Problem Indicator | Symptoms | Cause and Solution |
---|---|---|
LEDs | System Status LED is blinking for more than 5 minutes | Cause: MLNX-OS software did not boot properly and only firmware is running. Solution: Connect to the system via the console port, and check the software status. You might need to contact an FAE if the MLNX-OS software did not load properly. |
System Status LED is amber | Cause:
Solution:
| |
Fan Status LED is amber | Cause: Possible fan issue Solution:
| |
Front PSU Status LED is amber | Cause: Possible PSU issue
| |
The activity LED does not light up (InfiniBand) | Make sure that there is an SM running in the fabric. | |
System boot failure | The last software upgrade failed on x86 based systems | Solution:
Default image: 'SX_X86_64 SX_3.4.0008 2014-11-10 20:07:51 x86_64' Press enter to boot this image, or any other key for boot menu Booting default image in 3 seconds. Boot Menu ------------------------------------------------------------------- 0: SX_X86_64 SX_3.4.0008 2014-11-10 20:07:51 x86_64 1: SX_X86_64 SX_3.4.0007 2014-10-23 17:27:34 x86_64 ------------------------------------------------------------------- Use the ArrowUp and ArrowDown keys to select which entry is highlighted. Press enter to boot the selected image or 'p' to enter a password to unlock the next set of features. Highlighted entry is 0: "
|