Known Issues
VF Network Function Limitations in SRIOV Legacy Mode
Dual Port Device |
Single Port Device |
127 VF per PF (254 functions) |
127 |
VF Network Function Limitations in Switchdev Mode
Dual Port Device |
Single Port Device |
127 VF per PF (254 functions) |
127 |
VF+SF Network Function Limitations in Switchdev Mode
Dual Port Device |
Single Port Device |
|
|
Known Issues
Internal Ref. |
Issue |
RM Ticket Status |
3525865 |
Description: Unexpected system behavior might be observed if the driver is loaded while reset is in progress. |
[ConnectX FW Core - Design] BS #3525865: Won't fix [Host FW - 44.1000 GA Release (Jan25 GA)] |
Workaround: N/A |
||
Keywords: Sync 1 reset, firmware reset |
||
Discovered in Version: 20.35.3006 |
||
3261861 |
Description: Connecting an HDR device to an NDR device with Optical cables longer than 30m causes degradation in the bandwidth. |
[SoC PLATFORM] F #3251861: Closed [SOC_4.0.1 (March Rel - ES- BF3) ] |
Workaround: N/A |
||
Keywords: HDR-to-NDR, cables |
||
Discovered in Version: 20.35.1012 |
||
3209624 |
Description: To configure Adaptive Routing in RoCE through ROCE_ACCL access register or through cmdif mlxconfig, ROCE_ADAPTIVE_ROUTING_EN nvconfig parameter must be set. |
[ConnectX FW Core - Design] BS #3209624: Closed [Host FW - 35.1000 GA Release] |
Workaround: N/A |
||
Keywords: Adaptive Routing in RoCE |
||
Discovered in Version: 20.34.1002 |
||
3200779 |
Description: Changing dynamic PCIe link width is not supported. |
[ConnectX FW PCI - Design] BS #3200779: Closed (Rejected) [Host FW - 35.1000 GA Release] |
Workaround: N/A |
||
Keywords: PCIe |
||
Discovered in Version: 20.34.1002 |
||
3030570 |
Description: “crypto policy” access registry can be modified only by the INI file. |
[ConnectX FW Core - Design] BS #3030570: Closed [Host FW - 33.1000 GA Release] |
Workaround: N/A |
||
Keywords: AES_XTS |
||
Discovered in Version: 20.33.1048 |
||
2793880 |
Description: Checksum is not calculated correctly in IPoIP packet with LSO. |
[ConnectX FW Core - Design] BS #2793880: Won't fix [Host FW - 33.1000 GA Release] |
Workaround: N/A |
||
Keywords: IPoIP, LSO, checksum |
||
Discovered in Version: 20.33.1048 |
||
2864238 |
Description: VPD cannot be accessed after firmware upgrade or reset when the following sequence is performed:
|
[ConnectX FW Core - Design] BS #2864238: Won't fix [TBD] |
Workaround: Run the upgrade or reset sequence as follow:
|
||
Keywords: VDP |
||
Discovered in Version: 20.32.1010 |
||
2616755 |
Description: Forward action for IPoIB is not supported on RX RDMA Flow Table. |
[ConnectX FW Core - Design] BS #2616755: Won't fix [Host FW - Oct22 LTS-U1 35.2000 (Nov22)] |
Workaround: N/A |
||
Keywords: Steering, IPoIB |
||
Discovered in Version: 20.32.1010 |
||
2582094 |
Description: When performing a stress toggle test vs. IXIA, the IXIA side is not ready for few seconds. |
[ConnectX FW PHY - Design] BS #2582094: Closed (External) [Host FW - 32.1000 GA Release] |
Workaround: Wait for 1 sec between running the down and up commands. |
||
Keywords: Auto-negotiation. |
||
Discovered in Version: 20.31.1014 |
||
2446583 |
Description: On rare occasions, when both network devices are NVIDIA, PAM4 link will raise with several effective errors. These errors will not affect traffic once the link is up. |
