Internal Ref. | Issue |
3110205 | Description: Fixed inconsistent TCP performance when sending multiple streams. |
Keywords: Performance | |
Discovered in Version: 28.34.1002 | |
Fixed in Release: 28.34.4000 | |
3138401 | Description: Fixed an issue that caused host's PCI device to disappear after running 12V cycles in a loop while there was traffic between the hosts in a Multi-Host platform. |
Keywords: PCI device, Multi-Host platform, 12V cycles | |
Discovered in Version: 28.34.1002 | |
Fixed in Release: 28.34.4000 | |
3148833 | Description: Fixed an issue that resulted in lack of communication with the BMC from the host (IPv4/IPv6) when using BMC version v2022.22.1. |
Keywords: BMC | |
Discovered in Version: 28.34.1002 | |
Fixed in Release: 28.34.4000 | |
3143956 | Description: When connecting a ConnectX-7 adapter card to ConnectX-7 adapter card, once in few fwresets the link may raise in 1G speed instead of the highest speed enabled. |
Keywords: Speed rate | |
Discovered in Version: 28.34.1002 | |
Fixed in Release: 28.34.4000 |
Internal Ref. | Issue |
2931516 | Description: Added support for SPDM Get_measurements command. Note: Executing the command with a signature request without measurements, can cause an invalid L1 hash calculation. |
Keywords: SPDM | |
Discovered in Version: 28.33.4030 | |
Fixed in Release: 28.34.1002 | |
3091233 | Description: Added support for SPDM Challenge command. |
Keywords: SPDM | |
Discovered in Version: 28.33.4030 | |
Fixed in Release: 28.34.1002 | |
2907008 | Description: Fixed PCIe link down failures during PCIe speed change tests. |
Keywords: PCIe, link down | |
Discovered in Version: 28.33.4030 | |
Fixed in Release: 28.34.1002 | |
3134894 | Description: Fixed an issue where set_flow_table_entry failed when aso_flow_meter action was used. |
Keywords: ASO Flow Meter, FW Steering | |
Discovered in Version: 28.33.2028 | |
Fixed in Release: 28.34.1002 | |
3039007 | Description: Enabled Multi-Host RX Rate-limiter configuration via the QEEC mlxreg and the max_shaper_rate field. |
Keywords: RX Rate-Limiter, Multi-host | |
Discovered in Version: 28.33.4030 | |
Fixed in Release: 28.34.1002 | |
3059379 | Description: Added "Command Unsupported" response code in cases when running the MCTP control command "Get Vendor Defined Messages Supported", and there were no supported VDMs. |
Keywords: MCTP control command | |
Discovered in Version: 28.33.4030 | |
Fixed in Release: 28.34.1002 | |
3133476 | Description: Added the following new checks to commands' interface:
|
Keywords: Command checks | |
Discovered in Version: 28.33.4030 | |
Fixed in Release: 28.34.1002 | |
3047521 | Description: Implemented a firmware flow to power up/down the PLL from downstream links upon PERST assertion/de-assertion. |
Keywords: PLL, PERST | |
Discovered in Version: 28.33.4030 | |
Fixed in Release: 28.34.1002 | |
3132594 | Description: MAC allocation in adapter cards that support Port-Per-Host feature ("host isolation") is reordered to fit the required range. |
Keywords: MAC allocation, PortPerHost | |
Discovered in Version: 28.33.4030 | |
Fixed in Release: 28.34.1002 | |
3085879 | Description: On rare occasions, when connecting a ConnectX-7 adapter card to an NVIDIA Spectrum-3 switch system using the optical cable OPN MFA1A00-C003, the link up time is ~7sec. |
Keywords: Optical cables, link up time | |
Discovered in Version: 28.33.4030 | |
Fixed in Release: 28.34.1002 | |
2994292 | Description: Fixed a race condition occured between the duplicate read and QP commands (2RST, 2ERR and Destroy) in the signature that caused the command to hang. |
Keywords: Race condition | |
Discovered in Version: 28.33.2028 | |
Fixed in Release: 28.34.1002 | |
3023847 | Description: Enabled sending and receiving traffic with a different LID than the host LID in MetroX applications. |
Keywords: MetroX, LID based | |
Discovered in Version: 28.33.2028 | |
Fixed in Release: 28.33.4030 | |
3023847 | Description: Enabled sending and receiving traffic with a different LID than the host LID in MetroX applications. |
Keywords: MetroX, LID based | |
Discovered in Version: 28.33.2028 | |
Fixed in Release: 28.33.4030 | |
2920813 | Description: The an_disable flow is not supported in ConnectX-7 adapter cards for 25GbE and 50G_2x link speeds when using one of the following cables:
The flow is supported only when configuring FEC using the PPLM register. |
Keywords: AN, cables, 25GbE, FEC | |
Discovered in Version: 28.33.2028 | |
Fixed in Release: 28.33.4030 | |
3039348 | Description: Host Chaining is currently not supported in ConnectX-7 adapter cards. |
Keywords: Host Chaining | |
Discovered in Version: 28.33.2028 | |
Fixed in Release: 28.33.4030 | |
3023751 | Description: Link flapping may occur when using ConnectX-7 adapter cards with HDR optic cables. |
Keywords: Link flapping, HDR optic cables | |
Discovered in Version: 28.33.2028 | |
Fixed in Release: 28.33.4030 | |
3046168 | Description: Congestion Control is not enabled when one link type of different ports is different. |
Keywords: Congestion Control, Link Type, PCC | |
Discovered in Version: 28.33.2028 | |
Fixed in Release: 28.33.4030 | |
3009525 | Description: A Bit Error Rate (BER) of 1e-9 might occur when using optical cables. |
Keywords: BER | |
Discovered in Version: 28.33.4030 | |
Fixed in Release: 28.34.1002 | |
3036791 | Description: Configuring 400G_8x in force mode is currently not supported. |
Keywords: 400G_8x in force mode | |
Discovered in Version: 28.33.4030 | |
Fixed in Release: 28.34.1002 | |
3004352 | Description: LRO is currently not supported. |
Keywords: LRO | |
Discovered in Version: 28.33.4030 | |
Fixed in Release: 28.34.1002 |
Internal Ref. | Issue |
2969829 | Description: On rare occasions, the HDR speed link up time when using the optical module MFA7U10-H010 might take up to 70sec. |
Keywords: HDR, link up time, optical cable | |
Discovered in Version: 28.33.2028 | |
Fixed in Release: 28.33.4030 | |
3024199 | Description: When connecting a ConnectX-7 adapter card to an NVIDIA Quantum switch using the copper cable (MCP1600-E01AE30), the link is Down when in EDR speed. |
Keywords: EDR, copper cable, NVIDIA Quantum | |
Discovered in Version: 28.33.2028 | |
Fixed in Release: 28.33.4030 | |
2947588 | Description: Trying to query/burn the firmware using the flint utility when the image is pending (after firmware burn and before firmware reset), results in the action's failure. |
Keywords: flint, query/burn firmware | |
Discovered in Version: 28.33.2028 | |
Fixed in Release: 28.33.4030 | |
3047723 | Description: When changing the protocols from ETH to IB on two ConnectX-7 adapter cards connected to each other, the ports on both sides must be toggled to get the link up. |
Keywords: Linkup, port toggling, protocol change | |
Discovered in Version: 28.33.2028 | |
Fixed in Release: 28.33.4030 | |
3033874 | Description: Connecting a ConnectX-7 adapter card to either a ConnectX-5 adapter card or to an NVIDIA Spectrum switch system is supported only when using a 100GbE optic cables and when configuring ConnectX-5 or the NVIDIA Spectrum switch system to Force Mode. |
Keywords: Linkup connectivity | |
Discovered in Version: 28.33.2028 | |
Fixed in Release: 28.33.4030 |