplink Quantity (transceiver, cable, fiber)

  • IP Addressing - P2P Uplinks

  • Routing protocol (default: BGP)

EVPN Planning Stage#

VRF / VLAN / VNI Mapping#

Per scalable unit, InBand and OOB VLANs require L3VNIs. VRF-level identifiers are summarized in the following table.

Table 5 VRF definitions#

VRF Type

L3VNI

L3VNI VLAN

Purpose

Route leaked within VRF

OOB

10010

1001

OOB control plane

Import EXIT (optional)

INBAND

200100

2001

InBand data control plane and DGX

Import EXIT (required)

STORAGE

400100

RoCEv2 high-speed storage

EXIT

Edge routing to external switches

  • Export INBAND (required)

  • and OOB (optional)

Cluster Route Advertisement and External Reachability#

Cluster Route Advertisement and External Reachability is checked for the following components:

  • BMS Connectivity - Data Center Environment Monitoring

  • 3rd Party Appliance Connectivity Requirements (Storage, etc.)

  • Physical Connectivity (Type, Speed, etc.)

  • Logical Connectivity (L2, Bond, L3, etc.)

  • IP Addressing

Preparation Information Requirements#

The following information is required for the preparation:

  • Obtain the factory rack inventory file. Refer to Appendix Section 3 for an example.

  • Coordinate with the factory to generate copies of the serial and MAC address files for racks being shipped.

The rack inventory is essential for mapping MAC addresses to IP allocations; otherwise, this data would need to be collected manually per NIC, which is time-consuming.

“Factory File” Available from Manufacturing Partner

Includes component level MAC/Interface/SN/PN Information:

  • GB200/GB300 compute tray

  • NVLink Switch

  • MGX Rack Power Shelf

  • SN2201

Gather MACs#

Host: BMC + N/S Provisioning Interfaces

  • Mgmt Servers (control plane)

  • UFM Servers

  • NetQ servers

Switch: Mgmt interface (mgmt. or eth0)

  • Ethernet

PDUs: Mgmt interface (mgmt. or eth0)

Point-to-Point Cabling Connectivity Plan (Required)