Known Issues
Ethernet Rate Limit per VF in RoCE Mode Limitations
Dual Port Device | Single Port Device | ||||
w/o LAG (TOTAL_VFS>32) | With LAG (TOTAL_VFS<32) | w/o LAG | |||
w/o QoS | Full QoS | w/o QoS | Full QoS | w/o QoS | Full QoS |
127 | 127 | 64 | 64 | 127 | 127 |
Ethernet Rate Limit per VF in InfiniBand Mode Limitations
Dual Port Device | Single Port Device | ||
w/o LAG | w/o LAG | ||
w/o QoS | Full QoS | w/o QoS | Full QoS |
127 | 127 | 127 | 127 |
Known Issues
Internal Ref. | Issue |
3200779 | Description: Changing dynamic PCIe link width is not supported. |
Workaround: N/A | |
Keywords: PCIe | |
Discovered in Version: 20.34.1002 | |
2824427 | Description: Running with a debug firmware reduces security as if token was applied. |
Workaround: N/A | |
Keywords: Debug Firmware | |
Discovered in Version: 20.33.1048 | |
3030570 | Description: “crypto policy” access registry can be modified only by the INI file. |
Workaround: N/A | |
Keywords: AES_XTS | |
Discovered in Version: 20.33.1048 | |
2793880 | Description: Checksum is not calculated correctly in IPoIP packet with LSO. |
Workaround: N/A | |
Keywords: IPoIP, LSO, checksum | |
Discovered in Version: 20.33.1048 | |
2864238 | Description: VPD cannot be accessed after firmware upgrade or reset when the following sequence is performed:
|
Workaround: Run the upgrade or reset sequence as follow:
| |
Keywords: VDP | |
Discovered in Version: 20.32.1010 | |
2616755 | Description: Forward action for IPoIB is not supported on RX RDMA Flow Table. |
Workaround: N/A | |
Keywords: Steering, IPoIB | |
Discovered in Version: 20.32.1010 | |
2582094 | Description: When performing a stress toggle test vs. IXIA, the IXIA side is not ready for few seconds. |
Workaround: Wait for 1 sec between running the down and up commands. | |
Keywords: Auto-negotiation. | |
Discovered in Version: 20.31.1014 | |
2446583 | Description: On rare occasions, when both network devices are NVIDIA, PAM4 link will raise with several effective errors. These errors will not affect traffic once the link is up. |
Workaround: Clear counters once the link is up | |
Keywords: Effective errors | |
Discovered in Version: 20.29.2002 | |
SF 933911 | Description: PXE boot will not function if the adapter card is connected to a NVIDIA Quantum™ based switch over an HDR active optical cable. |
Workaround: Set KEEP_LINK_UP_ON_BOOT configuration to enable via mlxconfig. | |
Keywords: IB, Link Speed , Link Down, SDR , optical cable | |
Discovered in Version: 20.30.1004 | |
2378593 | Description: Sub 1sec firmware update (fast reset flow) is not supported when updating from previous releases to the current one. Doing so may cause network disconnection events. |
Workaround: Use full reset flow for firmware upgrade/downgrade. | |
Keywords: Sub 1sec firmware update | |
Discovered in Version: 20.29.1016 | |
2213356 | Description: The following are the Steering Dump limitations:
|
Workaround: N/A | |
Keywords: Steering Bump | |
Discovered in Version: 20.29.1016 | |
2365322 | Description: When configuring adapter card's Level Scheduling, a QoS tree leaf (QUEUE_GROUP) configured with default rate_limit and default bw_share, may not obey the QoS restrictions imposed by any of the leaf’s ancestors. |
Workaround: To prevent such a case, configure at least one of the following QoS attributes of a leaf: max_average_bw or bw_share | |
Keywords: QoS | |
Discovered in Version: 20.29.1016 | |
2239632 | Description: EDR linkup time might take up to 50sec when using HDR optical cable. |
Workaround: N/A | |
Keywords: Cables, EDR | |
Discovered in Version: 20.28.1002 | |
2145881 | Description: FDR link is unstable when using an FDR cable in ports: #27-#34. |
