Release Notes Change Log History
BlueField-3 tuning update for power and performance
BlueField-3 power-capping and thermal-throttling
Added Linux fsck to boot flow
Log PCIe errors (to RShim log)
Halt uncorrectable double-bit ECC error on DDR
Added support for live migration of VirtIO-net and VirtIO-blk VFs from one VM to another. Requires working with the new vDPA driver.
OS configuration – enabled tmpfs in /tmp
Added support for Arm host
Enroll new NVIDIA certificates to DPU UEFI database
ImportantImportant: User action required! See known issue #3077361 for details.
This is the last release to offer GA support for first-generation NVIDIA® BlueField® DPUs.
Added support for NIC mode of operation
Added password protection to change boot parameters in GRUB menu
Added IB support for DOCA runtime and dev environment
Implemented RShim PF interrupts
Virtio-net-controller is split to 2 processes for fast recovery after service restart
Added support for live virtio-net controller upgrade instead of performing a full restart
Expanded BlueField-2 PCIe bus number range to 254 (0-253)
Added a new CAP field, log_max_queue_depth (value can be set to 2K/4K), to indicate the maximal NVMe SQ and CQ sizes supported by firmware. This can be used by NVMe controllers or by non-NVMe drivers which do not rely on NVMe CAP field.
Added ability for the RShim driver to still work when the host is in secure boot mode
Added bfb-info command which provides the breakdown of the software components bundled in the BFB package
Added support for rate limiting VF groups
PXE boot option is enabled automatically and is available for the ConnectX and OOB network interfaces
Added Vendor Class option "BF2Client" in DHCP request for PXE boot to identify card
Updated the "force PXE" functionality to continue to retry PXE boot entries until successful. A configuration called "boot override retry" has been added. With this configured, UEFI does not rebuild the boot entries after all boot options are attempted but loops through the PXE boot options until booting is successful. Once successful, the boot override entry configuration is disabled and would need to be reenabled for future boots.
Added ability to change the CPU clock dynamically according to the temperature and other sensors of the DPU. If the power consumption reaches close to the maximum allowed, the software module decreases the CPU clock rate to ensure that the power consumption does not cross the system limit.
WarningThis feature is relevant only for OPNs MBF2H516C-CESOT, MBF2M516C-EECOT, MBF2H516C-EESOT, and MBF2H516C-CECOT.
Bug fixes
Added ability to perform warm reboot on BlueField-2 based devices
Added support for DPU BMC with OpenBMC
Added support for NVIDIA Converged Accelerator (900-21004-0030-000)