NVIDIA MLNX-OS User Manual v3.11.2002
NVIDIA MLNX-GW User Manual for NVIDIA Skyway Appliance v8.2.2200

Chassis Management Commands

clear counters

clear counters [all | interface <type> <number>]

Clears switch counters.

Syntax Description

all

Clears all switch counters.

type

A specific interface type.

number

The interface number.

Default

N/A

Configuration Mode

config

History

3.2.3000

3.6.4000: Added note

Example

switch (config) # clear counters

Related Commands

Notes

The command also clears storm-control counters


health

health {max-report-len <length> | re-notif-cntr <counter> | report-clear}

Configures health daemon settings.

Syntax Description

max-report-len <length>

Sets the length of the health report ( number of line entries)

Range: 10-2048

re-notif-cntr <counter>

Health control changes notification counter in seconds

Range: 120-7200

report-clear

Clears the health report

Default

max-report-len: 50

re-notif-cntr:

Configuration Mode

config

History

3.1.0000

Example

switch (config) # health re-notif-cntr 125

Related Commands

show health-report

Notes


led uid

led <module> uid <on | off>

Configures the UID LED.

Syntax Description

module

Specifies the module whose UID LED to configure

on

Turns on UID LED

off

Turns off UID LED

Default

N/A

Configuration Mode

config

History

3.6.1002

3.6.2002: Added modular switch support

Example

switch (config) # led MGMT uid on

Related Commands

Notes

  • On 1U switch systems, the module parameter can only be MGMT

  • On modular switch systems, the module parameter may be MGMT#, L#, S# (e.g. MGMT1, L01, S01)

power enable

power enable <module name>

no power enable <module name>

Powers on the module.

The no form of the command shuts down the module.

Syntax Description

module name

Enables power for selected module

Default

Power is enabled on all modules

Configuration Mode

config

History

3.1.0000

Example

switch (config) # power enable L01

Related Commands

show power

show power consumers

Notes

  • It is recommended to run this command prior to extracting a module from the switch system, else errors are printed in the log

  • This command is not applicable on 1U systems

system manage inband-ib

system manage inband-ib

no system manage inband-ib

Enables remote inband management of the system.

The no form of the command disables remote inband management of the system.

Syntax Description

N/A

Default

N/A

Configuration Mode

config

History

3.8.1000

Example

switch (config) # system manage inband-ib

Related Commands

show system manage inband-ib

Notes

This command is available only on Quantum based switch systems


power redundancy-mode

power redundancy-mode [combined | grid-redundant | ps-redundant]

no power redundancy-mode

Controls the power supply redundancy mode.

The no form of the command resets power redundancy mode to the default value.

Syntax Description

combined

No redundancy – no alarm threshold

grid-redundant

N+N – the alarm threshold will be set to a level, indicating when the power availability falls below power that can support N+N scheme

ps-redundant

N+1 – the alarm threshold will be set to a level, indicating when the power availability falls below power that can support N+1 scheme

Default

N/A

Configuration Mode

config

History

3.2.0000

3.10.1000: Added the no form of the command

Example

switch (config) # power redundancy-mode combined

Related Commands

Notes

  • The difference between the modes sets the threshold for power supply redundancy failure. It does not change any power supply configuration.

  • This command is not applicable for 1U or blade systems.

system profile

system profile {ib-single-switch | ib-no-adaptive-routing-single-switch | ib [split-ready] [num-of-swids <swid-num>] [no-adaptive-routing] [ib-router] [adaptive-routing-groups <value>]} [force]

Sets the profile of the system to InfiniBand with various parameters

Syntax Description

ib-single-switch

Enables InfiniBand switch profile

All network interfaces link protocol set to InfiniBand

ib-no-adaptive-routing-single-switch

Enables InfiniBand switch profile without adaptive routing capabilities

All network interfaces link protocol set to InfiniBand with disabled adaptive routing

split-ready

Enables the system to reboot in split enable mode with capability to configure 2x the number of ports exposed to IB utilities.

Note: This parameter is available only on Quantum-based systems.

ib-router

Enables IB Routing capability on the system

num-of-swids

Multiple switch IDs are configurable

  • adaptive routing—enables adaptive routing

  • ib-router—enables IB router

Note: If num-of-swids is not defined then it is set to 1 by default.

no-adaptive-routing

Disables adaptive routing

adaptive-routing-groups

Sets adaptive routing groups.