Workaround: N/A | |
Keywords: FDR, cables | |
Discovered in Version: 20.27.6008 | |
2149437 | Description: When the SLTP configuration is wrongly set, the “Bad status” explanation will not be presented (only error indication) to the user. |
Workaround: N/A | |
Keywords: SLTP configuration | |
Discovered in Version: 20.27.6008 | |
2071210 | Description: mlxconfig query for the BOOT_INTERRUPT_DIS TLV shows a wrong value in the "current value" field. |
Workaround: Use "next boot" indication to see the right value. | |
Keywords: mlxconfig | |
Discovered in Version: 20.27.1016 | |
1796936 | Description: 200GbE Optical cables in Auto-Negotiation mode work only in 200GbE speed. |
Workaround: N/A | |
Keywords: Cables | |
Discovered in Version: 20.27.1016 | |
1959529 | Description: When HDR Active Copper cables are used between Quantum switches, or between Quantum switch and ConnectX-6 HCA, the counter indicating ‘Link Down’ may have a value other than zero, after the first time the cable is connected. As this may happened only at the first time, it is recommend to clear the counters after the cluster is brought up. |
Workaround: Toggle the Active Copper or Optics cables as the switch performs a reset. | |
Keywords: Cables, BER | |
Discovered in Version: 20.27.1016 | |
1959529 | Description: Occasionally (up to 15% of connections), the link will go down when using ACC cables P/N: MCA1J00-H003E, MCA1J00-H004E and when connecting a Quantum switch to a Quantum switch. |
Workaround: N/A | |
Keywords: Cables | |
Discovered in Version: 20.27.1016 | |
1997329 | Description: Downgrading from firmware v20.26.4012 to firmware v20.26.1040 and lower is not supported on Windows OSes using the mlxfwmanager tool. |
Workaround: N/A | |
Keywords: mlxfwmanager, firmware downgrade | |
Discovered in Version: 20.26.4012 | |
1930619 | Description: PF_BAR2 and ATS cannot be enabled together, i.e. when PF_BAR2 is enabled, ATS cannot be enabled too. |
Workaround: N/A | |
Keywords: ATS, SF, BAR2, Multi GVMI | |
Discovered in Version: 20.26.1040 | |
- | Description: In rare cases, following a server powerup, a fatal error (device's health compromised) message might appear with ext_synd 0x8d1d. The error will be accompanied by a failure to use mlxconfig and in some cases flash burning tools. |
Workaround: N/A | |
Keywords: mlxconfig, flash tool, ext_synd 0x8d1d | |
Discovered in Version: 20.26.1040 | |
1796936 | Description: HDR split cables support only HDR speed. |
Workaround: N/A | |
Keywords: Link Speed, cables, Break-Out cables | |
Discovered in Version: 20.26.1040 | |
1750460 / 2063991 | Description: BER issues might occur when using ConnectX-6 adapter cards in 100GbE link speed, and connecting with and 3rd party switch systems. |
Workaround: N/A | |
Keywords: BER, 100GbE, Spectrum-2 | |
Discovered in Version: 20.26.1040 | |
1918749 | Description: mlxlink tool displays a wrong speed when using ETH cables on ConnectX-6 adapter cards. |
Workaround: N/A | |
Keywords: mlxlink | |
Discovered in Version: 20.26.1040 | |
1901198 | Description: Firmware is not loaded on Multi-Host setups after reboot. |
Workaround: N/A | |
Keywords: Firmware load, Multi-Host | |
Discovered in Version: 20.26.1040 | |
1842278 | Description: DC LAG can function only in case there is a single PF per port without any active VFs. |
Workaround: N/A | |
Keywords: DC LAG | |
Discovered in Version: 20.26.1040 | |
1796628 | Description: Due to performance considerations, unicast loopback traffic will go through the NIC SX tables, and multicast loopback traffic will skip the NIC SX tables. |
Workaround: N/A | |
Keywords: Performance, unicast loopback traffic, multicast loopback traffic | |
