Bug Fixes History
This section includes history of bug fixes of 3 major releases back. For older releases history, please refer to the relevant firmware versions Release Notes in https://docs.mellanox.com/category/adapterfw.
Internal Ref. |
Issue |
3365411 |
Description: Fixed a link failure that occurred due to a wrong 'is_inphi_cable' indication. |
Keywords: Link failure |
|
Discovered in Version: 26.37.1014 |
|
Fixed in Release: 26.38.1002 |
|
3331179 |
Description: Improved token calculation. |
Keywords: Token calculation |
|
Discovered in Version: 26.37.1014 |
|
Fixed in Release: 26.38.1002 |
|
3491841 |
Description: Fixed a firmware assert that occurred when tried to verify if the module supported "swap". |
Keywords: Firmware assert |
|
Discovered in Version: 26.37.1014 |
|
Fixed in Release: 26.38.1002 |
Internal Ref. |
Issue |
3434928 |
Description: Modified the RDE behavior to return an error if the chassis ID subtype is AgentId, or Port ID subtype is ChassisComp. |
Keywords: RDE |
|
Discovered in Version: 26.36.1010 |
|
Fixed in Release: 26.37.1014 |
|
3438177 |
Description: Enabled VF LAG hash mode. The LAG_RESOURCE_ALLOCATION mlxconfig field is now modifiable. |
Keywords: VF LAG |
|
Discovered in Version: 26.36.1010 |
|
Fixed in Release: 26.37.1014 |
|
2797986 |
Description: Fixed an issue that prevented the adapter card from handling WoL packets when the host powered up directly into the standby mode. |
Keywords: WoL packets |
|
Discovered in Version: 26.36.1010 |
|
Fixed in Release: 26.37.1014 |
|
3327847 |
Description: CNP received, handled, and ignored counters in the hardware counters cannot work after moving to Programmable Congestion Control mode. |
Keywords: CNP, Programmable Congestion Control |
|
Discovered in Version: 26.36.1010 |
|
Fixed in Release: 26.37.1014 |
Internal Ref. |
Issue |
3239340 |
Description: Aligned RDE behavior to DSP0266 v1.15.0 table 23. |
Keywords: RDE |
|
Discovered in Version: 26.35.1012 |
|
Fixed in Release: 26.36.1010 |