[ConnectX FW - Serdes] BS #2446583: Closed [Host FW - 33.1000 GA Release] |
Workaround: Clear counters once the link is up |
||
Keywords: Effective errors |
||
Discovered in Version: 20.29.2002 |
||
SF 933911 |
Description: PXE boot will not function if the adapter card is connected to a NVIDIA Quantum™ based switch over an HDR active optical cable. |
|
Workaround: Set KEEP_LINK_UP_ON_BOOT configuration to enable via mlxconfig. For further information please contact Support. |
||
Keywords: IB, Link Speed , Link Down, SDR , optical cable |
||
Discovered in Version: 20.30.1004 |
||
2378593 |
Description: Sub 1sec firmware update (fast reset flow) is not supported when updating from previous releases to the current one. Doing so may cause network disconnection events. |
[ConnectX FW PCI - Design] BS #2378593: Closed [Host FW - 29.1000 GA Release] |
Workaround: Use full reset flow for firmware upgrade/downgrade. |
||
Keywords: Sub 1sec firmware update |
||
Discovered in Version: 20.29.1016 |
||
2213356 |
Description: The following are the Steering Dump limitations:
|
[ConnectX FW - Core] F #2213356: Closed [Host FW - 29.1000 GA Release] |
Workaround: N/A |
||
Keywords: Steering Bump |
||
Discovered in Version: 20.29.1016 |
||
2365322 |
Description: When configuring adapter card's Level Scheduling, a QoS tree leaf (QUEUE_GROUP) configured with default rate_limit and default bw_share, may not obey the QoS restrictions imposed by any of the leaf’s ancestors. |
[ConnectX FW Core - Design] BS #2365322: Closed [Host FW - 33.1000 GA Release] |
Workaround: To prevent such a case, configure at least one of the following QoS attributes of a leaf: |
||
Keywords: QoS |
||
Discovered in Version: 20.29.1016 |
||
2239632 |
Description: EDR linkup time might take up to 50sec when using HDR optical cable. |
[ConnectX FW PHY - Design] BS #2239632: Won't fix [future release] |
Workaround: N/A |
||
Keywords: Cables, EDR |
||
Discovered in Version: 20.28.1002 |
||
2145881 |
Description: FDR link is unstable when using an FDR cable in ports: #27-#34. |
[FW IB SerDes - Design] BS #2145881: Won't fix [4.4.2000/2008.2000 (MajorGA Oct20)] |
Workaround: N/A |
||
Keywords: FDR, cables |
||
Discovered in Version: 20.27.6008 |
||
2149437 |
Description: When the SLTP configuration is wrongly set, the “Bad status” explanation will not be presented (only error indication) to the user. |
[MFT] BS #2149437: Won't fix [MFT 4.18 - November 2021 release] |
Workaround: N/A |
||
Keywords: SLTP configuration |
||
Discovered in Version: 20.27.6008 |
||
2071210 |
Description: mlxconfig query for the BOOT_INTERRUPT_DIS TLV shows a wrong value in the "current value" field. |
[ConnectX FW System Mng - Design] BS #2071210: Closed (Rejected) [28.1000: GA Release] |
Workaround: Use "next boot" indication to see the right value. |
||
Keywords: mlxconfig |
||
Discovered in Version: 20.27.1016 |
||
1796936 |
Description: 200GbE Optical cables in Auto-Negotiation mode work only in 200GbE speed. |
[MKT. IB FW - unmanaged switches] FR #1796936: Committed [2020 - Rel2] |
Workaround: N/A |
||
Keywords: Cables |
||
Discovered in Version: 20.27.1016 |
||
1959529 |
