| Internal Ref. | Issue |
| 4219027 | Description: Fixed an issue where the BlueField-3 device, which uses two GPIOs for pkg_id calculation, had the MSB incorrectly set to zero. |
| Keywords: NC-SI package ID | |
| Discovered in Version: 32.42.1000 | |
| Fixed in Release: 32.43.2402 | |
| 4174096 | Description: Fixed an issue that occasionally resulted in ext_synd = 0x8309 in dmesg when enabled the internal NP/DOCA NP. |
| Keywords: PCC NP | |
| Discovered in Version: 32.42.1000 | |
| Fixed in Release: 32.43.2402 | |
| 4030180 | Description: Fixed an issue that prevented virtio 2K device from working with LFWP at the same time due to limited hardware resource. Therefore, resulting in LFWP command failure. |
| Keywords: virtio 2K, LFWP | |
| Discovered in Version: 32.42.1000 | |
| Fixed in Release: 32.43.2402 | |
| 3787618 | Description: NVIA register is not allowed for external host if any field of EXTERNAL_HOST_PRIV or EXTERNAL_HOST_PRIV_FAST TLVs is not set as the default. |
| Keywords: Host privilege | |
| Discovered in Version: 32.41.1000 | |
| Fixed in Release: 32.43.2402 | |
| 3614288 | Description: Occasionally, the device may hang when there a hot plug is performed from a unknown direction. |
| Keywords: Hot-plug operation | |
| Discovered in Version: 32.39.2028 | |
| Fixed in Release: 32.43.2402 |