NVIDIA ConnectX-6 Lx Adapter Cards Firmware Release Notes v26.47.1026

Bug Fixes in this Firmware Version

Internal Ref.

Issue

4501554

Description: Fixed an assertion failure that could occur with the E-Switch uplink in specific configurations where the e-switch was disabled and Path Migration was active or GVMIs were using SRQ loopback in SQs. The issue occurred because the firmware attempted to perform cleanup operations when the uplink configuration lacked sufficient capacity.

Now, when the E-Switch is disabled and no actions are available in the uplink STE, the firmware connects to the uplink STE instead of copying it.

Keywords: Path migration, steering

Detected in version: 26.46.1006

Fixed in Release: 26.47.1026

4529293

Description: Fixed an issue where, during failover or restart, the SM sending a PortInfo MAD to the HCA firmware triggered reinitialization of port buffers, momentarily halting ingress traffic and causing packet drops.

The firmware now avoids reconfiguring port buffers when the new configuration matches the current one.

Keywords: OpenSM

Discovered in Version: 26.46.1006

Fixed in Release: 26.47.1026

For a list of old Bug Fixes, please see Bug Fixes History.