Known Issues
The following is a list of general limitations and known issues of the various components of the Inbox Driver release.
|
Internal Ref. |
Issue |
|
3344305 |
Description: Enabling both UPT VFs and SR-IOV VFs on the same host will result in IOMMU fault. |
| Workaround: N/A | |
| Keywords: UPT SR-IOV | |
| Adapter Cards / DPU: NVIDIA BlueField-2 for VMware Monterey | |
| Available in OS: ESXi 8.0 | |
| Discovered in Version: 4.23.0.36 | |
|
- |
Description: Enabling VMDirectPath I/O pass-through of the first interface is not supported. |
| Workaround: N/A | |
| Keywords: Pass-through | |
| Adapter Cards / DPU: NVIDIA BlueField-2 for VMware Monterey | |
| Available in OS: ESXi 8.0 | |
| Discovered in Version: 4.23.0.36 | |
|
3308850 |
Description: To create 126 UPT devices, the following configuration needs to be set manually: |
| Workaround: N/A | |
| Keywords: UPT | |
| Adapter Cards / DPU: NVIDIA BlueField-2 for VMware Monterey | |
| Available in OS: ESXi 8.0 | |
| Discovered in Version: 4.23.0.36 | |
|
2678029 |
Description: Due to hardware limitations, Model 1 Level 2 and Model 2 for Enhanced Network Stack (ENS) mode in vSphere 8.0 is not supported in ConnectX-5 and ConnectX-6 adapter cards. |
| Workaround: Use ConnectX-6 Lx, ConnectX-6 Dx, or onwards cards that support ENS Model 1 Level 2 and Model 2A. | |
| Keywords: ENS, ConnectX-5/ConnectX-6, Model 1 Level 2 and Model 2A | |
| Adapter Cards / DPU: ConnectX-4 Onwards HCAs | |
| Available in OS: ESXi 7.0u3, ESXi 7.0u2 | |
| Discovered in Version: 4.23.0.36 | |
|
3192250 |
Description: The following error in logs may appear when performing DFW HW offload: "HW state is LAST_ACK while both sides sent an ACK". This message is harmless and can be ignored. |
| Workaround: N/A | |
| Keywords: DFW, offload, DPU | |
| Adapter Cards / DPU: NVIDIA BlueField-2 for VMware Monterey | |
| Available in OS: ESXi 8.0 | |
| Discovered in Version: 4.23.0.36 | |
|
3038613 |
Description: On DPU, the following error message can appear upon driver loading: "ECPF is not EswManager, cannot get SF support on host". This message is harmless and can be ignored. |
| Workaround: N/A | |
| Keywords: Error, log | |
| Adapter Cards / DPU: NVIDIA BlueField-2 for VMware Monterey | |
| Available in OS: ESXi 8.0 | |
| Discovered in Version: 4.23.0.36 | |
|
3175465 |
Description: The driver version in iDRAC is not displayed correctly. |
| Workaround: N/A | |
| Keywords: iDRAC | |
| Adapter Cards / DPU: NVIDIA BlueField-2 for VMware Monterey, ConnectX-4 Onwards HCAs | |
| Available in OS: ESXi 8.0, ESXi 7.0u3, ESXi 7.0u2, ESXi 7.0u1, ESXi 7.0, ESXi 6.7u2, ESXi 6.7 | |
| Discovered in Version: 4.23.0.36 | |
|
- |
Description: Geneve options length support is limited to 56B. Received packets with options length bigger than 56B are dropped. |
| Workaround: N/A | |
| Keywords: Geneve | |
| Adapter Cards / DPU: NVIDIA BlueField-2 for VMware Monterey, ConnectX-4 Onwards HCAs | |
| Available in OS: ESXi 8.0, ESXi 7.0u3, ESXi 7.0u2, ESXi 7.0u1, ESXi 7.0, ESXi 6.7u2, ESXi 6.7 | |
| Discovered in Version: 4.23.0.36 | |
|
- |
Description: The hardware can offload only up to 256B of headers. |
| Workaround: N/A | |
| Keywords: Hardware offload | |
| Adapter Cards / DPU: NVIDIA BlueField-2 for VMware Monterey, ConnectX-4 Onwards HCAs | |
| Available in OS: ESXi 8.0, ESXi 7.0u3, ESXi 7.0u2, ESXi 7.0u1, ESXi 7.0, ESXi 6.7u2, ESXi 6.7 | |
| Discovered in Version: 4.23.0.36 | |
|
2204581 |
Description: A mismatch between the uplink and the VF MTU values may result in CQE with error. |
| Workaround: Align the uplink and the VF MTU values. | |
| Keywords: CQE, error, model 2, | |
