Field of view (FOV) API Guide

FOV Counts, Alerts and Alert Rule are accessible via the Web API.

FOV API Endpoints

Analytics Web API is exposed via Ingress Controller.

The URL prefix is http://<INGRESS-HOST-IP>:<INGRESS-PORT>/emdx/.

Replace the INGRESS-HOST-IP with the Jetson device IP. Replace the INGRESS-PORT with 30080 or the last value defined in Ingress configuration.

Retrieve FOV counts

Lists count of people in camera field of view.

HTTP GET

/api/metrics/occupancy/fov/histogram?sensorId=ENDEAVOR&fromTimestamp=2020-10-30T20:00:00.000Z&toTimestamp=2020-10-31T01:00:00.000Z

Mandatory query parameters

sensorId

description: Sensors for which FOV metrics need to be returned.

type: string.

example: sensorId=Amcrest_1

fromTimestamp

description: lower bound of the timestamp for which fov count needs to be returned.

type: UTC / GMT timestamp string

example: 2020-10-30T20:00:00.000Z

toTimestamp

description: Upper bound of timestamp for which fov count & alert needs to be returned. If Not specified defaults to UTC.NOW on the server.

type: UTC / GMT timestamp string

example: 2020-10-30T20:05:00.000Z

Optional query parameters

alerts

description: Enable alerts data in the results.

type: boolean

If parameter is true, return alerts for the requested duration in the response. If parameter is absent or false, alerts are not returned as part of the response.

fixedInterval

description : Requested time range (fromTimestamp - toTimestamp) fragmented into histogram of interval fixedInterval milliseconds. Minimum value of 1000 milli sec (1sec). Multiple of 1000 milli sec (1 sec) values only supported.

type: int

Limitation: If the number of histogram in the result exceeds 1000, the API will result in error with status 422.

If this parameter is not specified the service will decide the time interval of histogram based on the configuration values metrics.fov.barCount.[min, max]. The number of histogram returned will be an average of the min and max value. Accordingly the interval will be decided as follows

interval = (toTimestamp-fromTimestamp) / ((metrics.fov.barCount.min+metrics.fov.barCount.max)/2)

Response

HTTP GET

{
    "alerts": [],
    "counts": [
      {
        "agg_window": "2 sec",
        "histogram": [
          {
            "end": "2020-01-26T19:16:30.000Z",
            "start": "2020-01-26T19:16:29.000Z",
            "avg_count": 1,
            "min_count": 0,
            "max_count": 2
          },
          .
          .
          .

          {
            "end": "2020-01-26T19:17:29.000Z",
            "start": "2020-01-26T19:17:28.000Z",
            "avg_count": 1.5,
            "min_count": 1,
            "max_count": 3
          }
        ],
        "attributes": [],
        "sensorId": "ENDEAVOR",
        "type": "fov_count"
      }
    ]
  }

Error Response

Response body: See Error response body definition at the end of the page.

HTTP Status codes:

422: No FOV metrics found for the requested sensor and time range 500: Internal server error

Example

Query FOV counts for 5 minutes time range and aggregate the results into 10sec non-overlapping fixed interval.

/api/metrics/occupancy/fov/histogram?sensorId=ENDEAVOR&fromTimestamp=2020-10-30T20:00:00.000Z&toTimestamp=2020-10-30T20:05:00.000Z&fixedInterval=10

Retrieve FOV Alerts

FOV Alerts can be retrieved using the API which has filtering for sensor, time ranges with optional support for pagination

All FOV Alerts for a specific sensor for time range

HTTP GET

/api/alerts/fov?sensorId=Amcrest_1&fromTimestamp=2021-09-16T06:06:00.000Z&toTimestamp=2021-09-16T06:07:00.000Z

Mandatory query parameters

sensorId

description: Sensors for which FOV metrics need to be returned.

type: string.

example: sensorId=Amcrest_1

fromTimestamp

description: lower bound of the timestamp for which fov alerts needs to be returned

type: UTC / GMT timestamp string

example: 2020-10-30T20:00:00.000Z

toTimestamp

description: Upper bound of timestamp for which fov alert needs to be returned. If Not specified defaults to UTC.NOW on the server

type: UTC / GMT timestamp string

example: 2020-10-30T20:05:00.000Z

limit

description: max number of alerts to be returned

type: integer

example: 100

It follows Time based simple pagination. Get latest 10 (limit) alerts which occurred between 2021-09-16T06:06:00.000Z (fromTimestamp) and 2021-09-16T06:07:00.000Z (endTimestamp). Criteria is that endTimestamp > fromTimestamp

Example

Get all alerts between 2021-09-16T06:06:00.000Z (fromTimestamp) and 2021-09-16T06:07:00.000Z (toTimestamp).

