Appendix – Device Management Feature Support
The following table describes the management features available on supported devices.
Feature  | 10 Gb Ethernet Gateway Module  | Grid Director 4700/ 4200/ 4036/ 4036E v3.5  | Managed IS5000 Switchesv  | Managed SX6000 Switches  | Externally Managed IS5000 / SX6000 Switches  | Gateway BX5020  | HP C-Class  | Linux Hosts  | Windows Hosts  | 
Discovery  | |||||||||
IB L2 Discovery  | Yes  | Yes  | Yes  | Yes  | Yes  | Yes  | Yes  | Yes  | Yes  | 
Advanced Discovery (IP, hostname, Hosts: CPU, memory, FW version)  | Yes  | Yes  | No  | Yes  | No  | No  | No  | Yes with UFM Host Agent  | No  | 
Ethernet access Management interface  | Yes  | Yes  | Yes  | Yes  | No  | No  | No  | Yes  | Yes  | 
Provisioning/ Configuration  | |||||||||
IB Partitioning (pkey)  | Yes  | Yes  | Yes  | Yes  | Yes  | Yes  | Yes  | Yes  | Yes  | 
QoS: SL (SM configuration)  | N/A  | Yes  | Yes  | Yes  | Yes  | Yes  | Yes  | Yes  | Yes  | 
QoS: Rate Limit (SM configuration)  | N/A  | Yes  | Yes  | Yes  | Yes  | Yes  | Yes  | Yes  | Yes  | 
Interface/VIF Configuration (IP, hostname, mtu, Bonding)  | N/A  | N/A  | N/A  | N/A  | N/A  | No  | N/A  | Yes with UFM Host Agent  | No  | 
Device Monitoring  | |||||||||
Device Resources: CPU, Memory, Disk  | No  | Yes  | No  | No  | No  | No  | No  | Yes with UFM Host Agent  | No  | 
Get device alerts (Temperature, PS, Fan) Note: This feature is not supported on Switch-X switches.  | Yes  | Yes  | No  | Yes  | Yes  | No  | No  | No  | No  | 
L1 (Physical Port) –Monitoring  | Yes  | Yes  | Yes  | Yes  | Yes  | Yes  | Yes  | Yes  | Yes  | 
L2-3 (Interface/VIF) –Monitoring  | No  | No  | No  | No  | No  | No  | No  | Yes with UFM Host Agent  | No  | 
Congestion Monitoring per port (enables congestion map)  | No  | Yes  | Yes  | Yes  | Yes  | Yes  | Yes  | Yes  | Yes  | 
Congestion Monitoring per flow (Advanced Package)  | No  | Yes  | No  | No  | No  | No  | No  | No  | No  | 
Device Management  | |||||||||
Add/remove to/from Rack  | Yes  | Yes  | Yes  | Yes  | Yes  | Yes  | Yes  | Yes  | Yes  | 
Add/remove to/from Logical Server  | N/A  | N/A  | N/A  | N/A  | N/A  | N/A  | N/A  | Yes  | Yes  | 
View/clear Alarms  | Yes  | Yes  | Yes  | Yes  | Yes  | Yes  | Yes  | Yes  | Yes  | 
SSH terminal to device  | Yes  | Yes  | Yes  | Yes  | No  | No  | No  | Yes  | Yes  | 
Power On  | No  | No  | No  | No  | No  | No  | No  | Yes with IPMI  | No  | 
Reboot  | No  | No  | No  | Yes (SX3606 only)  | No  | No  | No  | Yes with IPMI  | No  | 
Shutdown  | No  | No  | No  | No  | No  | No  | No  | Yes with IPMI  | No  | 
Port Enable/Disable  | No  | Yes  | Yes  | Yes  | Yes  | Yes  | Yes  | Yes  | Yes  | 
Firmware Upgrade (HCA & switch)  | No  | Yes  | No  | Yes (Upon SW upgrade – SX6036 only)  | No  | No  | No  | Yes  | No  | 
Inband Firmware Upgrade (over InfiniBand connection)  | No  | No  | No  | No  | Yes  | No  | No  | Yes  | Yes  | 
Software Upgrade (OFED & switch)  | No  | Yes  | No  | Yes (SX3606 only)  | No  | No  | No  | Yes with UFM Host Agent  | No  | 
Protocols  | |||||||||
Communication UFM Server – Device  | IB/SNMP  | IB/UDP /SSH  | IB  | IB/HTTP/ SSH  | IB  | IB  | IB  | IB, SSH, IPMI, UDP  | IB  | 
QoS Rate Limit (SM configuration): On ConnectX HCAs-only, for hosts.
XmitWait counter monitoring requires ConnectX HCAs with firmware version 2.6 and above.
This feature requires that the IP address is configured.