NVIDIA ConnectX-6 Dx Adapter Cards Firmware Release Notes v22.42.1000
NVIDIA ConnectX-6 Dx Adapter Cards Firmware Release Notes v22.42.1000

Bug Fixes in this Firmware Version

For a list of old Bug Fixes, please see Bug Fixes History.

Internal Ref.

Issue

3985535

Description: Fixed an issue that caused RDE PortMetrics property Transceivers.SupplyVoltage to be reflected in incorrect units of 100uV instead of V.

Keywords: RDE

Discovered in Version: 22.41.1000

Fixed in Release: 22.42.1000

3938744

Description: Prevented HCA_CAP from allowing rogue drivers to create more EQs than the number allowed in the HCA_CAP.max_num_eqs.

Keywords: HCA_CAP

Discovered in Version: 22.41.1000

Fixed in Release: 22.42.1000

3976276

Description: Fixed an issue that prevented the SFF module from accessing the EEPROM data when removing the CMIS module and inserting the SFF module instead of it.

Keywords: EEPROM, SFF, CMIS

Discovered in Version: 22.41.1000

Fixed in Release: 22.42.1000

© Copyright 2024, NVIDIA. Last updated on Aug 14, 2024.