What can I help you with?
NVIDIA Spectrum-3 SN4000 1U and 2U Switch Systems Hardware User Manual

Thermal Threshold Definitions

Three thermal threshold definitions are measured by the Spectrum®-3 ASICs, and impact the overall switch system operation state as follows:

  • Warning 105°C: On managed systems only: When the ASIC device crosses the 100°C threshold, a warning threshold message will be issued by the management software, indicating to system administration that the ASIC has crossed the warning threshold. Note that this temperature threshold does not require nor lead to any action by the hardware (such as switch shutdown).

  • Critical 120°C: When the ASIC device crosses this temperature, the switch firmware will automatically shut down the device.

  • Emergency 130°C: In case the firmware fails to shut down the ASIC device upon crossing its critical threshold, the device will auto-shutdown upon crossing the emergency (130°C) threshold.

For thermal threshold definitions in Cumulus Linux, see Configuring Configuring SNMP Traps Traps in the Cumulus User Guide.

© Copyright 2025, NVIDIA. Last updated on Apr 28, 2025.