Changes and New Features History
This section includes history of changes and new feature of 3 major releases back. For older releases history, please refer to the relevant firmware versions.
Category |
Description |
11.2008.1904 |
|
General |
Stability Improvements. |
11.2008.1604 |
|
General |
Stability Improvements. |
11.2008.1300 |
|
General |
Stability Improvements. |
11.2008.0236 |
|
General |
Stability Improvements. |
Power Supply |
Delta 550W Power Supply is now backward compatible with Delta 460W PSU. |
11.2007.0300 |
|
Performance |
Added support for link-negotiated credit size. |
11.2000.3276 |
|
Power Supply |
Added support for Delta 550m Power Supply. |
11.2000.2626 |
|
General |
Added support for Error Injection with PTER register. |
Speed Link |
SDR link speed on InfiniBand systems is now available for all cables, including cables that do not advertise InfiniBand speed in their memory map. |
11.2000.2046 |
|
Link up time |
Link up time stability |
11.2000.1600 |
|
Bug Fixes |
See Bug Fixes History. |
11.2000.1000 |
|
Chassis Management |
Changed the PSU voltage read from “Vout” to “Vin”. |
General |
System stability improvements. |
11.19100.0618 |
|
General |
Added support for PortStateTable standard SMP MAD. |
Chassis Management |
Added support for PSU utilization and consumption of output power. |
Chassis Management |
Added support for PSU temperature and 12V Vout monitoring. |
11.1701.0010 |
|
General |
Added support for congestion control log 1.3 as described in IBTA IB specification release 1.3, Annex A10. |
General |
Added additional information (PDDR pages as described in the Switches PRM, section 8.15.50 PDDR - Port Diagnostics Database Register) to diagnostics data VS-MAD as described in Mellanox Vendor Specific MAD Specification 1.3 section 3.33 – DiagnosticData. |
Chassis Management |
Added ability to read part numbers and serial numbers for fans (by using MFNR register) and the power supply (by using MSPS register). |
11.1610.0206 |
|
General |
Bug fixes |
11.1610.0196 |
|
General |
Added support for congestion control log 1.3 as described in IBTA IB specification release 1.3, Annex A10. |
General |
Added additional information (PDDR pages as described in the Switches PRM, section 8.15.50 PDDR - Port Diagnostics Database Register) to diagnostics data VS-MAD as described in Mellanox Vendor Specific MAD Specification 1.4 section 3.33 – DiagnosticData. |
SHARP |
Added support for group join optimization using root GID as described in Mellanox Vendor Specific MAD Specification 1.4 section 4.10 – Aggregation Group Join. |