Multi-Node Deployment

View as MarkdownOpen in Claude

Multi-node deployment distributes a model across physical nodes when a single node lacks sufficient GPU capacity.

NIM LLM and VLM uses Ray to form a cluster and vLLM to distribute inference across it.

Multi-node deployment splits model weights across nodes using two parallelism strategies:

  • Pipeline Parallelism (PP) splits a model into stages. For example, PP=2 can place one stage on each of two nodes.
  • Tensor Parallelism (TP) splits model layers across the GPUs in each stage. For example, TP=8 uses eight GPUs per stage.

The most common configuration sets the tensor-parallel size to the number of GPUs per node and the pipeline-parallel size to the number of nodes.

A topology with two nodes and eight GPUs each can use these settings:

  • TP = 8 (8 GPUs per node)
  • PP = 2 (2 nodes)
  • Total GPUs = 16

In some cases, multi-node tensor parallelism is used instead, where a single tensor-parallel group spans multiple physical nodes:

  • TP = 16
  • PP = 1
  • Node A: 8 GPUs, Node B: 8 GPUs
  • One TP group spans 2 nodes with 16 GPUs total

Multi-node TP requires continuous cross-node GPU communication. Performance depends on network bandwidth, latency, and Remote Direct Memory Access (RDMA) availability.

Known Limitations

Multi-node Ray workers cannot use the NIM JSON log formatter.

Disable structured (JSON) logging for multi-node deployments. Set model.jsonLogging=false in Helm values. The NIM JSON log formatter is not available in the backend’s Ray worker processes and causes worker initialization to fail.

Architecture

NIM multi-node deployments run the same container image in leader and worker pods. The leader starts a Ray head node, downloads the model, and launches vLLM with the Ray distributed executor. Worker pods join the Ray cluster and provide GPU resources for model execution.

The following diagram shows this architecture:

Leader Node Worker Node 1 Worker Node N Ray cluster Ray cluster NCCL NCCL Ray Head Inference Server(vLLM) Ray Worker GPUs Ray Worker GPUs

Prerequisites

Before you deploy NIM in multi-node mode, complete the following prerequisites:

  1. Provision a Kubernetes cluster with GPU nodes, where each node has the same number and type of GPUs.

  2. Install the LeaderWorkerSet CRD on the cluster. LeaderWorkerSet is a Kubernetes-native mechanism for managing leader/worker pod groups:

    kubectl apply --server-side -f https://github.com/kubernetes-sigs/lws/releases/latest/download/manifests.yaml
  3. Provide shared storage (recommended): a PVC with ReadWriteMany access mode or an NFS mount, so the leader downloads the model once and shares it with workers.

  4. Provide high-speed networking (recommended): InfiniBand or RDMA over Converged Ethernet (RoCE) for optimal NCCL performance in multi-node configurations.

  5. Confirm sufficient GPU resources across all nodes to satisfy the TP × PP requirement.

  6. Fetch and extract the chart by following Fetch the Helm Chart.

  7. Create the ngc-secret registry secret and the nvidia-nim-secrets API key secret by following Create NGC Credentials. Use the namespace where you will install the chart.

  8. For a gated Hugging Face checkpoint, accept its access terms, export HF_TOKEN, and create the source credential in the same namespace:

    kubectl create secret generic hf-token --from-literal=HF_TOKEN="$HF_TOKEN"

Deploy with Helm

The NIM LLM and VLM Helm chart natively supports multi-node deployments using LeaderWorkerSet. Use the following sections to install a minimal chart, review the multi-node Helm values, and choose a model profile.

Minimal Configuration

To deploy a minimal multi-node Helm example, complete the following steps:

  1. Create values.yaml with the topology below. Set model.modelPath to a compatible checkpoint for your GPU configuration and set the shared storage class and size for the model’s cache. If the checkpoint requires a Hugging Face token, set model.hfTokenSecret: hf-token.

    image:
    repository: "nvcr.io/nim/nvidia/model-free-nim-pb7"
    tag: "2.1.5-pb7.0"
    model:
    modelPath: "<compatible-model-uri>"
    ngcAPISecret: nvidia-nim-secrets
    jsonLogging: false
    imagePullSecrets:
    - name: ngc-secret
    multiNode:
    enabled: true
    workers: 1 # Number of worker pods (total nodes = workers + 1 leader)
    tensorParallelSize: 8 # GPUs per tensor-parallel group
    pipelineParallelSize: 2 # Number of pipeline stages (typically = number of nodes)
    resources:
    limits:
    nvidia.com/gpu: 8
    requests:
    nvidia.com/gpu: 8
    persistence:
    enabled: true
    size: "<cache-size>"
    accessMode: ReadWriteMany # Required for multi-node with shared storage
    storageClass: <your-rwx-storage-class>
  2. Install the chart:

    helm install nim-llm nim-llm/ -f values.yaml

Helm Values Reference

Use the following Helm values to configure multi-node deployment behavior, model profile selection, and Ray communication settings.

ParameterDescriptionDefault
multiNode.enabledEnable multi-node deployment modefalse
multiNode.workersNumber of worker pods per replica1
multiNode.tensorParallelSizeNumber of GPUs per tensor-parallel group (sets NIM_TENSOR_PARALLEL_SIZE). Set to 0 to omit.0
multiNode.pipelineParallelSizeNumber of pipeline stages across nodes (sets NIM_PIPELINE_PARALLEL_SIZE). Set to 0 to omit.0
multiNode.expertParallelSizeExpert-parallel group size for MoE models (sets NIM_EXPERT_PARALLEL_SIZE). NIM system-config validation enforces ep == tp*dp. Set to 0 to omit.0
multiNode.dataParallelSizeData-parallel replicas (sets NIM_DATA_PARALLEL_SIZE). Set to 0 to omit.0
multiNode.ray.portRay head node communication port6379
model.profileExplicit profile name or hash (alternative to TP/PP values). Sets NIM_MODEL_PROFILE.""
model.hfTokenSecretKubernetes secret name containing HF_TOKEN for Hugging Face model downloads.""