Discovered in Version: 20.26.1040 | |
1797493 | Description: Firmware asserts may occur when setting the PF_BAR2_SIZE value higher than the maximum supported size. |
Workaround: Configure within limits (NIC PF_BAR_SIZE <= 4). | |
Keywords: Multi-GVMI, Sub-Function, SFs, BAR2 | |
Discovered in Version: 20.26.1040 | |
- | Description: Coherent Accelerator Processor Interface (CAPI) in ConnectX-6 firmware v20.25.7020 and above has low test coverage, however, it has no known issues. |
Workaround: N/A | |
Keywords: CAPI | |
Discovered in Version: 20.25.7020 | |
- | Description: HDR optical cables and Split cables support only HDR speed. |
Workaround: N/A | |
Keywords: Link Speed, cables, Break-Out cables | |
Discovered in Version: 20.25.6000 | |
1755286 | Description: Port speed may change to SDR spontaneously, without a clear reason. |
Workaround: Keep the "keep_ib_link_up" bit at 0 in NVconfig to make sure the port is raised with the correct speed. | |
Keywords: SDR, port speed | |
Discovered in Version: 20.25.2006 | |
1774135 | Description: PXE boot is not functional when connecting a splitter cable to the host. |
Workaround: Update the SM as follow:
Default=0x7fff,ipoib,rate=5:ALL=full; Note: "rate" must be set to "5" regardless to the other flags values.
Run the following CLI commands: no ib sm ib partition Default rate 5 ib sm
Use REST API to change default partition rate: PUT https://<some IP>/ufmRest/resources/networks/management { "qos_parameters": { "rate_limit": 900 } } As a result, /opt/ufm/files/conf/opensm/partitions.conf will include the following line: management=0x7fff,ipoib, sl=0,rate=5, defmember=full : ALL, ALL_SWITCHES=full,SELF=full; | |
Keywords: PXE boot, splitter cable | |
Discovered in Version: 20.25.2006 | |
1768814/1772474 | Description: Due to hardware limitation, REG_C cannot be passed over loopback when the FDB action is forwarded to multiple destinations. |
Workaround: N/A | |
Keywords: Connection-Tracking | |
Discovered in Version: 20.25.2006 | |
1770736 | Description: When a PF or ECPF with many VFs (SR-IOV), and/or SFs (Multi-GVMI) triggers an FLR, PCIe completion timeout might occur. |
Workaround: Increase the PCIe completion timeout. | |
Keywords: Multi-GVMI, SR-IOV, Sub-Function, Virtual Function, PF FLR | |
Discovered in Version: 20.25.2006 | |
1716334 | Description: When mlxconfig.PF_BAR2_EN is enabled, configuring more than 255 PCI functions will raise an assert. |
Workaround: When working with BAR2, configure SR-IOV to align to the 255 PCI functions limitation. mlxconfig.NUM_OF_VFS controls the number of configured SR-IOV VFs. e.g.:
| |
Keywords: Multi-GVMI, PF_BAR2_EN, Sub-Functions, SR-IOV, VFs | |
Discovered in Version: 20.25.1500 [Beta] | |
1699214 | Description: NODNIC VF is partially tested. It is fully tested only in ConnectX-5 adapter cards. |
Workaround: N/A | |
Keywords: NODNIC VF | |
Discovered in Version: 20.25.1500 [Beta] | |
1699214 | Description: NODNIC VF is partially tested. It is fully tested only in ConnectX-5 adapter cards. |
Workaround: N/A | |
Keywords: NODNIC VF | |
Discovered in Version: 20.25.1500 [Beta] | |
- | Description: The supported length of HDR copper cables is currently up to 2M. |
Workaround: N/A | |
Keywords: HDR cables | |
Discovered in Version: 20.25.1500 [Beta] | |
- | Description: In Ethernet mode, at 10/40GbE speeds, only NO-FEC in Force mode is supported. Other user configurations are overridden. |
Workaround: N/A | |
Keywords: Ethernet, 10GbE, 40GbE, RS-FEC | |
Discovered in Version: 20.25.1500 [Beta] | |
1574876 | Description: DC RoCE LAG is functional only if the router posts VRRP address as the source MAC. |
Workaround: N/A | |