Response:

/api/alerts/fov?sensorId=Amcrest_1&fromTimestamp=2021-09-16T06:06:00.000Z&toTimestamp=2021-09-16T06:07:00.000Z

{
   "alerts": [
         {
               "count": 10,
               "description": "10 people entered fov",
               "duration": 0.734,
               "endTimestamp": "2021-09-16T06:07:00.534Z",
               "id": "unique-alert-id",
               "rule_type": "increment",
               "sensorId": "Amcrest_3",
               "startTimestamp": "2021-09-16T06:06:59.800Z",
               "type": "fov",
               "direction": "entry"
         },
         {
               "count": 10,
               "description": "more than 5 ppl continuously present in FOV for longer than 10 seconds",
               "duration": 10.734,
               "endTimestamp": "2021-09-16T06:07:00.534Z",
               "id": "unique-alert-id",
               "rule_type": "occupancy",
               "sensorId": "Amcrest_3",
               "startTimestamp": "2021-09-16T06:06:59.800Z",
               "type": "fov"
         },
         {
               "count": 5,
               "description": "FOV occupancy count greater than 5",
               "duration": 10.734,
               "endTimestamp": "2021-09-16T06:07:00.534Z",
               "id": "unique-alert-id",
               "rule_type": "occupancy_threshold_switch",
               "sensorId": "Amcrest_3",
               "startTimestamp": "2021-09-16T06:06:59.800Z",
               "type": "fov",
               "direction": "up"
         }
      ]
}

Error Response

Response body: See Error response body definition at the end of the page.

HTTP Status codes:

422: No FOV alerts found for the requested sensor and time range 500: Internal server error

Get all latest 10 (limit) alerts between 2021-09-16T06:06:00.000Z (fromTimestamp) and 2021-09-16T06:07:00.000Z (toTimestamp).

/api/alerts/fov?sensorId=Amcrest_1&fromTimestamp=2021-09-16T06:06:00.000Z&toTimestamp=2021-09-16T06:07:00.000Z&limit=10

Configure FOV alert rules

Three types of alerts rules i.e., Increment, Occupancy, Occupancy Threshold Switch are supported.

Occupancy Alert Type

Alert when count_threshold of people present in the ROI continuously for longer than time_interval seconds

Example: Alert rule to raise an alert when 100 or more people are continuously present in the FOV for more than 10 seconds.

HTTP POST

/api/config/rule/alerts/fov

{
   "sensorId": "Amcrest_1",
   "rules": [
      {
         "rule_id": "d8f0484f-b464-4a92-a5a9-649a14160b53",
         "id": "Amcrest_1",
         "type": "fov",
         "rule_type": "occupancy",
         "name": "Overcrowding scenario rule",
         "time_interval": 10,
         "count_threshold": 100
      }
   ]
}

Mandatory body parameters

sensorId

description: Sensors for which alert rule is to be created.

type: string

example: Amcrest_1

rules

description: array of alert rules.

type: array

example:

{
   "rule_id": "cd2218f6-e4d2-4ad4-9b15-3396e4336064",
   "id": "Amcrest_1",
   "name": "Over crowding scenario rule",
   "type": "fov",
   "rule_type": "occupancy",
   "time_interval": 10,
   "count_threshold": 100
}

Each alert rule consists of following parameters:

Mandatory rule parameters

rule_id

description: Unique ID for this alert rule. This should be unique across all alert rules

type: string

example: UUID e.g cd2218f6-e4d2-4ad4-9b15-3396e4336064

id

description: Refers to the FOV for which alert rule applies. Since FOV are not required to be explicitly configured. This can contain the name of the sensor itself for FOV alert rule.

type: string

example: Amcrest_1

type

description: Type of analytics module this alert relates to. Fixed value ‘fov’

type: string

example: fov

rule_type

description: Type of alert rule. Fixed value ‘occupancy’

type: string

value: occupancy

time_interval

description: Time window. Specified in seconds.

type: float

example: 10

count_threshold

description: Threshold on Number of counts.

type: int

example: 100

Optional rule parameters

name

description: User friendly name for the alert rule. For display purpose on the client side

type: string

example: “Over crowding scenario rule”

Note

You will need to set User-Type=Admin in the HTTP header of the HTTP POST request.