Description: When HDR Active Copper cables are used between Quantum switches, or between Quantum switch and ConnectX-6 HCA, the counter indicating ‘Link Down’ may have a value other than zero, after the first time the cable is connected. As this may happened only at the first time, it is recommend to clear the counters after the cluster is brought up. |
[FW IB PHY - Design] BS #1959529: Won't fix [4.4.0900/2007.0900 (MUR3 Apr20)] |
Workaround: Toggle the Active Copper or Optics cables as the switch performs a reset. |
||
Keywords: Cables, BER |
||
Discovered in Version: 20.27.1016 |
||
1959529 |
Description: Occasionally (up to 15% of connections), the link will go down when using ACC cables P/N: MCA1J00-H003E, MCA1J00-H004E and when connecting a Quantum switch to a Quantum switch. |
[FW IB PHY - Design] BS #1959529: Won't fix [4.4.0900/2007.0900 (MUR3 Apr20)] |
Workaround: N/A |
||
Keywords: Cables |
||
Discovered in Version: 20.27.1016 |
||
1997329 |
Description: Downgrading from firmware v20.26.4012 to firmware v20.26.1040 and lower is not supported on Windows OSes using the mlxfwmanager tool. |
[ConnectX FW System Mng - Design] BS #1997329: Won't fix [26.4000: Nov -2019 MUR Release] |
Workaround: N/A |
||
Keywords: mlxfwmanager, firmware downgrade |
||
Discovered in Version: 20.26.4012 |
||
1930619 |
Description: PF_BAR2 and ATS cannot be enabled together, i.e. when PF_BAR2 is enabled, ATS cannot be enabled too. |
[ConnectX FW PCI - Design] BS #1930619: Won't fix [26.4000: Nov -2019 MUR Release] |
Workaround: N/A |
||
Keywords: ATS, SF, BAR2, Multi GVMI |
||
Discovered in Version: 20.26.1040 |
||
- |
Description: In rare cases, following a server powerup, a fatal error (device's health compromised) message might appear with ext_synd 0x8d1d. The error will be accompanied by a failure to use mlxconfig and in some cases flash burning tools. |
|
Workaround: N/A |
||
Keywords: mlxconfig, flash tool, ext_synd 0x8d1d |
||
Discovered in Version: 20.26.1040 |
||
1796936 |
Description: HDR split cables support only HDR speed. |
[MKT. IB FW - unmanaged switches] FR #1796936: Committed [2020 - Rel2] |
Workaround: N/A |
||
Keywords: Link Speed, cables, Break-Out cables |
||
Discovered in Version: 20.26.1040 |
||
1750460 / 2063991 |
Description: BER issues might occur when using ConnectX-6 adapter cards in 100GbE link speed, and connecting with and 3rd party switch systems. |
[ConnectX FW - Serdes] BS #1750460: Closed (Rejected) [27.1000: Feb -2020 GA Release] / [ConnectX FW - Serdes] BS #2063991: Won't fix [Host FW - 32.1000 GA Release] |
Workaround: N/A |
||
Keywords: BER, 100GbE, Spectrum-2 |
||
Discovered in Version: 20.26.1040 |
||
1918749 |
Description: mlxlink tool displays a wrong speed when using ETH cables on ConnectX-6 adapter cards. |
[ConnectX FW - Serdes] BS #1918749: Closed [26.4000: Nov -2019 MUR Release] |
Workaround: N/A |
||
Keywords: mlxlink |
||
Discovered in Version: 20.26.1040 |
||
1901198 |
Description: Firmware is not loaded on Multi-Host setups after reboot. |
[ConnectX FW PCI - Design] BS #1901198: Won't fix [26.1000: Sep -2019 GA Release] |
Workaround: N/A |
||
Keywords: Firmware load, Multi-Host |
||
Discovered in Version: 20.26.1040 |
||
1842278 |
Description: DC LAG can function only in case there is a single PF per port without any active VFs. |
[ConnectX FW Core - Design] BS #1842278: Won't fix [26.1000: Sep -2019 GA Release] |
Workaround: N/A |
||
Keywords: DC LAG |
||
Discovered in Version: 20.26.1040 |
||
1796628 |
Description: Due to performance considerations, unicast loopback traffic will go through the NIC SX tables, and multicast loopback traffic will skip the NIC SX tables. |
[ConnectX FW Core - Design] BS #1796628: Won't fix [26.1000: Sep -2019 GA Release] |
Workaround: N/A |
||
Keywords: Performance, unicast loopback traffic, multicast loopback traffic |
||
Discovered in Version: 20.26.1040 |
||
1797493 |
Description: Firmware asserts may occur when setting the PF_BAR2_SIZE value higher than the maximum supported size. |
[MKT.BlueField-SW] FR #1797493: Committed [2020 - Rel3] |
Workaround: Configure within limits (NIC PF_BAR_SIZE <= 4). |
||
Keywords: Multi-GVMI, Sub-Function, SFs, BAR2 |
||
Discovered in Version: 20.26.1040 |
||
- |
Description: Coherent Accelerator Processor Interface (CAPI) in ConnectX-6 firmware v20.25.7020 and above has low test coverage, however, it has no known issues. |
|
Workaround: N/A |
||
Keywords: CAPI |
||
Discovered in Version: 20.25.7020 |
||
- |
Description: HDR optical cables and Split cables support only HDR speed. |
|
Workaround: N/A |
||
Keywords: Link Speed, cables, Break-Out cables |
||
Discovered in Version: 20.25.6000 |
||
1755286 |
Description: Port speed may change to SDR spontaneously, without a clear reason. |
[UEFI Driver] BS #1755286: Closed [14.22.50] |
Workaround: Keep the "keep_ib_link_up" bit at 0 in NVconfig to make sure the port is raised with the correct speed. |
||
Keywords: SDR, port speed |
||
Discovered in Version: 20.25.2006 |
||
1774135 |
Description: PXE boot is not functional when connecting a splitter cable to the host. |
[OpenSM] BS #1774135: Closed (Rejected) |
Workaround: Update the SM as follow:
Default=0x7fff,ipoib,rate=5:ALL=full; Note: "rate" must be set to "5" regardless to the other flags values.
Run the following CLI commands:
Use REST API to change default partition rate: PUT https://<some IP>/ufmRest/resources/networks/management
As a result, /opt/ufm/files/conf/opensm/partitions.conf will include the following line: management=0x7fff,ipoib, sl=0,rate=5, defmember=full : ALL, ALL_SWITCHES=full,SELF=full; |
||
Keywords: PXE boot, splitter cable |
||
Discovered in Version: 20.25.2006 |
||
1768814/1772474 |
Description: Due to hardware limitation, REG_C cannot be passed over loopback when the FDB action is forwarded to multiple destinations. |
[ConnectX FW Core - Design] BS #1768814: Won't fix [Host FW - 25.6000: June-2019 MUR] / [ConnectX FW Core - Design] BS #1772474: Closed (Rejected) [Host FW - 25.6000: June-2019 MUR] |
Workaround: N/A |
||
Keywords: Connection-Tracking |
||
Discovered in Version: 20.25.2006 |
||
1770736 |
Description: When a PF or ECPF with many VFs (SR-IOV), and/or SFs (Multi-GVMI) triggers an FLR, PCIe completion timeout might occur. |
[ConnectX FW Core - Design] BS #1770736: Won't fix [future release] |
Workaround: Increase the PCIe completion timeout. |
||
Keywords: Multi-GVMI, SR-IOV, Sub-Function, Virtual Function, PF FLR |
||
Discovered in Version: 20.25.2006 |
||
1716334 |
Description: When mlxconfig.PF_BAR2_EN is enabled, configuring more than 255 PCI functions will raise an assert. |
[ConnectX FW Core - Design] BS #1716334: Won't fix [Host FW - 25.1000: 15-Apr-2019 GA Release] |