Warning

Allowed only when adaptive routing is enabled.

Default

The default system profile depends on the system.

Configuration Mode

config

History

3.1.0000

3.2.1100: Added “vpi-single-switch” option

3.3.4100: Added SX6036G3.3.4302Added system profile ib-no-adaptive-routing-single-switch

3.6.1002: Added system profile “ib num-of-swids”

3.6.6162: Added system profile “num of adaptive routing”

3.7.0020: Added system profile “ib split-ready” for 1U systems

3.8.1100: Updated syntax description for the parameter "adaptive-routing-groups"

3.9.0300: Added system profile “ib split-ready” for modular systems

3.9.2000: Updated note

3.10.6000: Updated note

Example

switch (config) # system profile ib-single-switch

Related Commands

port type

show system profile

show ports type

Notes

  • This command requires approval because reboot is performed and all configuration is removed

  • This command deletes all switch configuration (keeping configuration necessary for network connectivity such as interfaces, routes, and ARP) and resets the system

  • System profile “ib-no-adaptive-routing-single-switch profile” is the default profile for InfiniBand switches

  • The parameter “adaptive-routing-groups” is only available when “adaptive-routing” is configured

  • Refer to the “port type” command in order to change the link protocol

  • System profile “ib split-ready” must run together with num-of-swids 1

  • IB router and adaptive routing are enabled only if specified but cannot be enabled at the same time

  • IB router only works when adaptive routing is disabled.

  • In NDR systems, the maximum number of SWIDs is 8.


usb eject

usb eject

Turns off the USB interface gracefully.

Syntax Description

N/A

Default

N/A

Configuration Mode

config

History

3.1.0000

Example

switch (config) # usb eject

Related Commands

Notes

Applicable only for systems with USB interface.


show asic-version

show asic-version

Displays firmware ASIC version.

Syntax Description

N/A

Default

N/A

Configuration Mode

Any command mode

History

3.1.0000

3.4.2008: Updated example

Example

switch (config) # show asic-version

===================================================

Module Device Version

===================================================

L05 SIB2-1 15.0200.0092

L05 SIB2-2 15.0200.0092

Related Commands

Notes


show bios

show bios

Displays the BIOS version information.

Syntax Description

N/A

Default

N/A

Configuration Mode

Any command mode

History

3.3.4150

Example

switch (config) # show bios

BIOS version : 4.6.5

BIOS subversion : Official AMI Release

BIOS release date : 07/02/2021

Related Commands

Notes


show cpld

show cpld

Displays status of all CPLDs in the system.

Syntax Description

N/A

Default

N/A

Configuration Mode

Any command mode

History

3.1.0000

3.3.4302: Updated example

3.10.1000: Updated example to reflect the part number (PN) field

3.10.1100: Updated example to reflect Version Minor

Example

switch (config) # show cpld
    
----------------------------------------------------------------------------    

Name Type Version Version Minor PN

----------------------------------------------------------------------------

Cpld1 CPLD_TOR 9 1 0x0078

Cpld2 CPLD_SWB_UNIFIED 3 3 0x0128

Cpld3 CPLD_LED 1 0 0x00d1

Related Commands

Notes


show fan

show fan

Displays fans status.

Syntax Description

N/A

Default

N/A

Configuration Mode

Any command mode

History

3.1.0000

Example

switch (config) # show fan

-----------------------------------------------------

Module Device Fan Speed Status

(RPM)

-----------------------------------------------------

FAN1 FAN F1 6297.00 OK

FAN1 FAN F2 5421.00 OK

FAN2 FAN F1 6355.00 OK

FAN2 FAN F2 5378.00 OK

FAN3 FAN F1 6183.00 OK

FAN3 FAN F2 5421.00 OK

FAN4 FAN F1 6268.00 OK

FAN4 FAN F2 5399.00 OK

PS1 FAN F1 10336.00 OK

PS2 FAN - - NOT PRESENT

Related Commands

Notes


show health-report

show health-report

Displays health report.

