Installation and Configuration
# | Illustration |
1 | Attach parts D and E (x2 of each) to the switch. Push the switch chassis’ pins through the slider key holes, until locking occurs. Pay attention to the rack’s type. Short Racks (430-580mm): |
Standard Racks (580-800mm): | |
2 | Short Racks: |
Standard Racks: | |
3 | Install 8 cage nuts (B) in the desired 2U slots in the rack. |
4 | Do not tighten the screws yet. |
5 | |
6 | Tighten all 8 M6 (C) screws with a torque of 4.5±0.5 Nm. |
Connector (Front) Side |
FRU (Rear) Side |
* It may take up to five minutes to turn on the system. If the System Status LED shows amber after five minutes, unplug the system and contact your NVIDIA representative.
** Certain systems have a single management port.
LED Assignments
Symbol | Description | Normal Status |
System health | Green/Flashing | |
Fan health | Green | |
Power supply health | Green | |
Bad port detected | Off | |
Identifier LED | Off/Blue | |
Reset button |
Before installing the switch system, make sure an over-current DC circuit breaker of up to 100A is installed at the rack.
Connect the DC power supplies in the switch according to the following recommendations:
Make sure circuit breakers are in their “Off” state.
Ground the PSU with a 14 AWG wire.
Using an 8 AWG wire for the power feed, unscrew the screws on the DC PSU terminals, connect the DC power cord lugs, and tighten the screws.
Repeat all steps for secondary PSU.
Turn on the switch by switching the circuit breaker to the “On” position for both PSUs.
Connect the host PC to the Console (RJ-45) port.
Configure a serial terminal program.
Parameter
Settings
Baud rate
115200
Data bits
8
Stop bits
1
Parity
None
Flow control
None
Login:
OS
Username
Password
Onyx (MLNX-OS)
admin
admin
Cumulus Linux
cumulus
CumulusLinux! (case sensitive)
a. No login is required. Press Enter to activate the console.
Initial configuratio
For NVIDIA Onyx: Go through the configuration wizard. For further information, please refer to https://www.mellanox.com/page/mlnx_onyx.
For ONIE1: Please refer to ONIE User Manual. You can find the user manual at https://www.mellanox.com → Products → Ethernet Switch Systems → SN2000 Series.
For Cumulus2: The MGMT port will acquire the IP from DHCP by default. You can cross reference the MAC of the switch with your DHCP server (MAC can be found on switch label) or using "ifconfig eth0" (when using MGMT0). For further information refer to: https://docs.cumulusnetworks.com/display/DOCS/Quick+Start+Guide.
For full installation instructions, go to https://docs.nvidia.com/networking/category/switchen.