Known Issues

ConnectX-7 has the same feature set and limitations as ConnectX-6 adapter card. For the list of ConnectX-6 Known Issues, please go to https://docs.nvidia.com/networking/category/connectx6fw.

The below are limitations related to ConnectX-7 only.

Internal Ref.

Issue

2993483

Description: Optical cables are not supported in this version of the ConnectX-7 (both ETH and IB) firmware.

Workaround: N/A

Keywords: Optical cables

Discovered in Version: 28.33.2028

2993531

Description: PML1 is disabled by default. Enabling it might result in server hanging.

Workaround: N/A

Keywords: PML1

Discovered in Version: 28.33.2028

2824427

Description: Running with a debug firmware reduces security as if token was applied.

Workaround: N/A

Keywords: Debug Firmware

Discovered in Version: 28.33.2028

3046168

Description: Congestion Control is not enabled when one link type of different ports is different.

Workaround: N/A

Keywords: Congestion Control, Link Type, PCC

Discovered in Version: 28.33.2028

3047723

Description: When changing the protocols from ETH to IB on two ConnectX-7 adapter cards connected to each other, the ports on both sides must be toggled to get the link up.

Workaround: N/A

Keywords: Linkup, port toggling, protocol change

Discovered in Version: 28.33.2028

3033874

Description: Connecting a ConnectX-7 adapter card to either a ConnectX-5 adapter card or to an NVIDIA Spectrum switch system is supported only when using a 100GbE optic cables and when configuring ConnectX-5 or the NVIDIA Spectrum switch system to Force Mode.

Workaround: N/A

Keywords: Linkup connectivity

Discovered in Version: 28.33.2028

3039348

Description: Host Chaining is currently not supported in ConnectX-7 adapter cards.

Workaround: N/A

Keywords: Host Chaining

Discovered in Version: 28.33.2028

3023751

Description: Link flapping may occur when using ConnectX-7 adapter cards with HDR optic cables.

Workaround: N/A

Keywords: Link flapping, HDR optic cables

Discovered in Version: 28.33.2028

2920813

Description: The an_disable flow is not supported in ConnectX-7 adapter cards for 25GbE and 50G_2x link speeds when using one of the following cables:

  • MT1841VS00827 (rev A4)

  • MT1830VS00895 (rev A3)

The flow is supported only when configuring FEC using the PPLM register.

Workaround: N/A

Keywords: AN, cables, 25GbE, FEC

Discovered in Version: 28.33.2028

2947588

Description: Trying to query/burn the firmware using the flint utility when the image is pending (after firmware burn and before firmware reset), results in the action's failure.

Workaround: Perform a firmware reset after each firmware burn.

Keywords: flint, query/burn firmware

Discovered in Version: 28.33.2028

3024199

Description: When connecting a ConnectX-7 adapter card to an NVIDIA Quantum switch using the copper cable (MCP1600-E01AE30), the link is Down when in EDR speed.

Workaround: N/A

Keywords: EDR, copper cable, NVIDIA Quantum

Discovered in Version: 28.33.2028

-

Description: Upgrading to firmware 28.33.2028 from any previous Engineering Sample (earlier than version 28.98.2406) must be done before installing WinOF-2 v2.90 driver and requires going through the following steps:

  1. Upgrade to 28.98.2406 version while the driver is enabled.

  2. Upgrade to firmware version 28.33.2028 (the driver can be enable at this stage).

Workaround: N/A

Keywords: Firmware upgrade

Discovered in Version: 28.33.2028

-

Description: Downgrading from firmware 28.33.2028 to any previous Engineering Sample firmware is not supported.

Workaround: N/A

Keywords: Firmware downgrade

Discovered in Version: 28.33.2028

2969829

Description: On rare occasions, the HDR speed link up time when using the optical module MFA7U10-H010 might take up to 70sec.

Workaround: N/A

Keywords: HDR, link up time, optical cable

Discovered in Version: 28.33.2028