Error Response

Response body: See Error response body definition at the end of the page.

HTTP Status codes:

403: Authorization error. User-Type header missing. Must be present with Admin as value 500: Internal server error

Occupancy Threshold Switch Alert Type

Alerts based on change of occupancy above or below count_threshold of detected objects present in the field. Most simple use case is when FOV status changes from vacant (occupancy == 0) to occupied (occupancy >= 1). The inverse of this is when occupancy changes from occupied (occupancy >= 1) to vacant ( occupancy == 0).

HTTP POST

/api/config/rule/alerts/fov

{
   "sensorId": "Amcrest_1",
   "rules": [
      {
         "rule_id": "ae511b25-a57d-483f-b4c5-c30e039cc375",
         "id": "Amcrest_1",
         "type": "fov",
         "rule_type": "occupancy_threshold_switch",
         "time_interval": 1,
         "count_threshold": 1,
         "parameters": [
            {
               "name":"time_interval_up",
               "value":1,
            },
            {
               "name":"time_interval_down",
               "value":2,
            }
         ]
      }
   ]
}

Mandatory body parameters

sensorId

description: Sensor for which FOV alert rule is to be created.

type: string

example: Amcrest_1

rules

description: array of alert rules.

type: array.

example:

{
   "rule_id": "ae511b25-a57d-483f-b4c5-c30e039cc375",
   "id": "Amcrest_1",
   "type": "fov",
   "rule_type": "occupancy_threshold_switch",
   "time_interval": 1,
   "count_threshold": 1,
   "parameters": [
      {
         "name":"time_interval_up",
         "value":1,
      },
      {
         "name":"time_interval_down",
         "value":2,
      }
   ]
}

Each alert rule consists of following parameters:

Mandatory rule parameters

rule_id

description: Unique ID for this alert rule. This should be unique across all alert rules

type: string

example: UUID e.g ae511b25-a57d-483f-b4c5-c30e039cc375

id

description: Refers to the FOV for which alert rule applies. Since FOV are not required to be explicitly configured. This can contain the name of the sensor itself for FOV alert rule.

type: string

example: Amcrest_1

type

description: Type of analytics module. Fixed value ‘fov’

type: string

value: fov

rule_type

description: Type of alert rule. Fixed value ‘occupancy_threshold_switch’

type: string

value: occupancy_threshold_switch

time_interval

description: Time window. Specified in seconds. Indicate the duration for which the counts needs to above or below the threshold for the alert to be raised. It is used to deal jitters in occupancy counts and smoothen the publication of alerts in case of such jitters.

type: float

example: 1

count_threshold

description:

Number of counts threshold used to determine status

  1. count_threshold of zero indicates alert to be raised when occupancy changes from zero to greater than zero. Inverse of this is when occupancy falls to zero from a positive number greater than zero then an alert is raised.

  2. positive non-zero count_threshold (N) means we want to raise alert when occupancy exceeds N raise the UP alert (direction=up) while when the occupancy falls to N or below raise the DOWN (direction=down) alert.

type: int

example: 1

Optional rule parameters

parameters

description: Rule specific parameters, specified as an array of name, value pairs.

type: array of name, value pairs

example: Following is the valid parameters supported by occupancy_threshold_switch alert type

parameters: [
  {
     "name":"time_interval_up",
     "value":1,
  },
  {
     "name":"time_interval_down",
     "value":2,
  }
]

time_interval_up: The time interval for vacant to occupied state change

time_interval_down: The time interval for occupied to vacant state change

name

description: User friendly name for the alert rule. For display purpose on the client side

type: string

example: “Over crowding scenario rule”

Note

You will need to set User-Type=Admin in the HTTP header of the HTTP POST request.

Error Response

Response body: See Error response body definition at the end of the page.

HTTP Status codes:

403: Authorization error. User-Type header missing. Must be present with Admin as value 500: Internal server error

Increment Alert Type

Alerts based on count_threshold of object entered/exited in the field of view within time_interval seconds.