Workaround: When working with BAR2, configure SR-IOV to align to the 255 PCI functions limitation. mlxconfig.NUM_OF_VFS controls the number of configured SR-IOV VFs. e.g.:
|
||
Keywords: Multi-GVMI, PF_BAR2_EN, Sub-Functions, SR-IOV, VFs |
||
Discovered in Version: 20.25.1500 [Beta] |
||
1699214 |
Description: NODNIC VF is partially tested. It is fully tested only in ConnectX-5 adapter cards. |
[ConnectX FW Core - Design] BS #1699214: Closed (Rejected) [future release] |
Workaround: N/A |
||
Keywords: NODNIC VF |
||
Discovered in Version: 20.25.1500 [Beta] |
||
1699214 |
Description: NODNIC VF is partially tested. It is fully tested only in ConnectX-5 adapter cards. |
[ConnectX FW Core - Design] BS #1699214: Closed (Rejected) [future release] |
Workaround: N/A |
||
Keywords: NODNIC VF |
||
Discovered in Version: 20.25.1500 [Beta] |
||
- |
Description: The supported length of HDR copper cables is currently up to 2M. |
|
Workaround: N/A |
||
Keywords: HDR cables |
||
Discovered in Version: 20.25.1500 [Beta] |
||
- |
Description: In Ethernet mode, at 10/40GbE speeds, only NO-FEC in Force mode is supported. Other user configurations are overridden. |
|
Workaround: N/A |
||
Keywords: Ethernet, 10GbE, 40GbE, RS-FEC |
||
Discovered in Version: 20.25.1500 [Beta] |
||
1574876 |
Description: DC RoCE LAG is functional only if the router posts VRRP address as the source MAC. |
[ConnectX FW Core - Design] BS #1574876: Won't fix [future release] |
Workaround: N/A |
||
Keywords: DC RoCE LAG |
||
Discovered in Version: 20.25.1500 [Beta] |
||
1498399 |
Description: If the XRC switches between SRQ/RMPs while there is an outstanding ODP on the responder XRC QP, a CQE with an error might be generated (that is not a PFAULT abort). |
[ConnectX FW Core - Design] F #1498399: Closed (Rejected) [Host FW - 25.1000: 15-Apr-2019 GA Release] |
Workaround: N/A |
||
Keywords: XRC SRQ/RMP ODP |
||
Discovered in Version: 20.25.1500 [Beta] |
||
- |
Description: In some cases, the power consumption might be 10% higher than what is stated in the adapter cards User Manual. |
|
Workaround: Power consumption will be aligned with the User Manual statement in the next release |
||
Keywords: Power consumption |
||
Discovered in Version: 20.25.1500 [Beta] |
||
1546492 |
Description: Executing the update_lid command while the IB port sniffer utility is active can stop the utility. |
[ConnectX FW Core - Design] BS #1546492: Won't fix [future release] |
Workaround: N/A |
||
Keywords: IB Sniffer |
||
Discovered in Version: 20.25.1500 [Beta] |
||
1537898 |
Description: Initializing a function while the IB port sniffer utility is active can stop the utility. |
[ConnectX FW Core - Design] BS #1537898: Won't fix [future release] |
Workaround: N/A |
||
Keywords: IB Sniffer |
||
Discovered in Version: 20.25.1500 [Beta] |
||
1414290 |
Description: When getting an inline scatter CQE on IB striding RQ, the stride index in the CQE will be zero. |
[ConnectX FW Core - Design] BS #1414290: Won't fix [26.1000: Sep -2019 GA Release] |
Workaround: N/A |
||
Keywords: Scatter CQE |
||
Discovered in Version: 20.25.1500 [Beta] |
||
1332714/1345824 |
Description: The maximum “read” size of MTRC_STDB is limited to 272 Bytes. |