Profile Selection

You must specify how the model profile is selected. Choose one of these approaches:

Multi-node deployment requires either tensorParallelSize/pipelineParallelSize (both >0) or model.profile to be set. The Helm chart will fail to render if neither is provided.

Configure Model Storage

The leader and all worker nodes must have access to the model weights at the same filesystem path. There are two supported approaches:

Use a PVC with ReadWriteMany access mode or NFS. With shared storage:

  • The leader downloads the model once to the shared volume.
  • Workers detect the cached model blobs in shared storage and materialize a local workspace at /tmp/nim_workspace without a network download.

The Helm chart supports two shared storage backends:

  • PVC with existingClaim: Pre-create a ReadWriteMany PVC. The PVC survives helm uninstall, so the model cache persists across deployments and subsequent installs skip the download.
  • NFS direct mount: Set nfs.enabled=true with nfs.server and nfs.path. Same persistence behavior as PVC.

The following example shows a PVC-based configuration:

persistence:
enabled: true
size: 200Gi
accessMode: ReadWriteMany
storageClass: <your-rwx-storage-class>

If persistence is enabled, accessMode must be ReadWriteMany. A ReadWriteOnce PVC cannot be mounted on multiple nodes.

Independent Downloads

If shared storage is not available, each node downloads the model independently to local storage (emptyDir). This works but is not recommended because it wastes time and network bandwidth.

Model-free NIM deployments (using model.modelPath) support both shared and independent storage. However, shared storage is strongly recommended for multi-node deployments.

Deploy with the NIM Operator

The NIM Operator provides a fully automated deployment experience for multi-node NIM. The operator manages the NIMService custom resource and automatically:

  • Generates leader and worker pod specifications
  • Injects the appropriate Ray startup commands
  • Handles PVC setup through NIMCache
  • Manages probes, networking, and secrets

Refer to the NIM Operator Deployment documentation for full details on deploying with the NIM Operator.

Review Multi-Node Examples

Use the following examples to configure common multi-node deployments with different tensor and pipeline parallelism settings.

Multi-Node Tensor Parallelism (TP=16, PP=1)

Two nodes, each with eight GPUs. A single TP group spans both nodes. Apply these overrides to the minimal configuration for a model and hardware that support this topology.

multiNode:
enabled: true
workers: 1
tensorParallelSize: 16
pipelineParallelSize: 1

Multi-node TP requires high-bandwidth, low-latency interconnect (for example, InfiniBand with RDMA) for acceptable performance.

Model-Free Multi-Node Deployment

This example uses Llama 3.1 405B from Hugging Face to show the Model-Free configuration for two nodes with eight GPUs per node. Before installing with Helm, confirm your checkpoint fits the selected GPUs and set a shared storage class and capacity.

image:
repository: "nvcr.io/nim/nvidia/model-free-nim-pb7"
tag: "2.1.5-pb7.0"
model:
modelPath: "hf://meta-llama/Llama-3.1-405B-Instruct"
ngcAPISecret: nvidia-nim-secrets
hfTokenSecret: hf-token
jsonLogging: false
multiNode:
enabled: true
workers: 1
tensorParallelSize: 8
pipelineParallelSize: 2
resources:
limits:
nvidia.com/gpu: 8
requests:
nvidia.com/gpu: 8
persistence:
enabled: true
size: 1Ti
accessMode: ReadWriteMany
storageClass: "<your-rwx-storage-class>"
imagePullSecrets:
- name: ngc-secret

Troubleshoot Multi-Node Deployments

Use the following checks when leader or worker pods fail to form a Ray cluster, download a model, or schedule GPUs.

Workers Cannot Join the Ray Cluster

Use the following checks if workers cannot join the Ray cluster:

  • Verify that the Ray port (default 6379) is accessible between pods. Check network policies.

  • Ensure that LWS_LEADER_ADDRESS is being injected correctly by the LeaderWorkerSet controller.

  • Check worker logs for Ray connection errors:

    kubectl logs "your-worker-pod-name"

Model Download Failures

Use the following checks if model downloads fail:

  • Confirm that NGC_API_KEY is set correctly in the referenced secret.
  • If using shared storage, verify the PVC is bound and has ReadWriteMany access mode.
  • Check that the storage class supports the required access mode.

NCCL Communication Errors

Use the following checks if NCCL communication errors occur:

  • For multi-node TP, ensure high-speed interconnect (InfiniBand/RoCE) is available and configured.

  • Verify that NCCL environment variables are set appropriately for your network topology. You can pass these via env in values.yaml:

    env:
    - name: NCCL_IB_DISABLE
    value: "0"
    - name: NCCL_DEBUG
    value: "INFO"

Pod Scheduling Issues

Use the following checks if pods cannot be scheduled:

  • Verify that each node has the required GPU resources available.
  • Check that nodeSelector, affinity, or tolerations are configured correctly for GPU nodes.
  • Confirm that nvidia.com/gpu resource requests match the available GPUs per node.

Next Steps

Continue with operator-managed multi-node, profile selection, or single-node Helm: