NVIDIA BlueField-2 DPU Firmware Release Notes v24.39.2048
NVIDIA BlueField-2 DPU Firmware Release Notes v24.39.2048

Bug Fixes History

For bug fixes prior to version 24.33.1048, please refer to the NVIDIA BlueField-2 DPU documentation.

Internal Ref.

Issue

3365411

Description: Fixed a link failure that occurred due to a wrong 'is_inphi_cable' indication.

Keywords: Link failure

Discovered in Version: 24.37.1300

Fixed in Release: 24.38.1002

3435583

Description: Under certain configurations, during the loading of the PXE driver in Smart-NIC mode, the firmware attempts to lock the CMAS resources in ICMC sets that are full. This results in the failure of the locking and raises a health buffer indication.

To prevent the above scenario, in this firmware version we improved the distribution of resource locking in ICMC.

Keywords: ICMC locking

Discovered in Version: 24.37.1300

Fixed in Release: 24.38.1002

3331179

Description: Improved token calculation.

Keywords: Token calculation

Discovered in Version: 24.37.1300

Fixed in Release: 24.38.1002

3491841

Description: Fixed a firmware assert that occurred when tried to verify if the module supported "swap".

Keywords: Firmware assert

Discovered in Version: 24.37.1300

Fixed in Release: 24.38.1002

Internal Ref.

Issue

3432548

Description: Closed the attached QP doorbell to avoid any impact from the software side or the db_recovery mechanism

Keywords: QP doorbell

Discovered in Version: 24.35.2000

Fixed in Release: 24.37.1300

3385129

Description: Fixed an issue that resulted in high PTP offset by changing the RST value to 200, and adjusting the PTP Tx offset in PTP4L configuration.

Keywords: PTP glitch, PTP constant offset

Discovered in Version: 24.35.2000

Fixed in Release: 24.37.1300

3233113

Description: Disabled some HW optimization to prevent a HW race that caused an SQ to get stuck.

Keywords: HW race, SQ

Discovered in Version: 24.33.1048

Fixed in Release: 24.37.1300

3306318

Description: Fixed the issue that caused the virtio PXE boot to fail due to virtio BLK controller being stuck in continuous host warm reboot.

Keywords: virtio full emulation, PXE boot, warm reboot

Discovered in Version: 24.35.2000

Fixed in Release: 24.37.1300

3327847

Description: CNP received, handled, and ignored counters in the hardware counters cannot work after moving to Programmable Congestion Control mode.

Keywords: CNP, Programmable Congestion Control

Discovered in Version: 24.35.2000

Fixed in Release: 24.37.1300

Internal Ref.

Issue

3217896

Description: Fixed RDE PATCH operation status code reported in case the property is "read-only".

Keywords: RDE

Discovered in Version: 24.35.1012

Fixed in Release: 24.35.2000

3241357

Description: Fixed an issue in MCTP-over-PCIe, where the VDM message with the type Route-to-Root Complex, the target ID was not set as 0x0.

Keywords: MCTP-over-PCIe, VDM message

Discovered in Version: 24.35.1012

Fixed in Release: 24.35.2000

3250924

Description: Fixed an issue that resulted in NVMe driver not loading on a hotplug-able device when VIRTIO_EMULATION_HOTPLUG_TRANS was enabled by mlxconfig.

Keywords: VIRTIO_EMULATION_HOTPLUG_TRANS, NVMe

Discovered in Version: 24.35.1012

Fixed in Release: 24.35.2000

3215393

Description: Fixed an issue that caused the virtual QoS mechanism to stop traffic from reaching the full line rate of 200GbE on each direction when LAG was enabled.

Keywords: Virtual QoS mechanism, 200GbE, LAG

Discovered in Version: 24.35.1012

Fixed in Release: 24.35.2000

© Copyright 2023, NVIDIA. Last updated on Dec 12, 2023.