Bug Fixes in this Firmware Version

For a list of old Bug Fixes, please see Bug Fixes History.

Internal Ref.

Issue

3134894

Description: Fixed an issue where set_flow_table_entry failed when aso_flow_meter action was used.

Keywords: ASO Flow Meter, FW Steering

Discovered in Version: 20.30.1004

Fixed in Release: 20.34.1002

3059379

Description: Added "Command Unsupported" response code in cases when running the MCTP control command "Get Vendor Defined Messages Supported", and there were no supported VDMs.

Keywords: MCTP control command

Discovered in Version: 20.30.1004

Fixed in Release: 20.34.1002

2994292

Description: Fixed a race condition occured between the duplicate read and QP commands (2RST, 2ERR and Destroy) in the signature that caused the command to hang.

Keywords: Race condition

Discovered in Version: 20.30.1004

Fixed in Release: 20.34.1002

2862173

Description: Added support for InfiniBand MAD packets capturing in RX RDMA Steering table.

Keywords: MAD, Steering

Discovered in Version: 20.33.1048

Fixed in Release: 20.34.1002

2665773

Description: Added 50 Usec delay during PML1 exit to avoid any PCIe replay timer timeout.

Keywords: PCIe. PML1

Discovered in Version: 20.33.1048

Fixed in Release: 20.34.1002

3023847

Description: Enabled sending and receiving traffic with a different LID than the host LID in MetroX applications.

Keywords: MetroX, LID based

Discovered in Version: 20.33.1048

Fixed in Release: 20.34.1002