SN3800 DC Ethernet Switch Systems Quick Installation Guide
SN3800 DC Ethernet Switch Systems Quick Installation Guide

Installation and Configuration

#

Illustration

1

Attach parts D and E (x2 of each) to the switch. Push the switch chassis’ pins through the slider key holes, until locking occurs. Pay attention to the rack’s type.

Short Racks (430-580mm):

image2022-3-9_15-35-11.png

Standard Racks (580-800mm):

image2022-3-9_15-34-11.png

2

Short Racks:

image2022-3-9_15-36-57.png

Standard Racks:

image2022-3-9_15-36-18.png

3

Install 8 cage nuts (B) in the desired 2U slots in the rack.

image2022-3-2_15-19-55.png

4

Do not tighten the screws yet.

image2022-3-2_15-21-38.png

5

image2022-3-9_15-38-32.png

6

Tighten all 8 M6 (C) screws with a torque of 4.5±0.5 Nm.

image2022-3-9_15-39-23.png

Connector (Front) Side

image2022-3-9_15-44-25.png

FRU (Rear) Side

image2022-3-9_15-45-54.png

* It may take up to five minutes to turn on the system. If the System Status LED shows amber after five minutes, unplug the system and contact your NVIDIA representative.

** Certain systems have a single management port.

LED Assignments

Symbol

Description

Normal Status

image2022-2-28_13-58-49.png

System health

Green/Flashing

image2022-2-28_13-59-22.png

Fan health

Green

image2022-2-28_14-0-26.png

Power supply health

Green

image2022-2-28_14-1-2.png

Bad port detected

Off

image2022-2-28_14-3-4.png

Identifier LED

Off/Blue

image2022-2-28_14-3-22.png

Reset button

Before installing the switch system, make sure an over-current DC circuit breaker of up to 100A is installed at the rack.

Connect the DC power supplies in the switch according to the following recommendations:

  1. Make sure circuit breakers are in their “Off” state.

  2. Ground the PSU with a 14 AWG wire.

  3. Using an 8 AWG wire for the power feed, unscrew the screws on the DC PSU terminals, connect the DC power cord lugs, and tighten the screws.

  4. Repeat all steps for secondary PSU.

  5. Turn on the switch by switching the circuit breaker to the “On” position for both PSUs.

  1. Connect the host PC to the Console (RJ-45) port.

  2. Configure a serial terminal program.

    Parameter

    Settings

    Baud rate

    115200

    Data bits

    8

    Stop bits

    1

    Parity

    None

    Flow control

    None

  3. Login:

    OS

    Username

    Password

    Onyx (MLNX-OS)

    admin

    admin

    Cumulus Linux

    cumulus

    CumulusLinux! (case sensitive)

    a. No login is required. Press Enter to activate the console.

  4. Initial configuratio

For full installation instructions, go to https://docs.nvidia.com/networking/category/switchen.

© Copyright 2023, NVIDIA. Last updated on May 22, 2023.