Bug Fixes in this Firmware Version

For a list of old Bug Fixes, please see Bug Fixes History.

Internal Ref.

Issue

3134894

Description: Fixed an issue where set_flow_table_entry failed when aso_flow_meter action was used.

Keywords: ASO Flow Meter, FW Steering

Discovered in Version: 16.30.1004

Fixed in Release: 16.34.1002

3059379

Description: Added "Command Unsupported" response code in cases when running the MCTP control command "Get Vendor Defined Messages Supported", and there were no supported VDMs.

Keywords: MCTP control command

Discovered in Version: 16.30.1004

Fixed in Release: 16.34.1002

2994292

Description: Fixed a race condition occured between the duplicate read and QP commands (2RST, 2ERR and Destroy) in the signature that caused the command to hang.

Keywords: Race condition

Discovered in Version: 16.30.1004

Fixed in Release: 16.34.1002

3059082

Description: When all traffic applications sharing the same combination of <function, priority, side> are rate limited (for example by congestion control), this limit is enforced on other applications with different combinations of <function, priority, side> under the same VL. For example, requestor flows (RDMA-write) are limited to rate X, however, this rate is also enforced on a QP sending RDMA-read responses.

This firmware version prevents rate limit enforcement on traffic applications which should not be limited.

Keywords: Rate limit enforcement

Discovered in Version: 16.32.1010

Fixed in Release: 16.34.1002