NIM Service Chart
Overview
The nvidia-active-speaker-detection-h4m-service Helm chart deploys the Active Speaker Detection NIM as a standalone inference service on Kubernetes or Red Hat OpenShift.
- Inputs: Video stream and one or more diarized audio streams via SMPTE ST 2110
- Outputs: Bounding box metadata via SMPTE ST 2110-40 ancillary data; optionally video with bounding box overlay.
This chart can be deployed standalone for integration into a custom media pipeline, or as a subchart of the end-to-end demo chart.
Installation
Prerequisites
Complete all prerequisite steps (Rivermax license, image pull and model pull secrets, high-speed network attachment) before running helm install. For details, refer to Getting Started. For hardware requirements per pod, refer to the Support Matrix.
Pull the Chart
If not already done, add the Helm repository and pull the chart. For the full repository setup, refer to Pull Helm Charts.
The downloaded .tgz is referenced directly in the following installation commands.
Helm Installation
The chart includes a default values.yaml. For full SMPTE ST 2110 and NMOS override files, refer to Starter Configuration Files.
The default values.yaml ships with example values for cluster-specific fields such as node selector (example-gpu-node), image pull secret, network name, and scheduler. You must update these values to match your cluster before deploying.
Default deployment (SMPTE ST 2110 NMOS mode, 1080p):
With node hostname and secret overrides:
After installation, check the status:
On Red Hat OpenShift, replace kubectl with oc.
Deployment Modes
The NIM service offers two modes to support media stream connections:
SMPTE ST 2110 Mode
NMOS discovery is disabled. All multicast IP addresses, ports, and session parameters must be configured explicitly. Sender output IP addresses and ports must match NIM service input IP addresses and ports, and NIM service output IP addresses and ports must match downstream receiver input IP addresses and ports.
NMOS Mode
Stream connections are managed via the NMOS Connection Manager UI. Most input and output transport parameters can be omitted from the values file—only session names and ancillary output parameters must be set. On Holoscan for Media clusters, the UI is typically opened from a browser on the cluster network; for remote graphical access, refer to Chrome Remote Desktop in Getting Started.
In NMOS mode, connect receivers to the NIM service before connecting the sender via the NMOS Connection Manager UI. This procedure prevents frames from accumulating in receiver queues.
Starter Configuration Files
Copy the appropriate configuration below into values-st2110.yaml or values-nmos.yaml, adjust the fields for your environment, and pass it to helm upgrade --install with -f.
For a full reference of all available Helm keys, pipeline tuning parameters, and environment variables, refer to the Configuration Reference.
ST2110 Configuration — Static (values-st2110.yaml)
NMOS Configuration (values-nmos.yaml)
In NMOS mode, connect receivers to the NIM service before connecting the sender via the NMOS Connection Manager UI.
Verify
Verify configured Helm values:
On Red Hat OpenShift, replace kubectl with oc. For log access, refer to Observability.
Uninstall