Known Issues
VF Network Function Limitations in SRIOV Legacy Mode
Dual Port Device  | Single Port Device  | 
127 VF per PF (254 functions)  | 127  | 
VF Network Function Limitations in Switchdev Mode
Dual Port Device  | Single Port Device  | 
127 VF per PF (254 functions)  | 127  | 
VF+SF Network Function Limitations in Switchdev Mode
Dual Port Device  | Single Port Device  | 
  | 
  | 
ConnectX-7 has the same feature set and limitations as ConnectX-6 adapter card. For the list of ConnectX-6 Known Issues, please go to https://docs.nvidia.com/networking/category/connectx6fw.
The below are limitations related to ConnectX-7 only.
Internal Ref.  | Issue  | 
NVbug 3971388  | Description: Reading of the MAX_ACC register value that can support debugging performance is currently not supported.  | 
Workaround: N/A  | |
Keywords: Performance  | |
Discovered in Version: 28.36.2020  | |
3342918  | Description: On rare occasions, the port might get stuck (in all speeds) during the link up flow when using optical modules.  | 
Workaround: Toggle the port to fix the issue.  | |
Keywords: Port link up, port toggling, optical modules  | |
Discovered in Version: 28.36.2020  | |
3098880  | Description: Firmware cannot reach the line rate with a single QP while running GPUDirect traffic.  | 
Workaround: N/A  | |
Keywords: Line rate, MCX750500B-0D0K / MCX750500B-0D00  | |
Discovered in Version: 28.36.2020  | |
-  | Description: Core log files and error monitoring from OOB are currently blocked by the BMC platform that supports ConnectX-7 host management protocols.  | 
Workaround: N/A  | |
Keywords: BMC, MCX750500B-0D0K / MCX750500B-0D00  | |
Discovered in Version: 28.36.2020  | |
3257759  | Description: Firmware reset is disabled by default.  | 
Workaround: N/A  | |
Keywords: Firmware reset, MCX750500B-0D0K / MCX750500B-0D00  | |
Discovered in Version: 28.36.2020  | |
3263559  | Description: Firmware does not load after warm reboot.  | 
Workaround: Perform a full power cycle to load the firmware.  | |
Keywords: Warm reboot, power cycle, MCX750500B-0D0K / MCX750500B-0D00  | |
Discovered in Version: 28.36.2020  | |
3262845  | Description: In the ConnectX-7 adapter card with P/N MCX750500B-0D0K, the "Fatal Error Reporting Enable" bit controls both the fatal and the non-fatal ERR MSG forwarding. The "Non-Fatal Error Reporting Enable" bit does not affect the ERR MSG forwarding.  | 
Workaround: N/A  | |
Keywords: Fatal Error Reporting Enable" bit, PCIe, MCX750500B-0D0K  | |
Discovered in Version: 28.36.1010  | |
3327847  | Description: CNP received, handled, and ignored counters in the hardware counters cannot work after moving to Programmable Congestion Control mode.  | 
Workaround: N/A  | |
Keywords: CNP, Programmable Congestion Control  | |
Discovered in Version: 28.36.1010  | |
3312483  | Description: WoL packets may not working properly if sent to Unicast destination MAC.  | 
Workaround: N/A  | |
Keywords: WoL packets, Unicast destination MAC  | |
Discovered in Version: 28.36.1010  | |
3339919  | Description: 
  | 
Workaround: To raise in Force flow, configure the speed, FEC and precoding.  | |
Keywords: Link up speed  | |
Discovered in Version: 28.36.1010  | |
3339818  | Description: When performing a stress toggling on a ConnectX-7 adapter card that is connected to the MMA1Z00-NS400 cable and the speed is set to 100G_1x with interleaved FEC, a long linkup time of up to 5 min may occur.  | 
Workaround: N/A  | |
Keywords: Toggling, MMA1Z00-NS400  | |
Discovered in Version: 28.36.1010  | |
3329109  | Description: MFS1S50-H003E cable supports only HDR rate when used as a split cable.  | 
Workaround: N/A  | |
Keywords: HDR, split cable, MFS1S50-H003E  | |
Discovered in Version: 28.36.1010  | |
2844036  | Description: When using the "Dual Write" feature with QP buffer bigger than the maximum outstanding WQEs (128), the data being sent on the standby QP can be corrupted.  | 
Workaround: Limit the QP buffer size when using "Dual Write" up to 128 WQEs.  | |
