NVIDIA BlueField BMC Software v23.10
1.0

FRU Reading

FRU data is embedded within the chassis schema. To retrieve the relevant FRU data, execute the following Redfish command:

Copy
Copied!
            

curl -k -u root:'<password>' -H 'Content-Type: application/json' -X GET https://<bmc_ip>/redfish/v1/Chassis/Card1/

The FRU data can be found in the following read attributes:

Copy
Copied!
            

{ "Manufacturer": "Nvidia", "Model": "Bluefield 3 SmartNIC Main Card", "PartNumber": "900-9D3B4-00EN-EAB ", "SerialNumber": "MT2245X00175 ", }

To retrieve FRU info, run:

Copy
Copied!
            

ipmitool -C 17 -I lanplus -H <bmc_ip> -U ADMIN -P ADMIN fru print <fru_id>

FRU ID of the BMC FRU EEPROM is optional and can be found using the fru print command.

It is possible to dump the binary FRU data into a file. Run:

Copy
Copied!
            

ipmitool -C 17 -I lanplus -H <bmc_ip> -U ADMIN -P ADMIN fru read <fru_id> <filename>

Warning

The parameter <filename> is the absolute path to the file.