Create a new alert rule

HTTP POST

/api/config/rule/alerts/fov

{
   "sensorId": "Amcrest_1",
   "rules": [
      {
         "rule_id": "fb298ea4-30aa-4085-b860-42e37c5bf8d1",
         "id": "Amcrest_1",
         "type": "fov",
         "rule_type": "increment",
         "time_interval": 1,
         "count_threshold": 1,
         "direction": "entry"
      },
      {
         "rule_id": "9c5632af-ba68-46bc-a997-858bdadc6856",
         "id": "Amcrest_1",
         "type": "fov",
         "rule_type": "increment",
         "time_interval": 5,
         "count_threshold": 10,
         "direction": "exit"
      }
   ]
}

Mandatory body parameters

sensorId

description: Sensors for which alert rule is to be created.

type: string.

example: Amcrest_1

rules

description: array of alert rules.

type: array.

example:

{
   "rules": [
      {
         "rule_id": "fb298ea4-30aa-4085-b860-42e37c5bf8d1",
         "id": "Amcrest_1",
         "type": "fov",
         "rule_type": "increment",
         "time_interval": 1,
         "count_threshold": 1,
         "direction": "entry"
      },
      {
         "rule_id": "9c5632af-ba68-46bc-a997-858bdadc6856",
         "id": "Amcrest_1",
         "type": "fov",
         "rule_type": "increment",
         "time_interval": 5,
         "count_threshold": 10,
         "direction": "exit"
      }
   ]
}

Each alert rule consists of following parameters:

Mandatory rule parameters

rule_id

description: Unique ID for this alert rule. This should be unique across all alert rules

type: string

example: UUID e.g fb298ea4-30aa-4085-b860-42e37c5bf8d1

id

description: Refers to the FOV for which alert rule applies. Since FOV are not required to be explicitly configured. This can contain the name of the sensor itself for FOV alert rule.

type: string

example: Amcrest_1

type

description: Type of analytics module. Fixed value ‘fov’

type: string

value: fov

rule_type

description: Type of alert rule. Fixed value ‘increment’

type: string

value: increment

time_interval

description: Time window. Specified in seconds.

type: float

example: 5

count_threshold

description: Threshold on number of people to consider for alert rule.

type: int

example: 10

direction

description: Directionality for the alert rule. Does it rule refer to number of objects leaving FOV (exit) or entering FOV (entry)

type: string

enum: One of entry/exit

example: exit

Optional rule parameters

name

description: User friendly name for the alert rule. For display purpose on the client side

type: string

example: “Over crowding scenario rule”

Note

You will need to set User-Type=Admin in the HTTP header of the HTTP POST request.

Error Response

Response body: See Error response body definition at the end of the page.

HTTP Status codes:

403: Authorization error. User-Type header missing. Must be present with Admin as value 500: Internal server error

Delete FOV alert rule

HTTP DELETE

/api/config/rule/alerts/fov?sensorId=Amcrest_1&ruleId=fb298ea4-30aa-4085-b860-42e37c5bf8d1

Mandatory query parameters

sensorId

description: Sensor for which FOV alert is to be deleted.

type: string

example: Amcrest_1

ruleId

description: Unique rule_id of the Alert rule which is to be deleted

type: string

example: fb298ea4-30aa-4085-b860-42e37c5bf8d1

Note: (Will need User-Type: Admin to be set in the HTTP header of the HTTP DEL request.)

Error Response

Response body: See Error response body definition at the end of the page.

HTTP Status codes:

403: Authorization error. User-Type header missing. Must be present with Admin as value 422: No alert rule present for the specified sensor and rule Id 500: Internal server error

Retrieve FOV alert rule

HTTP GET

/api/config/rule/alerts/fov?sensorId=Amcrest_1

sensorId

description: Sensor for which fov alert rule needs to be returned.

type: string

example: sensorId=Amcrest_1

Error Response

Response body: See Error response body definition at the end of the page.

HTTP Status codes:

422: No alert rules present for the specified sensor 500: Internal server error

All Historical FOV Alert Rules

/api/config/rule/alerts/fov/history?sensorId=Amcrest_1

sensorId

description: Sensor for which historical fov alert rule needs to be returned.

type: string

example: sensorId=Amcrest_1

Error Response

Response body: See Error response body definition at the end of the page

HTTP Status codes:

422: No alert rules present for the specified sensor 500: Internal server error

Error Response body:

Error response for all API is JSON object with following attributes.

{
   "detail": "#Detailed error string",
   "status": "#http-status-code",
   "title": "Unprocessable Entity",
   "type": "about:blank"
}