[ConnectX FW Core - Design] BS #1332714: Closed (Rejected) [Host FW - 23.1000: 15-June-2018 GA Release] / [ConnectX FW Core - Design] BS #1345824: Won't fix [27.1000: Feb -2020 GA Release] |
Workaround: Set the MTRC_STDB.read_size to the maximum value of 0x110=272 Bytes |
||
Keywords: Access register, MTRC_STDB, tracer to dmesg, fwtrace to dmesg |
||
Discovered in Version: 20.25.1500 [Beta] |
||
1408994 |
Description: FTE with both forward (FWD) and encapsulation (ENCAP) actions is not supported in the SX NIC Flow Table. |
[ConnectX FW Core - Design] BS #1408994: Closed (Rejected) [Host FW - 23.1000: 15-June-2018 GA Release] |
Workaround: N/A |
||
Keywords: SX NIC Flow Table |
||
Discovered in Version: 20.25.1500 [Beta] |
||
1027553 |
Description: While using e-switch vport sVLAN stripping, the RX steering values on the sVLAN might not be accurate. |
[ConnectX FW Core - Design] BS #1027553: Won't fix [Host FW - 24.1000: 15-Nov-2018 GA Release] |
Workaround: N/A |
||
Keywords: e-sw vport sVLAN stripping, RX steering |
||
Discovered in Version: 20.25.1500 [Beta] |
||
1799917 |
Description: Untagged CVLAN packets in the Steering Flow Tables do not match the SVLAN tagged packets. |
[ConnectX FW Core - Design] BS #1799917: Won't fix [26.1000: Sep -2019 GA Release] |
Workaround: N/A |
||
Keywords: Steering Flow Tables, CVLAN/SVLAN packets |
||
Discovered in Version: .20.25.1500 [Beta] |
||
1277762 |
Description: An Ethernet multicast loopback packet is not counted (even if it is not a local loopback packet) when running the nic_receive_steering_discard command. |
[ConnectX FW Core - Design] BS #1277762: Won't fix [Host FW - 22.1000: 15-Feb-2018 GA Release] |
Workaround: N/A |
||
Keywords: Ethernet multicast loopback packet |
||
Discovered in Version: 20.25.1500 [Beta] |
||
1306342 |
Description: Signature-accessing WQEs sent locally to the NVMeF target QPs that encounter signature errors, will not send a SIGERR CQE. |
[ConnectX FW Core - Design] BS #1306342: Won't fix [26.1000: Sep -2019 GA Release] |
Workaround: N/A |
||
Keywords: Signature-accessing WQEs, NVMeF target |
||
Discovered in Version: 20.25.1500 [Beta] |
||
1168594 |
Description: RoCE Dual Port Mode (a.k.a Multi-Port vHCA: MPV) is not supported in Multi-Host setups. |
[ConnectX FW Core - Design] BS #1168594: Won't fix [Host FW - 22.1000: 15-Feb-2018 GA Release] |
Workaround: N/A |
||
Keywords: Multi-Port vHCA, Multi-Host |
||
Discovered in Version: 20.25.1500 [Beta] |
||
1072337 |
Description: If a packet is modified in e-sw flow steering, the SX sniffer Flow Table (of the VF) will see the sniffed packet after the modification. |
[ConnectX FW Core - Design] BS #1072337: Won't fix [Host FW - 23.1000: 15-June-2018 GA Release] |
Workaround: N/A |
||
Keywords: SX sniffer Flow Table |
||
Discovered in Version: 20.25.1500 [Beta] |
||
1171013 |
Description: Signature Handover Operations is not supported when FPP (Function-Per-Port) mode is disabled. |
[ConnectX FW Core - Design] BS #1171013: Won't fix [Host FW - 22.1000: 15-Feb-2018 GA Release] |
Workaround: N/A |
||
Keywords: Signature Handover Operations, FPP |
||
Discovered in Version: 20.25.1500 [Beta] |
||
1059975 |
Description: NVMeF limitation:
|
[ConnectX FW - Core] D #1059975: Closed [Host FW - 20.1000: 30-June-2017 GA Release ] |
Workaround: N/A |
||
Keywords: NVMeF |
||
Discovered in Version: 20.25.1500 [Beta] |