| Adapter Cards / DPU: NVIDIA BlueField-2 for VMware Monterey, ConnectX-4 Onwards HCAs | |
| Available in OS: ESXi 8.0, ESXi 7.0u3, ESXi 7.0u2, ESXi 7.0u1, ESXi 7.0, ESXi 6.7u2, ESXi 6.7 | |
| Discovered in Version: 4.23.0.36 | |
|
2429623 |
Description: Enabling sriov_mc_isolation module parameter may result in vmknic and emulated NICs multicast and IPv6 traffic loss. |
| Workaround: Unset or set the module parameter to 0. | |
| Keywords: Multicast, IPv6, SR-IOV | |
| Adapter Cards / DPU: NVIDIA BlueField-2 for VMware Monterey, ConnectX-4 Onwards HCAs | |
| Available in OS: ESXi 8.0, ESXi 7.0u3, ESXi 7.0u2, ESXi 7.0u1, ESXi 7.0, ESXi 6.7u2, ESXi 6.7 | |
| Discovered in Version: 4.23.0.36 | |
|
2372060 |
Description: RDMA is not supported in the Hypervisor with ENS model 2. |
| Workaround: N/A | |
| Keywords: ENS model 2, RDMA | |
| Adapter Cards / DPU: NVIDIA BlueField-2 for VMware Monterey, ConnectX-4 Onwards HCAs | |
| Available in OS: ESXi 8.0, ESXi 7.0u3, ESXi 7.0u2, ESXi 7.0u1, ESXi 7.0, ESXi 6.7u2, ESXi 6.7 | |
| Discovered in Version: 4.23.0.36 | |
|
2139469 |
Description: Setting the "Allow Guest MTU Change" option in vSphere Client is currently not functional. Although guest MTU changes in SR-IOV are allowed, they do not affect the port's MTU and the guest's MTU remains the same as the PF MTU. |
| Workaround: N/A | |
| Keywords: MTU, SR-IOV | |
| Adapter Cards / DPU: NVIDIA BlueField-2 for VMware Monterey, ConnectX-4 Onwards HCAs | |
| Available in OS: ESXi 8.0, ESXi 7.0u3, ESXi 7.0u2, ESXi 7.0u1, ESXi 7.0, ESXi 6.7u2, ESXi 6.7 | |
| Discovered in Version: 4.23.0.36 | |
|
1340255 |
Description: ECN statistic counters accumulatorsPeriod and ecnMarkedRocePackets display wrong values and cannot be cleared. |
| Workaround: N/A | |
| Keywords: nmlx5 ecn nmlxcli | |
| Adapter Cards / DPU: NVIDIA BlueField-2 for VMware Monterey, ConnectX-4 Onwards HCAs | |
| Available in OS: ESXi 8.0, ESXi 7.0u3, ESXi 7.0u2, ESXi 7.0u1, ESXi 7.0, ESXi 6.7u2, ESXi 6.7 | |
| Discovered in Version: 4.23.0.36 | |
|
1340275 |
Description: ECN tunable parameter initialAlphaValue for the Reaction Point protocol cannot be modified. |
| Workaround: N/A | |
| Keywords: nmlx5 ecn nmlxcli | |
| Adapter Cards / DPU: NVIDIA BlueField-2 for VMware Monterey, ConnectX-4 Onwards HCAs | |
| Available in OS: ESXi 8.0, ESXi 7.0u3, ESXi 7.0u2, ESXi 7.0u1, ESXi 7.0, ESXi 6.7u2, ESXi 6.7 | |
| Discovered in Version: 4.23.0.36 | |
|
2430662 |
Description: Card's speed remains zero after port goes down and reboot is performed. |
| Workaround: Turn the port down and then up again. | |
| Keywords: ConnectX-6 Dx, link speed | |
| Adapter Cards / DPU: NVIDIA BlueField-2 for VMware Monterey, ConnectX-4 Onwards HCAs | |
| Available in OS: ESXi 8.0, ESXi 7.0u3, ESXi 7.0u2, ESXi 7.0u1, ESXi 7.0, ESXi 6.7u2, ESXi 6.7 | |
| Discovered in Version: 4.23.0.36 | |
|
1514289 |
Description: RoCE traffic may fail after vMotion when using namespace. |
| Workaround: N/A | |
| Keywords: Namespace, RoCE, vMotion | |
| Adapter Cards / DPU: NVIDIA BlueField-2 for VMware Monterey, ConnectX-4 Onwards HCAs | |
| Available in OS: ESXi 8.0, ESXi 7.0u3, ESXi 7.0u2, ESXi 7.0u1, ESXi 7.0, ESXi 6.7u2, ESXi 6.7 | |
| Discovered in Version: 4.23.0.36 | |
|
2334405 |
Description: Legacy SR-IOV is not supported with Model 1. |
| Workaround: Unset max_vfs or alternatively move to ENS model 0 or Model 2. | |
| Keywords: SR-IOV, ENS | |
| Adapter Cards / DPU: NVIDIA BlueField-2 for VMware Monterey, ConnectX-4 Onwards HCAs | |
| Available in OS: ESXi 8.0, ESXi 7.0u3, ESXi 7.0u2, ESXi 7.0u1, ESXi 7.0, ESXi 6.7u2, ESXi 6.7 | |
| Discovered in Version: 4.23.0.36 | |
|
2449578 |
Description: When in ENS mode, changing the scheduler to HCLK, may cause traffic loss. |