Syntax Description

N/A

Default

N/A

Configuration Mode

Any command mode

History

3.1.0000

3.3.0000: Output update

3.11.2002: Output update

Example

switch (config) # show health-report

ALERTS CONFIGURATION

Re-notification counter (sec): [3600]

Report max counter : [50]

HEALTH REPORT

No Health issues file

Related Commands

health

Notes


show inventory

show inventory

Displays system inventory.

Syntax Description

N/A

Default

N/A

Configuration Mode

Any command mode

History

3.1.0000

3.4.1604: Removed CPU module output from example

3.5.1000: Removed Type column from example

3.6.1002: Updated example

Example

switch (config) # show inventory

-----------------------------------------------------------------------

Module Part Number Serial Number Asic Rev. HW Rev.

-----------------------------------------------------------------------

CHASSIS MSB7800-ES2F MT1602X17464 N/A A1

MGMT MSB7800-ES2F MT1602X17464 0 A1

FAN1 MTEF-FANF-A MT1602X16943 N/A A3

FAN2 MTEF-FANF-A MT1602X16944 N/A A3

FAN3 MTEF-FANF-A MT1602X16956 N/A A3

FAN4 MTEF-FANF-A MT1602X16957 N/A A3

PS1 MTEF-PSF-AC-A MT1601X09908 N/A A3

Related Commands

Notes


show leds

show leds [<module>]

Displays the LED status of the switch system.

Syntax Description

module

Specifies the module whose LED status to display

Default

N/A

Configuration Mode

Any command mode

History

3.6.1002

3.6.2002: Updated example

Example

switch (config) # show leds

Module LED Status

--------------------------------------------

MGMT1 STATUS Green

MGMT1 REAR_FAN Green

MGMT1 PS Green

MGMT1 FRONT_FAN Green

MGMT1 MASTER/SLAVE Green

L01 STATUS Green

L01 UID Blue

L02 STATUS Green

L02 UID Blue

L03 STATUS Green

L03 UID Off

L04 STATUS Green

L04 UID Off

L05 STATUS Green

L05 UID Off

L06 STATUS Green

L06 UID Off

S01 STATUS Green

S01 FAN Green

S02 STATUS Green

S02 FAN Green

S03 STATUS Green

S03 FAN Green

FAN1 STATUS Green

FAN2 STATUS Green

FAN3 STATUS Green

FAN4 STATUS Green

Related Commands

Notes


show memory

show memory

Displays memory status.

Syntax Description

N/A

Default

N/A

Configuration Mode

Any command mode

History

3.1.0000

3.7.1000: Updated example

Example

switch (config) # show memory
-----------------------------------------------------------------------

Memory Space Total Used Free Used+B/C Free-B/C

-----------------------------------------------------------------------

Physical 15848 MB 2849 MB 12999 MB 3854 MB 11994 MB

Swap 0 MB 0 MB 0 MB

Physical Memory Borrowed for System Buffers and Cache:

Buffers : 27 MB

Cache : 910 MB

Total Buffers/Cache: 937 MB

Related Commands

Notes


show module

show module

Displays modules status.

Syntax Description

N/A

Default

N/A

Configuration Mode

Any command mode

History

3.1.0000

3.3.0000: Added “Is Fatal” column

3.4.2008: Updated command output

3.4.3000: Updated command output and added note

Example

switch (config) # show module

======================

Module Status

======================

MGMT ready

FAN1 ready

FAN2 ready

PS1 ready

PS2 not-present

Related Commands

Notes

The Status column may have one of the following values: error, fatal, not-present, powered-off, powered-on, ready.


show power

show power

Displays power supplies and power usage.

Syntax Description

N/A

Default

N/A

Configuration Mode

Any command mode

History

3.1.0000

3.5.1000: Updated example

Example

switch (config) # show power
----------------------------------------------------------------------------------

Module Device Sensor Power Voltage Current Capacity Feed Status

[Watts] [Volts] [Amp] [Watts]

----------------------------------------------------------------------------------

PS1 power-mon input 32.25 12.11 1.26 800.00 DC OK

PS2 power-mon input 46.56 12.13 2.33 800.00 DC OK

Related Commands

Notes


show power consumers

show power consumers

Displays power consumption information.