Keywords: DC RoCE LAG | |
Discovered in Version: 20.25.1500 [Beta] | |
1498399 | Description: If the XRC switches between SRQ/RMPs while there is an outstanding ODP on the responder XRC QP, a CQE with an error might be generated (that is not a PFAULT abort). |
Workaround: N/A | |
Keywords: XRC SRQ/RMP ODP | |
Discovered in Version: 20.25.1500 [Beta] | |
- | Description: In some cases, the power consumption might be 10% higher than what is stated in the adapter cards User Manual. |
Workaround: Power consumption will be aligned with the User Manual statement in the next release | |
Keywords: Power consumption | |
Discovered in Version: 20.25.1500 [Beta] | |
1546492 | Description: Executing the update_lid command while the IB port sniffer utility is active can stop the utility. |
Workaround: N/A | |
Keywords: IB Sniffer | |
Discovered in Version: 20.25.1500 [Beta] | |
1537898 | Description: Initializing a function while the IB port sniffer utility is active can stop the utility. |
Workaround: N/A | |
Keywords: IB Sniffer | |
Discovered in Version: 20.25.1500 [Beta] | |
1414290 | Description: When getting an inline scatter CQE on IB striding RQ, the stride index in the CQE will be zero. |
Workaround: N/A | |
Keywords: Scatter CQE | |
Discovered in Version: 20.25.1500 [Beta] | |
1332714/1345824 | Description: The maximum “read” size of MTRC_STDB is limited to 272 Bytes. |
Workaround: Set the MTRC_STDB.read_size to the maximum value of 0x110=272 Bytes | |
Keywords: Access register, MTRC_STDB, tracer to dmesg, fwtrace to dmesg | |
Discovered in Version: 20.25.1500 [Beta] | |
1408994 | Description: FTE with both forward (FWD) and encapsulation (ENCAP) actions is not supported in the SX NIC Flow Table. |
Workaround: N/A | |
Keywords: SX NIC Flow Table | |
Discovered in Version: 20.25.1500 [Beta] | |
1027553 | Description: While using e-switch vport sVLAN stripping, the RX steering values on the sVLAN might not be accurate. |
Workaround: N/A | |
Keywords: e-sw vport sVLAN stripping, RX steering | |
Discovered in Version: 20.25.1500 [Beta] | |
1799917 | Description: Untagged CVLAN packets in the Steering Flow Tables do not match the SVLAN tagged packets. |
Workaround: N/A | |
Keywords: Steering Flow Tables, CVLAN/SVLAN packets | |
Discovered in Version: .20.25.1500 [Beta] | |
1277762 | Description: An Ethernet multicast loopback packet is not counted (even if it is not a local loopback packet) when running the nic_receive_steering_discard command. |
Workaround: N/A | |
Keywords: Ethernet multicast loopback packet | |
Discovered in Version: 20.25.1500 [Beta] | |
1306342 | Description: Signature-accessing WQEs sent locally to the NVMeF target QPs that encounter signature errors, will not send a SIGERR CQE. |
Workaround: N/A | |
Keywords: Signature-accessing WQEs, NVMeF target | |
Discovered in Version: 20.25.1500 [Beta] | |
1168594 | Description: RoCE Dual Port Mode (a.k.a Multi-Port vHCA: MPV) is not supported in Multi-Host setups. |
Workaround: N/A | |
Keywords: Multi-Port vHCA, Multi-Host | |
Discovered in Version: 20.25.1500 [Beta] | |
1072337 | Description: If a packet is modified in e-sw flow steering, the SX sniffer Flow Table (of the VF) will see the sniffed packet after the modification. |
Workaround: N/A | |
Keywords: SX sniffer Flow Table | |
Discovered in Version: 20.25.1500 [Beta] | |
1171013 | Description: Signature Handover Operations is not supported when FPP (Function-Per-Port) mode is disabled. |
Workaround: N/A | |
Keywords: Signature Handover Operations, FPP | |
Discovered in Version: 20.25.1500 [Beta] | |
1059975 | Description: NVMeF limitation:
|
Workaround: N/A | |
Keywords: NVMeF | |
Discovered in Version: 20.25.1500 [Beta] |