Known Issues

Ethernet Rate Limit per VF in RoCE Mode Limitations

Dual Port Device

Single Port Device

w/o LAG (TOTAL_VFS>32)

With LAG (TOTAL_VFS<32)

w/o LAG

w/o QoS

Full QoS

w/o QoS

Full QoS

w/o QoS

Full QoS

127

45

32

20

127

100

Ethernet Rate Limit per VF in InfiniBand Mode Limitations

Dual Port Device

Single Port Device

w/o LAG

w/o LAG

w/o QoS

Full QoS

w/o QoS

Full QoS

127

26

127

55

Known Issues

Internal Ref.

Issue

2866931

Description: When the host powers up directly into the standby mode, the adapter may not handle WOL packets.

Workaround: N/A

Keywords: WOL packets

Discovered in Version: 26.32.1010

2864238

Description: VPD cannot be accessed after firmware upgrade or reset when the following sequence is performed:

  1. Upgrade to a new firmware and perform a cold reboot

  2. Downgrade to an old firmware

  3. Run fwreset

  4. Upgrade to a new firmware

  5. Run fwreset

Workaround: Run the upgrade or reset sequence as follow:

  1. Upgrade to a new firmware and perform a cold reboot

  2. Downgrade to an old firmware

  3. Run fwreset

  4. Upgrade to a new firmware

  5. Perform a cold reboot

Keywords: VDP

Discovered in Version: 26.32.1010

2780349

Description: As a result of having a single LED per port, features such as the Blinking Detection can work only when in low speed mode.

Workaround: N/A

Keywords: LED, port, Blinking Detection

Discovered in Version: 26.32.1010

2834990

Description: On rare occasions, when toggling both sides of the link, the link may not rise.

Workaround: Toggle the port to free it.

Keywords: Port toggling, link

Discovered in Version: 26.31.1014

2667681

Description: As the Connection Tracking (CT) is not moved to SW state after receiving a TCP RST packet, any packet that matches the windows even after the RST is marked as a valid packets.

Workaround: N/A

Keywords: Connection Tracking

Discovered in Version: 26.31.1014

2378593

Description: Sub 1sec firmware update (fast reset flow) is not supported when updating from previous releases to the current one. Doing so may cause network disconnection events.

Workaround: Use full reset flow for firmware upgrade/downgrade.

Keywords: Sub 1sec firmware update

Discovered in Version: 26.29.1016

2213356

Description: The following are the Steering Dump limitations:

  • Supported only on ConnectX-5 adapter cards

  • Requires passing the version (FW/Stelib/MFT) and device type to stelib

  • Re-format is not supported

  • Advanced multi-port feature is not supported – LAG/ROCE_AFFILIATION/MPFS_LB/ESW_LB (only traffic vhca <-> wire)

  • Packet types supported:

    • Layer 2 Eth

    • Layer 3 IPv4/Ipv6/Grh

    • Layer 4 TCP/UDP/Bth/GreV0/GreV1

    • Tunneling VXLAN/Geneve/GREv0/Mpls

  • FlexParser protocols are not supported (e.g AliVxlan/VxlanGpe etc..).

  • Compiles only on x86

Workaround: N/A

Keywords: Steering Bump

Discovered in Version: 26.29.1016

2365322

Description: When configuring adapter card's Level Scheduling, a QoS tree leaf (QUEUE_GROUP) configured with default rate_limit and default bw_share, may not obey the QoS restrictions imposed by any of the leaf’s ancestors.

Workaround: To prevent such a case, configure at least one of the following QoS attributes of a leaf: max_average_bw or bw_share

Keywords: QoS

Discovered in Version: 26.29.1016

2201468

Description: Running multiple resets ("mlxfwreset --sync=1") simultaneously is not functioning properly,

Workaround: Wait a few seconds until you run "mlxfwreset --sync=0".

Keywords: mlxfwreset, reset-sync, reset, sync

Discovered in Version: 26.28.1002

© Copyright 2023, NVIDIA. Last updated on May 23, 2023.