Syntax Description

N/A

Default

N/A

Configuration Mode

Any command mode

History

3.1.0000

3.5.1000: Updated example

Example

switch (config) # show power consumers
-------------------------------------------------------------------------

Module Device Sensor Power Voltage Current Status

[Watts] [Volts] [Amp]

-------------------------------------------------------------------------

MGMT CURR_MONITOR 12V 52.96 11.71 4.52 OK

PS1 power-mon input 252.00 12.00 20.25 OK

PS2 power-mon input 280.00 12.03 23.25 OK

Total power used : 52.96 Watts

Related Commands

Notes


show protocols

show protocols

Displays all protocols enabled in the system.

Syntax Description

N/A

Default

N/A

Configuration Mode

Any command mode

History

3.2.3000

3.3.4550: Updated example

3.6.1002: Updated example

Example

switch (config) # show protocols

Infiniband enabled

sm enabled

router disabled

Related Commands

Notes


show resources

show resources

Displays system resources.

Syntax Description

N/A

Default

N/A

Configuration Mode

Any command mode

History

3.1.0000

Example

switch (config) # show resources

Total Used Free

Physical 2027 MB 761 MB 1266 MB

Swap 0 MB 0 MB 0 MB

Number of CPUs: 1

CPU load averages: 0.11 / 0.23 / 0.23

CPU 1

Utilization: 5%

Peak Utilization Last Hour: 19% at 2012/02/15 13:26:19

Avg. Utilization Last Hour: 7%

Related Commands

Notes


show system capabilities

show system capabilities

Displays system capabilities.

Syntax Description

N/A

Default

N/A

Configuration Mode

Any command mode

History

3.1.0000

3.3.0000: Added gateway support

3.6.1002: Updated example

3.7.0000: Updated example

Example

switch (config) # show system capabilities

IB: Supported, L2, Adaptive Routing, Split Ready

Max SM nodes: 648

IB Max licensed speed: EDR

Related Commands

show system profile

Notes


show system manage inband-ib

show system manage inband-ib

Displays whether inband management over InfiniBand is currently allowed.

Syntax Description

N/A

Default

N/A

Configuration Mode

Any command mode

History

3.8.1000

Example

switch (config) # show system manage inband-ib

Manage inband-ib: no

Related Commands

system manage inband-ib

Notes

This command is available only on Quantum based switch systems


show system profile

show system profile

Displays system profile.

Syntax Description

N/A

Default

N/A

Configuration Mode

Any command mode

History

3.2.0000

3.7.0000: Updated example

Example

switch (config) # show system profile

Profile : ib

Number of SWIDs : 1

Adaptive Routing : yes

Adaptive Routing Groups : 2048

IB Routing : no

Related Commands

system profile

Notes


show system type

show system type

Displays system type.

Syntax Description

N/A

Default

N/A

Configuration Mode

Any command mode

History

3.5.1000

Example

switch (config) # show system type

SB7700

Related Commands

Notes


show temperature

show temperature

Displays system temperature sensors status.

Syntax Description

N/A

Default

N/A

Configuration Mode

Any command mode

History

3.1.0000

Example

switch (config) # show temperature

---------------------------------------------------------

Module Component Reg CurTemp Status

(Celsius)

---------------------------------------------------------

MGMT SIB2 T1 32.00 OK

MGMT Board AMB temp T1 23.50 OK

MGMT Ports AMB temp T1 27.50 OK

MGMT CPU package Sensor T1 27.00 OK

MGMT CPU Core Sensor T1 18.00 OK

MGMT CPU Core Sensor T2 27.00 OK

PS1 power-mon T1 22.50 OK

Related Commands

Notes


show version

show version

Displays version information for the currently running system image.

Syntax Description

N/A

Default

N/A

Configuration Mode

Any command mode

History

3.1.0000

Example

switch (config) # show version
Product name:      MLNX-OS

Product release: 3.11.1954-007

Build ID: #1-dev

Build date: 2023-10-18 15:21:05

Target arch: x86_64

Target hw: x86_64

Version summary: X86_64 3.11.1954-007 2023-10-18 15:21:05 x86_64

Product model: x86onie

Host ID: 0C42A117E840

System serial num: MT2006X07803

System UUID: 62cbd568-7d2a-11ea-8000-0c42a1589d10

Uptime: 17h 1m 3.828s

CPU load averages: 0.00 / 0.00 / 0.00

Number of CPUs: 4

System memory: 846 MB used / 6954 MB free / 7800 MB total

Swap: 0 MB used / 0 MB free / 0 MB total

Related Commands

Notes


show version concise

show version concise

Displays concise version information for the currently running system image.

