The following sections describe known issues in firmware releases and possible workarounds.
Internal Ref. |
Issue |
955641 |
Description: VL_HIGH_LIMIT is not affecting the VL arbiter as expected. |
Workaround: Arbitration table should be set using only the low priority VL arbitration table |
|
Keywords: VL Arbitration |
|
1249608 |
Description: Configuring weight “0” for VL, results in unexpected behavior. |
Workaround: Arbitration table should be configured with weights other than “0”. |
|
Keywords: VL Arbitration |
|
982005 |
Description: When connecting 6 & 7 meters, link may raise DDR instead of QDR against GD4000/IS5000 switches. |
Workaround: N/A |
|
Keywords: Link |
|
- |
Description: Congestion Control 1.3 supports congestion log only. |
Workaround: N/A |
|
Keywords: QoS |
|
- |
Description: Port LEDs do not flash on system boot. |
Workaround: N/A |
|
Keywords: LEDs |
|
- |
Description: Link width reduction is not supported in this release. |
Workaround: N/A |
|
Keywords: Power Management |
|
- |
Description: If QDR is not enabled for the switch's InfiniBand Port Speed while connected to ConnectX-3/Pro or Connect-IB® FDR adapters or to SwitchX® /SwitchX®-2 FDR switches, links will rise at SDR or DDR (even if FDR is enabled). |
Workaround: Enable QDR (in addition to FDR) when connecting to peer ports running at FDR |
|
Keywords: Interoperability |
|
- |
Description: Force FDR10 is not supported on EDR products. |
Workaround: To raise link with an FDR10 device, make sure all speeds, including EDR, are configured on Switch-IB. |
|
Keywords: Interoperability |
|
- |
Description: Fallback Routing is not supported for DF+ topology. Fallback Routing Notifications and Adaptive Routing notifications are not supported for topologies others then trees. |
Workaround: N/A |
|
Keywords: Network |
|
697149 |
Description: Link rises at DDR speed instead of FDR10 when using 100m QDR/FDR10 optical cables. |
Workaround: N/A |
|
Keywords: Link |
|
- |
Description: FDR link may rise with symbol errors on optic EDR cable longer than 30M. |
Workaround: N/A |
|
Keywords: Link |
|
- |
Description: Fan LEDs may behave unexpectedly in the first 5 seconds of system boot. |
Workaround: N/A |
|
Keywords: LEDs |
|
- |
Description: Module info page in Diagnostics Data VS-MAD is not supported |
Workaround: N/A |
|
Keywords: Diagnostics Data VS-MAD |