Keywords: Dual-write, QP  | |
Discovered in Version: 28.36.1010  | |
2348641  | Description: SFP 1G-BaseT transceivers are currently not supported.  | 
Workaround: N/A  | |
Keywords: SFP 1G-BaseT transceivers  | |
Discovered in Version: 28.35.1012  | |
3178339  | Description: PCIe PML1 is disabled.  | 
Workaround: N/A  | |
Keywords: PCIe PML1  | |
Discovered in Version: 28.35.1012  | |
3138665  | Description: PLDM firmware update process fails in case 1304 bytes chunk size is chosen.  | 
Workaround: N/A  | |
Keywords: PLDM firmware update  | |
Discovered in Version: 28.34.4000  | |
3110297  | Description: When ConnectX-7 adapter card is configured to use the Auto-Negotiation mode, 400G_8x linkup cannot be raised.  | 
Workaround: Configure the adapter card to use Force mode.  | |
Keywords: 400G_8x, linkup  | |
Discovered in Version: 28.34.4000  | |
3033910  | Description: BAR misses caused by a memory write/read actions are not reported in the AER and the device status.  | 
Workaround: N/A  | |
Keywords: BAR miss, AER  | |
Discovered in Version: 28.34.4000  | |
3140645  | Description: 3rd party servers may hang after warm reboot due to the PCIe switch.  | 
Workaround: N/A  | |
Keywords: PCIe, 3rd party servers  | |
Discovered in Version: 28.34.4000  | |
-  | Description: Changing dynamic PCIe link width is not supported.  | 
Workaround: N/A  | |
Keywords: PCIe  | |
Discovered in Version: 28.34.1002  | |
3174038  | Description: SPDM requests received while CPLD burn flow is in progress may be answered with incorrect responses.  | 
Workaround: Avoid activation of the two flows in tandem.  | |
Keywords: SPDM  | |
Discovered in Version: 28.34.1002  | |
3141072  | Description: The "max_shaper_rate" configuration query via QEEC mlxreg returns a value translated to hardware granularity.  | 
Workaround: N/A  | |
Keywords: RX Rate-Limiter, Multi-host  | |
Discovered in Version: 28.34.1002  | |
2870970  | Description: GTP encapsulation (flex parser profile 3) is limited to the NIC domain. Encapsulating in the FDB domain will render a 0-size length in GTP header.  | 
Workaround: N/A  | |
Keywords: GTP encapsulation  | |
Discovered in Version: 28.34.1002  | |
3081264  | Description: 10G/40G speeds are not supported on MFS1S00-XXXX modules (200G optics) in ConnectX-7 adapter cards.  | 
Workaround: N/A  | |
Keywords: Optical cables  | |
Discovered in Version: 28.33.4030  | |
3070590  | Description: PLL modules are not supported in ConnectX-7 ethernet adapter cards.  | 
Workaround: N/A  | |
Keywords: PLL  | |
Discovered in Version: 28.33.4030  | |
3073517  | Description: When connecting a ConnectX-7 adapter card to a ConnectX-5 or an NVIDIA Spectrum switch and trying to raise 10G/40G over 100G optics cable is not supported.  | 
Workaround: N/A  | |
Keywords: Optical cables, ConnectX-5, NVIDIA Spectrum  | |
Discovered in Version: 28.33.4030  | |
3070409  | Description: When connecting a ConnectX-7 adapter card to a ConnectX-6 Dx or an NVIDIA Spectrum-3 switch, NRZ speeds are not raised when using 200GbE optical cable.  | 
Workaround: Configure PHY_FEC_OVERRIDE on the ConnectX-7 side for the requested speed.  | |
Keywords: Optical cables, NRZ, ConnectX-6 Dx, NVIDIA Spectrum-3, 200GbE optical cable  | |
Discovered in Version: 28.33.4030  | |
2993531  | Description: PML1 is disabled by default. Enabling it might result in server hanging.  | 
Workaround: N/A  | |
Keywords: PML1  | |
Discovered in Version: 28.33.2028  | |
-  | Description: Upgrading to firmware 28.33.2028 from any previous Engineering Sample (earlier than version 28.98.2406) must be done before installing WinOF-2 v2.90 driver and requires going through the following steps: 
  | 
Workaround: N/A  | |
Keywords: Firmware upgrade  | |
Discovered in Version: 28.33.2028  | |
-  | Description: Downgrading from firmware 28.33.2028 to any previous Engineering Sample firmware is not supported.  | 
Workaround: N/A  | |
Keywords: Firmware downgrade  | |
Discovered in Version: 28.33.2028  |