NVIDIA 01LL977 Air Duct and Rail Kit for IBM NDR Switch Systems Quick Installation Guide
NVIDIA 01LL977 Air Duct and Rail Kit for IBM NDR Switch Systems Quick Installation Guide

Installation and Configuration

Warning

The following steps include illustrations that show front side (ports) installation, yet all instructions apply to all installation options.

#

Illustration

1

Mount the systems rails (Part E) onto the chassis:

    1. Attach the switch to the left and right system rails (Part E).

    2. Secure the assembly by pushing the chassis’ pins through the slider key holes, until a click is heard and locking occurs.

2

Install 8 captive nuts (Part A, round or square), as shown in the illustration:

3

Mount the rack rails (Part D) onto the rack using screws B (2 screws per side):

*Do not tighten the screws yet.

image2022-11-7_14-46-55.png

4

    1. Slide the rails installed on the system into the channels in the rear rack rails.

    2. Tighten the rails (part E) to the rack, using screws B (2 screws per side).

*Route the required cables through the designated window (right/left/both). Plug the cables.

5

    1. Slide the air duct panel (Part C) towards the switch system.

    2. Tighten the captive screws on both sides to further secure the system to the rack's posts.

Connector (Front) Side

QM9700

image2022-7-25_16-52-9.png

QM9790

image2022-7-25_16-45-47.png

FRU (Rear) Side

* It may take up to five minutes to turn on the system.
If the System Status LED shows amber after five minutes, unplug the system and contact your NVIDIA representative.

** Certain systems have a single management port.

* It may take up to five minutes to turn on the system. If the System Status LED shows red/amber after five minutes, unplug the system and contact your NVIDIA representative.

LED Assignments

Symbol

Description

Normal Status

image2022-2-28_13-58-49.png

System health

Green/Flashing

image2022-2-28_13-59-22.png

Fan health

Green

image2022-2-28_14-0-26.png

Power supply health

Green

image2022-2-28_14-3-4.png

Identifier LED

Off/Blue

image2022-2-28_14-3-22.png

Reset button

  1. Connect the host PC to the Console (RJ-45) port.

  2. Configure a serial terminal program.

    Parameter

    Settings

    Baud rate

    115200

    Data bits

    8

    Stop bits

    1

    Parity

    None

    Flow control

    None

  3. Login:

    OS

    Username

    Password

    Onyx (MLNX-OS)

    admin

    admin

  4. Initial configuration in Onyx (MLNX-OS): Go through the configuration wizard. For further information, please refer to: https://docs.nvidia.com/networking/category/mlnxos.

For full installation instructions, go to https://docs.nvidia.com/networking/display/QM97X0PUB.