| Workaround: N/A | |
| Keywords: ENS, HCLK scheduler | |
| Adapter Cards / DPU: NVIDIA BlueField-2 for VMware Monterey, ConnectX-4 Onwards HCAs | |
| Available in OS: ESXi 8.0, ESXi 7.0u3, ESXi 7.0u2, ESXi 7.0u1, ESXi 7.0, ESXi 6.7u2, ESXi 6.7 | |
| Discovered in Version: 4.23.0.36 | |
|
746100 |
Description: The 'esxcli mellanox uplink link info -u <vmnic_name>' command reports the 'Auto negotiation' capability always as 'true'. |
| Workaround: N/A | |
| Keywords: 'Auto negotiation' capability | |
| Adapter Cards / DPU: NVIDIA BlueField-2 for VMware Monterey, ConnectX-4 Onwards HCAs | |
| Available in OS: ESXi 8.0, ESXi 7.0u3, ESXi 7.0u2, ESXi 7.0u1, ESXi 7.0, ESXi 6.7u2, ESXi 6.7 | |
| Discovered in Version: 4.23.0.36 | |
|
1068621 |
Description: SMP MADs (ibnetdiscover, sminfo, iblinkinfo, smpdump, ibqueryerr, ibdiagnet and smpquery) are not supported on the VFs. |
| Workaround: N/A | |
| Keywords: SMP MADs | |
| Adapter Cards / DPU: NVIDIA BlueField-2 for VMware Monterey, ConnectX-4 Onwards HCAs | |
| Available in OS: ESXi 8.0, ESXi 7.0u3, ESXi 7.0u2, ESXi 7.0u1, ESXi 7.0, ESXi 6.7u2, ESXi 6.7 | |
| Discovered in Version: 4.23.0.36 | |
|
1446060 |
Description: Although the max_vfs module parameter range is "0-128", due to firmware limitations, the following are the supported VFs per single port devices:
|
| Workaround: N/A | |
| Keywords: SR-IOV, VFs per port | |
| Adapter Cards / DPU: ConnectX-4 Onwards HCAs | |
| Available in OS: ESXi 7.0u3, ESXi 7.0u2, ESXi 7.0u1, ESXi 7.0, ESXi 6.7u2, ESXi 6.7 | |
| Discovered in Version: 4.23.0.36 | |
|
2139469 |
Description: Setting the "Allow Guest MTU Change" option in vSphere Client is currently not functional. Although guest MTU changes in SR-IOV are allowed, they do not affect the port's MTU and the guest's MTU remains the same as the PF MTU. |
| Workaround: N/A | |
| Keywords: MTU, SR-IOV | |
| Adapter Cards / DPU: NVIDIA BlueField-2 for VMware Monterey | |
| Available in OS: ESXi 8.0 | |
| Discovered in Version: 4.23.0.36 | |
|
2813820 |
Description: The maximum supported VFs in the case of Model 3 (A and B) setup is 126. |
| Workaround: Set the maximum value of NUM_OF_VFS to 126 in mlxconfig. | |
| Keywords: VFs, Model 3 | |
| Adapter Cards / DPU: NVIDIA BlueField-2 for VMware Monterey | |
| Available in OS: ESXi 8.0 | |
| Discovered in Version: 4.23.0.36 | |
|
2615605 |
Description: LAG creation fails when VFs are enabled on the host. |
| Workaround: Before adding a second uplink to the switch, make sure all VMs with VFs are powered off. | |
| Keywords: Link Aggregation | |
| Adapter Cards / DPU: NVIDIA BlueField-2 for VMware Monterey | |
| Available in OS: ESXi 8.0 | |
| Discovered in Version: 4.23.0.36 | |
|
2611342 |
Description: On older version of iDRAC, the NC-SI channel is not opened automatically. |
|
Workaround: Run this command from the iDrac root SHEll manually and open the channel after every reboot or Arm OS libncsitest 47 eth2 0 2 <MAC addr of sd0> <MAC addr of sd0> |
|
| Keywords: iDRAC Communication | |
| Adapter Cards / DPU: NVIDIA BlueField-2 for VMware Monterey | |
| Available in OS: ESXi 8.0 | |
| Discovered in Version: 4.23.0.36 | |
|
- |
Description: Adapter cards that come with a pre-configured link type as InfiniBand cannot be detected by the driver and cannot be seen by MFT tools. Thus its link type cannot be changed. |
Workaround:
|
|
| Keywords: Link type, InfiniBand, MFT | |
| Adapter Cards / DPU: ConnectX-4 Onwards HCAs | |
| Available in OS: ESXi 7.0u3, ESXi 7.0u2, ESXi 7.0u1, ESXi 7.0, ESXi 6.7u2, ESXi 6.7 | |
|
Discovered in versions: 4.17.13.10-vmw, 4.17.13.1-vmw, 4.17.16.8-vmw, 4.17.16.7-vmw, 4.17.9.12-vmw |