Syntax Description

N/A

Default

N/A

Configuration Mode

Any command mode

History

3.1.0000

Example

switch (config) # show version concise

X86_64 3.6.4006 2017-07-03 16:17:39 x86_64

Related Commands

Notes


show voltage

show voltage

Displays voltage level measurements on different sensors.

Syntax Description

N/A

Default

N/A

Configuration Mode

Any command mode

History

3.1.0000

3.3.5006: Updated example

Example

switch (config) # show voltage
============================================================================================

Module Power Meter Reg Expected Actual Status High Low

Voltage Voltage Range Range

============================================================================================

MGMT BOARD_MONITOR USB 5V sensor 5.00 5.15 OK 5.55 4.45

MGMT BOARD_MONITOR Asic I/O sensor 2.27 2.11 OK 2.55 1.99

MGMT BOARD_MONITOR 1.8V sensor 1.80 1.79 OK 2.03 1.57

MGMT BOARD_MONITOR SYS 3.3V sensor 3.30 3.28 OK 3.68 2.92

MGMT BOARD_MONITOR CPU 0.9V sensor 0.90 0.93 OK 1.04 0.76

MGMT BOARD_MONITOR 1.2V sensor 1.20 1.19 OK 1.37 1.03

MGMT CPU_BOARD_MONITOR 12V sensor 12.00 11.67 OK 13.25 10.75

MGMT CPU_BOARD_MONITOR 12V sensor 2.50 2.46 OK 2.80 2.20

MGMT CPU_BOARD_MONITOR 2.5V sensor 3.30 3.26 OK 3.68 2.92

MGMT CPU_BOARD_MONITOR SYS 3.3V sensor 3.30 3.24 OK 3.68 2.92

MGMT CPU_BOARD_MONITOR SYS 3.3V sensor 1.80 1.79 OK 2.03 1.57

MGMT CPU_BOARD_MONITOR 1.8V sensor 1.20 1.24 OK 1.37 1.03

Related Commands

Notes

chassis ha bip

chassis ha bip <board-ip-address>

Configures Chassis Board IP (BIP).

Syntax Description

board-ip-address

Sets the chassis virtual IP address

Default

0.0.0.0

Configuration Mode

config

History

3.1.0000

Example

switch (config) # chassis ha bip 192.168.10.100

Related Commands

show chassis ha

Notes

This command is applicable only for modular switch systems.


chassis ha

chassis ha reset other

Performs a reset to the other management card in the chassis.

Syntax Description

N/A

Default

N/A

Configuration Mode

config

History

3.1.0000

Example

switch (config) # chassis ha reset other

Related Commands

show chassis ha

Notes

This command is applicable only for modular switch systems.


chassis ha power enable other

chassis ha power enable other

no chassis ha power enable other

Enables the other management card in the chassis.

The no form of the command disables the other management card in the chassis.

Syntax Description

N/A

Default

The other management card is enabled

Configuration Mode

config

History

3.1.0000

Example

switch (config) # chassis ha power enable other

Related Commands

show chassis ha

Notes

This command is applicable only for modular switch systems.


show chassis ha

show chassis ha

Displays chassis HA parameters and status.

Syntax Description

N/A

Default

The other management card is enabled

Configuration Mode

Any command mode

History

3.1.0000

Example

switch (config) # show chassis ha

2-node HA state:

Box management IPv4: 10.7.146.44/24

Box management IPv6: fdfd:fdfd:7:145::1033:47fd/64

interface : mgmt0

local role : master

local slot : 1

other state : ready

reset count : 0

Related Commands

chassis ha

Notes

This command is applicable only for modular switch systems.


chassis ha bipv6

ch assis ha bipv6 {ipv6 address} {ipv6 mask length} [force]

The command configures the Box IPv6.

Syntax Description

ipv6 address

The ipv6 box ip

ipv6 mask length

The mask for IPv6 box ip

Default

The other management card is enabled

Configuration Mode

Any command mode

History

3.8.1200

Example

switch (config) # chassis ha bipv6 fdfd:fdfd:7:145::1033:47fd /64 

Related Commands

chassis ha

Notes


© Copyright 2023, NVIDIA. Last updated on Nov 6, 2023.